ADDITIONAL INFORMATIONS
WARRENTY: Beginning from the date of purchase a 2-year warranty is guaranteed for this device in case of any manufacturing errors or other functional deficien-
cies during runtime.The warranty does not apply in case of: damage caused by misuse mechanical damage arising from careless treatment (dropping, vigorous sha-
king, mishandling, etc) damage caused by liquids penetrating the device heat damage caused by overexposure to sunlight or heating electric damage caused by improper connecting (wrong power supply/ jacks/ MIDI connections/ voltage problems). If you have any complaints please contact your dealer or send an e-mail to:
sseerrvviiccee@@ffllaammee..ffoorrttsscchhrriitttt--mmuussiikk..ddee
TERMS OF PRODUCTION: conformity: CE, RoHS, UL DISPOSAL: The device is produced with RoHS-conformity (subject to the regu-
lations of the European Union) and is free of hazardous substances (like mercury, plumb, cadmium and hexavalent chrome). But electronical scrap is hazardous
waste. Please don’t add this to consumer waste. For a environment-friendly disposal of waste please contact your distributor or specialist dealer. ACKNOWLEDG-
MENT: For help and accistance a big thanks to: Thomas Wagner, Robert Junge, Anne-Kathrin Metzler, Lena Bünger, Schneiders Büro Berlin, Shawn
Cleary (Analogue haven) SUPPORT: Actually and additional informations, updates, downloads, and more:
http://flame.fortschritt-musik.de
RECORD/LOOP FUNCTIONS KEYBORD FUNCTIONS
RECORD: Record is on if REC switch in position top and play
ing the parameters if the REC switch is in position bottom.
LIST OF RECORDED PARAMETERS OF THE REC SWITCHES:
Rec switch 1 (switch 2 is in position KEYBOARD):
- Keynotes of the Keyboard and the moves of CV-2 ruler between
1..5 (= the octaves of keyboard notes)
Rec switch 1 (switch 2 is in position TRIGGER or LINK):
- Keynotes of scale
Please note: Both keynotes (from keyboard and scale) has the
same value!
Rec switch 2:
- the motions of the three knobs (Gate, Beat, CV-2)
LOOP (automtic copy of measures):
Recording steps with different lenght of the loop. To arrange
LOOPS faster, at position 1 or 2 the according steps of the not
played measures are recorded too.
That means: if BAR is at 1 all other measures are recorded with
the same played steps. So the sequence goes on looping, even if
you switch to BAR 4 (because all measures are the same). Because
of this, you can play
the measures only
separately when
BAR=4.
If BAR is=2, the
sceme is always 2measured and recorded are always 1 and
3, as well as 2 and 4.
KEYBOARD
If switch 2 in position KEYBOARD then the keyboard buttons can
be used like a mini keyboard (the note output is the CV output).
If a key is pressed then the KEYGATE output goes on (high level).
If a key is released then the KEYGATE output goes off (low level).
The octave of the note can be set with the CV-2 ruler between
position 1..5, displayed by the octaves LED’s.
Please note: The KEYGATE output is only available in mode KEYBOARD, not in the other modes TRIGGER and LINK.
*moog characteristic: 1Volt / octaves
LIST OF EXTERNAL CONTROL VOLTAGE FOR KEYNOTE*
LIST OF PRESET/USER SCALES (included the external control voltage)*
Keynote Voltage (KEYNOTE-In) Note (KEYNOTE-In)
C 1,000 Volt C1
#C 1,083 Volt #C1
D 1,166 Volt D1
#D 1,250 Volt #D1
E 1,333 Volt E1
F 1,416 Volt F1
#F 1,500 Volt #F1
G 1,583 Volt G1
#G 1,666 Volt #G1
A 1,750 Volt A1
#A 1,833 Volt #A1
B 1,916 Volt
B1
Bank/Patch Name Scale Voltage
(Scale-Input)
Notes
(Scale-Input)
1-1
Major Scale 1,2,3,4,5,6,7 1,000 Volt C1
1-2
Major Chord 1,3,5 1,083 Volt #C1
1-3
Major 6 Chord 1,3,5,6 1,166 Volt D1
1-4
Major 7 Chord 1,3,5,7 1,250 Volt #D1
1-5
Major 7b5 Chord 1,3,b5,7 1,333 Volt E1
1-6
Fourths 1,4,b7 1,416 Volt F1
1-7
Major Blues 1,b3,3,5,6,b7 1,500 Volt #F1
2-1
Minor harmonic 1,2,b3,4,5,b6,7 1,583 Volt G1
2-2
Minor clean 1,2,b3,4,5,b6,b7 1,666 Volt #G1
2-3
Minor chord 1,b3,5 1,750 Volt A1
2-4
Minor 6 chord 1,b3,5,6 1,833 Volt #A1
2-5
Minor 7 chord 1,b3,5,b7 1,916 Volt B1
2-6
Minor 7b5 chord 1,b3,b5,b7 2,000 Volt C2
2-7
Minor Blues 1,b3,4,#4,5,b7 2,083 Volt #C2
3-1
Dorian 1,2,b3,4,5,6,b7 2,166 Volt D2
3-2
Phrygian 1,b2,b3,4,5,b6,b7 2,250 Volt #D2
3-3
Lydian 1,2,3,#4,5,6,7 2,333 Volt E2
3-4
Diminished 1,2,b3,4,b5,b6,6,7 2,416 Volt F2
Bank/Patch Name Scale Voltage
(Scale-Input)
Notes
(Scale-Input)
3-5
Mixolydian 1,2,3,4,5,6,b7 2,500 Volt #F2
3-6
Wholetone 1,3,#4,#5,b7 2,583 Volt G2
3-7
Pentatonik 1,2,4,5,b7 2,666 Volt #G2
4-1
Spanish 1,b2,3,4,5,b6,b7 2,750 Volt A2
4-2
Algerian 1,2,b3,4,#4,5,b6,7 2,833 Volt #A2
4-3
Balinesian 1,b2,b3,5,b6 2,916 Volt B2
4-4
Byzantine 1,b2,3,4,5,b6,7 3,000 Volt C3
4-5
Hindu 1,2,3,4,5,b6,b7 3,083 Volt #C3
4-6
Nine tone 1,2,#2,3,#4,5,#5,6,7 3,166 Volt D3
4-7
Octatonic 1,b2,b3,3,b5,5,6,b7 3,250 Volt #D3
5-1
User Patch 1 initialized chromatic 3,333 Volt E3
5-2
User Patch 2 initialized chromatic 3,416 Volt F3
5-3
User Patch 3 initialized chromatic 3,500 Volt #F3
5-4
User Patch 4 initialized chromatic 3,583 Volt G3
5-5
User Patch 5 initialized chromatic 3,666 Volt #G3
5-6
User Patch 6 initialized chromatic 3,750 Volt A3
5-7
User Patch 7 initialized chromatic 3,833 Volt #A3