2001H Series Peristaltic Pump O&M Manual
Pg. 2
Installation and Operation Manual
2001H Series
Peristaltic Chemical Feed Pump
May 2017
Flomotion Systems, Inc.
Buffalo, NY 14228-2103
info@flomotionsystems.com
Toll Free: (800) 909-3569
Tel: (716) 691-3941
Fax: (716) 691-1253
Flomotion Systems, Inc. 2001H Series
Page 3
2001H Series Peristaltic Pump O&M Manual
Pg. 3
TABLE OF CONTENTS
Table of Contents
1.0 - SYSTEM OVERVIEW.....................................................................................................................................................................4
1.1 SAFETY...............................................................................................................................................................................................4
1.2 WARRANTY.........................................................................................................................................................................................4
1.3 RECEIVING..........................................................................................................................................................................................5
1.4 CUSTOMER MODIFICATION...................................................................................................................................................................5
1.5 INFORMATION FOR RETURNING PUMPS ................................................................................................................................................5
2.0 – 2001H SERIES PUMP AND PUMPHEAD....................................................................................................................................6
2.1 TUBING, SPINDLE AND COVER INSTALLATION.......................................................................................................................................7
2.2 MOUNTING PUMP ON GEARBOX, INSTALLATION OF COLLET.................................................................................................................8
2.3 PUMP MOUNTING AND COLLET INSTALLATION PROCEDURE..................................................................................................................9
2.4 TUBE AND ROLLER INSTALLATION.....................................................................................................................................................10
2.5 TUBING & CONNECTIONS...................................................................................................................................................................16
Tubing and Accessory Part Numbers...............................................................................................................................................17
3.0 – 2001H MOTOR & GEARBOX.....................................................................................................................................................18
3.1 MOTOR SPECIFICATIONS....................................................................................................................................................................18
3.3 GEARHEAD SPECIFICATIONS...............................................................................................................................................................18
4.0 – K4 SERIES PUMP CONTROLLER............................................................................................................................................19
4.1 OPERATION AND WIRING...................................................................................................................................................................19
4.2 PROGRAMMING .................................................................................................................................................................................19
4.3 INTERFACING TO THE 2001H K4 SERIES PUMP CONTROLLER..........................................................................................................20
5.0 - 2001 SERIES TUBING RUPTURE DETECTOR.......................................................................................................................21
RUPTURE DETECTOR SYSTEM OVERVIEW.................................................................................................................................................21
5.1 ALARM CAUSES.................................................................................................................................................................................21
5.2 WHAT TO DO IN AN ALARM CONDITION...............................................................................................................................................21
5.3 RESETTING THE ALARM......................................................................................................................................................................21
5.4 RESUMING SERVICE...........................................................................................................................................................................21
Flomotion Systems, Inc. 2001H Series
Page 4
2001H Series Peristaltic Pump O&M Manual
Pg. 4

1.0 - System Overview

The 2001H Series Chemical Feed Pump consists of a controller, motor, gearbox and peristaltic pump.
Model 2001H
with wall mount controller.

1.1 Safety

In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have read and understood this manual, and considered any hazard involved. Any person who is involved in the installation or maintenance of this equipment should be fully competent to carry out the work.
with pump-mounted controller
Model 2001H
Maintenance and repair should be performed by qualified personnel only. Make sure that no voltage is applied while work is being carried out on the pump or motor. The motor must be secured against accidental start up.

1.2 Warranty

Flomotion Systems, Inc. warrants the 2001 Series pumps to be free of defects in material and workmanship for a period of eighteen months from the date of sale to the user, or two years from the date of shipment, which ever occurs first. An MC Series control, or any component contained therein, which under normal use becomes defective within the stated warranty time period, shall be returned to Flomotion Systems, Inc., freight prepaid, for examination (contact Flomotion Systems, Inc. for authorization prior to returning any product). Flomotion Systems, Inc. reserves the right to make the final determination as to the validity of a warranty claim, and sole obligation is to repair or replace only components, which have been rendered defective due to faulty material or workmanship. No warranty claim will be accepted for components which have been damaged due to mishandling, improper installation, unauthorized repair and/or alteration of the product, operation in excess of design specifications or other misuse, or improper maintenance. Flomotion Systems, Inc. makes no warranty that its products are compatible with any other equipment, or to any specific application, to which they may be applied and shall not be held liable for any other consequential damage or injury arising from the use of its products. This warranty is in lieu of all other warranties, expressed or implied. No other person, firm or corporation is authorized to assume, for Flomotion Systems, Inc., any other liability in connection with the demonstration or sale of its products.
Flomotion Systems, Inc. 2001H Series
Page 5
2001H Series Peristaltic Pump O&M Manual
Pg. 5

1.3 Receiving

Inspect all cartons for damage, which may have occurred during shipping. Carefully unpack equipment and inspect thoroughly for damage or shortage. Report any damage to carrier and/or shortages to supplier. All major components and connections should be examined for damage and tightness, with special attention given to PC boards, plugs, knobs and switches.

1.4 Customer Modification

Flomotion Systems, Inc., its sales representatives and distributors, welcome the opportunity to assist our customers in applying our products. Many customizing options are available to aid in this function. Flomotion Systems, Inc. cannot assume responsibility for any modifications not authorized by its engineering department.

1.5 Information for Returning Pumps

Equipment that has been contaminated with, or exposed to, body fluids, toxic chemicals or any other substance hazardous to health must be decontaminated before it is returned to Flomotion Systems or its distributor.
A certificate included at the rear of these operating instructions, or signed statement, must be attached to the outside of the shipping container.
This certificate is required even if the pump is unused. If the pump has been used, the fluids that have been in contact with the pump and the cleaning procedure must be specified along with a statement that the equipment has been decontaminated.
Flomotion Systems, Inc. 2001H Series
Page 6
2001H Series Peristaltic Pump O&M Manual
Pg. 6

2.0 – 2001H Series Pump and Pumphead

The 2001H Series pumphead has two spring-loaded working rollers, which automatically compensate for minor variations in tubing wall thickness, giving extended tube life.
ROLLER ASSEMBLY COLLET SCREW 5MM HEX WRENCH 7 NT.M 60 IN.OZ
IMPORTANT: The 2001 Series is equipped with a pump cover for safety and protection against chemical spills. The cover must be installed whenever the pump is in use.
Flomotion Systems, Inc. 2001H Series
Page 7

2.1 Tubing, Spindle and Cover Installation

Pg. 7
! IMPORTANT: Disconnect pump controller from power supply BEFORE changing tubing!
Item No. Qty Part No. Description
1 1 n/a Pump Body 2 1 100511 Roller Assembly 3 1 100304B Cover 4 1 100324 Collet Screw 5 1 100305C Cover Gasket 6 4 100307C Cover Screw 7 1 varies Tubing 8 1 Varies with tubing selection* Tube Seal
2001H Series Peristaltic Pump O&M Manual
*Tube Seal PN
100329 100330 100331 100332 100333 100334
8
Tubing is shown bent forward out of the pump housing to illustrate the correct tubing and roller assembly position, prior to sliding the tubing and spindle into the housing and over the collet.
Flomotion Systems, Inc. 2001H Series
Page 8

2.2 Mounting Pump on Gearbox, Installation of Collet

Pg. 8
2001H Series Peristaltic Pump O&M Manual
Item No. Qty Part No. Description
1 1 na Pump Housing with Tube Seal & Tube
Seal Cover 2 1 100306 Collet 3 2 100312 Pump Mounting Screws 4 1 na Tubing
Flomotion Systems, Inc. 2001H Series
Page 9
2001H Series Peristaltic Pump O&M Manual
Pg. 9

2.3 Pump Mounting and Collet Installation Procedure

1. To install the pump housing on the gearbox, slide it over the central pilot on the gearbox adaptor plate. Next install and torque the mounting screws to 5 NT.M (45 in. oz).
2. Next install the collet on the gearbox shaft. There is a slot in the collet that the flat drive tang on the gearbox shaft must slide into. Orient the collet to allow the drive tang to slide into the slot and push the collet completely onto the gearbox shaft. When the collet bottoms out it is in the correct position.
Flomotion Systems, Inc. 2001H Series
Page 10
2001H Series Peristaltic Pump O&M Manual
Pg. 10

2.4 Tube and Roller Installation

! IMPORTANT: Disconnect pump controller from power supply BEFORE changing tubing!
! IMPORTANT Make sure pump suction and discharge lines are completely drained and isolated. Note that the tubing hose seal size must match the selected tubing size.
Disassembly
1. Remove four (4) 4mm pump cover screws.
2. Loosen Tube Seal Clamp Screw with 5mm hex
wrench.
3. Remove 5mm collet screw.
Flomotion Systems, Inc. 2001H Series
Page 11
4. Remove the roller assembly.
Pg. 11
5. Remove worn pump tubing from pumphead.
2001H Series Peristaltic Pump O&M Manual
6. Remove and inspect collet for wear. Note that the collet may remain in the roller assembly when the roller assembly is removed from the pump shaft.
Flomotion Systems, Inc. 2001H Series
Page 12
7. Clean inside of pump housing with damp rag or an
Pg. 12
appropriate cleaning solution to remove any chemical or tubing residue.
Reassembly
1. Reinstall the collet onto the pump shaft.
There is a slot in the collet that the flat drive tang on the gearbox shaft must slide into. Orient the collet to allow the drive tang to slide into the slot and push the collet completely onto the gearbox shaft. When the collet bottoms out it is in the correct position.
2001H Series Peristaltic Pump O&M Manual
2. Mark an 11” section of tubing, which will be the portion, contained within the pump. Leave sufficient excess on the suction and discharge sides of the pump for the desired connections. If you leave the excess intake tubing in a coil near the pump it will make it easy to feed a new section of tubing through the rollers when the section in the pump becomes worn.
Mark an 11”
section of pump tubing.
Flomotion Systems, Inc. 2001H Series
Page 13
3. Install tubing into the pumphead.
Pg. 13
Note: during tubing installation the loop of tubing may develop a twist. Examine the tubing for this condition and if needed turn one end of the tubing where it exits the tubing clamp to eliminate the twist. Correctly adjusted the tubing loop will be flat and parallel to the front face of the pump housing.
2001H Series Peristaltic Pump O&M Manual
4. Loop tubing around roller assembly between guides as shown. Remove slack in tubing while rotating roller assembly and sliding onto collet.
Flomotion Systems, Inc. 2001H Series
Page 14
5. Align marks on tubing with outside edge of the tubing
Pg. 14
Clamp.
6. Reinstall collet screw firmly.
2001H Series Peristaltic Pump O&M Manual
Mark an 11 inch length of tubing and locate the marks at the outside edge of the tubing seal (see arrows)
Tubing seal size varies with the selected tubing size. See tables on following pages for details
7. Tighten tubing seal clamp screw. Be sure to tighten firmly to prevent “tubing walk.” Tubing walk can occur when the tubing seal is the wrong size or is not sufficiently tight to keep the rollers from pulling the tubing through the pump as it rotates.
Align the tubing marks with the outside edge of the Hose Seal.
Flomotion Systems, Inc. 2001H Series
Page 15
8. Inspect pump cover gasket. Replace if damaged.
Pg. 15
Reinstall pump cover gasket and cover.
2001H Series Peristaltic Pump O&M Manual
Flomotion Systems, Inc. 2001H Series
Page 16
2001H Series Peristaltic Pump O&M Manual
Pg. 16

2.5 Tubing & Connections

Tubing adapters are available for many configurations. See the drawing below for details.
Hose Barb Color
Hose Seal PN
Violet Green White Black Gray Blue
100329 100330 100331 100332 100333 100334
Flomotion Systems, Inc. 2001H Series
Page 17

Tubing and Accessory Part Numbers

Pg. 17
FLOPRENE TUBING - 50 Ft Length (Santoprene) FLO.016.024 1.6mm (1/16”) bore 100 PSI max FLO.032.024 3.2mm (1/8”) bore 100 PSI max FLO.048.024 4.8mm (3/16”) bore 70 PSI max
CONNECTORS / ADAPTORS 1/2” NPTM x pump tubing (bore as required) 3/8” PE tubing x pump tubing (bore as required) Two-piece Color Coded tubing Barb & Collar Set.
PUMPHEAD tubing SEALS 100329 tubing Seal 1.6mm (1/16”) bore 100330 tubing Seal 3.2mm (1/8”) bore 100331 tubing Seal 4.8mm (3/16” bore
2001H Series Peristaltic Pump O&M Manual
FLO.064.024 6.4mm (1/4”) bore 50 PSI max FLO.080.024 8.0mm (5/16”) bore 30 PSI max FLO.096.024 9.6mm (3/8”) bore 30 PSI max
100332 tubing Seal 6.4mm (1/4”) bore 100333 tubing Seal 8.0mm (5/16”) bore 100334 tubing Seal 9.6mm 3/8”) bore
Flomotion Systems, Inc. 2001H Series
Page 18

3.0 – 2001H Motor & Gearbox

Pg. 18

3.1 Motor Specifications

Motor Type: Permanent Split Capacitor or 3-Phase Inverter Duty Rotation: Reversible. Insulation: Class B minimum Finish: Powder-coat gloss black.
Thermostat signal wires are not used in the 2001H
2001H Series Peristaltic Pump O&M Manual
3.2 2001H Power & Motor Wiring

3.3 Gearhead Specifications

Housing: Precision machined die cast aluminum. Lubrication: Lifetime oil bath, sealed and gasketed. Shafts: Hardened steel. Mounting: Face (any angle) or optional footplate. Gearing: AGMA class 9 heat treated steel. 1st stage helical metal, balance spur metal. Bearings: Needle with thrust ball.
Flomotion Systems, Inc. 2001H Series
Page 19
2001H Series Peristaltic Pump O&M Manual
Pg. 19

4.0 – K4 SERIES Pump Controller

4.1 Operation and Wiring

For complete details about the pump controller please refer to the included K4 SERIES (KBDA) Drive Controller Operating Instructions booklet.
Shown here are program settings specific to the operation with the 2001H Series Peristaltic Pump.

4.2 Programming

The K4 SERIES programming differs from the factory defaults shown in the Operating Instruction booklet in relation to the following parameters:
0.04 = 0000 GFCI operation disabled
1.00 = 0001 Remote Start/Stop input enabled
1.05 = 0003 Auto restart after power failure or fault
2.01 = 0001 Update speed change w/o having to press ENTER
2.02 = 0002 Local/Remote select input enabled
3.02 = 0100 100Hz Full Scale
4.00 = 0000 Display in Hz
5.00 = 0000 Run Relay output enabled
7.03 = 0010 Remote Start/Stop output enabled
7.04 = 0000 External Local/Remote select input OFF (0013 = ON)
7.06 = 0008 External Fault Input enabled
8.00 = 0001 Fault Relay output enabled
8.01 = 0009 Remote Status Output
9.07 = 0020 4-20mA Input enabled
8.09 = 0002 Enable fault when the 4-20mA output is disconnected*
6.05 = 1010 reset to Flomotion Defaults *8.09 = 0000 to avoid fault when 4-20mA Output is disconnected when not using 4-20mA output
Refer to section 4.3 for wiring and program for the above signals and functions.
Flomotion Systems, Inc. 2001H Series
Page 20

4.3 Interfacing to the 2001H K4 SERIES Pump Controller

Pg. 20
2001H Series Peristaltic Pump O&M Manual
Flomotion Systems, Inc. 2001H Series
Page 21
2001H Series Peristaltic Pump O&M Manual
Pg. 21

5.0 - 2001 Series Tubing Rupture Detector

Rupture Detector System Overview

5.1 Alarm Causes

A rupture alarm is triggered by the presence of a conductive fluid in the pump. When the fluid bridges the two stainless steel electrodes on the LIQUID SENSOR the alarm is triggered.

5.2 What to do in an alarm condition

To clear the alarm, first stop the pump and disconnect power from the pump controller. Remove the pump cover and remove the ruptured pump tubing. Clean the inside of the pump with a soft rag. Remove any liquid or tubing debris from the inside of the pump and the area around the LIQUID SENSOR. Inspect rollers and clean if necessary.

5.3 Resetting the alarm

Press the yellow pushbutton (LEAK INDICATOR & RESET SWITCH) on the top of the Tubing Rupture Detector to reset the alarm.
! IMPORTANT: Resetting the Tubing Rupture Detector will cause the pump to resume turning ! ! ALWAYS reinstall the pump cover BEFORE resetting the tubing rupture detector !

5.4 Resuming Service

Install a fresh tubing insert and the pump is ready to resume service.