Flaming River FR1052 User Manual

Page 1
TM
Electro Wizard
Battery Disconnect Switch
Page 2
FR1051 Mounting Diagram
Positive disconnection, 12V
GROUNDED SOLENOID (power supply coil negative)
Page 3
tch must be
screws UNI 5931: 1984, and plain washers
coil causes serious damage to the internal
FR1051 Technical Specifications
Positive disconnection, 12V
GROUNDED SOLENOID (power supply coil negative)
CHARACTERISTICS FR1051
Nominal tension Max 12V Max. continuous current on main
250 A (23°C / 73.4°F)
contacts Max. short time current on main
2500 A x 3 sec.
contacts Recommended wire section >75mm² / 0.116 sq in Protection degree IP 65 Tightening torque M10 nuts 20 Nm / 14.75ft lb Tightening torque M5 nuts 1.6 Nm / 1.18 ft lb Operating temperature range -40°C/+85°C -40°F/+185°F Contacts Silver plated copper Contact terminals M10 tin-plated brass Nuts for contacts Brass Peak current coil rated input 4.4 A Max. retaining coil 3.2 A Holding coil rated input 0.4 A
· The battery isolator swi placed as close as possible to the batteries. To avoid corrosion to wires and terminals, mount in a protected location.
· It can be fixed to the frame according to the fitting diagram shown in the drawing, using M 8 TCEI (cylindrical head – encased hexagon)
FITTING INSTRUCTIONS: ELECTRICAL DIAGRAM
8,4x1.7 UNI 6592:1969.
· The inversion of the power supply to the
diode.
Page 4
FR1051
Positive disconnection, 12V
GROUNDED SOLENOID (power supply coil negative)
The Flaming River FR1051 Disconnect Switch is designed to discon­nect a vehicle electrical system using a toggle switch(Not Included). The disconnect switch should be located as close as possible to the battery. The toggle switch can be located in any convenient location for ease of operator use.
1. Positive battery cable is connected to terminal 30 (POS.BATT.)
2. Vehicle load is connected to terminal 30A (POS.TEL.)
3. From terminal 85 (NEG.BOB.), connect a wire to one side of the toggle switch. (Any style of “maintained” switch is acceptable, 10 amp or greater).
4. Connect the other side of the toggle switch to chassis ground.
When the operator closes the toggle switch, the solenoid in the disconnect switch is activated. The switch will remain closed (on) as long as terminal 85 is grounded.
• Always use proper wiring techniques.
• Wire size should be determined using industry standards based
upon load requirements and length of cable needed.
• Activation solenoid has a max draw of 4.4 amps, 0.4 amps con­tinuous.
• Main terminals are rated for 250 amps continuous, 2500 amps peak.
• We always recommend the use of Battery Terminal Covers FR1003TM.
Page 5
FR1051 Wiring Diagram
Positive disconnection, 12V
GROUNDED SOLENOID (power supply coil negative)
Page 6
FR1052 Mounting Diagram
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
Page 7
Page 8
FR1052 Technical Specifications
isolator switch must be
screws UNI 5931: 1984, and plain washers
coil causes serious damage to the internal
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
CHARACTERISTICS FR1052
Nominal tension Max 12V Max. continuous current on main
250 A (23°C / 73.4°F)
contacts Max. short time current on main
2500 A x 3 sec.
contacts Recommended wire section >75mm² / 0.116 sq in Protection degree IP 65 Tightening torque M10 nuts 20 Nm / 14.75ft lb Tightening torque M5 nuts 1.6 Nm / 1.18 ft lb Operating temperature range -40°C/+85°C -40°F/+185°F Contacts Silver plated copper Contact terminals M10 tin-plated brass Nuts for contacts Brass Peak current coil rated input 4.4 A Max. retaining coil 3.2 A Holding coil rated input 0.4 A
· The battery placed as close as possible to the batteries. To avoid corrosion to wires and terminals, mount in a protected location.
· It can be fixed to the frame according to the fitting diagram shown in the drawing, using M 8 TCEI (cylindrical head – encased hexagon)
FITTING INSTRUCTIONS: ELECTRICAL DIAGRAM
8,4x1.7 UNI 6592:1969.
· The inversion of the power supply to the
diode.
Page 9
FR1052
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
The versatility of Flaming River’s FR1052 Disconnect Switch allows for multiple installation options based upon user need and vehicle applica­tion.
Options: A Include positive or negative electrical disconnection B Positive or negative switching. C Continuous operator controlled remote “on”, and Passive disconnect
via vehicle ignition off.
E The addition of the FR1053 Time Delay Relay makes the switch suit-
able for vehicles requiring a Selective Catalytic Reduction cleaning cycle or other custom features.
The disconnect switch should be located as close as possible to the battery.
Common Installations:
Operator controlled ON-OFF (+/- disconnect and switching)
1. Positive or negative battery cable is connected to terminal 30-31.
2. Vehicle load (+/-) is connected to terminal 30A-31A
3. User determines +/- switching. Term. 85 switched for negative, Term. 86 switched for positive. Un-switched side: 85 chassis ground, 86 positive. (Any style of “maintained” switch is acceptable, 10 amp or greater)
Page 10
FR1052
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
Passive Disconnect (Ignition OFF Battery Disconnection)
This installation uses a momentary switch (Not Included) to energize the vehicles electrical system, then uses the ignition system to main­tain the disconnect switch in the closed (on) position. When the igni­tion is turned off, the disconnect switch automatically opens (off) and the electrical system is disconnected.
1. Positive battery cable is connected to terminal 30-31
2. Vehicle load is connected to terminal 30A-31A
3. Terminal 85 (NEG.BOB.) is connected to chassis ground.
4. Terminal 86 (POS.BOB.) is connected to one side of momentary switch and is connected to an “ignition on” circuit (i.e. Switch “IGN/ RUN” terminal)
5. Other side of momentary switch is connected to constant positive. (Any style of momentary switch is acceptable, 10 amp or greater).
• Always use proper wiring techniques.
• Wire size should be determined using industry standards based
upon load requirements and length of cable needed.
• Activation solenoid has a max draw of 4.4 amps, 0.4 amps continu­ous.
• Main terminals are rated for 250 amps continuous, 2500 amps peak.
• We always recommend the use of Battery Terminal Covers FR1003TM.
Page 11
FR1052 Wiring Diagram
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
Page 12
FR1052 Wiring Diagram
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
Page 13
FR1052 Wiring Diagram
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
Page 14
FR1052 Wiring Diagram
Positive disconnection 12V
INSULATED SOLENOID (power supply coil from battery)
Page 15
WARRANTY DISCLAIMER: Flaming River’s Limited Warranty Flaming River warrants its products to be free from defects in ma­terial and workmanship for a period of one (1) year after the date of purchase, except that: All steering columns are warranted for a period of three (3) years from the date of purchase. The Big Switch (part number FR1005) is warranted for a period of three (3) years from the date of purchase, provided that it is not mounted with a steel bracket and provided further that it is adequately protected from environmental conditions. All electrical products other than the Big Switch are warranted for a period of ninety (90) days from the date of purchase. Flaming River’s warranty liability is limited to the replacement of defective products. Flaming River is not liable for any labor costs associated with any warranty claim, or for any incidental or consequential damages. Improper installation, abuse, racing, and/ or modification of the products voids this warranty. No warranty of merchantability or fitness for a particular purpose is made by Flaming River with respect to any of its products.
Warnings and Recommendations It is the customer’s responsibility to determine the suitability of a giv­en Flaming River product for the customer’s uses. Likewise, it is the customer’s responsibility to install a Flaming River product. Contact the vehicle manufacturer whenever installing a switch to confirm the appropriateness of using such a switch and the recommended place­ment of the switch on the vehicle. Use qualified chassis specialists for the installation of all steering related components. Be aware that the installation of certain Flaming River products may adversely im­pact a manufacturer’s warranty with respect to certain vehicles and other manufactured goods. Flaming River will repair or replace any product found to be defective in material or workmanship. Improper installation, abuse, racing and/or modification VOID WARRANTY. Flaming River is not responsible for any labor costs associated with any warranty.