Manual FLAME DUALKEY MODULE Version 1.00
Contents
1. Short description ....................................................................... 3
2. Hardware / Connection .............................................................. 3
2.1 Module overview 3
2.2 Connection 4
3. Play Modi ................................................................................... 5
3.1 Mode ONE SHOT 5
3.2 Mode GATE 5
3.3 Mode LOOP 6
4. Parameter .................................................................................. 6
4.1 SHAPE (shape of envelope) 6
4.2 TIME (duration of envelope) 7
4.3 LEVEL 7
4.4 END-OUT 7
5. Appendix and technical informations........................................ 8
5.1 Technical details
5.2 Warrenty
5.3 Terms of production
5.4 Disposal
5.5 Support
5.6 Acknowledgment
2
![](/html/43/4375/4375d23a068e49ff5bed670b7709912bb537b8d93206df49366b6043c6622d16/bg3.png)
1. Short description
Dualkey is composed of two modulators with A(H)D, A(S)R and Loop modes. Length and shape
of rising / falling edge can be adjusted manually as well as influenced by CV signals. At most,
the module emits voltages of 0..+10v. Additionally the circuits generate a trigger signal after each
envelope cycle.
Furthermore, they produce gate voltages while active. Besides control inputs, each modulator
features a button for manually starting the corresponding envelope.
There are two channels with almost identical functions.
2. Hardware / Connection
2.1. Module overview
Channel 1
CV inputs TIME and SHAPE
Channels CV output
Input KEY
Outputs END-trigger and KEY
Pot LEVEL CV output
Switch TIME range
Pot TIME
Channel 2
Switch MODE
Pot SHAPE
Channel KEYs
(illuminated push buttons)