OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of this product.
We recommend, for additional protection, the pump to be supplied from socket outlet protected by a residual current device – RCD (also known as an Earth Leakage Circuit Breaker – ELCB) with a maximum rated residual current of 30mA.
AUTOJET &
MULTIMAX
®
For the installation, operation and service of
STAINLESS STEEL JET PUMPS
• Autojet60 • Autojet80 • Multimax120
2
L100235 - Autojet & Multimax Owner’s manual | Copyright© Pentair Australia Pty Ltd 2017
Table of Contents Page
Model Data 3
Application 4
Installation 5
Operation 10
Service and Maintenance 11
Trouble Shooting 12
Warranty 13
3
L100235 - Autojet & Multimax Owner’s manual | Copyright© Pentair Australia Pty Ltd 2017
Model Data
Model
Motor
(W)
AJP60 600
AJP80 1100
MMP1200 1100
Technical Information
Inlet (Suction): 1” BSPF
Outlet (Discharge): 1” BSPF
Water Temperature Range: 1º - 40ºC
IP Rating: IPX4/F
Electrical Supply: 230V, 50Hz
single phase
Maximum Ambient temperature: 40 ºC
4
L100235 - Autojet & Multimax Owner’s manual | Copyright© Pentair Australia Pty Ltd 2017
Application
Flotec AJ & MM Series pumps are suitable for pumping clean water in a domestic water system, small irrigation applications, and as pressure booster pumps. The strength of the stainless steel pump casing coupled with the impervious nature of the technopolymer impeller and diffuser make it ideally suited for most potable water pumping applications.
5
L100235 - Autojet & Multimax Owner’s manual | Copyright© Pentair Australia Pty Ltd 2017
Installation
We strongly recommend this product be installed by a suitably qualified person.
The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class 1, IPX4 rated products.
These instructions are a guide only. Users not familiar with pumping equipment should seek advice from people experienced in pump equipment and installation.
Freezing conditions will damage the unit, because when water freezes it expands. Ensure that the pump is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions.
AJ & MM pumps are electrically connected. Ensure that they are switched off and unplugged from socket outlet during installation and any subsequent service work.
The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive environment or near combustible matter.
Incorrectly installed or tested equipment may fail, causing severe injury or property damage.
Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. Automatic thermal overload cut-out protects the motor for heat damage during operation and it will restart without notice when the motor cools down.
The pump is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the pump.
Read the following instructions in this owner’s manual when installing and operating equipment.