Flowline DX10 Specifications

EchoPod DX10 Ultrasonic Level Sensor (Voltage or Frequency)
®
Application
The general purpose ultrasonic level transmitter
provides continuous level measurement up to 49.2”
(1.25m) with a selectable 0-5 VDC, 0-10 VDC or 976­2000 Hz frequency signal output, and is congured via our free WebCal software. Select the voltage output for interface with analog input cards. Select the frequency output for interface with discrete input cards. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for small day tank, skid, IBC, sump
and process tank level applications.
®
Features
Continuous non-contact level measurement up to
49.2” (1.25m)
Selectable voltage or frequency (discrete) signal
outputs
Conguration is fast and easy via WebCal software
and USB adapter
Narrow 2” beam width and short 2” dead band
optimized for small tanks
corrosive liquids
Automatic temperature compensation for accurate
measurement
Success
The disinfection of fresh
produce and associated processing equipment is
essential to public health. Fruits and vegetables such as strawberries, head lettuce, tomatoes, oranges and artichokes are susceptible
to bacterial and viral
contamination. Each year,
approximately 40K Americans succumb to Hepatitis A food poisoning. Adults who become ill miss an average of 27 work days. Eleven percent of them are hospitalized and 100 people die each year from acute liver failure. Good Manufacturing Practices and new FDA recommendations call for the disinfection of all fresh produce and processing equipment. To accomplish this,
produce suppliers are deploying automated systems
that generate, inventory and inject chlorine dioxide into their processes. These are typically small systems that use 55-gal-drum or mini-bulk tanks for chemical make up and storage. From inventory to data-logging, level is critical in these highly corrosive applications. EchoPod is the reliable, level measurement, switch and control solution for chlorine disinfection systems.
Compatible Products
DataLoop
Level Indicator
LI25
© 2016 Flowline Inc. • 10500 Humbolt Street Los Alamitos, CA 90720 • 562.598.3015 • www.owline.com • DS300200 REV C
DataView
Level Controller
Commander
Multi-Tank Level Controller
LI55 LI90
DataPoint
Level Controller
LC52
EchoPod DX10 Ultrasonic Level Sensor (Voltage or Frequency)
EchoPod
Ordering Notes
1) Install the level sensor using Flowline installation fittings or equivalents.
2) The level sensor is configured via our WebCal software and one LI99-1001 Fob USB adapter. The level sensor is offered with and without a Fob. Fobs are universal and can be used to configure
®
®
Specications
Range: 49.2” (1.25m)
Accuracy: 0.125” (3mm)
Resolution: 0.019” (0.5mm)
Dead band: 2” (5cm)
Beam width: 2” (5cm)
Conguration: WebCal® PC
Windows® USB 2.0
Memory: Non-volatile
Supply voltage: 12-24 VDC
Consumption: 0.5W
Signal output: 0-5 V, 0-10 V, 976-2000 Hz
Frequency: Sink current, 15 mA nominal
Signal invert: 5-0 V, 10-0 V, 2000-976 Hz
Signal fail-safe: Full, empty or hold last
Process temp.: F: 20° to 140°
C: -7° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -31° to 140°
C: -35° to 60°
Pressure: MWP = 30 PSI (2 bar)
Enclosure rating: Type 6P, encapsulated,
corrosion resistant &
submersible
Encl. material: Polycarbonate
Strain relief mat: Santoprene
Trans. material: PVDF
Cable jacket mat: Polyurethane
Cable type: 6-conductor, shielded
Cable length: 48” (1.2m)
Process mount: 1” NPT (1” G)
Mount gasket: Viton®
Classication: General purpose
Compliance: CE, RoHS
Approvals: cFMus
Dimensions
Conguration
LI99-1001
The level sensor is congurable via our free WebCal PC software and Fob USB adapter. The sensors are offered with and without Fobs. Fobs
are universal and can be used to
congure any WebCal compatible
product.
Download your free copy of WebCal in English or Chinese at www.owline.com/webcal.php.
Fittings
For optimum performance, install the level sensor using the below recommended or direct equivalent ttings.
P/N Description
LM52-1400 2” NPT x 1” NPT (Sch. 40)
LM52-1800 2” NPT x 1” NPT (Sch. 80)
LM52-1410 2” Socket x 1” NPT (Sch. 40)
LM52-1810 2” Socket x 1” NPT (Sch. 80)
LM52-1850 1” NPT Flange - 150# (Sch. 80)
LM50-1001-1 1” NPT Bracket, Polypropylene
Ordering
DX10-
Process mount (1) 0 NPT (US) 1 G (Metric)
Fob USB adapter (2) 0 Without Fob 1 With Fob
© 2016 Flowline Inc. • 10500 Humbolt Street Los Alamitos, CA 90720 • 562.598.3015 • www.owline.com • DS300200 REV C
Notes
1) Install the level sensor using Flowline installation ttings or equivalents.
2) The level sensor is congured via our WebCal software and one LI99-1001 Fob USB adapter. The level sensor is offered with and without
a Fob. Fobs are universal and can be
used to congure any WebCal compatible product. WebCal is a free download from our website at www.owline.com/webcal.php.