Safety 2
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. This is the safety alert symbol. When you
see this symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for personal injury!
indicates a hazard which, if not avoided, will result in
death or serious injury.
indicates a hazard which, if not avoided, could result in
death or serious injury.
indicates a hazard which, if not avoided, could result in
minor or moderate injury.
NOTICE addresses practices not related to personalinjury.
Carefully read and follow all safety instructions in this manual and on
pump. Keep safety labels in good condition. Replace missing or dam-
aged safety labels.
California Proposition 65 Warning
This product and related accessories contain chemicals
known to the State of California to cause cancer, birth defects or other
reproductive harm.
Carefully read and follow all safety instructions in this manual and on
pump. Keep safety labels in good condition.
Replace missing or damaged safety labels.
1.
Read this manual carefully. Failure to follow these instructions could
cause serious bodily injury and/or property damage.
2. Check your local codes before installing. You must comply with
their rules.
3.
Connect the pump to a separate circuit with no other appliances on
the circuit. Consult a licensed electrician for all wiring.
NOTICE: This pump does not require a connection to a main stack vent,
per the National Standard Plumbing Code (NSPC) 2003 Section 11.7.9.
Hazardous voltage. Can shock, burn or cause
death. Unplug pump before working on it.
INSTALLATION (SEE FIGURES 1 AND 2)
Electric Shock Hazard. Plug pump into a properly
grounded, GFCI protected outlet. Do NOT plug in the pump until after
it is completely installed. Do not remove or modify the grounding pins
on the plugs.
Sink Bottom with Drain Port;
Sink Bottom with Drain Port;
Tail Piece integral with Sink
Tail Piece integral with Sink
A
A
1
1
9
2
2
3
3
1-1/2” Pump
1-1/2” Pump
Inlet Port
Inlet Port
1-1/4” Pump
1-1/4” Pump
Discharge
Discharge
For easier maintenance,
For easier maintenance,
use 2 short sections of
use 2 short sections of
pipe connected by a
pipe connected by a
1-1/2” Solvent Union.
1-1/2” Solvent Union.
4
4
5
5
6
6
7
7
9
B
B
C
C
6
6
7
7
8
8
DESCRIPTION
This pump is designed to be used with a sink where a gravity drain line
is not available. Attach the pump to the drain tail piece; the pump will
start when water begins to drain. Uses include basement laundry sinks,
wet bars and utility sinks.
SPECIFICATIONS
Power supply required .......................................................... 115V, 60 HZ.
Liquid Temp. Range ............................................ 32° – 120°F (0° – 50°C)
5 1-1/4” NPT Galvanized Union 1
6 1-1/4” NPT x 1-1/4” Male Adapter 2
6 1-1/4” NPT x 1-1/4” Male Adapter 2
7 1-1/4” Schedule 40 PVC Pipe, to fit 4
7 1-1/4” Schedule 40 PVC Pipe, to fit 4
8 1-1/4” Socket to Socket 90° Elbow 1
8 1-1/4” Socket to Socket 90° Elbow 1
9 1-1/4” Schedule 40 PVC Pipe to Drain As Needed
9 1-1/4” Schedule 40 PVC Pipe to Drain As Needed
PVC Pipe Cement As Needed
PVC Pipe Cement As Needed
PTFE pipe thread sealant tape As Needed
PTFE pipe thread sealant tape As Needed
1-1/2” Plastic Solvent Union
1-1/2” Plastic Solvent Union
(For Drop Pipe – Optional)
(For Drop Pipe – Optional)
NOTE: Be careful to avoid cross-threading;
NOTE: Be careful to avoid cross-threading;
Use only a plastic-compatible pipe-threading
Use only a plastic-compatible pipe-threading
compound or PTFE pipe thread sealant tape
compound or PTFE pipe thread sealant tape
when connecting threaded fittings to plastic adapters.
when connecting threaded fittings to plastic adapters.
Figure 1: Typical method of mounting the pump.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Installation 3
PUMP INSTALLATION
Mount the pump
NOTICE: DO NOT use plumber’s pipe threading compound (“pipe
dope”) on plastic pipe; it can damage the plastic, causing leaks and
piping failure and voiding the warranty.
1. Place the sink in its final location.
2. Remove any existing drain fittings back to the tail piece (Figure 1).
Make sure the existing tail piece does not leak.
NOTICE: If the sink-drain tail piece is not 1-1/2” NPT, you will have
to adapt it (bushings, reducers, etc.). In this case, wrap all joints
with PTFE pipe thread sealant tape before making connections.
3. Glue the 1-1/2” PVC pipe into the female adapter (purchase
separately).
cement manufacturer’s instructions when using PVC cement. Do not
use near fire or open flame.
4. Wrap the threads of the tail piece with 1 to 1-1/2 turns of PTFE pipe
thread sealant tape. Thread the 1-1/2” NPT female adapter onto the
sink-drain tail piece. Thread it hand tight plus 1/2 turn with a pipe
wrench or slip joint pliers. DO NOT overtighten.
5. Wrap the threads of the 1-1/2” male adapter with 1 to 1-1/2 turns
of PTFE pipe thread sealant tape and install it in the pump inlet.
Tighten it hand tight plus 1/2 turn with a pipe wrench or slip joint
pliers. DO NOT overtighten!
6. Measure the 1-1/2” PVC pipe against the drain and the pump and
trim the pipe to fit.
Fire and explosion hazard. Be sure to follow the
Discharge Pipe**
Laundry
Sink
Check Valve*
Shut-Off/FlowBalancing Valve*
1-1/4” Male Adapter**
1-1/4” Union**
1-1/4” PVC
1-1/2” Female
Adapter**
1-1/2” PVC**
1-1/2” Male
Adapter**
Screen*
†
7. Do a trial assembly (dry - no glue) of the pump onto the drain pipe.
Swing the pump until it accurately faces the discharge piping, and
then mark the pump and the inlet pipe/adapter assembly so that
you can accurately install the pump in Step 8. Arrange a temporary
support under the pump to relieve the strain on the sink drain
piping while the glue is setting. Leave it in place while you measure
and cut the discharge piping (Step 12).
8. Slide the pump up into position and glue the pipe into the male
adapter (on the pump).
• No glue on the pump or in the motor;
• Make sure the pump is facing the right direction (match the
marks from Step 7);
• Put the support in place under the motor.
9. Wrap the 1-1/4” galvanized nipple with 1-1/2 to 2turns of PTFE
pipe thread sealant tape on each end and thread it into the pump
discharge port.
NOTICE: Tighten this only enough to prevent leaking. Overtightening can crack the plastic.
10. Hold the nipple with a pipe wrench and thread one half of the
1-1/4” union onto it, hand tight plus 1-1/2 turns with a pipe wrench
or slip-joint pliers.
11. At this time, wrap the threads on both the 1-1/4” male adapters
with 1-1/2 to 2 turns of PTFE pipe thread sealant tape. Thread
one of the adapters into the other half of the 1-1/4” union, hand
tight plus 1/2 turn with a wrench or a pair of slip-joint pliers.
DO NOT overtighten!
12. Install the discharge piping as shown in Figures 1 and 2. The
order is:
1-1/4” PVC Pipe cut to fit,
90° Soc. to Soc. elbow,
1-/14” PVC Pipe cut to fit,
Male adapter,
Flow Control/Ball Valve,
Check Valve,
(NOTICE: Install the check valve in the vertical discharge pipe with
the threads down. Be sure the flow arrow points AWAY from the
pump. That is, when the check valve is correctly installed, the arrow
showing direction of flow should point UP.)
1-1/4” Outlet Pipe.
13. Connect the discharge piping to the building drain.
Plug in the Pump
AFTER the pump is completely installed, plug the switch into a GFCIprotected, properly grounded outlet. Plug the pump into the back of the
switch’s plug.
Pump*
1-1/4” Nipple**
* Required and included
** Purchase separately
†
For easier removal for servicing or cleaning,
install a 1-1/2” solvent union in the drop pipe.
Figure 2: Pump Installed.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
1-1/4” Socket to
Socket 90° Elbow**
5799 0308
Installation / Maintenance 4
Adjusting The Flow
The drain pump can pump up to 27 gallons per minute (GPM). Normal
sink drains allow only 5 to 6 GPM to flow. Adjust the discharge shut-off/
flow balancing valve as follows so that the pump does not cycle on and
off when the faucets are on full.
1. Run water into the sink. The pump will start when it detects water.
2. Check for leaks. If leaks are found, unplug the pump power cord
and fix the leaks before proceeding.
3. Put a stopper in the drain and allow the sink to fill up a few inches.
4. Open the discharge shut-off valve, open the faucets, and remove
the stopper to drain the sink.
5. The pump will start. Adjust the discharge shut-off/flow balancing
valve until the pump runs continuously while the faucets are
running and the sink is draining. If the water level rises with the
pump on, slightly open the discharge valve to balance the flow. If it
drops, slightly close the discharge valve.
Washing Machine Use
Washing machines usually discharge more water than the faucets do,
and it is normal for the water level to rise in the sink while the pump
is discharging. Do not adjust the discharge valve to match the flow
w hen the washing machine discharges into it, unless the sink is ONLY
used for washing machine discharge.
NOTICE: Washing machine discharge water contains fiber and
lint. Unfiltered washing machine discharge could plug the pump and
require pump disassembly for cleaning. To avoid this, install a lint trap
or bag type filter in the washing machine discharge line and clean it
out regularly.
MAINTENANCE
This pump requires very little maintenance and should provide a long
service life. Problems are rare; when the pump flow drops off, the most
likely cause is something solid going down the drain and jamming the
impeller.
To clear a jammed impeller:
1. Unplug the Pump.
2. Close the discharge shutoff valve.
3. Bail out the sink as much as possible.
4. Disconnect the union, unscrew the pump from the sink tail piece,
lower the pump to the floor, and slide it out from under the sink (see
Figure 3).
5. Remove the six housing screws (see Figure 4).
6. Clean out the pump. Make sure that the pump discharge is clear. If
necessary, replace the impeller.
7. Install the new gasket (included with impeller). Reassemble the
pump.
8. Raise the pump back into position, thread it back onto the sink tail
piece, and reconnect the union.
9. Plug in the pump. Run water in the sink until the pump has run
at least one complete cycle to make sure the pump is operating
correctly and there are no leaks.
Discharge Pipe
Discharge Pipe
Laundry
Laundry
Sink
Sink
Check Valve
Screen
Screen
†
1-1/2” PVC
1-1/2” PVC
Pump
Pump
†
†
For easier removal for servicing or cleaning,
For easier removal for servicing or cleaning,
install a 1-1/2” solvent union in the drop pipe.
install a 1-1/2” solvent union in the drop pipe.
†
Check Valve
Shut-Off/Flow-
Shut-Off/FlowBalancing Valve
Balancing Valve
1-1/4” Union Half
1-1/4” Union Half
1-1/4” Union
1-1/4” Union
Half
Half
Figure 3: Pump Removal.
5800 0308
5800 0308
5801 0308
Figure 4: Remove six housing screws to clean out pump.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Troubleshooting 5
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Pump does not run when water Pump unplugged. Plug in pump.
flows in from sink
Pump impeller jammed. Unplug pump; follow procedure under “Maintenance”
to clear pump.
Sink stopper in drain. Remove stopper.
Pump runs, but does not empty Drain clogged. Clear drain screen.
sink
Clogged discharge line. Unplug pump, open and clear discharge line.
Shut-off valve closed. Open shut-off valve slightly.
System discharge line too Unplug pump and reduce height or length of discharge line
high or too long. (11’ Max. Height).
Check valve installed Make sure flow arrow on check valve points away
backwards from pump.
Pump cycles on and off when Check valve not installed. Unplug pump and install check valve (see Figures 2
no water is in the sink and 3, Pages 3 and 4).
Check valve jammed. Unplug pump; open discharge line and clean check valve.
Pump cycles on and off when the Shut-off valve not adjusted. See “Adjusting the Flow”, Page 3.
sink is at maximum water
flow or is full
No power to outlet. Check fuse / breaker.
Shut-off valve not installed. Unplug pump and install shut-off valve (see Figures 2
and 3, Pages 3 and 4).
1
3
2
5802 0308
REPAIR KIT, Part No. PS20-137REP
Key No.Part DescriptionQty.
1Diaphragm Switch1
2Impeller1
3Gasket1
FITTINGS KIT, Part No. PS198-291
1-1/4” NPT x 1-1/4” Slip Check Valve1
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Sink Drain Screen1
1-1/4” Ball Valve1