Fisher & Paykel DishDrawer DD60ST Series Installation Instructions Manual

Important!
SAVE THESE INSTRUCTIONS
The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our local website listed at the end of this document or contact your local Fisher & Paykel dealer.
SAFETY AND WARNINGS
1
DishDrawer®
NZ AU GB IE
DD60ST models
WARNING!
Electrical shock hazard
Before installing the DishDrawer®, remove the house fuse or open the circuit
breaker.
This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances. WARNING- Improper connection of the equipment­earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly earthed.
Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box.
Failure to follow this advice may result in electrical shock or death.
WARNING!
Cut hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
Important safety instructions!
Installation of this DishDrawer® requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the DishDrawer® installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the DishDrawer®. This DishDrawer® is manufactured for indoor use only. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.
The switched power outlet must be outside the DishDrawer® cavity, so that it is accessible after
installation.
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord. If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.
Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not
be reused. Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle,
boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.
(1,1) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
(1,1) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
23
PRODUCT DIMENSIONS CABINETRY DIMENSIONS
A
B
C
E
D
F
G
H
J
Prefinished Flat door & Integrated models for 480mm cavity
Integrated models for 456mm cavity
K
Product dimensions (mm)
Pre nished
Flat door
DD60ST
Integrated
456 mm cavity
2
DD60ST
Integrated
480 mm cavity
DD60ST
A
overall height1 of product (incl. drawer front height)
477
3
453 477
3
B
overall width of product
599 599 599
C
overall depth of product (excl. curvature/handle)
570 570
4
570
4
D
depth of drawer (open) (excl. curvature/handle)
538 538 538
E
height1 of chassis
453 453 453
F
depth of chassis (incl. trimseal)
552 552 552
G
depth of drawer front panel (excl. curvature/handle)
18 18 18
H
depth of curvature or handle
41 n/a n/a
I
height of drawer front
470 442 min 470 min
J
height of venting area at base of product
999
K
height of installation bracket slots (on top of chassis)
222
1
Chassis heights include bracket slots 2In this instance, you would skip step 6 3Includes cavity bracket 4Panel thickness - 18 mm
Note: for Pre nished Flat door models, the height from the top of handle to the top of door - 64 mm
I
Installation diagrams for illustration purposes only
Cabinetry dimensions (mm)
Pre nished
Flat door
DD60ST
Integrated
456 mm cavity
DD60ST
Integrated
480 mm cavity
DD60ST
A
inside height of cavity
480 456 480
B
inside width of cavity
600 600 600
C
inside depth of cavity (inside)
580 580 580
K
F
C
H
2.5 mm
2.5 mm
13 mm
Minimum clearances (mm)
A
A
B
C
Installation diagrams for illustration purposes only
Cavity height options for Integrated models:
To match existing kitchen cabinetry or the height of other appliances installed next to DishDrawer, you may choose to install DD60ST Integrated models into either a 456 mm or a 480 mm high cavity. Note: the minimum height of the custom drawer front panel will also be different for these two options.
(1,2) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
(1,2) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
PARTS SUPPLIED
If the Drain hose supplied is not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose by 3.6m. The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our local website listed at the end of this document.
4
5
CAVITY PREPARATION
These marks indicate formed bracket screw locations.
Preferred position. If adequate clearance, services hole can be higher. If hole is higher, ensure drain hose is routed straight into the waste connection.
Water Connection
Recommended COLD (Maximum 60°C). ¾ “ BSP (GB20) to suit flat washer.
Water Pressure Max Min
Water softener models 1 MPa (145 psi) 0.1 MPa (14.5 psi) Other models 1 MPa (145 psi) 0.03 MPa (4.3 psi)
Drains will need to be separated to satisfy kosher requirements. We suggest you confirm acceptability with your local rabbi in respect to kosher installations.
*
Clamp (1)
Wire clip (1)
Phillips 16 mm screws (7)
38 mm bottom fixing screws & metal washers (2)
Drain hose support (1)
Moisture protection tape (1)
(to prevent moisture damage)
Cavity bracket kit (1)
Drain hose joiner (1)
Rubber washer for inlet hose (1)
Side mounting bracket kit (A and B) (2)
OPTIONAL
Top mounting brackets (2)
OPTIONAL
Note: Services can be located either side of DishDrawer®.
Important!
Adjacent cabinetry must not extend above cavity base
220-240 VAC min. 4.5 A
min.
200 mm
10 mm
max.
450 mm
min. ø
60 mm
Moisture protection tape must be applied.
*
*
Water supply
(2,1) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
(2,1) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM