R&D Departments
Compact thermal imaging
cameras for Research &
Development and Science
Universities
NEW
FLIR SC35 / SC15 / SC5 packs

FLIR SC35 / SC15 / SC5 packs
Compact thermal imaging camera packs for
Research & Development and Science
Thermal imaging cameras can be used for a wide variety of
R&D applications. Until today using a thermal imaging camera
was often the privilege for large R&D departments. With the
extremely affordable SC35 / SC15 and SC5 packs FLIR Systems
is now bringing the advantages of thermal imaging to the test
bench of every R&D engineer.
FLIR SC35 / SC15 and SC5 packages are not only extremely
affordable. They contain both the hardware and software for
analyzing and verifying your R&D projects. With the FLIR SC35 /
SC15 and FLIR SC5 packs you will be able to visualize temperature
and to measure temperatures in a non-contact mode.
Ax5 camera on table stand, using the goose neck mount,
which is included in the SCxx packs.
Extremely affordable
The FLIR A5 sc comes at an extremely
affordable price. It is the ideal tool for putting
thermal imaging at work in a R&D and Science
environment.
Extremely compact
All models are extremely compact. They can
easily be integrated in any environment.
Choice of image quality
The FLIR A35 sc produces crisp thermal images
of 320 x 256 pixels. Users that do not need this
high image quality for their application can
choose for the FLIR A15 sc which produces
thermal images of 160 x 128 pixels or for the
FLIR A5 sc which produces thermal images of
80 x 64 pixels.
GigE Vision™ standard compatibility
GigE Vision is a new camera interface standard developed using the Gigabit Ethernet
communication protocol. GigE Vision is the
rst standard to allow for fast image transfer using low cost standard cables even over
long distances. With GigE Vision, hardware
and software from different vendors can interoperate seamlessly over GigE connections.
GenICam™ protocol support
The goal of GenICam is to provide a generic programming interface for all types of
cameras. Regardless of interface technology
(GigE Vision, Camera Link, 1394 DCAM, etc.)
or features implemented, the Application
Programming Interface (API) will always be
the same. The GenICam protocol also makes
it possible to use third party software with the
camera. GenICam makes the FLIR A35 sc plugand-play when used with software packages
such as IMAQ Vision and Halcon.
Power over Ethernet (PoE )
Communication and power supplied with only
one cable.
Synchronization
Possible to congure one camera to be master
and others to be slave(s) for applications that
call for more than one camera to cover the
object or for stereoscopic applications.
General Purpose Input/Output (GPIO)
One output that can be used to control other
equipment and one input to read the status
from the same equipment.
...°C
...°C
...°C
...°C
Wide temperature range
The FLIR A xx sc-Series visualizes temperatures
between –40°C and +550°C.
2
Visit www.ir.com
HIGH
SENSITIVITY
< 50 mK
High sensitivity < 50 mK
< 50 mK thermal sensitivity captures the nest
image details and temperature difference
information.

Verication of PCB.
Development of car windscreen defrosting.
FLIR Tools+ software included
FLIR Tools+ software is included with every SCxx pack.
The FLIR thermal imaging cameras included in the FLIR
SC packs work seamlessly together with FLIR Tools+.
It allows for viewing, recording and analyzing thermal
images and includes functions such as time versus
temperature plots.
Each FLIR SCxx pack contains a thermal imaging camera, hard case, goose
neck with foot and 2 cable straps, 2 Ethernet cables, base mount, focusing
tool, PoE injector, and a power cable.
40 mm
106 mm
43 mm
Status LED
12-pole M12 connector
Ethernet connection
Available models
FLIR A35 sc FLIR A15 sc FLIR A5 sc
Resolution 320 x 256 pixels 160 x 128 pixels 80 x 64 pixels
Available lenses Focal length 9 mm Focal length 9 mm Focal length 5 mm
3

FLIR A35 sc / A15 sc / A5 sc
Technical specications
Imaging and optical data FLIR A35 sc FLIR A15 sc FLIR A5 sc
IR resolution 320 x 256 pixels 160 x 128 pixels 80 x 64 pixels
FOV (Field of view) / Focal length
Spatial resolution (IFOV) 2.78 mrad for 9 mm lens 5.56 mrad for 9 mm lens 10.0 mrad for 5 mm lens
Detector data
Detector pitch
General
Imaging and optical data
Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Minimum focus distance Fixed
F-number 1.25
Image frequency 60 Hz
Focus Fixed
Detector data
Focal Plane Array (FPA) / Spectral range Uncooled VOX microbolometer / 7.5–13 µm
Detector time constant Typical 12 ms
Measurement
Object temperature range –40°C to +160°C (–40 to 320°F) / –40°C to +550°C (–40 to +1022°F)
Accuracy ± 5ºC or ± 5% of reading
Ethernet
Ethernet Control and image
Ethernet, type Gigabit Ethernet
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, communication GigE Vision ver. 1.2
Ethernet, image streaming 14-bit signal linear/ DDE, GigE Vision and GenICam compatible
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0 Power
Ethernet, protocols TCP, UDP,ICMP, IGMP, DHCP, GigEVision
Digital input/output
Digital input, purpose General purpose
Digital input 1× opto-isolated, “0” < 2, “1”=2–40 VDC
Digital output, purpose General purpose Output to ext. device (programmatically set)
Digital output 1× opto-isolated, 2–40 VDC, max 185 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 2–40 VDC, max 200 mA
Digital I/O, connector type 12-pole M12 connector (shared with Digital Synchronization and External power)
Synchronization In, purpose Frame sync In to control camera
Synchronization In 1×, non-isolated
Synchronization In, type LVC Buffer @3.3V, “0” <0.8 V, “1”>2.0 V.
Synchronization Out, purpose Frame sync Out to control another Ax5 camera
Synchronization Out 1×, non-isolated
Synchronization Out, type LVC Buffer @ 3.3V, ”0”=24 MA max, “1”= –24 mA max.
Digital Synchronization, connector type 12-pole M12 connector (shared with Digital I/O and External power)
Power system
External power operation 12/24 VDC, < 2.5 W absolute max
External power, connector type 12-pole M12 connector (shared with Digital I/O and Digital Synchronization )
Voltage Allowed range 10–30 VDC
Environmental data
Operating temperature range –15°C to +50°C (+5°F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
EMC EN 61000-6-2 (Immunity)
Encapsulation IP 40 (IEC 60529)
Bump 25 g (IEC 60068-2-29)
Vibration 2 g (IEC 60068-2-6)
Physical data
Weight 0.2 kg (0.44 lb.)
Camera size (L × W × H) 106 × 40 × 43 mm (4.2 × 1.6 × 1.7 in.)
Tripod mounting Optional with Accessory T198349, Base support
Base mounting 4 × M3 thread mounting holes (bottom)
Housing material Magnesium and aluminum
Scope of delivery
Packaging, contents Thermal imaging camera with lens, getting started guide, important information guide, user documentation CD-ROM,
48° (H) x 39° (V) with 9 mm lens 48° (H) x 39° (V) with 9 mm lens 44° (H) x 36° (V) with 5 mm lens
25µm 50µm 50µm
Client API GenICam compliant
EN 61000-6-3 (Emission)
FCC 47 CFR Part 15 Class B (Emission)
registration card, Tools+ (scratch card), hard case, goose neck+foot+2xcable straps, 2x ethernet cables, base mount, focusing
tool, PoE Injector+mains cables
FLIR Systems Sweden
Tel.: +46 (0)8 753 25 00
Fax: +46 (0)8 753 23 64
FLIR Commercial Systems
Luxemburgstraat 2
2321 Meer
Belgium
Tel. : +32 (0) 3665 5100
Fax : +32 (0) 3303 5624
e-mail: ir@ir.com
Specications are subject to change without notice. Weights and dimensions are indicative. Imagery used for illustration purposes only.
Copyright 2012 FLIR Inc. All other brand and product names are trademarks of their respective owners.
FLIR Systems UK
Tel.: +44 (0)1732 220 011
Fax: +44 (0)1732 843 707
FLIR Systems Germany
Tel.: +49 (0)69 95 00 900
Fax: +49 (0)69 95 00 9040
FLIR Systems France
Tel.: +33 (0)1 60 37 01 00
Fax: +33 (0)1 64 11 37 55
FLIR Systems Italy
Tel.: +39 (0)2 99 45 10 01
Fax: +39 (0)2 99 69 24 08
FLIR Commercial Systems
Tel. : +34 91 573 48 27
Fax.: +34 91 662 97 48
FLIR Systems, Middle East FZE
Tel.: +971 4 299 6898
Fax: +971 4 299 6895
FLIR Systems Russia
Tel.: + 7 495 669 70 72
Fax: + 7 495 669 70 72
www.ir.com
T820482_{EN-EN}_A