DATA SHEET
11 13/16''
B
CLEARANCE : COMBUSTIBLE SURFACE
h
g
PLAN VIEW
D
DATUM :
TOP OF BENCHTOP
i i j k
e
FRONT VIEW
0 5 10 20
inches
POWER CORD
LOCATION
C
20 7/8''
A
CLEARANCE : OVERHEAD CABINET (UNPROTECTED)
CLEARANCE : RANGEHOOD
CLEARANCE : OVERHEAD CABINET (PROTECTED)
CLEARANCE : OVERHEAD CABINET NOT DIRECTLY ABOVE COOKTOP
CLEARANCE : OVEN OR CABINETRY
f
PROFILE VIEW
POWER CORD
LOCATION
12'' INDUCTION COOKTOP
Model no:
CI122DTB2 (refer page 2 for metric measurements)
Product Dimensions
a Height of chassis (below top of counter)
B Overall width of cooktop
c Overall depth of cooktop
D Height from countertop datum to top of cooktop glass
e Width of chassis
f Depth of chassis
g Depth of front control panel
h Depth of cooktop cooking area
i Distance from side edges of cooktop to chassis
j Distance from front edge of cooktop to chassis
k Distance from back edge of cooktop to chassis
Minimum Clearances
Minimum clearance from side edges of cutout to nearest
combustible surface
Minimum clearance from rear edge of cutout to nearest
combustible surface
Minimum clearance from front edge of cutout to front edge of
counter
Minimum clearance below top of countertop to:
Top of oven* installed below cooktop or cabinetry
Top of drawer or other obstruction below cooktop
Minimum clearance from glass surface to:
- overhead cabinet centered above the cooktop (unprotected)
- overhead cabinet centered above the cooktop (protected)
- rangehood
Minimum clearance from glass surface to overhead cabinet not
directly above the cooktop
Minimum ventilation gap between bottom of counter and top of
cabinetry fronts (not shown)
*NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the
induction cooktop receives adequate air supply. For ventilation requirements please refer to the
installation manual.
Cutout Dimensions
Overall width of cutout
Overall depth of cutout**
**Note cutout position is centered to the cooktop width, but offset to the cooktop depth.
Cutout front depth is 3/8'' from the front edge of the product.
INDICATES CUTOUT -------------------------------------------------------
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
DATE: 28.08.2016
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm
(3/32''). Please read the installation manual for detailed information on
installing the product. For full installation instructions & specifications visit
fisherpaykel.com
DATA SHEET
CLEARANCE : COMBUSTIBLE SURFACE
h
g
D
DATUM :
TOP OF BENCHTOP
i i j k
FRONT VIEW
0 100 200 400
300
B
PLAN VIEW
e
millimetres
POWER CORD
LOCATION
C
530
A
CLEARANCE : OVERHEAD CABINET (UNPROTECTED)
CLEARANCE : RANGEHOOD
CLEARANCE : OVERHEAD CABINET (PROTECTED)
CLEARANCE : OVERHEAD CABINET NOT DIRECTLY ABOVE COOKTOP
CLEARANCE : OVEN OR CABINETRY
f
PROFILE VIEW
POWER CORD
LOCATION
12'' INDUCTION COOKTOP
Model no:
CI122DTB2 (refer page 1 for imperial measurements)
Product Dimensions
a Height of chassis (below top of counter)
B Overall width of cooktop
c Overall depth of cooktop
D Height from countertop datum to top of cooktop glass
e Width of chassis
f Depth of chassis
g Depth of front control panel
h Depth of cooktop cooking area
i Distance from side edges of cooktop to chassis
j Distance from front edge of cooktop to chassis
k Distance from back edge of cooktop to chassis
Minimum Clearances
Minimum clearance from side edges of cutout to nearest
combustible surface
Minimum clearance from rear edge of cutout to nearest
combustible surface
Minimum clearance from front edge of cutout to front edge of
counter
Minimum clearance below top of countertop to:
Top of oven* installed below cooktop or cabinetry
Top of drawer or other obstruction below cooktop
Minimum clearance from glass surface to:
- overhead cabinet centred above the cooktop (unprotected)
- overhead cabinet centred above the cooktop (protected)
- rangehood
Minimum clearance from glass surface to overhead cabinet not
directly above the cooktop
Minimum ventilation gap between bottom of counter and top of
cabinetry fronts (not shown)
*NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the
induction cooktop receives adequate air supply. For ventilation requirements please refer to the
installation manual.
Cutout Dimensions
Overall width of cutout
Overall depth of cutout**
**Note cutout position is centered to the cooktop width, but offset to the cooktop depth.
Cutout front depth is 10mm from the front edge of the product.
INDICATES CUTOUT -------------------------------------------------------
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
DATE: 28.08.2016
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm
(3/32''). Please read the installation manual for detailed information on
installing the product. For full installation instructions & specifications visit
fisherpaykel.com