Flomatic PVB 1 Specification

Pressure Vacuum Breaker Specification Submittal Sheet
Model PVB (3/4” & 1”)
FEATURES: Sizes: ¾” 1”
Max. working pressure: 150 PSI (1200 kPa) Max. working temperature: 140
Hydrostatic Test Pressure: 300 PSI (2400 kPa)
MATERIALS:
Valve Body: Bronze (ASTM B584) Access Cover: ABS Polymers: Noryl Elastomers: Silicone / Buna-n Springs: Stainless Steel
TM,
NSF Listed
°F (60°C)
OPTIONS:
B9510 or B9511 – less ball valves
UE – with union end ball valves
STANDARDS COMPLIANCE:
®
ASSE
Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of
Southern California
FLOMATIC SPECIFICATIONS:
Designed for installation on potable water lines to prevent against contaminated water backsiphonage into the potable water supply. Assembly shall provide protection against backsiphonage where a potential health hazard exist.
Listed 1020
Size A B C D E Width Wgt w/ BV Wgt no BV
Inch mm
¾ 20 B9500 6 152
1 25 B9501 6-1/2 165 7-1/8 181 5-1/16 129 5 127 3 76 4 102 4.25 2 1.5 .7
Part #
Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm lbs kg lbs kg
6-9/16
167 4-5/16 110 4-1/2 114 3 76 3-7/8 98 3.25 1.5 1.5 .7
Danfoss Flomatic
Danfoss Flomatic Corp, 15 Pruyn’s Island, Glens Falls, New York 12801
Phone: 518-761-9797 Fax: 518-761-9798 www.flomatic.com
November 22,2004 Rev. 3
Pressure Vacuum Breaker Specification Submittal Sheet
Model PVB (3/4” & 1”)
FLOW CHARACTERISTICS
a
P
k
10
69
S S O
48 7
L E
R
41 6
U S S
35
E R P
FLOW CURVES w/ BALL VALVES
i
s
p
962
855
5
428
321
214
17
0 10 60 gpm20
3/4" (20 mm)
30 40 50
FLOW RATE
1" (25 mm)
2.52.63 1.26 1.89 3.79 lps3.15
RATED FLOW
(Established by Approval Agencies)
TYPICAL INSTALLATION
Model PVB Pressure Vacuum Breaker should be installed with adequate clearance and easy accessibility for testing and maintenance and must be protected from freezing. Local codes shall govern installation requirements. Unless otherwise specified, the installation shall be in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. The installation shall be made so that no part of the unit can be submerged. Thermal water expansion can cause excessive pressure. Excessive pressure situations should be eliminated to avoid possible damage to the system and assembly.
Capacity thru Schedule 40 Pipe (GPM)
Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec
¾”
1”
8 12 17 25
13 20 27 40
WARRANTY: Danfoss Flomatic valves are guaranteed against defects of materials or workmanship when used for
the services recommended. If in any recommended service, a defect develops due to material or workmanship, and the device is returned, freight prepaid, to Danfoss Flomatic within 12 months from the date of purchase, it will be repaired or replaced free of charge. Danfoss Flomatics’ liability shall be limited to our agreement to repair or replace the valve only.
Danfoss Flomatic
Danfoss Flomatic Corp, 15 Pruyn’s Island, Glens Falls, New York 12801
Phone: 518-761-9797 Fax: 518-761-9798 www.flomatic.com
November 22,2004 Rev. 3