FläktGroup CPDB, CPDA, CPDH, CPDK, CPDJ Technical Manual

...
Page 1
TECHNICAL MANUAL
COOKER HOOD CPD
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 1 2018-04-26 16:06
Page 2
Cooker hood CPD - Technical manual
2
Specifications are subject to alteration without notice
CONTENT
WARNING! THE DEVICE CAN BE USED BY CHILDREN FROM 8 YEARS UPWARDS AND PEOPLE (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPA BILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE RECEIVED GUIDANCE OR INFORMATION ON HOW TO USE THE DEVICE SAFELY AND UNDERSTAND THE RISKS THAT CAN OCCUR. CHILDREN SHOULD NOT PLAY WITH THE APPLIANCE. CLEANING AND MAINTENANCE IS NOT CARRIED OUT BY CHILDREN WITHOUT SUPERVISION.
MAINTENANCE (FOR THE USER)
Cleaning .......................................................................................................... 3
Replacing of the low energy lamp ....................................................... 3
General ............................................................................................................ 3
Operating of CPDA and CPDJ ...................................................................4
Operating of CPDB, CPDC, CPDG, CPDH, CPDK .............................. 5
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
Installation height ...................................................................................... 6
Main supply .................................................................................................. 6
General ............................................................................................................ 6
CPDA .................................................................................................................7
CPDB ................................................................................................................. 8
CPDC ............................................................................................................... 8
CPDG ............................................................................................................... 9
CPDH ............................................................................................................. 10
CPDK ............................................................................................................. 10
CPDJ ................................................................................................................ 11
ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDG ........................................................................................................................12
ADJUSTMENT, COMMISSIONING (FOR INSTALLERS AND SERVICE PERSONNEL)
CPD(A, B, C, G) - Basic ventilation .....................................................13
CPD(A, B, C, G) - Forced ventilation ..................................................14
CPD(H, K) - Basic ventilation ................................................................15
CPD(H, J, K,) - Forced ventilation ....................................................... 16
GENERAL
Spare parts CPD(A, B, C, G, H, J, K) .............................................................17
Declaration of conformity ................................................................................18
Disposal of product and packaging materials ...................................... 19
Cooker hoods CPDD and CPDL, see separate instruction.
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 2 2018-04-26 16:06
Page 3
Cooker hood CPD - Technical manual
3
Specifications are subject to alteration without notice
MAINTENANCE
CLEANING OF COOKER HOOD
Do not use abrasive sponge or cloth.
alt.
1
2
33
CLEANING OF GREASE FILTER
REPLACING OF THE LOW ENERGY LAMP
Check the grease filter every week.
Clean if needed.
Note! Do not use the cooker hood
without grease filter fitted.
GENERAL
There is a fire risk if cleaning is not carried out in accordance with the instructions.
Accessible parts may become hot when used with cooking appliances.
Do not flambé under the cooker hood.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified per
-
sons in order to avoid hazard.
11 W/E14
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 3 2018-04-26 16:06
Page 4
Cooker hood CPD - Technical manual
4
Specifications are subject to alteration without notice
MAINTENANCE
OPERATING OF CPDA AND CPDJ
Handle for boosting Lighting
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 4 2018-04-26 16:06
Page 5
Cooker hood CPD - Technical manual
5
Specifications are subject to alteration without notice
NORMAL
MIN
MAX
MIN
1
2
MIN
1
2
MIN
1
2
MAINTENANCE
OPERATING OF CPDB, CPDC, CPDG, CPDH AND CPDK
Handle for boosting Lighting Handle for fan speed
MIN
1
2
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 5 2018-04-26 16:06
Page 6
Cooker hood CPD - Technical manual
6
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
INSTALLATION HEIGHT MAIN SUPPLY
min 400 mm
All cooker hoods has to be connected directly or indirectly via the heat recovery unit/exhaust fan to earth.
If the supply cord is damaged, it must be replaced by the manu
­facturer, its service agent or similarly qualified persons in order to avoid hazard.
The distance between the stove and the lower edge of the cooker hood has to be at least 400 mm, recommended distance 500 mm.
When the cooker hood is located above a gas appliance, this dis
­tance shall be at least 650 mm. If the instructions for installation of the gas hob specify a greater distance, this has to be taken into account.
GENERAL
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
Regulations concerning the discharge of air have to be fulfilled.
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 6 2018-04-26 16:06
Page 7
Cooker hood CPD - Technical manual
7
Specifications are subject to alteration without notice
min 500 mm
2
3
1
max
300 mm
1
2
3
5
4
max
300 mm
12mm
Ø 50
160
100
a
min 500 mm
a =700 a =600
a =500
200 100 100
415 365 365
255 205 205
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDA
Intended for multiple-unit dwellings with a central extract air fan or a heat recovery unit. Suitable for both new production and replacement of older cooker hoods.
INSTALLATION BENEATH KITCHEN CABINETS
a
a
b
b
INSTALLATION BETWEEN KITCHEN CABINETS
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 7 2018-04-26 16:06
Page 8
Cooker hood CPD - Technical manual
8
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDB
Replacement hood for older exhaust air fan JBDD-aa with capacitor box, manufactured before 2007.
JBDD-aa
(earlier version)
CPCB
JBDD-aa
(earlier version)
a
a
b
b
CPDC
Replacement hood for older heat recovery unit RDKG without bypass (fits RDKG-a-1-c-d-1).
1
5
6
2
3
4
3.1 3.2
Remove the old cooker hood.
It is important to seal the grommet by putting
back the small piece of sealing material.
Remove the old cooker hood.
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 8 2018-04-26 16:06
Page 9
Cooker hood CPD - Technical manual
9
Specifications are subject to alteration without notice
CPDG
With transformer, fits for example the new JBDD and JBFG. (Fits JBDD-aa-1-2 but also as replacement cooker hood for controlling older exhaust air fans and units, for example JBDB, JBDC and RDAA.)
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
3
2
1
RDKS
4
5
4.1
4.2
2
3
1
JBDD
1
2
1 = Orange - Supply voltage
to fan 2 = Blue - Neutral 3 = Black - Phase 4 = Yellow/Green - Ground
3
2
3
1
min 500 mm
CONNECTION TO EXHAUST FAN JBDD, GENERATION 2
INSTALLATION BETWEEN KITCHEN CABINETS
CONNECTION TO OTHER FANS
For electrical installation, see wiring examples on page 12.
INSTALLATION BENEATH KITCHEN CABINETS
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 9 2018-04-26 16:06
Page 10
Cooker hood CPD - Technical manual
10
Specifications are subject to alteration without notice
CPDH
Replacement hood for older heat recovery units RDKG with bypass. (Fits RDKG-a-2-c-d-1).
a
b
CPDK
For heat recovery unit RDKG. (Fits RDKG-a-b-c-d-2).
a
b
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
1
4
5
3
2
Remove the old cooker hood.
2
1
3
4
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 10 2018-04-26 16:06
Page 11
Cooker hood CPD - Technical manual
11
Specifications are subject to alteration without notice
INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL)
CPDJ
For heat recovery unit RDKR or RDKS.
a
b
3
2
1
RDKS
RDKS
4
5
4.1
4.2
7
6
It is important to seal the grommet by putting back the small piece of sealing material.
The picture illustrates a right hand unit.
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 11 2018-04-26 16:06
Page 12
Cooker hood CPD - Technical manual
12
Specifications are subject to alteration without notice
ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL)
Note! Electrical connections have to be made by authorized personnel.
EXHAUST FAN JBDB EXHAUST FAN JBDC
ROOF FAN JBFG HEAT RECOVERY UNIT RDAA
1)
Not for conversion kit JBDB-99-05-0
JBDB
1)
CPDG/CPTG
Supply 230V
JBDA-99-031 2µF, not included
N
L
Blue
Blue
White
Black
Black
Yellow/Green
Yellow/Green
Orange
JBFG
CPDG/CPTG
Supply 230V
N
L
Blue Blue
Brown
Black
Yellow/Green
Yellow/Green
Orange
JBDC
1)
CPDG/CPTG
N
L
1)
Also for conversion kit JBDB-99-05-0
Supply 230V
JBDA-99-031 2µF, not included
Brown
Blue
Black
Blue
Black
Yellow/Green
Yellow/Green
Orange
RDAA
CPDG/CPTG
Supply 230V
N
2 4 5 6 731
L
Orange
Black
Blue
Yellow/Green
CPDG
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 12 2018-04-26 16:06
Page 13
Cooker hood CPD - Technical manual
13
Specifications are subject to alteration without notice
ADJUSTMENT
b
c
a
Pa a =
7,5 10 12,5 15 20 25
250
200
100
50
40
30
5
6
7
8
9
10 12
15
20
30
Air flow q l/s
Measuring pressure
∆p
m
, Pa
30
30 + 1xC
30 + 4xC
30 + 2xC
CPDA, CPDB, CPDC AND CPDG – BASICVENTILATION
∆p
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 13 2018-04-26 16:06
Page 14
Cooker hood CPD - Technical manual
14
Specifications are subject to alteration without notice
CPDA, CPDB, CPDC AND CPDG – FORCED VENTILATION
When adjusting the forced air flow the fan speed must be increased up to the forced flow.
10
20
30
40
50
100
200
150
20 30 40 50 80
Air flow q, l/s
Measuring pressure ∆p
m
, Pa
b = 5
a = 25 10
10
10
13
25
1015 15
15
25 25
25
7 9
11
a b
10
14
25
a
b
a
∆p
ADJUSTMENT
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 14 2018-04-26 16:06
Page 15
Cooker hood CPD - Technical manual
15
Specifications are subject to alteration without notice
CPDH AND CPDK – BASIC VENTILATION
The basic air flow in the hood is adjusted by removing any number of plugs in the cover plate.
1
2
3
4
5
6
7
8
9
10
∆p
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
30
10
8
6
4
2
Air flow q, l/s
Measuring pressure ∆p
m
, Pa
2, 4, 6, 8 och 10 = number of open holes in the cover plate.
Connection of the measuring tube
ADJUSTMENT
When forcing the air stream must be mea sured at both measure­ment points (basic flow and forced flow).
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 15 2018-04-26 16:06
Page 16
Cooker hood CPD - Technical manual
16
Specifications are subject to alteration without notice
CPDH AND CPDK - FORCED VENTILATION
Damper blade without basic flow valve (sealed damper blade) When adjusting the forced air flow the fan speed must be increased up to the forced flow.
ADJUSTMENT
10
20
30
40
50
100
200
150
20 30 40 50 80
Air flow q, l/s
Measuring pressure
∆p
m
, Pa
b = 7
13
14
15
8 9 11
∆p
b
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 16 2018-04-26 16:06
Page 17
Cooker hood CPD - Technical manual
17
Specifications are subject to alteration without notice
CPDA, CPDB, CPDC, CPDG, CPDH, CPDJ AND CPDK
SPARE PARTS
Pos No. Designation Description
Intended for CPD...
A B C G H J K M
1 25 CPDA-99-01 Handle x x x x x x x x 2 10 CPDA-99-02 Lightning switch x x x x x x x x 3 1 CPDA-99-03 Front board 1-handle, 500 mm x 3 1 CPDA-99-04 Front board 1-handle, 600 mm x x 3 1 CPDA-99-05 Front board 1-handle, 700 mm x x 3 1 CPDC-99-02 Front board 2-handles, 500 mm x x 3 1 CPDC-99-03 Front board 2-handles, 600 mm x x x x x x 3 1 CPDC-99-04 Front board 2-handles, 700 mm x x x 4 10+10 CPDA-99-07 Black plastic corners, right and left x x x x x x x x 5 1 CPCA-99-15 Timer with shaft: 600 mm (R, L), 700 mm (R) x x x x x x x
5 1 CPDA-99-10
Timer with shaft: 500 mm (M), 600 mm (M), 700 mm (M, L)
x x x
5 1 CPDJ-99-01 Timer w. shaft: 600, 700 mm (w. contact function) x 6 10 CPCA-99-09 Lamp socket x x x x x x x 6 10 CPDA-99-12 Lamp socket, transverse light x x x x x x x x 7 1 CPCA-99-12 Throttling device, complete x x x x 7 1 CPDH-99-02 Throttling device, complete (without basic flow) x x x x 8 25 BHGA-99-48 Plastic plugs x x x x x x 9 10 CPDA-99-06 Lamp protecting glass x x x x x x x x
10 1 CPCA-99-13 Grease filter x x x x x x x x
11 5 CPDC-99-01 Switch x x x x x x 12 1 CPDG-99-01 Transformer x x 13 1 CPDH-99-01 Time relay x
14 10 CPDA-99-15 Damper eccentric, 10-pack x x x x x x x x 15 10 CPDA-99-13 Damper gasket, 10-pack x x x x x x x x
1
2
3
6
12
13
9
4
4
8
14
15
7
10
5
11
Pos 5. R = Rght, M = Middle, L = Left
Cut the power before start working with the unit. All work has to be carried out by qualified personnel in order to avoid hazard.
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 17 2018-04-26 16:06
Page 18
Cooker hood CPD - Technical manual
18
Specifications are subject to alteration without notice
DECLARATION OF CONFORMITY
ENCLOSURE
II A
FläktGroup Sweden AB
Postal Address Street Address Telep hone Telefax Reg. no: FläktGroup Sweden AB Fläktgatan 1 Nat 036 - 19 30 00 Nat 036 - 19 31 40 556239-2463 S-551 84 Jönköping Int +46 36 19 30 00 Int +46 36 19 31 40 Reg. office: Sweden Jönköping
8364GB_CPD Declaration of conformity(2A)201804
Declaration of Conformity
In accordance with: EU Directive for Machinery, 2006/42/EC EU EMC Directive, 2014/30/EU EU RoHS Directive, 2011/65/EU
Manufacturer FläktGroup Sweden AB
Fläktgatan 1 551 84 Jönköping
Herewith declares that:
Product Type: Cooker Hood Manufacturer: FläktGroup Sweden AB
Commercial name: CPD/A/B/C/D/G/H/J/K/L ( several versions / variants)
The machine is designed and manufactured in accordance with the following standards, in relevant parts.
EN ISO 12100 Safety of machinery – General principles for design- Risk assessment and risk reduction
EN 60204-1 Safety of machinery; electrical equipment of machines; general requirements
EN 60335-1 Household and similar electrical appliances - Safety - Part 1: General requirements
EN 60335-2-31 Household and similar electrical appliances - Safety - Part 2: Particular requirements
EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments EN 61000-6-3 Emission standard for residential, commercial and light-industrial environments. EN 50106:2008 Safety of household and similar electrical appliances - Particular rules for routine tests
referring to appliances under the scope of EN 60335-1 EN 62233:2008 Measurement methods for electromagnetic fields of household appliances and
similar
apparatus with regard to human exposure
EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with
respect to the restriction of hazardous sustances
A risk analysis has been made according to requirements of the Directive for Machinery.
Authorized To prepare technical documentation:
Ann-Sofie Andersson
Design- R&D
FläktGroup Sweden AB
Fläktgatan 1 551 84 Jönköping
The declaration applies only to the installation made according to FläktGroups instruct ions and assuming no changes made to the unit.
Jönköping 2018-04-24
Magnus Nilsson, Quality Manager, FläktGroup Sweden AB, Jönköping
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 18 2018-04-26 16:06
Page 19
Cooker hood CPD - Technical manual
19
Specifications are subject to alteration without notice
DISPOSAL OF PRODUCT AND PACKAGING MATERIALS
Recycling should be made in accord­ance with local regulations. When the product is scrapped the following parts/ components/materials shall be sorted. Depending on what product it is may not all parts/components/materials be rep
-
resented.
– Printed circuit boards, cables, batteries, motors, sensors etc.
– Filters, except made of pure metal (in cooker hoods).
– Packaging materials, such as cardboard, plastic and
styrofoam.
– The units casing may contain condense- or mineral wool
insulation sandwiched between the inner and outer shell.
– The remaining parts shall be sorted as metallic.
– Lamps and fluorescent lights.
See www.flaktwoods.com/ecodesign for recycling instructions.
FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd 19 2018-04-26 16:06
Page 20
FG_DC_8757GB_CPD_IN-MA-CM-SP_20180426_R1 © Copyright 2018 FläktGroup J8013821-2301
WWW.FLAKTGROUP.COM CPD
» Learn more on www.flaktgroup.com or contact one of our offices
FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions.