Flex PB6W User Manual

Product Data Sheet
FLEX GREEN GUARD PB6W FAN FOLD
ROOFING RECOVERY BOARD
PRODUCT DESCRIPTION
Flex Green Guard PB6W Fan Fold is the first and only fan folded roofing recovery board that combines moisture resistance, exceptional layflat and all plastic construction. Its innovative design offers contractors easy installation, labor/time savings and long-term performance.
USES Flex Green Guard PB6W Fan Fold can be used in both mechanically attached and loose-laid and ballasted roofing systems.
FEATURES AND BENEFITS
· Provides reliable on-the-job performance.
· Resists moisture damage, swelling or warping.
· Plastic facers help protect roofing membrane from penetration damage due to foot and mechanical
traffic.
· Lightweight, easy to install 4x 50 fan fold bundles unfold quickly to cover a 200 square foot area of
roof and can be cut with a common utility knife.
· Significant installation time and labor savings.
· Flex Green Guard PB6W Fan Fold features an advanced cut-and-fold hinge. Fan Fold lays flat over
most existing roof systems whether smooth or gravel surfaced.
DIMENSIONS/PACKAGING
Thickness (inches) 0.375 Bundles/Pallet 30 Square Feet/Bundle 200 Bundle Dimensions (feet) 4 x 50 Square Feet/Pallet 6000
PHYSICAL PROPERTIES: Property Test Procedure Specification
R-Value¹ (°F-ft²-h/Btu @ 75°F) C518 1.5 Water Vapor Transmission Rate (perm) E96 (Procedure A) 0.06 Water Absorption² (% Vol.) C272 0.06 Compressive Strength D1621 15 (Avg. psi @ 10% Deflection) Fire Characteristics³ E84/UL723 Flame Spread 10 Smoke Developed 45-140 Maximum Recommended Constant Use Temperature (°F) 200 Average Weight (1lbs./1000 sq. ft.) 105
¹Specimens are aged and tested in accordance with FTC R-Value Rule (16 CFR, Part 460). ²Due to the imprecision of the test method, values can be expected to range between 0.0 and the value shown. ³These numerical flame spread and smoke ratings are not intended to reflect hazards presented by this material under actual fire conditions. Core data.
_____________________________________________________________________________________________________
Flex Membrane International Corp. 2670 Leisczs Bridge Road, Suite 400, Leesport, PA 19533
Tel: (610) 916-9500 Fax: (610) 916-9501 www.FlexRoofingSystems.com
Page 1
FLEX GREEN GUARD 3/8 PB6W COMPLIANCE
Agency/Organization Report/Standard Number
ASTM Specification Non Applicable Building Officials and Code Administrators International Inc. (BOCA) 95-44 California Bureau of Home Furnishings License Number (CA BHF) TB 1334 Canada-Underwriters Laboratories, Inc. (Roof System Approvals/Listings) See ULC Product
Directory Factory Mutual Systems Approvals (FM) See FM Roofing Materials Directory International Conference of Building Officials (ICBO) 4280 Minnesota Department of Energy, Chapter 7640 Yes Southern Building Code Congress International, Inc. (SBCCI PST & ES) 9736 Underwriters Laboratories, Inc. (UL) Classification Certificate A184 Underwriters Laboratories, Inc. (UL) Roof System Approvals/Listings See UL Roofing Materials Directory
STORAGE
When stored outdoors, all material should be protected from exposure to direct sunlight using an opaque light-colored tarp or the original packaging. Material that has been unwrapped should be carefully rewrapped.
COAL TAR PITCH ROOF SYSTEMS
Flex Green Guard PB6W Fan Fold can be installed directly over existing coal tar roof systems if the roof has not been resaturated within the previous 4 years (otherwise use a polyethylene separator sheet between the Flex Green Guard PB6W and the existing roof system.) In addition, the new roof system must be designed to limit the maximum coal tar temperature to 110°F to prevent volatiles from escaping from the existing system and attacking the Flex Green Guard PB6W. The design temperature at the surface of the Flex Green Guard PB6W installed over existing coal tar pitch roofs shall not exceed 165°F during installation or use.
WARNING
Although Flex Green Guard PB6W Roofing Recovery Board contains a flame retardant additive intended to inhibit a small source fire, it, like most commercially available plastic foam insulations, is combustible and should not be exposed to flame or other ignition sources. This material may constitute a fire hazard if improperly used.
LIMITED WARRANTY
The manufacturer believes the information and recommendations herein to be accurate and reliable. However, since use conditions are not within its control, the manufacturer does not guarantee results from use of such products or other information herein and disclaims all liability from any resulting damage or loss. No warranty, express or implied, is given as to the merchantability, fitness for particular
purpose, or otherwise with respect to the products referred to
.
_____________________________________________________________________________________________________
Flex Membrane International Corp. 2670 Leisczs Bridge Road, Suite 400, Leesport, PA 19533
Tel: (610) 916-9500 Fax: (610) 916-9501 www.FlexRoofingSystems.com
Page 2