Flavel Caress, Slimline SC Installation And Maintenance Instructions Manual

Page 1
Caress
Slimline SC
COAL EFFECT GAS FIRE
Installation and Maintenance Instructions
Hand these instructions to the user
Model No’s FNVC**SN is for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B. / I.E.
Page 2
CONTENTS
Section 1 Information and Requirements PAGE
1.0 Appliance Information 3
1.1 Conditions of Installation 4
1.2 Flue and chimney suitability 4
1.3 Fireplace / surround suitability 5
1.4 Shelf position 5
1.5 Chimney inspection 5-6
1.6 Fire place opening / catchment space 6
1.7 Fitting to Chair bricks 8
1.8 Precast Flues 8
1.9 Metal Flue boxes 8
1.10 Hearths 9
1.11 Spillage Monitoring System 9
Section 2 Installation of Fire
2.1 Unpacking the fire 10
2.2 Installing the fire box 10-16
2.3 Gas tightness and burner pressure 17
Section 3 Assembling Fuel Bed and Commissioning
3.1 Assembling the ceramics and fuel bed 18-21
3.2 Fitting the Caress trim 22
3.3 Fitting the fret 23
3.4 Lighting the appliance 24
3.5 Checking for clearance of combustion products 25-26
Section 4 Maintenance
4.1 Removal of the Burner Assembly 27
4.2 Removal of the Battery Ignitor 28
4.3 Repacing the Battery 28
4.4 Removing the Oxy-Pilot Assembly 28
4.5 Replacing the Control Cable 29-30
This appliance is manufactured by:-
BFM Europe Ltd, Trentham Lakes, Stoke-on-Trent, ST4 4TJ
2
Page 3
SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APPLIANCE INFORMATION
Model FNVC**SN ** denotes trim & fret variant Gas Type G20
Main injectors (2 off) Size 235
Pilot Type S.I.T. Oxystop
YA OP 9055
Max. Gross Heat Input : 6.5 kW Min. Gross Heat Input : 4.2 kW
Cold Pressure : 20.0 +/-1.0 mbar (G20)
Ignition : 1.5V Battery Generator
Electrode Spark Gap 4.0mm
Weight 15.5 kg Chrome, 16.5kg Brass
Fire box Dimensions (with trim fitted)
Width : (with standard trim, no spacer) 510mm Height : (with standard trim, no spacer) 625mm Depth : (overall-with fender) 140mm Depth : Flush-fit (from mounting face to rear) 105mm
Gas Connection 8mm Compression (Supplied with fire)
Efficiency Declaration
The efficiency of this appliance has been measured as specified in BS 7977-1 : 2002 and the result is 51.5%. The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by Advantica. The efficiency value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
3
Page 4
INSTALLATION REQUIREMENTS
1.1 CONDITIONS OF INSTALLATION
In Great Britain :-
It is the law that all gas appliances are installed only by a CORGI Registered Installer, in accordance with these installation instructions and the Gas Safety (Installation and Use) Regulations 1998 as amended. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to comply with the law.
The installation must also be in accordance with all relevant parts of the Local and National Building Regulations where appropriate, the Building Regulations (Scotland Consolidation) issued by the Scottish Development Department, and all applicable requirements of the following British Standard Code of Practice.
1. B.S. 5871 Part 2 Installation of Inset Live Fuel Effect Gas Fires
2. B.S. 6891 Installation of Gas Pipework
3. B.S. 5440 Parts 1 & 2 Installation of Flues and Ventilation
4. B.S. 1251 Open fire place components
5. B.S. 715 Metal flue pipes for gas appliances
6. B.S. 6461 Part 1 Installation of Chimneys and flues
7. B.S. 1289 Clay Flue Blocks and Terminals
8. I.S. 813 : 1996 Domestic Gas Installation (Republic of Ireland)
In Republic of Ireland :-
No purpose made additional ventilation is normally required for this appliance, when installed in G.B. When Installing in I.E. please consult doc­ument I.S. 813 : 1996 Domestic Gas Installation, which is issued by the National Standards Authority of Ireland. If installing in Northern Ireland, please consult local building regulations. Any purpose made ventilation must be checked periodically to ensure that it is free from obstruction.
1.2 FLUE AND CHIMNEY SUITABILITY
This appliance is designed for use with conventional brick built or lined chimneys and fabricated flues. It is also suitable for use with pre-cast flue blocks conforming to B.S. 1289 and metal flue boxes conforming to BS 715. All flues must conform to the following minimum dimensions.
Minimum diameter of circular flues 125 mm (Without Flue
Restrictor Fitted) Minimum effective height of all flue types 3 metres When fitting to conventional chimneys or 175mm flues it may be desirable to fit the flue restrictor baffle (supplied) to reduce the flue flow and increase the efficiency of the fire. Safe clearance of products must always be checked by carrying out a smoke match test as described.
4
Page 5
1.3 FIREPLACE / SURROUND SUITABILITY
The fire must only be installed on a hearth it must not be installed directly onto carpet or other combustible floor materials.
The fire is suitable for fitting to non-combustible fire place surrounds and propri-
etary fire place surrounds with a temperature rating of at least 150oc.
If a heating appliance is fitted directly against a wall without the use of a fire surround or fire place all combustible material must be removed from behind the trim. Soft wall coverings such as blown vinyl, wall paper etc. could be affected by the rising hot air and scorching and/or discoloration may result. Due consideration should be made to this when installing or decorating.
1.4 SHELF POSITION
The fire may be fitted below a combustible shelf providing there is a minimum dis­tance of 200mm above the top of the fire and the shelf does not project more than 150mm. If the shelf overhangs more than 150mm the distance between the fire and the shelf must be increased by 15mm for every 25mm of additional overhang over 150mm.
1.5 FLUE / CHIMNEY INSPECTION
Before commencing installation, a flue or chimney should be inspected to ensure that all the following conditions are satisfied.
1. Check that the chimney / flue only serves one fire place and is clear of any
obstruction. Any dampers or register plates must be removed or locked in the open position.
2. Brick/stone built chimneys or any chimney or flue which has been used for
an appliance burning fuel other than gas must be thoroughly swept. The base of the chimney / flue must also be thoroughly cleared of debris etc.
3. Any under-floor air supply to the fire place must be completely sealed off.
4. Ensure that the inside of the chimney / flue is in good condition along it’s
length and check that there is no leakage of smoke through the structure of the chimney during and after the smoke pellet test. With pre-cast flues
it is especially important to check the inside of the flue for extruded cement / sealant protruding from the joints between the flue blocks. If present, these should be removed by rodding the flue before proceeding with the installation.
5. Using a smoke pellet, check that there is an up-draught in the chim
ney / flue and that the smoke can be seen issuing from the terminal / chimney pot outside.
5
Page 6
There must be no leakage of smoke through the structure of the chimney during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney / flue. Check the chimney pot / terminal and general condition of the
brickwork or masonry. If the chimney or flue is in poor condition or if there is no up-draught do not proceed with the installation. If there is a history of down-draught conditions with the chimney / flue, a tested and certificated flue terminal or cowl suitable for the relevant flue type should be considered.
6. A spillage test must always be carried out during commissioning of
the appliance.
1.6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE
The front opening of the fire place must be between 330 and 430 mm wide, and between 550 and 565mm high. If the opening exceeds these dimensions then a surround must be constructed from suitable non-combustible material to produce a correct size opening. Any surround must be suitably sealed to the fire place to prevent leakage. See below in fig.1
When installing into a brick built chimney, you must ensure that there is sufficient depth to accomodate any debris which may fall from the chimney. This depth must be sufficient to accomodate 12 litres of volumetric space.
Fire Opening
330mm Minimum 430mm Maximum
610mm Minimum
520mm Minimum
Fig. 1
550mm Minimum 565mm Maximum
Minimum Flat Sealing Area
6
Page 7
Table A - Installation Depth Requirements for a Flavel Caress Slimline SC being installed into a brick built chimney, requiring 12.0 litres of debris collection volume (fig. 2)
330 (minimum opening width) 183 340 178 350 173 360 170 370 167 380 163 390 158 400 155 410 151 420 146 430 (maximum opening width) 143
For example, if the appliance was to be fitted into a 400mm wide opening, the depth required would be 189mm. See fig. 2 below for explanatory diagram.
Fig. 2
7
Opening Width ( e.g. 400mm)
Depth Required
(e.g. 155mm)
Page 8
1.7 FITTING TO FIREPLACES WITH EXISTING CHAIRBRICKS AND CONVENTIONAL BRICKBUILT CHIMNEYS
This appliance is suitable for use in fireplaces fitted with an existing chairbrick without the need for removal of the chairbrick, providing the minimum depth of the fireplace exceeds 190mm. If the depth is less than 190mm then the spacer (optional) must be used to give a minimum clearance from the rear of the fire to the rear of the chairbrick of at least 90mm to allow sufficient space for the collec­tion of debris which may fall down the chimney. The fireplace must be checked to ensure that no part of the chairbrick is within 50mm of the flue outlet of the fire when installed.
1.8 FITTING TO PRE-CAST FLUE INSTALLATIONS
When installing this appliance into pre-cast flues, always ensure that the spigot restrictor baffle has been removed.
To install the fire box in to pre-cast flue starter blocks, there must be at least 120mm from the mounting face of the fire to the rear of the pre-cast flue starter block to allow sufficient space for debris collection. It is important to
consider this depth when choosing a fire surround as the thickness of the fire surround must be sufficient to give a total depth of at least 120 mm to the rear of the starter block, otherwise there will be insufficient depth. To increase this depth the fire surround may be packed away from the wall using suitable non-combustible board, providing the installation is correctly sealed. If in doubt about the suitability of the fire contact BFM Europe for advice before proceeding. It is important to ensure that the pre-cast flue is in good condition and is free from extruded mortar or sealant from between the flue blocks.
This appliance has been tested for use in a pre-cast flue block complying with BS EN 1858. In accordance with BS EN 1858, pre-cast flues built with directly plastered faces (front or rear) are not correctly installed as to ensure proper operation with any type of gas fire. In some instances of this flue construction, temperature cracking of surface plaster may occur through no fault of the appliance. An air gap or some form of insulation material should be installed to prevent normal flue temperatures from damaging wall surfaces.
1.9 FITTING TO PRE-FABRICATED TWIN WALL METAL FLUE BOXES
The appliance may be fitted to twin wall metal flue boxes conforming to the con­structional requirements of BS 715, (for example the Selkirk LFE 125 box). The box must have a minimum flue diameter of 125mm internal and minimum internal dimensions of 160mm deep by 580mm high by 350mm wide. There are no maxi­mum dimensional requirements for the box. The top face of the box must be insulated with a minimum thickness of 50mm of non-combustible mineral wool insulation or similar material. The flue box must stand on a non-combustible base of minimum thickness 12mm.
8
Page 9
1.10 HEARTHS
This appliance must only be installed on to a concrete or non-combustible hearth. The hearth material must be a minimum thickness of 13mm with the top surface at least 50mm above the floor. The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760mm and a minimum projection of 300mm forwards from the fire opening.
1.11 SPILLAGE MONITORING SYSTEM
This appliance is fitted with an atmosphere sensing spillage monitoring system in the form of an oxygen sensing pilot. This is designed to shut the fire off in the event of a partial or complete blockage of the flue causing a build up of combus­tion products in the room in which the fire is operated. The following are impor- tant warnings relating to this spillage monitoring system :-
1) The spillage monitoring system must not be adjusted by the installer.
2) The spillage monitoring system must not be put out of operation.
3) When the spillage monitoring system is exchanged only a complete original manufacturers part may be fitted. It is not possible to replace individual parts on the pilot system on this appliance, only a complete pilot assembly (including the thermocouple) may be fitted.
9
Page 10
SECTION 2
INSTALLATION OF FIRE
2.1 UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully from the front of the appliance. Check the contents as listed :-
Packing Check List
1 off Fire box / burner assembly 1 off Cast trim 1off Fret / Ashpan 1 off Boxed ceramic base, 2 piece ceramic front rail 11 synthetic coals 1 off each User instruction book and Installation book 1 off Flue restrictor baffle (for use in brick built chimneys and large diameter
e.g. 175mm flue applications).
Fixing Kit Check List
2 off Fixing cables 4 off Wallplugs 4 off Eyebolts 2 off Tensioner bolts & nuts 2 off Tensioner screws 4 off Cast trim brackets & screws
2.2 INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys 175mm (7 inch) diameter lined brick or stone flue, or insulated pre-fabricated metal flue box to B.S. 715.
When installing into 125mm (5 inch) diameter lined brick or stone flue, or insulated pre-fabricated metal flue box to B.S. 715 and pre-cast flues the restrictor baffle must not be fitted.
A spillage test must always be carried out to check satisfactory clearance of flue products, regardless of the type of flue the appliance is being fitted to.
10
Page 11
To remove the burner, proceed as follows:
a) Remove the trim, which is secured by two screws at the bottom L/H &
R/H sides of the trim. Remove the burner heat shield from the front of the fire box to allow access to the burner. See fig. 3 below.
Fig. 3
b) Ensure that the hearth is protected from damage and carefully lift the
fire box into the fire opening, then slide it back into position. Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps present.
c) Remove the burner. To allow burner removal, the control lever operat
ing cable must be removed. The control lever operating cable can be seen running across the base of the fire, below the burner. To release the cable, unscrew the cable securing screw located in the centre of the aluminium operating arm and pull the cable out from its fixing hole. Release the other end of the cable by pushing the cable forwards to the right, i.e. into the operating arm so as to release the tension. Pull the cable nipple out of the retaining hole and remove the cable through the slot in the operating arm. See fig. 4 overpage
11
Page 12
Fig. 4
d) Unscrew the burner assembly fixing screws at either side of the firebox,
and the two fixing screws at the base of the fire (See fig. 5 below). Carefully pull the base of the burner forwards from the fuel-bed support panel. The burner can now be removed from the appliance.
Fig. 5
12
Page 13
Continue for all models
Whilst the fire box is still in position, decide which side the gas supply is to enter the fire from. If concealed pipe work is required plan the pipe run to enter the fire box through one of the openings in the sides of the fire box below the fuelbed sup­port panel and connect to the isolating / inlet elbow. The gas connection to the appliance should be made to the isolating / inlet elbow using 8mm rigid tubing. There must be no soldered joints within the firebox. See fig. 6a & 6b below for suggested concealed pipe layouts.
Fig. 6a
Fig. 6b
Note : Before breaking into the gas supply a pressure drop test should be carried out to establish that the existing pipework is sound.
Carefully withdraw the fire box from the opening to enable the gas supply and fire fixing to be completed. There is a choice of methods of fixing the firebox which are provided to enable the installer to deal with any type of installation.
13
Firebox
Fireplace
Builders Opening
Gas Supply
Firebox
Approx. 40mm
Fireplace
Gas Supply
Approx. 40mm
Page 14
IMPORTANT : Sealing of the Gas Unused Gas Pipe Inlet Apertures
In line with current CORGI regulations, it is imperative that the gas supply inlet apertures that are not utilised during the installation are sealed with the foil tape as supplied. Failure to seal these inlet apertures could lead to flame
reversal, which in turn will damage the burner and control systems of the product. Fig. 7 below shows a correctly sealed installation.
Fig. 7
PLEASE NOTE :-
14
Seal off unused gas inlet
apertures and cable fixing holes
as shown
Only holes to be left are the specifically sized air relief holes as indicated by the labels positioned by them and the gas inlet aperture that is used
BFM EUROPE LTD. WILL NOT BE LIABLE FOR GUARANTEE CLAIMS THAT ARE AS A DIRECT RESULT OF THE UNUSED GAS INLET APERTURES NOT BEING CORRECTLY SEALED.
Page 15
The preferred method of fixing which is suitable for almost all situations is the cable fixing method which is described in the following section in detail.
To fit using the preferred cable method proceed as follows-
e) Mark out and drill 4 off No 14 (6mm) holes in the back face of the fire
opening in the positions shown below in fig. 8
Fig. 8
Fit the wallplugs provided and screw the fixing eyes securely into the rear of the fire opening. If the clearance at the rear of the fire is at the minimum specified for a precast flue application, it may be necessary to bend over the lower fixing eyes after screwing them fully in to the rear of a pre-cast starter block.
f) Uncoil the two fire fixing cables and thread one end of each of the
cables through one of the two holes on each side of the flue outlet shroud.
g) Position the fire carefully on the (protected) surface of the hearth and
reach into the fire opening. Thread each of the cables vertically downwards through the pair of fixing eyes on the same side of the fire. Thread the free end of the cables through the corresponding circular hole on each side of the lower rear of the fire. Carefully slide the fire box back into the fire opening and pull both cables tight.
h) Thread a tensioning screw over each of the cables and ensure that the
tensioning nut is screwed fully up against the hexagon shoulder of the tensioning screw (this provides maximum travel for the tensioning nut).
i) Fit a screwed nipple on to each of the cables and pull hand tight up
against the tensioning screw, then secure each nipple with a flat bladed screwdriver. See fig. 9 overpage.
20mm
500mm
Fireplace Opening
100mm
250mm
15
Page 16
Fig. 9
j) Evenly tighten the tensioning nuts to tension both cables and pull the
fire snugly against the wall. Do not overtighten, it is only necessary to pull the seal up against the sealing face of the wall, it does not need to be compressed. Check that there are no gaps behind the seal.
k) With the fire securely in place, if a concealed gas connection has been
made through either of the access holes in the sides of the fire, the holes should be closed around the pipe to prevent leakage of air through the gap around the pipe.
l) Refit the burner. Fit the four retaining screws and check that the burner
is correctly locked into position. On slide control models refit the control cable To do this, firstly locate the nipple on one end of the cable into recess in operating arm and then secure the front part of the operating arm back onto the rear of the operating arm with the retained screw.
This should not be overtightened. Move the control lever fully downwards and check that the left hand micro-switch operates the igniter and that the control valve spindle is fully depressed. Move the control lever upwards to the “off” position and check that the right hand (cut-off) micro-switch operates. Check that the control lever operates smoothly and safely.
16
Page 17
NOTE : The cable is factory set, and therefore should need no adjustment
m) Refit the front burner heat shield to the sides of the fire box (2 Screws)
n) Before making the final gas connection, thoroughly purge the gas
supply pipework to remove all foreign matter, otherwise serious damage may be caused to the gas control valve on the fire.
The other firebox fixing method is as follows :-
In installations where the cable method is not suitable (e.g. loose masonary in rear of fire opening) the firebox can be secured to the fire surround using four screws and wall plugs provided. Below (fig.10) is a diagram to indicate the hole centre positions available on the firebox to facilitate the screw fixing to the fireplace / surround.
Fig. 10
17
430mm
300mm
133mm
Firebox Mounting Flange
420mm
Page 18
2.3 GAS TIGHTNESS AND INLET PRESSURE
a) Remove the pressure test point screw from the inlet elbow pressure test
point and fit a manometer.
b) Turn on the main gas supply and carry out a gas tightness test.
c) Depress the control lever to the position marked pilot. Hold down the
control lever for a few seconds to purge the pipe work. The burner should light, continue to hold the control lever for a few seconds to latch the slide valve then lift to the full-on position.
d) Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.)
e) Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detector.
18
Page 19
3.1 ASSEMBLING THE CERAMICS AND FUEL BED
a) Place the fuel-bed base centrally on to the fuelbed support and pull
fully forwards to the burner. Make sure that the fuelbed base is
located centrally in the fire box. Ensure that the fuelbed base is not lodged on the burner. See fig. 11 below.
Fig. 11
b) Place the left hand front coal rail moulding onto the front ceramic rail
support as shown below in Fig. 12
Fig. 12
19
NOTE : The position of the fuel-bed components are critical to the performance of the product. Therefore please ensure that the fuel-bed components are positioned as described in the following section prior to requesting a service call due to soot build up, poor flame pattern etc.
Page 20
c) Place the right hand front coal rail moulding onto the front ceramic rail
support as shown below in Fig. 13
Fig. 13
d) Fit four large coals behind the ceramic front rails as shown below in
Fig. 14
Fig. 14
20
Page 21
e) Select three of the small coals and fit onto the ribs of the fuel-bed base.
See fig. 15 below
Fig. 15
f) Select the remaining four small coals and arrange along the rear of the
fuelbed, directly behind the third row of coals. See fig. 16 below.
Fig. 16
21
Page 22
g) Ensure the coals sizes are correctly positioned as shown in Fig 17
below. “L” denotes “large” coals and “S” denotes small coals. If any coals are missing, please contact your retailer. Do not proceed with
the installation.
Fig. 17
h) Ensure the flame paths are un-interrupted as shown below in Fig. 18. If
necessary, make minor adjustments to the coal positions to ensure
the flame paths indicated by the arrows are available.
Fig. 18
Warning : Use only the coals supplied with the fire. When replacing the
coals remove the old coals and discard them. Fit a complete set of coals of the correct type. Do not fit additional coals or any coals other than a genuine replacement set.
22
L
L
L
L
S
S S
S
S
S
S
Page 23
To ensure that the release of fibres from these R.C.F (Refractory Ceramic Fibre) articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within heavy duty polythene bags, clearly labelled as “RCF waste”. RCF waste is classed as a “stable”, non reactive hazardous waste and may be disposed of at a landfill licensed to accept such waste Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area, and always wash your hands before eating or drinking.
3.3 FITTING THE TRIM - CARESS MODELS ONLY
a) Fit the 4 off mounting brackets supplied with the fire in the loose items
pack to the rear face of the Cast-Iron Trim as shown below in Fig. 19
Fig. 19
23
4 off Mounting Brackets
Page 24
b) Fit the fascia to the firebox by hooking the mounting brackets into the
slots on the firebox as indicated in Fig. 20
Fig. 20
3.3 FITTING THE FRET
a) Remove the fret & ashpan cover from the packaging.
b) Place fret up to the front radiused section of the fuelbed, taking care
not to move coal positions.
c) Place ashpan cover under fret assembly and centralise.
24
Image shows bottom right hand slot, further slots are position on mounting flange at opposite side and top L/H / R/H mounting flanges
Page 25
3.4 LIGHTING THE APPLIANCE
a) Turn on the isolation valve. Depress the control lever fully downwards
to the position marked. Hold down the control lever for a few seconds to allow the gas to reach the pilot.
b) The fire will then begin its ignition sequence. If the pilot does not light,
continue to press the control lever until ignition occurs. The pilot flame can be seen by looking underneath the front ceramic rail, above the burner heat shield, at the front left hand side of the fuelbed. When the pilot has lit, continue to hold the control lever down for 5-10 seconds to allow the thermocouple to heat up, before releasing the lever apply one firm downwards push to ensure that the f.s.d. valve is fully latched, if the pilot goes out when the control lever is released, repeat the lighting sequence.
c) After lighting, move control lever up to the high position and the main
burner will light. It is recommended that for the most efficient performance the fire is allowed to warm up for a few minutes with control lever set to high.
d) The gas control can be moved from the High to Low position to give the
desired heat output.
e) To turn the fire off, FULLY raise the control lever to the OFF position.
WARNING : If the fire goes out for any reason or is turned off and it
is necessary to re-light the fire it is important to allow the fire to cool for 3 minutes before attempting to re-light it.
3.5 CHECKING FOR CLEARANCE OF COMBUSTION PRODUCTS
a) Close all doors and windows in the room.
b) Light the fire and allow to run for approximately 5 minutes on high
position.
c) After approximately 5 minutes hold a smoke match just inside and
below the centre of the lower front edge of the top of the fire. (It is recommended that a suitable smoke match holder is used when check ing for clearance of combustion products). All smoke generated should be drawn back into the flue. If slight spillage occurs or if in doubt, repeat the test after a further 5-10 minutes. If the test indicates that
spillage is occurring and the flue restrictor baffle has been fitted, it should be removed and the test repeated after the fire has cooled.
25
Page 26
d) If spillage persists, the flue is not functioning correctly and a fault exists.
If, after investigation the fault cannot be traced and rectified, the fire must be disconnected from the gas supply and expert advice obtained.
e) If there is an extractor fan fitted any where in the vicinity of the
appliance, or in adjacent rooms the spillage test should be repeated with the fan running on maximum and all interconnecting doors open.
f) After ensuring that the fire is safe to use it should be left on high
position to fully warm up. During this time a slight odour may be noticed, this is due to the “newness” of the fire and will soon disappear.
At this stage any minor adjustments to the coals should be made using suitable long handled tongs and taking care not to damage the coals.
Finally, hand the Installation and Maintenance Instructions and the Users Instructions over to the customer and explain the operation of the fire.
26
Page 27
SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a CORGI registered engineer. This is a condition of the Flavel guarantee schemes. The service should include visually checking the chimney and fire opening for accumulations of debris and a smoke test to check for a positive up-draught in the chimney. The condition of the coals should be checked and if necessary the whole set
should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of access. After any servicing work a gas tightness check must always be
carried out.
4.1 Removal of the burner assembly
4.1.1 Prepare the work area (lay down dust sheets etc,)
4.1.2 Lift the fender and ash pan cover out of the way and put them in a safe
location. Remove all of the loose coals and front ceramic rail. Remove the trim. Unscrew the two pozi-drive fixing screws which secure the burner heat shield and remove it from the fire.
4.1.3 Isolate the gas supply and remove the inlet pipe from the appliance inlet
elbow. To allow burner removal, the control lever operating cable must be removed. The control lever operating cable can be seen running across the base of the fire, below the burner. To release the cable, unscrew the cable securing screw located in the centre of the aluminium operating arm and pull the cable out from its fixing hole. Release the other end of the cable by pushing the cable towards the right i.e. into the operating arm so as to release the tension. Pull the cable nipple out of the retaining hole and remove the cable through the slot in the operating arm. Remove the two retaining screws at the base of the burner unit, and the screw each side of the burner unit. The base of the burner unit can now be pulled forward, allowing the burner to be removed from the fire box. Remove the burner assembly from the fire.
4.1.4 Refit the burner assembly to the firebox by carefully pushing the bottom
of the burner back into position. Secure using the two screws into the side frame of the firebox, and two screws into the base.
27
Page 28
4.1.5 It is now necessary to refit and correctly tension the operating cable. To
do this, first set the control lever to the horizontal (central position), this is the position which creates maximum tension in the operating cable. Refit the operating cable to the aluminium operating arm, firstly locating the nipple on one end of the cable into recess in operating arm and then feed the other end through hole in operating arm. Pull the operat ing cable until it is finger tight and secure with screw into operating arm (do not over-tighten). Move the control lever fully downwards and check that the left hand micro-switch operates the igniter and that the control valve spindle is fully depressed. Move the control lever upwards to the “off” position and check that the right hand (cut-off) micro-switch operates. Check that the control lever operates smoothly and safely.
4.2 Removal of the battery ignitor
4.2.1 Remove the burner assembly as above.
4.2.2 Disconnect the ignition lead and earth lead from the igniter. Unscrew the
Battery retaining cap and place battery to one side. Then unscrew igniter retaining ring and remove igniter from panel. Re-assemble in reverse order and carry out a gas tightness test.
4.3 Replacing the battery
4.3.1 Unscrew Battery retaining cap situated at the front right of the fire and
remove the battery
4.3.2 Replace in the reverse order using a 1.5V AA Alkaline Battery.
4.4 Removing the Oxy-Pilot Assembly
Note: Because this appliance is fitted with an atmosphere sensing ‘Oxy­Pilot’ it is not possible to replace the thermocouple separately, because the thermocouple position is factory set to a tight tolerance. Any replacement of parts on the pilot requires a complete new pilot assembly.
4.4.1 Remove the burner assembly as in section 4.1
4.4.2 Unscrew and remove the thermocouple retaining nut from the end of the
control tap, disconnect the ignition lead from the pilot electrode and the two inline leads from the microswitch.
4.4.3 Unscrew and remove the two pozi-drive screws which secure the pilot
assembly to the burner. Remove the pilot.
4.4.4 Re-assemble in reverse order and carry out a gas tightness test.
28
Page 29
4.5 Replacing the Control Cable
4.5.1 The control lever operating cable can be seen running across the base
of the fire, below the burner. To release the cable, unscrew the cable securing screw located in the centre of the aluminium operating arm and pull the cable out from its fixing hole. Release the other end of the cable by pushing the cable towards the right i.e. into the operating arm so as to release the tension. Pull the cable nipple out of the retaining hole and remove the cable through the slot in the operating arm. See fig. 21 below.
Fig. 21
4.5.2 Hold the hexagonal control lever cable locking bush with a spanner
and unscrew the locking screw using a 2mm allen key to release the cable from the control lever. The control cable can now be removed from the cable guide tubes.
4.5.3 To fit the replacement cable, thread the end of the new cable into the
long length of p.t.f.e. sleeve (as supplied) , taking care not to kink the sleeve. Now carefully feed the sleeve and cable into the left hand cable guide tube until the ends emerge above the control lever. Now thread the short length of p.t.f.e. sleeve over the end of the cable and thread the sleeve and cable into the top of the short cable guide tube.
4.5.4 When the end of the cable emerges from the short cable guide tube,
locate the nipple on the other end of the cable into the locating hole in the aluminium operating arm. Thread the free end of the cable into the cable retaining hole on the operating arm, but at this stage do not tighten the securing screw.
29
Page 30
4.5.5 Fit the hexagonal control lever cable locking bush onto the control
lever and fit the control cable loosely into the bush in the gap between the two lengths of p.t.f.e. sleeve. Ensure that the cable is located in the retaining hole in the locking bush and tighten the screw sufficiently to retain the cable but still allowing it to slide for adjustment.
4.5.6 It is now necessary to correctly tension the operating cable. To do this,
first set the control lever to the horizontal (central position), this is the position which creates maximum tension in the operating cable.
Pull the free end of the operating cable through the operating arm until it is finger tight and secure with screw into operating arm (do not over tighten).
4.5.7 Slide the operating arm fully to the right hand position and hold in
position, slide the control lever relative to the cable until the cable retaining screw lines up with the hole in the spacer frame. This sets the control lever in the correct position. Hold the hexagonal locking bush with a spanner and tighten the retaining screw using the 2mm allen key. Move the control lever fully downwards and check that the left hand micro-switch operates the igniter and that the control valve spindle is fully depressed. Move the control lever upwards to the “off” position and check that the right hand (cut-off) micro-switch operates. Check that the control lever operates smoothly and safely.
PARTS SHORTLIST
Replacement of any other parts must be carried out by a competent person such as a CORGI registered gas installer. The part numbers of the user replaceable parts are as follows, these are available from specialist spares stockists whose details can be found on our web site, www.bfm-europe.com, in the ‘stockist’ section.
Fuelbed base B-96400 Fuelbed front rails (pair) B-96410 Replacement coal set B-96420 Complete ceramic set (base, front rails and coals) B-96430 ODS Pilot Assy. (NG) B-19660 ODS Pilot Assy. (LPG) B-19670 Ignition Wire B-34690 L/H fibre board 20-20050 R/H fibre board 20-20060 Rear fibre board 20-16660
30
Page 31
Page 32
Due to our policy of continual improvement and development the exact accuracy of illustrations and descriptions contained in this book cannot be guaranteed
Part No. B-118880
Issue 2
BFM Europe Ltd.
Trentham Lakes
Stoke-on-Trent
Staffordshire
ST4 4TJ
www.bfm-europe.com
Telephone - General Enquiries : (01782) 339000 Telephone - Service : (0844) 7700169
Loading...