No parts of the software including source code may be reproduced, transmitted, transcribed or translated into any language or computer language in any
form or by any means, electronic, magnetic, optical, manual or otherwise,
without the prior written permission of Teledyne FLIR LLC.
The documentation must not, in whole or part, be copied, photocopied, reproduced, translated or transmitted to any electronic medium or machine-readable form without prior consent, in writing, from Teledyne FLIR LLC. Names
and marks appearing on the products herein are either registered trademarks
or trademarks of Teledyne FLIR LLC and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are used for identification only and are the property of their respective owners.
1.2 Quality Assurance
The Quality Management System under which these products are developed
and manufactured has been certified in accordance with the ISO 9001 standard. Teledyne FLIR LLC is committed to a policy of continuous development;
therefore, we reserve the right to make changes and improvements on any of
the products without prior notice.
1.3 Documentation
To access the latest manuals and notifications, go to the Download tab at:
https://support.flir.com. It only takes a few minutes to register online. In the
download area you will also find the latest releases of manuals for our other
products, as well as manuals for our historical and obsolete products.
1.4 Disposal of Electronic Waste
As with most electronic products, this equipment must be disposed
of in an environmentally friendly way, and in accordance with existing
regulations for electronic waste. Please contact your Teledyne FLIR
LLC representative for more details.
#NAS100060; r. AB/80750/80750; en-US
1
Page 8
2
Introduction
Thank you for selecting the VS290–2x or VS290–3x Thermal Videoscope kit.
The kit includes one VS290–00 Videoscope Display, accessories, and one of
the following camera probes:
• VSC–IR21 Thermal Camera Probe with 19 mm diameter Round Tip (Forward View).
• VSC-IR32 Thermal MSX
View).
• VSC-IR33 Thermal MSX
Round Tip (Side View).
The Thermal Videoscope kit is the first industrial inspection Videoscope with
Thermal, Visual, and MSX technology. It is a rugged, high quality, and reliable
visual inspection instrument that improves productivity and reduces diagnostic time for facility diagnostics, utilities, manufacturing, public safety, and inspection service industries.
Please update the VS290–00 Videoscope Display’s firmware, as explained in
Section 14, before first use and periodically thereafter, to ensure optimum
performance.
Please register your purchases and review the product warranty before use,
see Section 15.
®
CAT IV Camera Probe with Rectangle Tip (Side
®
CAT IV Camera Probe with 19 mm diameter
2.1 Supplied Items and Accessories
The kit includes the following:
• Videoscope Display
• Camera probe
• Li ion rechargeable batteries (2)
• Battery charger (two bays)
• AC power supply
• USB-C cable
• SD card
• Software: License card for ‘FLIR Thermal Studio Standard’, 1 Year
Subscription
• Wrist strap
• Hard-shell carry-case for all items
• Printed Quick Start document
#NAS100060; r. AB/80750/80750; en-US
2
Page 9
2
Introduction
2.2 Product Features
• 160 x 120 IR imaging resolution.
• MSX (Multi-Spectral Dynamic Imaging) on VSC-IR32 and VSC-IR33
probes.
• Thermal IR-only camera on VSC-IR21 probe.
• Probes include flexible points and are low-profile.
• -10℃ to 400℃ (14℉ to 752℉) temperature range.
• 57° x 44° field of view (FOV).
• Automatic hot/cold spotting and Isotherm (color) alarms.
• CAT IV 600 V safety rating (VS290-32 and VS290-33 only).
• IP67 rated camera probe (IP54 rated Videoscope Display).
• LED worklight (VSC-IR32 and VSC-IR33 probes only).
• Longer than five (5) hours of battery operation on one charge.
#NAS100060; r. AB/80750/80750; en-US
3
Page 10
3
Safety
3.1 Safety Notes
• Before operating the device, you must read, understand, and follow all instructions, dangers, warnings, cautions, and notes.
• FLIR Systems reserves the right to discontinue models, parts or accessories, and other items, or to change specifications at any time without prior
notice.
• This product conforms to UL STD 61010-1 and is certified to CSA STD
C22.2, no. 61010-1.
WARNING
This product is a battery operated digital thermal camera intended for special use. The kit
includes the VS290–00 Videoscope Display, camera probe, and accessories as listed in
the Specifications section.
The VS290-32 and VS290-33 are suitable for use in CAT IV 600 V environments.
The VS290-21 is not intended for use in high voltage (> 600 V AC) environments. Personal
injury, damage to the camera, and damage to external equipment can result.
WARNING
• Do not operate the device if you do not have the correct knowledge. Incorrect operation
of the device can cause damage and injury to persons.
• Do not use the device if it show signs of damage. Injury to persons can occur.
• Be careful working near voltages > 25 V AC or 35 V DC. There is a risk of shock from
these voltages. Injury to persons can occur.
CAUTION
Battery Safety
Do not incinerate or disassemble batteries. Batteries can explode or otherwise release
toxic materials.
Do not short circuit batteries, this may cause burns.
Attention. Ne pas incinérer ni démonter les piles. Les batteries peuvent exploser
ou libérer des matières toxiques.
Ne court-circuitez pas les piles, cela pourrait provoquer des brûlures.
#NAS100060; r. AB/80750/80750; en-US
4
Page 11
3
Safety
WARNING
FCC Warnings. Applicability: Class B digital devices.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced Radio / TV technician for help.
Unlicensed band: This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may be
cause by unintended operation.
(15.21): Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.
CAUTION
• Do not point the infrared camera at strong energy sources, such as the sun, as this can
have an undesirable effect on the camera accuracy and can cause camera damage.
• Use caution when cleaning the camera lens as the lens has a protective coating that is
easily damaged.
• Do not use excessive force when cleaning the camera lens. Damage to the protective
lens coating can occur.
NOTE
The encapsulation rating on the VS290–00 Videoscope Display is only applicable when all
the openings are sealed with their correct covers, hatches, or caps. This includes the compartments for data storage, batteries, and connectors.
#NAS100060; r. AB/80750/80750; en-US
5
Page 12
4
Product Description
4.1 Videoscope Display Description
Figure 4.1 VS290–00 Videoscope Description
1. Camera display
2. Image and video Gallery button
3. LED worklight button
4. Navigation pad. Menu button (centre) and navigation buttons (outer ring)
5. Return button (exit a menu)
6. Power button (long press)
7. USB connector and memory card compartment
8. Collar screw locks probe to VS290–00
9. Probe connector
10. Probe release tab
11. Probe
12. Image and video capture trigger
13. Handle grip
14. Battery in battery compartment
#NAS100060; r. AB/80750/80750; en-US
6
Page 13
4
Product Description
4.2 Control Buttons
The four control buttons and navigation pad are explained below.
4.2.1 Power Button
Long press the power button to switch the instrument ON or OFF.
4.2.2 Return Button
Press the Return button to exit or move backward in the programming menu.
4.2.3 Gallery Button
Press the Gallery button to access the stored images and video. Press the
Return button
to exit the gallery.
4.2.4 Worklight Button
Press the Worklight button to switch the probe tip light ON or OFF (not available on VSC-IR21 probe).
4.2.5 Navigation Pad
Figure 4.2 Navigation Pad. Menu button (centre) and outer navigation buttons (left/right, up/
down).
Press the centre button to open the main menu and use it in the menus to
make selections. Use the outer navigation buttons to move up/down and left/
right in the program menus.
#NAS100060; r. AB/80750/80750; en-US
7
Page 14
4
Product Description
4.3 Top Compartment
Open the top flap to access the USB connector and the SD card slot.
Figure 4.3 Accessing the USB connector and SD card in the top compartment.
4.4 VSC-IR21 Thermal Camera Probe
The VSC-IR21 is an IR-only, general purpose, round forward-looking probe.
The VSC-IR21 probe is not intended for use in high voltage (> 600 V AC)
environments.
Always update the VS290–00 Videoscope Display’s firmware, as explained in
Section 14, before connecting a new probe, to ensure optimum performance.
CAUTION
Ensure that the VS290–00 is powered off before removing or attaching probes. Do not attempt to remove or attach a probe with the VS290–00 powered up.
Note that the release tab (item no. 10 in Figure 4.1) must be pushed to release
a probe from the Videoscope display when removing it.
Figure 4.4 VSC-IR21 camera probe.
1. Thermal camera lens
2. Camera body
3. Probe
#NAS100060; r. AB/80750/80750; en-US
8
Page 15
4
Product Description
4.5 VSC-IR32 Thermal MSX Camera Probe
The VSC-IR32 is a thermal MSX, rectangular, side-looking probe. It is suitable
for use in CAT IV 600 V environments.
Always update the VS290–00 Videoscope Display’s firmware, as explained in
Section 14, before connecting a new probe, to ensure optimum performance.
CAUTION
Ensure that the VS290–00 is powered off before removing or attaching probes. Do not attempt to remove or attach a probe with the VS290–00 powered up.
Note that the release tab (item no. 10 in Figure 4.1) must be pushed to release
a probe from the Videoscope display when removing it.
Figure 4.5 VSC-IR32 camera probe.
1. Thermal camera lens
2. Digital camera lens
3. LED worklight
4. Probe
4.6 VSC-IR33 Thermal MSX Camera Probe
The VSC-IR33 is a thermal MSX, side-looking, round probe. It is suitable for
use in CAT IV 600 V environments.
Always update the VS290–00 Videoscope Display’s firmware, as explained in
Section 14, before connecting a new probe, to ensure optimum performance.
CAUTION
Ensure that the VS290–00 is powered off before removing or attaching probes. Do not attempt to remove or attach a probe with the VS290–00 powered up.
Note that the release tab (item no. 10 in Figure 4.1) must be pushed to release
a probe from the Videoscope display when removing it.
#NAS100060; r. AB/80750/80750; en-US
9
Page 16
4
Product Description
Figure 4.6 VSC-IR33 camera probe.
1. Probe
2. LED worklight
3. Digital camera lens
4. Thermal camera lens
4.7 Display Description
Figure 4.7 Videoscope display.
1. Battery status
2. USB active
3. Worklight active
4. Cross-hairs. Target a surface spot to measure its temperature. See Sec-
tion 7.6, Measurements Menu, for additional cross-hairs functionality
5. Highest temperature sensed in the current camera image
6. Range of the selected display colour palette. In the Above/Below Alarm
Colour modes, alarm alerts are represented here
7. Lowest temperature sensed in the current camera image
8. Main menu icons
#NAS100060; r. AB/80750/80750; en-US
10
Page 17
4
Product Description
9. Thermal MSX alignment sliders. Vertical and horizontal sliders are used to
align the super imposed thermal and digital camera images. The horizontal slider is obstructed in the image above
Note that the VSC-IR21 does not include MSX, digital camera, or worklight
features.
10. Temperature reading of targeted spot. In Hot/Cold Spot modes, this area
will show the MAX or MIN temperature (see Section 7.6, MeasurementsMenu, for more)
#NAS100060; r. AB/80750/80750; en-US
11
Page 18
5
Battery Charging and Use
This kit is supplied with two high capacity batteries, a stand-alone two-bay
charger, and an AC adaptor. To charge batteries, place them in the charger,
connect the charger bay to the AC adaptor, and then plug the adaptor into an
AC receptacle. The LED indicators on the charger flash while a battery is
charging and glow steadily when fully charged. It may require up to 2 hours
for a full charge if a battery is completely drained.
Once charged, place a charged battery into the battery compartment and long
press the power button
pears informing that the battery voltage is low, charge the battery immediately.
to power the instrument. If an error message ap-
Figure 5.1 Installing and removing a battery.
#NAS100060; r. AB/80750/80750; en-US
12
Page 19
6
Quick Steps
These steps are provided to provide a simple overview. Please read the entire
User Manual before putting these devices into professional operation.
CAUTION
The VS290–32 and VS290-33 are suitable for use in CAT IV 600 V AC environments. The
VS290-21 is not intended for use in high voltage (> 600 V AC) environments.
NOTE
Please update the VS290–00 Videoscope Display’s firmware, as explained in Section 14, before first use and periodically thereafter, to ensure optimum performance.
1. Insert a fully charged battery into the VS290–00 handle.
2. If the probe is purchased separately from the Videoscope Display, please
connect the probe to the Videoscope Display before proceeding. Ensure
that the VS290–00 is powered off before attaching or removing a probe.
Note that the release tab (item no. 10 in Figure 4.1) must be pushed to release a probe from the Videoscope display when removing it.
3. Long press the power button
4. When powered, the VS290–00 displays a camera image and several function indicators, dependant on the configuration of the instrument.
Figure 6.1 Viewing a camera image.
#NAS100060; r. AB/80750/80750; en-US
to power up.
13
Page 20
6
Quick Steps
5. Carefully position the probe into the area to be examined and view the
camera image on the display. Short press the worklight button
to switch
the light on/off (the worklight is not available on the VSC-IR21 probe).
Figure 6.2 Insert the probe into the test area.
6. To select an image mode, press the Menu button (centre), scroll to the Image Mode icon and press Menu again. Use the navigation buttons to select Thermal MSX, Thermal, or Digital camera; press Menu to confirm.
Note that the VSC-IR21 probe does not include MSX, digital camera, or
worklight features.
7. The cross-hairs allow you to target and measure the surface temperature
of a spot. The measurement is shown digitally (upper left). The thermal
scale for the current image is shown on the right edge of the display.
8. To capture an image or to stop/start a video, pull and hold the trigger.
Press the Gallery button
to view stored images and videos. Images/vid-
eos can be sent to a PC via USB.
#NAS100060; r. AB/80750/80750; en-US
14
Page 21
7
Programming Menus
7.1 Basic Navigation
Press the Menu button (centre) to open the main menu and the sub-menus.
Use the navigation buttons to scroll left/right and up/down. Use the Menu button (centre) to confirm a selection; press the Return button
7.2 Main Menu
The main menu options are: 1. Image Rotation, 2. Image Mode, 3. Color, 4.
Measurement, 5. Temperature Scale, and 6. Settings.
7.3 Image Rotation Menu
to exit a menu.
Figure 7.1 Accessing the Image Rotation mode.
Press Menu on the Image Rotation icon and use the navigation buttons to
select 90° rotation or horizontal/vertical flip of the camera image. Press Menu
to confirm.
Figure 7.2 Selecting 90° Rotation or Vertical/Horizontal Flip.
#NAS100060; r. AB/80750/80750; en-US
15
Page 22
7
Programming Menus
7.4 Image Mode Menu
Figure 7.3 Accessing the Image Mode menu.
Press Menu on the Image Mode icon and use the navigation buttons to
select: Digital, Thermal, Thermal MSX, or Alignment Distance.
Note that the VSC-IR21 probe does not include MSX, digital camera, or worklight features.
Thermal MSX (Multi-Spectral Dynamic Imaging) is an enhancement that improves image clarity by embossing visual scene details on the thermal image,
providing added context to accurately target potential issues. The MSX Alignment Distance option allows you to fine tune the embossed visual scene details using the vertical and horizontal sliders. See Figure 7.5 below.
Figure 7.4 Selecting the Thermal MSX, Thermal only, and Digital Camera modes.
#NAS100060; r. AB/80750/80750; en-US
16
Page 23
7
Programming Menus
Figure 7.5 Select the Thermal MSX mode and then the Alignment Distance option. Use the
sliders (left side and bottom of the display) to align the Digital Camera image with the Thermal
image. Use the left/right and up/down arrow buttons to make the adjustments.
For best results in darker areas, turn the worklight on when using MSX.
7.5 Color Palette Menu
Figure 7.6 Accessing the Color Palette mode.
To select a display color palette, press Menu on the Color icon and use
the navigation arrows to scroll. Press Menu when the desired color palette is
selected (Iron, Rainbow, Gray, Above Alarm, or Below Alarm).
In the Above/Below Alarm modes (known as ‘Isotherms’), you select a high
alarm set point (for Above Alarm mode) and a low alarm set point (for Below
Alarm mode). The colorations in the thermal image indicate the sections of
the test area that exceed the set point limit. Use the arrow buttons to set the
temperature limits (the set point is shown on the bottom of the display). The
vertical colour bar graph on the right side of the display indicates the degree
to which the alarm set point is exceeded. See Section 9, Isothermal Alarms,
for more.
#NAS100060; r. AB/80750/80750; en-US
17
Page 24
7
Programming Menus
Figure 7.7 Selecting a Color palette or an Isotherm Alarm (Above and Below) mode.
Figure 7.8 Isotherm Alarm examples.
7.6 Measurements Menu
Figure 7.9 Accessing the Measurements mode menu.
#NAS100060; r. AB/80750/80750; en-US
18
Page 25
7
Programming Menus
Navigate to the Measurement icon and press Menu. Select from the
available options, detailed below, and then press Menu to confirm.
• Centre Spot
. Target a surface spot with the cross-hairs to measure its
temperature. The temperature measurement is shown in the upper left corner of the display (digitally).
• Hot Spot
. Position the camera so that the rectangle display target is covering an area of interest. The cross-hairs will move to the hottest (MAX)
spot automatically (inside the rectangle target). The MAX temperature is
shown, digitally, in the upper left corner.
• Cold Spot
. Position the camera so that the rectangle display target is
covering an area of interest. The cross-hairs will move to the coldest (MIN)
spot automatically (inside the rectangle target). The MIN temperature is
shown, digitally, in the upper left corner.
• No Measurements.
Figure 7.10 Select a measurement type. Centre Spot for manual targeting (temperature displayed on upper left corner of display); Hot Spot for automatic targeting of hottest spot in the
target rectangle; Cold Spot for automatically targeting coldest spot in the rectangle; No Measurements for removing the temperature display digits.
#NAS100060; r. AB/80750/80750; en-US
19
Page 26
7
Programming Menus
7.7 Temperature Scale Menu
Figure 7.11 Accessing the Temperature Scale menu.
Navigate to the Temperature Scale icon and press Menu. Use the navigation buttons to select Auto (where the camera uses the entire thermal
range), or Lock (where you can freeze the range to a narrow thermal region).
Figure 7.12 Image on left shows Auto mode where the temperature range uses all of the
available spectrum. Image on right shows the Lock mode where the temperature range can
be constrained. To constrain the range, point to a spot in the frame that represents the temperature of interest, and then select the Lock mode.
7.8 Settings Menu Overview
The settings menu has four sub-menus: Recording mode, Measurement
parameters, Save options, and Device settings. See below.
#NAS100060; r. AB/80750/80750; en-US
20
Page 27
7
Programming Menus
7.9 Settings Menu
Figure 7.13 Accessing the Settings menu.
7.9.1 Recording Mode Sub-Menu
Press Menu on the Settings icon and press Menu again at the Recording
Mode sub-menu. Select Video or Single-shot using the navigation buttons
and press Menu to confirm. Pull and hold the trigger to start/stop a video recording or to capture a single image.
Figure 7.14 Select Video or Single shot (still image) mode. When the trigger is pulled, a video or a photo will be stored, depending on the selection made here.
#NAS100060; r. AB/80750/80750; en-US
21
Page 28
7
Programming Menus
7.9.2 Measurement Parameters Sub-Menu
Figure 7.15 Accessing the Measurement Parameters menu.
Press Menu on the Settings icon and press Menu again at the Measurement
Parameters sub-menu. Perform one or more of the steps below:
• Scroll to the Emissivity option and press Menu. Select a preset or choose a
custom emissivity setting.
Figure 7.16 Selecting an emissivity preset or a custom setting.
#NAS100060; r. AB/80750/80750; en-US
22
Page 29
7
Programming Menus
• Scroll to the Reflected Temperature option, press Menu, and set a reflected
temperature value.
Figure 7.17 Setting the Reflected Temperature value using the up/down arrow buttons.
• Scroll to the Atmospheric Temperature option, press Menu, and set an at-
mospheric temperature value.
Figure 7.18 Selecting the Atmospheric Temperature using the up/down arrow buttons.
7.9.3 Save Options Sub-Menu
Press Menu on the Settings icon and press Menu again at the Save Options
sub-menu. When set to ON, the camera stores two images (thermal and digital) for each Thermal MSX image captured. Use the navigation buttons to set
on/off and press Menu to confirm.
Note that the VSC-IR21 probe does not have MSX mode.
#NAS100060; r. AB/80750/80750; en-US
23
Page 30
7
Programming Menus
Figure 7.19 Determine if you’ll need a separate digital camera image along with each ther-
mal image captured.
7.9.4 Device Settings Sub-Menu
Figure 7.20 Accessing the Device Settings sub-menu.
Press Menu on the Settings icon and press Menu again at the Device Settings
sub-menu to begin programming or viewing the following items. Each menu is
explained in detail below.
#NAS100060; r. AB/80750/80750; en-US
24
Page 31
7
Programming Menus
• Set the Language, Time/Date, and Units of measure.
Figure 7.21 Selecting the user interface Language.
Figure 7.22 Setting the Date, Time, and Format.
Figure 7.23 Selecting the Temperature Units.
#NAS100060; r. AB/80750/80750; en-US
25
Page 32
7
Programming Menus
• Set individual Auto Power Off (APO) timers for the VS290–00 and the
worklight.
Figure 7.24 Setting the APO time for the VS290–00 and the worklight.
#NAS100060; r. AB/80750/80750; en-US
26
Page 33
7
Programming Menus
• Adjust the screen and worklight brightness.
Figure 7.25 Set the display and worklight brightness.
• View System information including serial number and firmware version. If
you require technical assistance, please note the serial number for the
base unit and probe, found in this menu, first, as you may be asked for this
information.
Figure 7.26 View the System Information.
#NAS100060; r. AB/80750/80750; en-US
27
Page 34
7
Programming Menus
• Reset Options. Revert to factory default conditions and/or format SD mem-
ory card. Note that the memory card cannot be formatted if a USB cable is
connected to the unit.
Figure 7.27 Reset the unit to factory default conditions and/or format SD memory card.
• View regulatory data.
Figure 7.28 Accessing the regulatory compliance information.
#NAS100060; r. AB/80750/80750; en-US
28
Page 35
8
Taking Measurements
NOTE
Before proceeding to put this device into professional operation ensure that all system, safety,
and programming information is well understood as explained in this user manual.
NOTE
Please update the VS290–00 Videoscope Display’s firmware, as explained in Section 14, before first use and periodically thereafter, to ensure optimum performance.
8.1 Charge and Install the Battery
As discussed in Section 5, Battery Charging, place the batteries in the supplied bay charger. Connect the charging bay to the supplied AC adaptor, and
then connect the AC adaptor to an AC source to begin charging.
Once charged, insert a battery into the VS290–00 and long press the power
button
8.2 Power-up Display Configuration
When you power up the VS290–00, the display will show the camera image
for the currently selected Image Mode (Thermal MSX, Thermal, or Digital
camera). The digits and icons that are displayed also depend on the configuration of the camera. See Section 4.5, Display Description, for details.
8.3 Programming the Instrument
Before taking measurements you’ll want to configure the instrument to best
match the application at hand. See the following parameter list for the most
commonly used options. Refer to Section 7, Programming Menus, for complete instructions on these and other options.
to power the instrument.
• Image Mode (Thermal MSX, Thermal-only Camera, or Digital Camera).
• Thermal display color palette.
• Measurement Mode (Color spot, Hot spot, Cold spot, or No
Measurements).
• Emissivity.
• User interface Language.
• Temperature units (℃ / ℉).
• Auto Power Off (APO) timers for the worklight and the VS290–00.
• Display and worklight brightness.
#NAS100060; r. AB/80750/80750; en-US
29
Page 36
8
Taking Measurements
8.4 Positioning the Probe into the Test area
CAUTION
The VS290-32 and VS290-33 are suitable for use in CAT IV 600 V AC environments. The
VS290-21 is not intended for use in high voltage (> 600 V AC) environments.
CAUTION
Ensure that the VS290–00 is powered off before removing or attaching probes. Do not attempt to remove or attach a probe with the VS290–00 powered up.
Note that the release tab (item no. 10 in Figure 4.1) must be pushed to release
a probe from the Videoscope display when removing it.
1. Carefully position the probe into the area to be examined, as shown in ac-
companying figure.
Figure 8.1 Inserting the probe into the test area.
#NAS100060; r. AB/80750/80750; en-US
30
Page 37
8
Taking Measurements
2. View the image for the area you are inspecting.
Figure 8.2 View the test area on the VS290–00 display.
3. Short press the worklight buttonto switch the light on/off if added illumi-
nation will help in your inspection work.
4. To select an image mode, press the Menu button (centre), scroll to the Im-
age Mode icon and press Menu again. Use the navigation buttons to select Thermal MSX, Thermal, or Digital camera; press Menu to confirm.
Note that the VSC-IR21 does not have an MSX or a digital camera mode.
5. The cross-hairs allow you to target and measure the temperature of a sur-
face area. The measurement is shown digitally (upper left). The thermal
scale for the current image is shown on the right edge of the display.
6. To capture an image or to stop/start a video, pull and hold the trigger.
Press the Gallery button
to view stored images and videos. Images/vid-
eos can be transported to a PC via USB.
7. The image orientation may be changed by rotating the probe. It can also
be changed by rotating the displayed image electronically (see section 7.3,
Image Rotation Menu).
#NAS100060; r. AB/80750/80750; en-US
31
Page 38
9
Isothermal Alarms
9.1 Isotherms Overview
Isotherm Alarms allow you to set a high and/or low temperature set point. The
image colorings show the areas that exceed the set point temperatures. To
configure the Isotherms, open the Color menu and select the desired alarm
mode. Use the navigation arrows to select the temperature set point. The hot
alarm color cold is red while the cold alarm color code is blue.
9.2 Isotherm Screen Shots
Figure 9.1 ‘Above Alarm’ (left) shows a high temperature alarm setup. The alarm set point is
shown on the bottom of the display (red), use the up/down arrows to adjust the set point. ‘Below Alarm’ (right) shows a low temperature alarm setup. The alarm set point is shown on the
bottom of the display (blue), use the up/down arrows to adjust the set point.
#NAS100060; r. AB/80750/80750; en-US
32
Page 39
10
Working with Images and
Video
10.1 General SD Card Usage Information
The SD card slot is located inside the VS290–00 top compartment. See illustration below. Do not remove or insert an SD card while the camera is powered. All images and videos that you capture will be stored on this card.
The supplied SD card is formatted at the factory, no formatting is necessary.
Do not use an SD card that has been formatted by another camera as the file
system may differ. To format an SD card, refer to the Reset Options paragraph
in Section 7.9.4, Device Settings Sub-Menu.
Figure 10.1 SD card slot in top compartment.
10.2 Capturing Images and Video
First select image mode (single-shot) or Video mode in the Recording Mode
sub-menu. To do so, press the Menu button to open the main menu, scroll to
the Settings icon (far right), and press Menu again. Press Menu a third time at
the Recording Mode sub-menu. Select Video or Single-shot using the navigation buttons and press Menu to confirm.
Pull and hold the trigger to capture an image or to start recording video. For
images, release the trigger when the filename appears. For video, release the
trigger when the video timer starts. Pull and hold the trigger to stop the video
#NAS100060; r. AB/80750/80750; en-US
33
Page 40
10
Working with Images and Video
recording. Note that images and video cannot be captured if a USB cable is
connected to the Videoscope.
Figure 10.2 Pull and hold the trigger to capture an image or start a video.
10.3 Viewing Images and Video
Press the Gallery button
to open the image/video gallery. Scroll to an image/video and press Menu to open it. Press Menu again at an opened image/
video to access these options: Play (video only), full screen mode, image/video information, and image/video delete.
10.4 Transferring Images and Video
Transfer to a PC by first connecting the VS290–00 to a PC using the supplied
USB cable (the USB connector is located in the VS290–00 top compartment),
and then use the VS290–00 as you would a typical external storage drive.
You can also transfer images and videos directly from the SD card. With the
camera power off, remove the SD card from the VS290–00 top compartment
and insert it into a standard SD card reader. Follow the instructions provided
by the SD card reader manufacturer.
#NAS100060; r. AB/80750/80750; en-US
34
Page 41
10
Working with Images and Video
Figure 10.3 The VS290–00 must be not be connected via USB, otherwise the error message
shown will appear when you attempt to capture an image or a video.
#NAS100060; r. AB/80750/80750; en-US
35
Page 42
11
MSX Imaging Technology
Note that the VSC-IR21 probe does not include MSX.
MSX (Multi-Spectral Dynamic Imaging) extracts scene details from the built-in
visual camera and embosses them onto the full thermal image. This allows
you to see the thermal image in context of the environment you are viewing.
The added context assists in accurately targeting potential problems in electrical, mechanical, and building applications.
For best results in darker areas, turn the worklight on when using MSX.
Press Menu on the Image Mode icon and use the navigation buttons to select
Thermal MSX. See the menu in Section 7.4, Image Mode, for complete programming details.
Figure 11.1 Thermal MSX image on left shows the detail from the digital camera image
superimposed on the thermal image. Image on right shows the thermal only version.
#NAS100060; r. AB/80750/80750; en-US
36
Page 43
12
Specifications
IMAGING AND OPTICAL SPECIFICATIONS
IR Resolution160 x 120 pixels
Digital image enhancementYes
Thermal sensitivity /NETD< 100 mK
Field of View (FOV)
Minimum focus distance0.15 m (5.9 in.); 0.65 m (25.6 in.) in MSX mode.
Image frequency8.7 Hz
IMAGE PRESENTATION
Display
Screen size3.5 in. (8.9 cm)
Color palettesIron, Rainbow, Gray, and Below/Above Alarms
Image modes
MEASUREMENT AND ANALYSIS
Object temperature range14℉ to 752℉ (-10℃ to 400℃)
Measurement accuracyAt ambient temperature. 15 to 35℃ (59 to 95℉) and object
Measurement options (spot
meter)
Emissivity correction3 presets and 1 custom setting
IMAGE STORAGE AND VISUAL (DIGITAL) CAMERA
Storage capacityRemovable SD card (16 GB)
Image/Video file formats
Digital camera resolution
Field of View (FOV)
WORKLIGHT
Worklight type
57° x 44°
320 x 240 pixel RGB LCD
IR only, visual only, MSX (Note that the VSC-IR21 probe
does not have an MSX or a visual camera mode)
temp. above 0℃ (32℉)
0 to 100℃ (32 to 212℉): ±3℃ (±5.5℉)
100 to 400℃ (212 to 752℉): ±3%
Centre spot, Hot spot, Cold spot, and No Measurement
modes
Image: Radiometric .jpg
Video: .mpeg-4
2 MP (not available on VSC-IR21 probe)
83°
Bright LED (not available on VSC-IR21 probe)
#NAS100060; r. AB/80750/80750; en-US
37
Page 44
12
Specifications
DATA COMMUNICATION
USBUSB Type-C for data transfer
BATTERY
Battery typeRechargeable 3.7 V Lithium ion
Battery operating time
DIMENSIONS AND WEIGHT
Weight (including battery)Complete VS290–21 kit with case: 5.4 kg (11.9 lbs.)
Dimensions
> 5 hours (full display brightness and worklight ON)
Complete VS290–32 kit with case: 13 kg (28.7 lbs.)
Complete VS290–33 kit with case: 13 kg (28.7 lbs.)
VS290–00 Videoscope Display: 640 g (1.4 lbs.)
VS290–21 kit with case (L x W x H): 54 x 35 x 17 cm (21.3
x 13.8 x 6.7 in.)
VS290–32 kit with case (L x W x H): 120 x 48 x 20 cm (47 x
18.9 x 7.9 in.)
VS290–33 kit with case (L x W x H): 120 x 48 x 20 cm (47 x
18.9 x 7.9 in.)
VS290–00 Videoscope Display: 26.4 x 11 x 11 cm (10.4 x
4.3 x 4.3 in.)
VSC-IR21 probe: 111.5 x 6.9 cm (43.9 x 2.7 in.)
VSC-IR32 probe: 212.2 x 0.69 cm (83.5 x 0.3 in.)
VSC-IR33 probe: 211.9 x 6.9 cm (83.5 x 2.7 in.)
VSC–IR21 and VSC–IR33 probe tip diameter: 19 mm (0.75
in.)
VSC–IR32 probe tip (L x W x H): 71.7 x 40.5 x 11 mm (2.8 x
1.6 x 0.4 in.)
#NAS100060; r. AB/80750/80750; en-US
38
Page 45
12
Specifications
SAFETY
Safety ComplianceGeneral Safety: Conforms to UL STD 61010-1; Certified to
CSA STD C22.2, no. 61010-1.
Environmental Safety: ETL (EN 61010-1), CE, UKCA, RCM,
FCC, WEEE, RoHS, REACH. Department of Energy and
California Title 20 Battery Charging Systems Efficiency.
Encapsulation: IP 67 (camera tip) and IP 54 (probe and Videoscope Display).
Electrical Safety: VS290-32 and VS290-33 are rated for
use in CAT IV 600 V AC environments. VS290-21 is not intended for use in high voltage (> 600 V AC) environments.
SUPPLIED EQUIPMENTAND ACCESSORIES
Videoscope display, camera probe, rechargeable batteries (2), battery charger, AC adaptor for charger, formatted SD card, USB cable, wrist strap, hard case, printed documentation, and complimentary FLIR Thermal Studio Standard one-year subscription.
#NAS100060; r. AB/80750/80750; en-US
39
Page 46
13
CUSTOMER SUPPORT
Customer Support Telephone Listhttps://support.flir.com/contact
Repair, Calibration, and Technical Supporthttps://support.flir.com
#NAS100060; r. AB/80750/80750; en-US
40
Page 47
14
Firmware Updates
Update the VS290–00 Videoscope Display firmware before use to ensure that
your probe(s) will operate optimally with the Videoscope Display. As new
probes are introduced into the product family, your Videoscope Display firmware may need an update to accommodate them.
The firmware files, and instructions for performing the update, are available at
the web address below:
https://support.flir.com
#NAS100060; r. AB/80750/80750; en-US
41
Page 48
15
Warranty and Product
Registration
15.1 2–10 Extended Warranty
To activate the extended 2–10 warranty, please register your product within 60
days of purchase. Otherwise, the standard one-year warranty will be in effect
from date of purchase. The 2–10 warranty covers parts and labour for the
camera for 2 years and coverage of the detector for 10 years.
Specifications subject to change without further notice. Models and accessories subject to regional market
considerations. License procedures may apply. Products described herein may be subject to US Export
Regulations. Please refer to exportquestions@flir.com with any questions.