FLOJET 2100-12, 2100-694, 2100-740, 2100-750 Specifications

Page 1
FEATURES
• Self-Priming
• Dry Running
• Automatic Operation
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing. CE Models
are fully suppressed.
Pump: Two chamber diaphragm design; Self-priming
up to 6 ft. suction lift; Pump able to run dry without damage.
Port: Pump housing inlet and outlet are 3/8” NPT
female threads.
Duplex Diaphragm Design
Models2100 Series
Automatic Water System Pump &
Shower Drain • General Purpose Pump
Model 2100 Series
Pump Series Dimensions - Inches (mm) Weight
Height Width Length lb. (kg)
2100-XXX 3.75 (95) 3.25 (83) 8.2 (208) 3.3 (1.5)
AMP DRAW FUSE FLOW
MODEL* VOLTS @ 10 psi (0.7 bar) AMPS GPM (l/min) ON OFF
2100-12 12V dc 2.5 7 2.3 (8.7) 15 (1) 30 (2)
2100-694** 12V dc 2.5 7 2.3 (8.7) No Pressure Switch
2100-740 24V dc 1.5 5 2.3 (8.7) 15 (1) 30 (2)
2100-750 12V dc 2.5 7 2.3 (8.7) 15 (1) 30 (2)
*CE fully suppressed models are identified by a prefix “R” and a CE mark on the label. (i.e. R2100-740) Self Declaration Of Conformance (SDOC) is available upon request. **Shower Drain Model only
OPERATION FOR
ATER SYSTEM PUMPS
W
, does not include por
t connectors, see Accessories to or
OPERATION FOR THE SHOWER DRAIN PUMP
PRESSURE SWITCH PSI (BAR)
der connectors.
The FLOJET 2100 series pumps are automatic demand pumps. They will automatically tur
f when all fixtur
opened and tur
When starting from a completely drained system allow time for the demand pump to fill the hot water tank. After refilling the tank the pump is reprimed by opening a fixture. Allow air to vent and close fixture when water flow is steady. Faucet strainers and aerators should be cleaned regularly.
n of
n on when a fixtur
e closed.
es ar
e is
Model 2100-694 is a utility/shower drain pump. The
our shower drain
f automatically
pump will not tur pump is designed to self-prime up to 6 feet suction lift (vertical distance from shower pan to pump inlet). It is
ecommended you utilize a “lighted” on-of
r that pump is tur able to run dry (no liquid) for extended periods with no damage to the pump, however this could cause needless batter
n of
ned of
y drain.
f when not in use. The pump is
. Y
f switch so
Page 2
(+)Red (+)
Fuse
Switch
Battery
(–)
Black (–)
Pumpgard
Water
Tank
Jabsco
City Water
Entry
Water
Heater
Check
Valve
TM
B
A
Flojet Shower
Drain Pump
Install Strainer Inlet Side Only
AUTOMATIC WATER SYSTEM INSTALLATION
INSTALLATION
STEP 1
Remove shipping plugs from pump ports. Some water from factory testing may spill out.
STEP 2
Install inlet A and discharge B port connectors.
STEP 3
Insert rubber mounting grommets onto base plate.
STEP 4
Mount pump vertically, with pump head down or horizontally in an accessible location. Do not compress grommets.
SHOWER DRAIN INSTALLATION
Model 2100-694
STEP 5
Use 1/2” or 3/8” I.D. flexible hose (preferably braided or reinforced). Use hose clamps on the slip-on barb hose connectors.
STEP 6
Install no less than 3/8” I.D. hose for feed lines to fixtures. Use high pressure hose on all city water lines.
STEP 7
Install a Flojet strainer in an accessible location (for inspection and cleaning) between the tank and pump inlet. This strainer or equivalent is required for pump warranty to be valid.
WIRING
In an easily accessible location, install a switch to control electricity to the pump. Turn the pump off when not in use for extended periods, or when tank is out of water.
A 7 amp. fuse should be installed in the positive line with the pump being its only load. (24V model, use 5A fuse).
Wire size based on total wire length.
0 - 20 ft.
20 - 50 ft.
50 - 80 ft. #12 AWG
#16 AWG
WG
#14 A
Page 3
TROUBLESHOOTING
4
5
5 73
19
2
WARNING: BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM!!
Pulsating Flow - Pump cycles on and off
• Restricted pump delivery. Check discharge lines, fittings and valves for clogging or undersizing.
Failure to Prime - Motor operates, but no pump discharge
• Restricted intake or discharge line. Open all fixtures, check for “jammed” check valve poppets and clean clogged lines
• Air leak in intake line
• Punctured pump diaphragm
• Defective pump check valve
• Crack in pump housing
• Debris in check valves
Motor Falls To Turn On
• Pump switch in off position
• Loose wiring connection
Blown fuse
• Pressure switch failure
Defective motor
Pump Falls to Turn Off After All Fixtures Are Closed
• Empty water tank
• Insufficient voltage to pump (low battery)
• Discharge line leak
• Defective pressure switch
• Punctured pump diaphragm
Low Flow and Pressure
• Air leak at pump intake
• Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm
• Defective motor
Quite often when a pump is worn or defective the one failed component has overburdened others. To avoid frequent aggravating
DISASSEMBLE
Pressure Switch
1. Remove switch (9). Disconnect switch wires.
2. Loosen four pump head screws and carefully remove upper housing assembly (1)
Upper Housing
Follow steps 1 and 2
3. Inspect check valve (2) for debris
4. Reassemble new upper housing (1)
Check Valve Assembly
Follow steps 1 and 2 Replace check valve (2)
3.
4. Reassemble upper housing (1)
Lower Housing, Diaphragm, Motor
Follow steps 1 and 2, then remove 2 recessed screws.
3. Rotate lower housing (4) so drain notch opening on lower housing near baseplate exposes set screw which holds bearing housing to shaft.
4. Loosen this set screw by inserting wrench 1/8” Allen wrench into drain notch opening. Then, slide lower housing (4) of motor shaft.
Diaphragm Cont’d
5. Loosen two cam piston screws with Phillips head screw driver and pull apar always be replaced when a new diaphragm is installed.)
Motor Cont’d
5. Replace Motor
repairs, Flojet offers service kit assemblies making repairs as quick and easy as possible.
REASSEMBLE
Motor
1. Reassemble lower housing assembly (4) to motor. (Follow steps 4 to 10.)
Diaphragm
2. Lower housing is assembled with:
• Flat side of diaphragm and outer pistons facing motor
• Hex stem of inner pistons must be aligned into hex holes in outer pistons (4).
Outer pistons must be aligned with alignment slots on cam
• assembly making sure screw holes align in cam assembly, otherwise diaphragm will leak.
ews par
ews secur
. Set scr
ely
alve
ead or strip out thr
om inner pistons. (Pistons should
t cam fr
ighten cam piston scr
T
3. diaphragm, then tighten scr
Lower Housing
4. Reassemble lower housing assembly (4) to motor. Retighten set scr
5. positioned facing motor covering seam (indentation). (Positioning of this screw is critical to avoid misalignment and subsequent diaphragm damage.)
Upper Housing, Check V
f
6. Reassemble upper housing (1)
7. Properly seat O-Ring in check valve assembly (2) and check if ferrules and screen are in place on upper housing (1)
Install check valve (2) into upper housing (1) and push in.
8. Assemble on to lower housing (4), align 4 screws on to motor
9. by rotating lower housing (4) if necessary.
ighten scr
T
10.
essur
Pr
1. Place switch against front of pump (9), insert screws and take car
Reconnect wir
2.
e Switch
e not to cr
ew secur
ews evenly to 30 in. lbs. tor
oss thr
es.
, center piston in
tially
ely (18 in. lbs. tor
ew head must be
que.
eads in housing.
que)
Page 4
PUMP SERVICE PARTS
MODEL #
KEY DESCRIPTION 2100-12 2100-694 2100-740 2100-750
7 Motor 12V 2009-004C 2009-004C 2009-004C 7 Motor 24 V 2019-001A
Pump Service Kit 21046-057 21046-057 21046-057 Pump Ser
vice Kit 21046-121
9 Pressure Switch Assy. 2095-105 2095-105 2095-105
*Ser
vice Kit
Pump Service Kit includes item #2, 3, 5 and 6.
**CE fully suppressed motors are available, order R2009-004C or R201 9-001 A respectively.
ACCESSORIES PORT CONNECTORS (NYLON)
Part Number Pump Connection Plumbing Connection
91010-001 3/8” NPT (m) X 3/8” Hose Barb 90° Elbow
91010-002 3/8” NPT (m) X 3/8” Hose Barb Straight
91010-005 3/8” NPT (m) X 1/2” Hose Bar 90° Elbow
91010-006 3/8” NPT (m) X 1/2” Hose Barb Straight
91010-056 3/8” NPT (m) X 1/2” Male QEST Straight
STRAINERS
Pump Series Strainer Number Inlet Outlet Screen
2100-XXX 1740-003 3/4 Barb 3/4 Barb 40 Mesh
1740-002 1/2 Barb 1/2 Barb 40 Mesh 1740-004 1/2 M Qest 1/2 M Qest 40 Mesh
WARRANTY
FLOJET warrants this product to be free of defects in material and/or workmanship for a period of one year after purchase by the customer from FLOJET. During this one year warranty period, FLOJET will at its option, at no charge to the customer, repair or replace this product if found defective, with a new or reconditioned product, but not to include costs of removal or installation. This is only an overview of our limited warranty. If you would like a copy of our warranty, please call or write FLOJET.
RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service for an authorization number. This number must be written on the out­side of the shipping- package. Place a note inside the package with an explanation regarding the reason for return as well as the authorization number. Include your name, address and phone number.
www.flojet.com
U.S.A. Flojet 20 Icon Foothill Ranch, CA 92610 Tel: 949.859.4945 Fax: 949.859.1153
Copyright 2005, ITT Industries
UNITED KINGDOM Flojet Bingley Road, Hoddesdon Hertfordshire EN11 OBU Tel: +44 (0) 1992 450145
+44 (0) 1992 467132
Fax:
Printed in U.S.A.
CANADA Fluid Products Canada 55 Royal Road Guelph, Ontario N1H 1T1
el: 519 821.1900
T Fax: 519 821.2569
JAPAN NHK Jabsco Company Ltd. 3-21-10, Shin-Yokohama Kohoku-Ku, Yokohama, 222
045.475.8906
el:
T Fax: 045.475.8908
All Rights Reser
ved
GERMANY Jabsco GmbH Oststrasse 28 22840 Nor T Fax: +49-40-53 53 73 -11
derstedt
el: +49-40-53 53 73 -0
m: 81000-127
For
ITALY Jabsco Marine Italia Via Tommaseo, 6 20059 Vimercate, Milano
el: +39 039 685 2323
T Fax: +39 039 666 307
Rev. B 07/2005