INSTALLATION INSTRUCTIONS
PROFESSIONAL COOKTOP MODELS
48” GAS COOKTOP WITH SEALED BURNERS**
48” NATURAL GAS MODEL
*TN047-7
**THIS MODEL IS NOT FIELD CONVERITBLE FOR LP/PROPANE GAS. IT MUST BE ORDERED
FROM THE
**THIS MODEL IS NOT FIELD CONVERITBLE FOR NATURAL GAS. IT MUST BE ORDERED FROM
THE
FACTORY SET FOR NATURAL OR LP/PROPANE.**
48” LP/PROPANE GAS MODEL
*PN047-7
FACTORY SET FOR NATURAL OR LP/PROPANE.**
I
F YOU HAVE QUESTIONS, CALL 800-251-7224, 8 AM TO 5 PM EASTERN TIME, OR VISIT OUR
WEBSITE
, WWW.FIVESTARRANGE.COM.
Installation Instructions
BEFORE YOU BEGIN CAUTION:
Read these instructions completely and
carefully.
• IMPORTANT - Save these instructions for local
inspector's use.
COOKTOPS SHOULD BE INSTALLED IN
CONJUNCTION WITH A SUITABLE
VENT HOOD. Due to the high heat capacity of this unit,
particular attention should be paid to the hood and duct
work installation to assure it meets local building codes.
OVERHEAD
• IMPORTANT - Observe all governing codes and
ordinances.
• Note to Installer - Be sure to leave these instructions
with the Consumer.
• Note to Consumer - Keep these instructions for future
reference.
• FiveStar recommends this product be installed by a
licensed professional.
• Product failure due to improper installation is not
covered under the Warranty.
In the Commonwealth of Massachusetts:
• This product must be installed by a licensed plumber
or gas fitter.
• When using ball type gas shut-off valves, they shall
be T handle type.
• A flexible gas connector, when used, must not
exceed 3 feet.
WARNING:
This appliance must be properly grounded.
Standard cooktop installations:
A 1200 CFM hood is recommended for 48" cooktops.
A 600 CFM hood is recommended for 36" cooktops.
Hoods should be 24" min. deep and at least the same width
as the cooktop.
Check local building codes for the proper method of gas
cooktop installation. Local codes vary. Installation, electrical
connections and grounding must comply with applicable
codes. In the absence of local codes, the gas cooktop should
be installed in accordance with the National Fuel Gas Code
ANSI 223.1, latest edition and National Electrical Code
ANSI/NFPA 70, latest edition
CAUTION:
disassembly will reduce the weight considerably. Due to
the weight and size of the cooktop and to reduce the risk of
personal injury or damage to the product and/or damage
to the floor, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
Cooktops weigh up to 170 pounds. Some
INSTALLATION INSTRUCTIONS
Please read these instructions
before attempting to install this
cooktop.
Inspection and Unpacking
Check the cooktop carton for visible
damage. If there is damage or even
creases in the carton, contact the
carrier, request an inspection and file
the appropriate freight claim. Do not
refuse shipment. Responsibility for
shipping damage is with the carrier
and the dealer or end user. Cut the
shipping straps, then carefully lift the
carton up from the cooktop. This will
help eliminate possible damage.
Remove, unwrap and temporarily lay
aside any parts that are not attached
to the cooktop. Make sure no parts are
left in the carton for accidental
disposal. Carefully inspect the 48” COOKTOP = 48 3/16”
cooktop for damage.