HS115 Automatic Metering System
To avoid unneeded service calls, prevent possible injuries, and get the most
out of your pump, READ THIS MANUAL CAREFULLY!
This manual describes how to install, setup, operate and maintain the HS115
Automatic Metering System (AMS). Material in this manual is subject to
change without notice. Manual revisions will be made on an as needed basis.
Special circumstances involving important design, operation or application
information will be released via Equipment Technical Bulletins.
Table of Contents
Safety .................................................................. 2
General Information .................................................................. 3
Specifications .................................................................. 3-4
Installation .................................................................. 4-7
Setup & Programming .................................................................. 7-9
Maintenance .................................................................. 9-11
Troubleshooting .................................................................. 11-13
Warranty .................................................................. 13
Ordering Information .................................................................. 13
Safety
These are the safety alert symbols. When you see these symbols
on your system or in this manual, look for one of the following
signal words and be alert to the potential for personal injury.
CAUTION warns you about hazards that will or can cause minor personal
injury or property damage if ignored.
The label NOTICE indicates special instructions which are important but not
related to hazards.
These symbols on the unit mean:
Direct Current
Alternating Current
2
General Information
The HS115 is an Automatic Metering System for the application of Heatsavr™,
the original liquid solar pool cover. It is a reliable, accurate, inexpensive way to
ensure that your pool receives all the energy savings possible from using
Heatsavr™.
Figure 1a. HS115
Figure 1b. HS115 D-Cell
Battery Unit
Swimming pool
Calculation Example
30'
40'
1,200 / 400 = 3 oz. / day
Hot Tub
Calculation Example
The HS115 is a time-activated, water-resistant peristaltic pump. Up to 24
events may be programmed with variable run times for each event from 1
second to 20 minutes. The HS115 operates a 7-day clock in which events can
be programmed to occur every day or only on particular days throughout the
week. A back up battery keeps the clock running in the event of an
interruption in the electrical power. The Automatic Metering System is sold
complete with two peristaltic pump tubes and additional accessories included
(See Accessories). The HS115 is available for use with 115VAC, 230VAC or with
a D-cell battery pack.
The manufacturer recommended dosage rate for Heatsavr™ is 1 oz/400
square feet of pool surface area per day. And 1 oz/50 square feet of Hot Tub
and Spa surface area per day. The higher temperature in Hot Tubs require a
higher dosage rate. The dosage is daily as the product is biodegradable. Each
system can be programmable to exactly fit the surface area of your pool.
Calculate the surface area of your pool (Width x Length) and divide by 400
square feet (50 square feet in Hot Tubs). This will calculate the daily amount
of Heatsavr™ (in ounces) necessary for your specific swimming pool. For
example, a 1,200 sq ft swimming pool will require 3 ounces per day.
The best application time is in the evening, once the swimming pool is closed
to the public or when the swimming pool is experiencing less use.
Installation is very simple and the metering system is durable and easy to
maintain.
10' D
'
10' Diameter:
3.14 x (5x5) = 78 oz.
78 / 50 = 1.5 oz. / day
Specifications
Operating Conditions
Ambient Operating Temperature: 35 to 104°F (5 to 40°C)
Altitude: <2000 meters (6500 feet)
Humidity: 0 to 100% relative humidity (non-condensing) throughout
temperature range.
Electrical Power Options
115VAC 50/60 Hz +/- 10%
230VAC 50/60 Hz +/- 10%
4 D-cell battery powered
Rating
Pollution Degree: 2
Installation Category II
Intended for indoor use.
Outdoor use requires an All Weather Cover to be installed
Timing Capability
Up to 24 different times. Daily, weekly, or mixed schedule; variable run time 1
second to 19 minutes and 59 seconds.
3
Dimensions & Weight
115 VAC / 230 VAC Version
Height Width
1
Depth
2
Weight
5.6” 4.6” 4.8” 1.85 lbs
14.2 cm 11.6 cm 12.2 cm 0.84 kg
D-Cell Battery Powered Version
Height Width Depth Weight
3
5.6” 8.4” 4.8” 1.57 lbs
14.2 cm 21.3 cm 12.2 cm 0.72 kg
Components
Enclosure: Molded ABS plastic, water-resistant, flame-resistant
Pump: Peristaltic, self-priming and self-checking, 6 Volts DC
Speed & Displacement
When pumping Heatsavr™: 100 rpm, 3 oz per min (90 ml per min)
Hydraulic Performance
Maximum Vacuum: 8” of mercury
Maximum Pressure: 20 psi
Tubing Material
Flex, 1/4” OD, 1/8” ID
Coin Battery
3 Volt Lithium BR2032 or CR2032 (installed)
Refer installation and service
to qualified personnel only.
Installation must comply with
all applicable plumbing and
electrical codes.
The HS115 can also be mounted
using the three plastic feet. If
mounting on an uneven
surface, be careful not to over-
tighten or snap the feet off.
Accessories
• 1 Thread-on cap with 90º barb fitting
• 1 Bottle insert with pick up tube
• 1 Check valve injection fitting
• 2 Flex squeeze tube
• 25 Feet of polyethylene feed line
• Mounting screws
• Zip Tie wraps
Regulatory
For confirmation of regulatory compliance, see rating label on unit.
Installation
Before beginning, turn off the pools' circulation system and drain the isolated
area where you will be drilling and tapping a hole into the main return line.
Mounting:
The HS115 should be mounted so the LCD screen can be viewed easily. It
should be located close enough to both the injection point and liquid supply to
ensure unobstructed delivery. If possible, mount out of direct sunlight to
prevent UV damage.
1. Choose a place to mount the system near a power outlet and the pool
main return line.
1 Width includes feet
2 Depth with Snap Heat pump cartridge in place
3 Weight does not include batteries