![](/html/72/727b/727bd4b6eebe62221abb98826023a95dd8b2f7fccbddbb2e0847002d6ddb3bf5/bg1.png)
®
PrecisionCell GT
FOREMOST IN AIR FILTRATION
General
The PrecisionCell GT features extra heavy-duty
construction to meet the rigorous demands of gas
turbine rotary machinery air filtration applications.
They may also be utilized where extreme velocity or
turbulence have rendered other products to be ineffective. PrecisionCell GT filters are available in
ASHRAE efficiencies of 60-65% and 90-95% in
either single or double header versions.
Features
The PrecisionCell GT offers a high dust holding
capacity for increased service life, eliminating costly downtime and maintenance associated with filter
change out. The media is manufactured of a wetlaid, moisture resistant, dual layer micro-fine fiberglass with high tensile strength and long service
life. The heavy gauge hemmed-edge corrugated
aluminum separators offer increased pack rigidity
with optimal pleat spacing.
Gas Turbine Rigid Filters
Bulletin PB1004-1106
The heavy duty corrosion-resistant steel frame and
expanded metal faceguards on both the air entering
and air leaving sides protect the media pack.
Retainer straps and faceguards on both sides prevent filter collapse and maintain rigidity in elevated
resistance situations and blow back from turbine
surges.
Physical Data
Frame: Heavy duty corrosion-resistant steel
Media: Dual layer wet-laid micro-fine fiberglass,
sealed with class 1 urethane
Separators: Hemmed-edge corrugated aluminum
Headers: 13/16” wide corrosion resistant steel
Faceguards: Galvanized steel expanded
Gridstraps: Aluminized steel ”T” strap downstream
and horizontal strap upstream
Important Features
• Dual layer media for increased service life
• Faceguards and grid straps
• Media pack stabilizer
Flanders PrecisionA ire - Foremost in Air Filtration
Toll Free: 1-800-637-2803
![](/html/72/727b/727bd4b6eebe62221abb98826023a95dd8b2f7fccbddbb2e0847002d6ddb3bf5/bg2.png)
Nominal Nominal 250 fpm 375 fpm 500 fpm 625 fpm Media Weight
Depth Efficiency Size Area Each
(inch) HxWxD cfm pd cfm pd cfm pd cfm pd (sq.ft.) (lbs.)
(inch)
12 65% .20 .35 .45 .57
24x24x12 1000 1500 2000 2500 140 26
24x12x12 500 750 1000 1250 69 14
24x24x12 1000 1500 2000 2500 140 27
12 95% .25 .45 .65 .78
24x12x12 500 750 100 1250 69 14
Notes:
1. PD represents clean pressure drop in inchw.g. The recommended final pressure drop is 1.5 inch w.g.
2. Operation down to zero velocity is satisfactory for all models.
3. Performance tolerances conform to section 7.4 of ARI Standard 850.
4. Performance values stated may be averages typical of the products listed. Contact factory for actual performance
test reports on specific products.
5. Perfmormance values shown in this publication may be averages or estimates intended to generally represent
product styles. Always contact factory for latest actual test data on specific Flanders Precisionaire models.
Guide Specifications
1.0 General
1.1 Medium and high efficiency gas turbine rigid filters shall be PrecisionCell GT extended media
separator type filters as manufactured by
Flanders.
1.2 Filter sizes, efficiencies and capacities shall be
as scheduled on the drawings.
2.4 Corrosion-resistant steel expanded metal faceguards shall be installed on the air entering and
leaving sides.
2.5 1/2” corrosion-resistant steel “T” straps shall be
installed on the air leaving side and horizontal
strap on air entering side.
2.6 Filters shall be UL 900 Class 1 listed.
2.0 Filter Construction
2.1 Filters shall be constructed by pleating a continuous sheet of moisture-resistant dual layer,
wet-laid micro-fine glass media into closely
spaced pleats with hemmed-edge corrugated
aluminum separators.
2.2 The filter pack shall be compression sealed into
a 24 ga. corrosion-resistant steel frame.
2.3 The enclosing frame shall be assembled in a
rigid manner and shall incorporate a single or
double header as required by job conditions.
Flanders PrecisionAire
Foremost in Air Filtration
Toll Free: 1-800-637-2803
3.0 Performance
3.1 Initial and final resistance shall not exceed the
scheduled values.
3.2 Media area must equal or exceed that of the
specified filter.
3.3 The average efficiency shall be as determined
by the ASHRAE Standard 52.1 and 52.2 test
methods.
3.4 The manufacturer shall guarantee performance
as stated in the literature within tolerances as
outlined in section 7.4 of ARI Standard 800.
REPRESENTED BY: