Carefully remove the fire from the packing checking neither the heater nor the power
Installation, Precautions, Servicing,
Cisco-Tyrus-Regan-Hudson-Mariner-Sonata
& 22 & 22 & 22
This product is only suitable for well insulated spaces or occasional use
& User Instructions
IMPORTANT
cable has been damaged during transport. Do not operate the fire if damaged. Please
bear in mind the weight of the fire before removal from the packaging and installation.
Consider if help is required. Always read this manual first before attempting to install
or use and keep in a safe place. Any alteration to the power cable should only be done
by a qualified electrician.
Your fire is guaranteed for one year from the date of purchase. In the unlikely event of
a breakdown you have access to our customer services team, simply call 01543 251122
during office hours, 9am – 5pm or e-mail on info@flameritefires.com The accessories
are found in a box that is packed at the side of the fire.
This product is only suitable for well insulated spaces or occasional use
1 | Page
Important Safety Information and Warnings
Where a chimney is not blocked off completely, any draw will cause the heater to cut
• For indoor use only.
• Do not use the fire in the vicinity of a bath, shower or swimming pool.
• Never use the fire to dry laundry.
• Never install the fire directly underneath a fixed main socket.
• Never cover the appliance.
• The use of an extension lead is not recommended.
• This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by children without supervision.
• Children of less than 3 years should be kept away unless continuously supervised
• Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it
has been placed or installed in its intended normal operating position and they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved.
• Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or
perform user maintenance.
• Some parts of this product can become very hot and cause burns. Particular attention must be given
where children and vulnerable people are present
• Caution should be applied to ensure that children do not play with the fuel effects.
• Ensure remote battery is disposed of safely. Do not dispose of in fire, do not swallow and keep away
from children.
• As with any electrical appliance whilst the instructions aim to cover as many eventualities as possible,
caution and common sense should be applied when operating your appliance, particularly in the
vicinity of small children.
•CAUTION: The heater is fitted with an automatic cut out to prevent any damage due to overheating.
The element will continually and automatically cut out if the airflow is obstructed. Never cover the air
outlets. To reset, switch the fire off, disconnect from the mains supply, remove the cause of the
overheating, where fitted check the OmniGlide micro switches. Allow to cool for a suitable period
then switch the fire back on.
•CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut out, the
appliance must not be supplied through an external switching device, such as a timer, or connected to
circuit regularly switched on and off by a utility.
out during use. Care should also be taken when fitting into a cavity wall in case of
damp or draft with external air vents fully sealed
2 | Page
Green and yellow:
EARTH
Blue:
NEUTRAL
Red:
LIVE
RECYCLING
for more details.
Electrical Connections
Insert the plug tightly into its IEC connector underneath the fire if not already done
Please recycle responsibly. Take your item to your local recycling
centre. You can easily locate your nearest centre on
the www.recyclenow.com website or check with your retailer for
details on either a collection service or a store take-back scheme (some
may apply charges). Councils may offer a household recycling
collection service for small electrical items; contact your local authority
Electrical connections. Your appliance comes fitted with a plug that incorporates a 13A fuse. The replacement
fuses must be 13A and ASTA approved. If the fuse cover is lost the plug must not be used until a replacement
cover, of the same colour, is obtained from an electrical retailer. The appliance is fitted with a moulded plug if
it is necessary cut off the plug, for any reason, it must be discarded immediately with the fuse removed.
Under no circumstances should any attempt be made to reuse the plug, do not insert into any 13A socket as
this could cause a hazard. If the mains cable is damaged it must be replaced by the manufacturer or an
authorised technical service centre.
WARNING THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following code.
As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings in
your plug proceed as follows: -
• The wire which is coloured green and yellow must be connected to the terminal in the plug
which is marked with the letter E, or coloured green or coloured green and yellow, or marked
with the earth symbol
• The wire which is coloured blue must be connected to the terminal in the plug which is marked
with the letter N, or coloured black.
• The wire which is coloured brown must be connected to the terminal in the plug which is marked
with the letter L, or coloured red.
so. If the removal of the plug is absolutely necessary for installation, cut off in an
area within 100mm only of the plug itself. Any further will affect your warranty.
3 | Page
Model
H W D
Hudson Mariner
570mm
420mm
75mm
Sonata
570mm
420mm
145mm
Installation Instructions
IMPORTANT
The standard height & width to inset your fire.
Regan Tyrus 570mm 420mm 40mm
Cisco 570mm 420mm 50mm
22 Regan Tyrus Cisco 570mm 420mm 40mm
1. Your fire has been designed for use as part of a fireplace mantel and surround suite. Be careful to
protect the hearth and surrounding areas of the fireplace when fitting, inset is from the front.
•SEALING: Your fire is classed as a portable space heater, do not use silicone or adhesives to seal
into place.
•AIRFLOW: Where a chimney is not blocked off completely, any draw will cause the heater to cut
out during use. Care should also be taken when fitting into a cavity wall for the same reason.
Any disregard for either of the above will very likely cause issue and abnormal running of the fire.
Warranty will be affected
Please now test the fire and follow the rest of the instructions
2. Once the fire has been installed in the correct position and test run, you may fit the frame & fret
and apply the fuel effect:
• Hudson, Tyrus & Regan: simply place the fret in front of the fire.
• Cisco: place the frame onto the fire and over the fret, clamping the rear most sides of the fret
tightly in-between the frame and the case.
•Mariner: add the flexible black light reducer behind the fret and place the frame and fret
combination onto the fire and clip into place.
•Sonata: Place the frame on the fire.
Unpack the fuel effect from the accessory box and arrange in a random formation on top of the
orange fuel bed.
4 | Page
Regan Tyrus Cisco
2.0kW
1.0kW
Manual & Remote Fire Operation
Fire controls (Manual)
• The on/off switch is located at the top of the opening on the right side; this is marked with I/O
and will need to be switched to I to illuminate the flame effect.
• The flame effect must be illuminated for the heater to work. For heating the controls are located
next to the on/off switch. For LOW heat push in the switch marked with a single bar I. For HIGH
heat push in the switch marked with the double bars II. Both switches must be depressed for
HIGH heat.
Fire controls (Remote)
• The on/off switch is located at the top of the opening on the right side; this is marked with I/O
and will need to be switched to I to illuminate the flame effect via the remote control.
• To turn the fire on, simply press and release the button on the remote keypad.
• To set the light to your desired brightness, press then release the button marked DIMMER or
. You will notice the flame effect brightness will continuously phase slowly from high to low.
At the desired point press then release the DIMMER or button to stop the phasing.
• For heating the fire must be switched on. To give HIGH heat, press then release the button
marked O/I. To turn the heater off, press then release again the button marked O/I.
Thermostat information
The thermostat should be turned to maximum. Once the required room temperature is achieved turn
the thermostat towards minimum until you hear a click. The thermostat will then regulate the room
temperature automatically. There can be up to 2 or 3 degrees drop or rise in temperature for the
thermostat to activate or deactivate. The temperature is taken from around the fire unlike a wall
thermostat that is usually positioned around the middle of a room, so please allow for inaccuracies.
Situations such as room size or position of fireplace i.e. near a working radiator might cause the
thermostat not to work efficiently.
Heat output HIGH LOW
Hudson Mariner 2.0kW 1.0kW
22 Regan Tyrus Cisco 2.0kW 1.0kW
Sonata 1.5kW .75kW
5 | Page
Maintenance
Trouble Shooting
WARNING: Before any maintenance/cleaning is undertaken, always disconnect the fire from the mains
power supply.
Replacing Lamps
Dimmable 240V 6W 3000k E14 LED lamps
Allow a suitable time for the lamps to cool then remove the glass & fuel effect (see Installation). Remove the
two screws from either side of the fuel bed and lift out of place. Remove and replace the lamps, fuel bed, fuel
effect and glass. Please note that replacement Lamps are only covered from purchase by a 2-year warranty.
Replacements are available from Flamerite Fires Ltd
Cleaning
The fire can be cleaned with a soft cloth and nonabrasive glass cleaner.
• No power to the fire: Check the wall socket, plug, fuse and lamps.
• Heat turns off quickly after turn on: Set thermostat to a higher temperature
• No illumination: Make sure fire is turned on. Check heater is working, if so check lamps.
• Heater blowing cold air: The safety cut out may have operated. Check for obstruction around the
heater. If continually a problem and fitted into a cavity wall or chimney breast check with installer the
inset opening has been 100% fully sealed from drawn air and draft.
• Noise when illuminated: Due to moving parts, the electric fire will make a noise.
• Noise from the heater when in use: The sound of rushing air is normal.
6 | Page
Staffs. WS13 7AU
Information Requirements
Information requirement for electric local space heaters
Model identifier(s) Cisco Tyrus Regan Mariner Hudson Sonata
Item Symbol Value Value Value Value Value Value Unit
Heat output
Nominal heat output
Minimum heat output (indicative) Manual
Maximum continuous heat output
Auxiliary electricity consumption
At nominal heat
At minimum heat
In standby Manual/Remote
Type of heat output/room temperature control
With mechanical thermostat room temperature control Yes