Fisher Service Instructions for Fisher Digital Isolation Triple Offset Valve (TOV) Solution Manuals & Guides

Instruction Manual
D104341X012
Fisher Digital Isolation Solutions
December 2018
Service Instructions for Fisher™ Digital Isolation Triple Offset Valve (TOV) Solution
Contents
Introduction 1.................................
Scope of Manual 1..............................
Component Instruction and Maintenance Manuals 2. Actuator Mounting Bracket-to-Valve Bolt Torque 3..
Educational Services 4...........................
Parts Ordering 4................................
Figure 1. Fisher Digital Isolation TOV Solution
X1550
Introduction
Fisher Digital Isolation Solutions leverage Emerson’s automation expertise with time-tested products to provide a complete and dependable isolation valve solution for your most critical isolation, SIS, and ESD valve applications.
Scope of Manual
This instruction manual includes the web links for product specifications, installation and maintenance instructions for each component.
Do not install, operate or maintain this product without being fully trained and qualified in valve, actuator and accessory installation, operation and maintenance. To avoid personal injury or property damage it is important to carefully read, understand, and follow all of the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Emerson sales office
before proceeding.
www.Fisher.com
Fisher Digital Isolation Solutions
December 2018
Instruction Manual
D104341X012
Component Specifications
For product specifications click on the following web link (TOV Specs) where you will find the technical specifications documents for the components used on Fisher Digital Isolation Solutions products.
Component Instruction and Maintenance manuals
For Component Instruction and Maintenance manuals click on the following links (ASCO, TopWorx, DVC6200 SIS,
BETTIS
) where you will find the documents for the components used on Fisher Digital Isolation Solutions.
If a paper copy of component specifications or Instruction/Maintenance manuals is required please consult your Emerson sales office.
WARNING
Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations:
D Do not remove the actuator from the valve while the valve is still pressurized.
D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations.
D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure
on both sides of the valve. Drain the process media from both sides of the valve.
D Depending on the actuator construction, it will be necessary to manage the pneumatic actuator spring
pre-compression. It is essential to refer to the relevant actuator instructions in this manual to provide safe removal of the actuator from the valve.
D Use lock‐out procedures to be sure the above measures stay in effect while you work on the equipment.
D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out when removing the packing hardware or packing rings, or when loosening the packing box pipe plug.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
2
Instruction Manual
D104341X012
Fisher Digital Isolation Solutions
Actuator Mounting Bracket-to-Valve Bolt Torque
SA 193-B7/zinc plated
Fastener Size N•m Ft•lb
5/16” 30 22
3/8” 53 39
7/16” 84 62
1/2” 130 96
9/16” 176 130
5/8” 230 170 3/4” 380 280
1” 786 580
1-1”4 1424 1050
SA193 Grade B8 CL2
Fastener Size N•m Ft•lb
5/16" 19 14
3/8" 35 26
7/16" 56 41
1/2" 85 63
9/16" 123 91
5/8" 163 120 3/4" 258 190
1" 536 395
1-1/4" 969 715
December 2018
SA 193-B7/zinc plated
Fastener Size N•m Ft•lb
M10 69 51 M12 116 86 M16 241 178 M20 413 305 M24 656 484 M30 1164 859
SA193 Grade B8 CL2
Fastener Size N•m Ft•lb
M10 48 35 M12 80 59 M16 165 122 M20 284 209 M24 451 333 M30 800 590
Lubrication should always be used with the SA 193-B8 Class 2 bolt material to prevent galling.
3
Fisher Digital Isolation Solutions
December 2018
Instruction Manual
D104341X012
Educational Services
For information on available courses for Fisher Digital Isolation products, as well as a variety of other products, contact: Emerson Automation Solutions
Educational Services - Registration Phone: 1-641-754-3771 or 1-800-338-8158 E-mail: education@emerson.com emerson.com/fishervalvetraining
Part Ordering
Each Fisher Digital Isolation package has a unique Fisher serial number. When corresponding with your Emerson sales
office about this equipment, always mention the valve serial number.
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher and Digital Isolation are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay, 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore
www.Fisher.com
4
E 2018 Fisher Controls International LLC. All rights reserved.
Loading...