This product is only suitable for well insulated spaces or occasional use
Installation & Precautions
Carefully remove the fire from the packing, checking that neither the heater nor the power cable has been damaged during transport. Do not
operate the fire if either is damaged. Please bear in mind the weight of the fire before removal from the packaging and installation. Consider if
help is required. Any alteration to the power cable should only be done by a qualified electrician and to the Flamerite Fires guidelines stated
below. Your fire is guaranteed for one year from the date of purchase. In the unlikely event of a breakdown you have access to our customer
services team, simply call 01543 251122 during office hours, 9am – 5pm or e-mail on info@flameritefires.com
that is packed at the side of the fire.
INSTALLATION
Where a chimney is not blocked off completely it will cause the heater to cut out during use. ONLY if installing into a chimney and you are not
sure that you have cut off the draw 100% we recommend covering the slots in the rear and at either side.
Automatic safety cut out: The heater is fitted with an automatic cut out to prevent any damage due to overheating. The element will continually
and automatically cut out if the airflow is obstructed. Never cover the air outlets. To reset, switch the fire off, disconnect from the mains supply,
remove the cause of the overheating, check the micro switches and allow to cool for a suitable period then switch the fire back on. Caution: In
order to avoid a hazard due to inadvertent resetting of the thermal cut out, the appliance must not be supplied through an external switching
device, such as a timer, or connected to circuit regularly switched on and off by a utility.
Electrical connections: Your appliance comes fitted with a plug that incorporates a 13A fuse. The replacement fuses must be 13A and ASTA
approved. If the fuse cover is lost the plug must not be used until a replacement cover, of the same colour, is obtained from an electrical retailer.
The appliance is fitted with a moulded plug if it is necessary cut off the plug, for any reason, it must be discarded immediately with the fuse
removed. Under no circumstances should any attempt be made to reuse the plug, do not insert into any 13A socket as this could cause a hazard. If
the mains cable is damaged it must be replaced by the manufacturer or an authorised technical service centre.
WARNING THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following code.
The accessories are found in a box
As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings in your plug proceed as follows: -
• The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E, or
coloured green or coloured green and yellow, or marked with the earth symbol
• The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N, or coloured
black.
• The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L, or coloured
red.
Insert the plug tightly into its IEC connector underneath the fire if not already done so. If the removal of the plug is absolutely necessary for
installation, cut off in an area within 100mm only of the plug itself. Any further will affect your warranty.
Page 1 of 3
![](/html/4c/4c85/4c85cd21d141d228e49d5341a4bd13542557212670d04da8f51c65a963b5fb5b/bg2.png)
The Fire Front: is held on by four keyhole slot brackets, the corresponding screws are attached to the case. Lift the front to remove or replace it
back onto the fire. Fig.1
Fig.1
Using in a Fireplace Suite:
Place into the suite from the front. Secure using the 4 x 12mm screws provided, one at each counter sunk hole in the flange corners.
Using as a Hole in the Wall:
The inset dimensions for Hole in the Wall: depth 16cm, height 50cm and width 132cm. To prevent the fire from being pulled over it must
be secured into place. The height at which you may wish to fix the fire to the wall is up to you, though we recommend anywhere from 4050cm from the floor to the bottom of the fire. Four counter sunk holes will be visible at each corner, two on each side of the outer return.
Place the fire into the hole, mark off where the fixing holes are to be drilled. Remove fire and drill the holes. When this is done push the
rawl plugs into the drilled holes, lift and secure the fire into place. The front may be reapplied by lining up the keyhole slot brackets with
their corresponding screws on the fire and pushing it down. The screws may need to be adjusted to remove any slack and allow for a tight
fit Fig.1.
Fuel Effects: Once the fire has been installed in the correct position, unpack the fuel effect from the accessory box and arrange exactly as
the instruction inside that box. Be mindful to tilt the logs toward the back of the fire so not to foul the glass.
Fitting the Glass: Whist holding at the bottom of the glass, place the top edge through the fire opening up both sides of the interior making sure
you start after the dampers and lift over the micro switch arm at the top. IMPORTANT Fig.2: The glass must be placed on top of the metal arm
and NOT under! Allow the bottom edge of the glass to sit into the channel in front of the fuel bed. To remove the glass, in the open fully tilted
position hold from the very top, pull out of the channel and carefully remove through the opening, bottom edge first.
Fig.2
Page 2 of 3