Flexible Solutions HS115 User Manual

Flexible Solutions
HS115 Automatic Metering System
Owner's Manual
Installation, Operation & Parts
Furnish this manual to the end user of this
metering system; its use will reduce service calls
and chance of injury and will lengthen system life
Flexible Solutions
1
HS115 Automatic Metering System
To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY!
This manual describes how to install, setup, operate and maintain the HS115 Automatic Metering System (AMS). Material in this manual is subject to change without notice. Manual revisions will be made on an as needed basis. Special circumstances involving important design, operation or application information will be released via Equipment Technical Bulletins.
Table of Contents
Safety .................................................................. 2
General Information .................................................................. 3
Specifications .................................................................. 3-4
Installation .................................................................. 4-7
Setup & Programming .................................................................. 7-9
Maintenance .................................................................. 9-11
Troubleshooting .................................................................. 11-13
Warranty .................................................................. 13
Ordering Information .................................................................. 13
Safety
These are the safety alert symbols. When you see these symbols on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
CAUTION warns you about hazards that will or can cause minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which are important but not related to hazards.
These symbols on the unit mean:
Direct Current
Alternating Current
2
General Information
The HS115 is an Automatic Metering System for the application of Heatsavr™, the original liquid solar pool cover. It is a reliable, accurate, inexpensive way to ensure that your pool receives all the energy savings possible from using Heatsavr™.
Figure 1a. HS115
Figure 1b. HS115 D-Cell
Battery Unit
Swimming pool
Calculation Example
30'
40'
1,200 / 400 = 3 oz. / day
Hot Tub
Calculation Example
The HS115 is a time-activated, water-resistant peristaltic pump. Up to 24 events may be programmed with variable run times for each event from 1 second to 20 minutes. The HS115 operates a 7-day clock in which events can be programmed to occur every day or only on particular days throughout the week. A back up battery keeps the clock running in the event of an interruption in the electrical power. The Automatic Metering System is sold complete with two peristaltic pump tubes and additional accessories included (See Accessories). The HS115 is available for use with 115VAC, 230VAC or with a D-cell battery pack.
The manufacturer recommended dosage rate for Heatsavr™ is 1 oz/400 square feet of pool surface area per day. And 1 oz/50 square feet of Hot Tub and Spa surface area per day. The higher temperature in Hot Tubs require a higher dosage rate. The dosage is daily as the product is biodegradable. Each system can be programmable to exactly fit the surface area of your pool. Calculate the surface area of your pool (Width x Length) and divide by 400 square feet (50 square feet in Hot Tubs). This will calculate the daily amount of Heatsavr™ (in ounces) necessary for your specific swimming pool. For example, a 1,200 sq ft swimming pool will require 3 ounces per day.
The best application time is in the evening, once the swimming pool is closed to the public or when the swimming pool is experiencing less use.
Installation is very simple and the metering system is durable and easy to maintain.
10' D
'
10' Diameter:
3.14 x (5x5) = 78 oz.
78 / 50 = 1.5 oz. / day
Specifications
Operating Conditions
Ambient Operating Temperature: 35 to 104°F (5 to 40°C) Altitude: <2000 meters (6500 feet) Humidity: 0 to 100% relative humidity (non-condensing) throughout temperature range.
Electrical Power Options
115VAC 50/60 Hz +/- 10% 230VAC 50/60 Hz +/- 10% 4 D-cell battery powered
Rating
Pollution Degree: 2 Installation Category II Intended for indoor use. Outdoor use requires an All Weather Cover to be installed
Timing Capability
Up to 24 different times. Daily, weekly, or mixed schedule; variable run time 1 second to 19 minutes and 59 seconds.
3
Dimensions & Weight 115 VAC / 230 VAC Version
Height Width
1
Depth
2
Weight
5.6” 4.6” 4.8” 1.85 lbs
14.2 cm 11.6 cm 12.2 cm 0.84 kg
D-Cell Battery Powered Version
Height Width Depth Weight
3
5.6” 8.4” 4.8” 1.57 lbs
14.2 cm 21.3 cm 12.2 cm 0.72 kg
Components
Enclosure: Molded ABS plastic, water-resistant, flame-resistant Pump: Peristaltic, self-priming and self-checking, 6 Volts DC
Speed & Displacement
When pumping Heatsavr™: 100 rpm, 3 oz per min (90 ml per min)
Hydraulic Performance
Maximum Vacuum: 8” of mercury Maximum Pressure: 20 psi
Tubing Material
Flex, 1/4” OD, 1/8” ID
Coin Battery
3 Volt Lithium BR2032 or CR2032 (installed)
Refer installation and service
to qualified personnel only.
Installation must comply with
all applicable plumbing and
electrical codes.
The HS115 can also be mounted
using the three plastic feet. If
mounting on an uneven
surface, be careful not to over-
tighten or snap the feet off.
Accessories
1 Thread-on cap with 90º barb fitting
1 Bottle insert with pick up tube
1 Check valve injection fitting
2 Flex squeeze tube
25 Feet of polyethylene feed line
Mounting screws
Zip Tie wraps
Regulatory
For confirmation of regulatory compliance, see rating label on unit.
Installation
Before beginning, turn off the pools' circulation system and drain the isolated area where you will be drilling and tapping a hole into the main return line.
Mounting:
The HS115 should be mounted so the LCD screen can be viewed easily. It should be located close enough to both the injection point and liquid supply to ensure unobstructed delivery. If possible, mount out of direct sunlight to prevent UV damage.
1. Choose a place to mount the system near a power outlet and the pool main return line.
1 Width includes feet 2 Depth with Snap Heat pump cartridge in place 3 Weight does not include batteries
4
Loading...
+ 9 hidden pages