FLOJET G-57 Series Installation & Operation Instructions

Page 1
4.58
(116)
0.25 (6.4)
5.27
(134)
Air Exhaust
Muffler
2.20 (56)
1.84 (47)
0.92 (23)
0.71 (19)
3.21 (82)
4.52
(115)
5.81
(148)
Fluid OutFluid In
G-57 Series
40
(
2.8)
20
(1.4)
6
0
(4.1)
8
0
(5.5)
100
(
6.9)
Flow in GPM (l/min)
*Indicates Airlet Pressure
Pressure in PSI (Bar)
0
1.0
(3.8)
2.0
(7.6)
3.0
(11.4)
4.0
(15.1)
5.0
(18.9)
6.0
(22.7)
100*
80*
60*
40*
20*
Industrial Air Driven Pump
INSTALLATION & OPERATION INFORMATION FOR MODELS G573XXX THROUGH G575XX
PRODUCT DATA
Pump Design ............................................Duplex Diaphragm
etted Parts....Diaphragm Material Santoprene ® or Viton ®
W
Check Valve Seat Material
Santoprene ® or Viton ®
Housing and check valve material
................Polypropylene (Glass Reinforced)
Springs ..........................................Hastelloy
Ports ......................................Gas Inlet & Outlet 1/4” (6.3 mm)
Product Inlet 3/8” (9.5 mm) - 1/2” (12.7 mm) - 3/4” (19.1 mm)
Product Outlet 3/8” (9.5 mm) - 1/2” (12.7 mm) - 3/4” (19.1 mm)
Net Weight ..............................................1.2 Pounds (0.54kg)
® A registered trade mark of Monsanto Co. ® A registered trade mark of I.E. DuPont Co.
DESCRIPTION
FLOJET Industrial G-57 Series Pumps are designed for general commercial and industrial applications. These pumps are constructed from a selection of materials for handling a broad range of chemicals.
Allowed fluids for Not Allowed fluids for Santoprene ®materials Santoprene ®materials
Potable Water, Acids Oils, Solvents,Soaps with Alkaline, Soaps Solvents, D-Limonene, Alcohols, Ketones Aromatic Hydrocarbons
PERFORMANCE SPECIFICATIONS
PUMP
Liquid Temperature
...........................Max ......................................120°F (48.9°c)
.
Priming ..............Dry ..........................................15 ft. (4.5 m)
............................Wet ..........................................20 ft. (6.1 m)
Flow Rates ........Max ....................Up to 5 GPM (18.9 L/min)
Gas Supply Pressure ..............20 to 100 PSI (1.4 to 6.9 bar)
Noise Level ........Max ......................................................87dB
Santoprene and Viton Material with 1/2” Ports
Min ............................................40°F (4.4°C)
Allowed fluids for Not Allowed fluids for Viton ®materials Viton ®materials
Oils, Solvents, D-Limonene,
Ketones, Acetones,
Aromatic & Halogenated Automotive Brake Fluid,
ocarbons, Acids
Hydr
DIMENSIONAL DRAWING
Inches (millimeters)
Dimensional tolerances ± 0.06 inches Consult factory if precise details are required.
Ammonia, Ethanol
Page 2
MOUNTING
FLEXIBLE
HOSE
RIGID
PIPE
The FLOJET G-57 Series self-priming pump should be
ounted in a dry and adequately ventilated area. This
m pump can be mounted several feet from the tank, above or below the fluid level. For most applications, no more than 4 feet above the fluid level is recommended. This
is not a submersible pump.
Secure Dump to desired fixture by screws through the rubber grommets in the baseplate of the pump. Ports must be facing down. Contact factory for mounting bracket and hardware options.
HOSE CONNECTIONS
Product In - Use 3/8”. 1/2” or 3/4”. reinforced hose or equivalent. Avoid sharp bends that could restrict flow or cause hose to collapse under vacuum.
Product Out - Use reinforced 3/8”. 1/2” or 3/4” I.D. hose for discharge tube. 3/4” must use 90° elbows when using large muffler.
Gas In - Make sure gas regulator is set at zero. Use reinforced 1/4” hose. connect “Gas In” to gas supply fitting on regulator. If pumps are installed in an enclosed area, it is recommended to connect a hose to the gas discharge port (exhaust) and vent gas to atmosphere. (Requires ‘small’ exhaust port)
OPERATION
At start-up, regulate gas pressure to desired setting. For
ost installations 20 PSI (1.4 bar) inlet will be adequate,
m although DO NOT go below 20 PSI. Pump will operate according to air supply. Flow and pressure can be adjusted by increasing or decreasing gas pressure to accommodate varying product viscosities, length of
ines or other installation conditions. Review flow curves
l located on page 1 for further assistance. High viscosity fluids and hose length will limit priming distance.
IF PUMP IS T0 BE USED IN HIGH FLOW, LOW PRESSURE APPLICATIONS, ADJUST GAS PRESSURE TO 20 PSI (1.38 BAR) ABOVE DISCHARGE PRESSURE.
CAUTION: DO NOT EXCEED 100 PSI (6.9 bar) GAS INLET PRESSURE.
CONTINUOUS OPERATION AT 120°F (48.9°C) WILL REDUCE PUMP LIFE.
AIR MUST BE DRY AND OIL FREE.
Compressors must have dryers and/or a water separator in the air distribution system. Pumps that fail due to water in the air chamber will not be covered under the limited warranty.
GENERAL SAFETY INFORMATION
Protect yourself and others by observing all safety information. Follow all safety codes and the Occupational Safety and Health Act (OSHA).
PLUMBING
Use a flexible hose to avoid excess stress on pump ports. DO NOT crimp or kink hose. All hose should be the same size as the pump port fittings.
All fittings must be compatible with fluid being pumped. It is recommended to use plastic fittings only.
The use of check valves in the plumbing system could interfer unavoidable, check valves in the pumping system must have a cracking pressure of 2 PSI or less.
Use a minimum 40 mesh strainer or filter in the tank or pump inlet line to keep large foreign particles out of the system.
e with the priming ability of the pump. If
WARNING
DO NOT PUMP GASOLINE OR FLAMMABLE LIQUIDS OR USE WHERE FLAMMABLE VAPORS ARE PRESENT.
If used with C0
or N2be sure the area is
2
well ventilated.
CAUTION:
Do not clean or service FLOJET pumps, hoses or valves while the system is pr ports do not have a check valve. Prior to cleaning or servicing, purge the pump by carefully tilting the pump so ports are facing up and remove suction line from source. Turn air off and disconnect air inlet line. (Brass air inlet ports have a check valve)
essurized. Plastic CO
PREVENTIVE MAINTENANCE TIPS
Tips to help pr
• If pumping liquid other than water. pump should be flushed with water (if applicable) after every use.
Before freezing conditions occur. pump must be liquid free.
• If mounting pump in an outdoor environment. shield pump from environmental extremes (i.e. sunlight. water from washdown spray, rain, etc.).
• When using an air compressor. use an inline air dryer before the pump to limit water build-up.
olong your pump’s life.
air inlet
2
Page 3
2
B
2
A
5
4 3A
6
3
A
4
5
7
1A
1
A
6
6
2
B
2
A
MODEL G57 SERIES EXPLODED VIEW
Key Part No. Description Qty
1A 20740-050A Kit, Check Valve, Assy., Santo ®, Hastelloy 4
1B 20740-020A Kit, Check Valve. Assy., Viton ®, Hastelloy 4 2A 20730-000A Kit, Diaphragm, Santo,&, w/“O” rings 2 2B 21000-209 Kit, Diaphragm, Viton
®
3A 20751-000A Kit, Shaft & Slide Valve Assy. (Santo ®)2 3B 20751-002A Kit, Shaft & Slide Valve Assy. (Viton ®) 2
4 20896-000A Kit, Flange & Housing Assy. w/“O” Ring 2 5 20753-000A Kit End Caps 2
G57 DISASSEMBLY PROCEDURE
First, remove all gas (air in) lines and suction/discharge fittings from me pump. This is accomplished by using a flat-bladed
ewdriver to slide the r
scr and suction/discharge fittings and pulling the fittings away from the pump body. Now remove the muffler by sliding the retaining clip away from the muffler base and pulling the muffler out of the pump body.
UsIng a Phillips screw driver remove the seven (7) screws from the front end cap followed by the (7) screws from the rear end cap. With the fr on the workbench, position a flat bladed scr
ont end cap facing up and the r
located above the muffler port and just below the pad marked Air/C0 removed by placing the flat bladed screwdriver under the fully
and lift off the front end cap. The rear end cap can be
2
opened port retaining clip and lifting off.
Note the position of the suction and discharge valves before removing them from the pump body. The first diaphragm is
emoved fr
r
om the pump shaft by unscrewing in a counter clock­wise direction. The second diaphragm is removed by placing the flat tip of a screwdriver the exposed slot at the end of the pump shaft and unscr
ewing me diaphragm fr flange housing, place the tip of the flat bladed scr air bleed hole on the lower side of the flange housing and lift up the lower end separating the flange housing from the pump body.
The slide valve assembly and pump shaft can be removed by sim­ply pulling them from the pump body. The pump shaft then can be removed from the slide valve yoke assembly.
etaining clips away from the gas (air in)
ear end cap facing down
ew driver into the slot
om the shaft. T
ew driver into the
emove the
o r
Key Part No. Description Qty
6 20793-100A Kit Hardware - Includes
Screws #10x1.5” Hi Low 14 Retainer Clip Small 2
2
Retainer Clip Large 2 Exhaust Port 1 Exhaust Muffler 1
7 20132-000 Kit, Grommets 2
REASSEMBLE PROCEDURE
Assemble the slide valve and pump shaft with the yoke placed between the (2) bumpers on the pump shaft. Install the slide valve/pump shaft assembly into the pump body making sur O-rings in the slide valve ar prelube the o-ring with Parker Super “O” Lube and install on flange housing and place housing over the pump body aligning the flange housing with the pump body ribs pressing it into place.
e in place. T
o install the flange housing,
Install the first diaphragm and O-ring on to the pump shaft by threading on to shaft using a flat blade screwdriver to hold the pump shaft until the diaphragm is tight. Install the second diaphragm and O-ring on to the pump shaft tur
ning clockwise until
tight.
Install the suction valves with springs facing into the pump body and the discharge valves with the springs facing out. See arrows on pump rear end cap below suction and discharge ports.
Install the port retainer clips (large) into the pump end cap (mounting base) and install the seven (7) Phillips screws into pump body and cr
oss tighten until snug and then cr
oss torque to 22-24 inch pounds. Install port retaining clips (small) into the pump body, tabs facing out, position the front end cap and install the seven (7) Phillips scr then cr
Install the muf r
etainer clip into place. Install the suction and discharge ports and
ews into pump body and cr
oss tor
que to 22-24 inch pounds.
fler in the center port by pushing it in and sliding the
oss tighten until snug and
the (air in) port fitting and slide the retainer clips in place. Check for leaks.
e the
Page 4
MODEL NUMBERING MATRIX
G57X XX X X
Elastomer/ Ports Air Inlet/ Packaging
Spring Material (Product in and out) Muffler Code
5 SANTO Diaphragm 00 No Port Fittings 5 Straight brass 1/4” A (single pack)
S
ANTO Check Valve 20 Straight 3/8” HB 6 Elbow 90° brass 1/4” D (72 bulk pack) EPDM O-Rings 21 Straight 1/2” HB 7 Tee brass 1/4” Hastelloy Springs 22 Straight 3/4” HB 8 Straight Plastic 1/4”
2
3 VITON
VITON
®
Diaphragm 24 Elbow 90° 1/2” HB *(no muffler element)
®
Check Valve Seat 25 Elbow 90° 3/4” HB
3 Elbow 90° 3/8” HB 9 Straight Plastic 1/4”*
Hastelloy Springs
TROUBLESHOOTING CHART
Symptom Possible Cause(s) Corrective Action
Pump will Pump will not start (stalls) 1. Inadequate air supply (20 PSI Min.) 1. Increase air inlet pressure
Pump runs, but no fluid
Pump leaks through exhaust port 1. Leak at upper exhaust port o-ring (13) 1. Replace exhaust port (13)
Flow rate is low 1. Tubing or hose is damaged or blocked 1. Clean or replace
Pump leaks 1. Ruptured or worn out diaphragm (2) 1. Replace diaphragm (2)
2. Contaminated air supply 2. An air dryer might be required
3. Ruptured diaphragm (2) 3. Replace diaphragm (2)
4. Check shuttle valve for wear (11) 4. Replace shuttle valve if necessary (11)
1. A leak or break in the product inlet line 1. Replace product line
2. A leak or break in the product discharge line 2. Replace product line
2. Shaft seal o-rings damaged or worn 2. Replace shaft seal o-rings
3. Inadequate slide lubrication 3. Replace with shuttle valve kit
2. Check viscosity of medium being pumped 2. Reduce viscosity of medium, increase hose diameter or contact factory for recommendation
3. Check valves not seated correctly (6) 3. Reinstall check valves (6)
Pump housing screws not torqued adequately
2.
2. Torque screws to 20 in lb
G57 PORT FITTINGS
PART DESCRIPTION QTY
NUMBER
20381-002 1/2” HB, Straight, EPDM “O” Ring 2 20381-006 3/4” HB, Straight, EPDM “O”Ring 2 20381-009 1/2” HB, 90° Elbow, EPDM “O” Ring 2
For a complete port fitting list please request form No. F1 00-112.
WARRANTY
FLOJET warrants this product to be free of defects in material and/or workmanship for a period of one year after purchase by the customer from FLOJET. During this one year warranty period, FLOJET will at its option, at no charge to the customer, repair or replace this product if found defective, with a new or reconditioned product, but not to include costs of removal or installation. No product will be accepted for return without a return material authorization number. All return goods must be shipped with transportation charges prepaid. This is only a summary of our Limited Warranty. For a copy of our complete warranty, please request Form No. 100-101.
U.S.A. Flojet 666 E. Dyer Rd. Santa Ana, CA 92705 Phone: 714.557.4700 Fax: 714.628.8478
Copyright 2006, ITT Industries
UNITED KINGDOM Flojet Bingley Road, Hoddesdon Hertfordshire EN11 OBU
el:
T Fax: +44 (0) 1992 467132
+44 (0) 1992 450145
CANADA Fluid Products Canada 55 Royal Road Guelph, Ontario N1H 1T1 Tel: 519 821.1900 Fax: 519 821.2569
Printed in U.S.A.
PART DESCRIPTION QTY
NUMBER
20381-010 3/4” HB, 90° Elbow, EPDM “O” Ring 2 20325-033 1/4” HB, Straight Plastic (Air In) 12 01510-000 1/4” HB, Straight Brass (Air In) 12
RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service for an authorization number. This number must be written on the outside of the shipping package. Place a note inside the package with an explanation regarding the reason for return as well as the authorization number. Include your name, address and phone number.
www.flojet.com
AN
JAP NHK Jabsco Company Ltd. 3-21-10, Shin-Yokohama Kohoku-Ku, Y
el:
T Fax: 045.475.8908
All Rights Reserved
okohama, 222
045.475.8906
GERMANY Jabsco GmbH Oststrasse 28 22840 Norderstedt Tel: +49-40-53 53 73 -0 Fax: +49-40-53 53 73 -11
Form: 82000-014
Y
AL
IT Jabsco Marine Italia Via Tommaseo, 6 20059 V Tel: +39 039 685 2323 Fax: +39 039 666 307
cate, Milano
imer
Rev
. C 08/2006
Loading...