Fisher Instruction Manual: Fisher easy-Drive 200L Quick Start Guide, Quick Start Guide: Fisher easy-Drive 200L Manuals & Guides

Quick Start Guide
D104725X012
easy-Drive 200L
March 2022
Fisher™ easy-Drive™ 200L Quick Start Guide
Mounting and travel configuration for your Fisher easy-Drive 200L actuator.
Before You Begin
Do not install, operate, or maintain a 200L actuator without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property
damage, it is important to carefully read, understand, and follow all the contents of this quick start guide, including all safety cautions and warnings. Refer to the Fisher easy-Drive 200L Instruction Manual
(D104331X012 installation in hazardous locations. If you have any questions about these instructions, contact your
Emerson sales office
WARNING
To avoid personal injury or property damage, keep hands and tools out of the actuator stem travel path. The actuator stem will move during calibration and positioning steps.
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal injury.
) for product specifications, custom setup information, maintenance procedures, and
before proceeding.
Note
Refer to easy-Drive 200L Instruction Manual (D104331X012 easy-Drive actuator as this will be needed to configure and calibrate the 200L.
) for wiring, Modbus setup and connecting the Configurator to an
www.Fisher.com
easy-Drive 200L
March 2022
Quick Start Guide
D104725X012
Ensure Actuator Stem is in the Proper Position Prior to Mounting and Coupling
Your 200L actuator has internal hard stops to limit maximum travel within the actuator. A new actuator will be shipped from the factory at 6% off the lower internal hard stop, which is the recommended mounting position.
Note
If you are mounting a new actuator that has never been positioned and is still in its recommended mounting position of 6% of maximum travel, you can begin at step 5.
To set the stand-alone 200L actuator to the recommended mounting position of 6% of maximum travel, follow steps 1-4:
Step 1. Ensure use of a stand-alone 200L
(must be actuator only, no valve body).
X1520-1
Step 3. Perform Span Calibration from
Calibration tab.
Step 2. Using the Fisher easy-Drive Configurator,
select the “System” tab and then “Advanced Settings.” Select the valve type “Stop-to-Stop” from the drop-down options and click “Apply.”
Step 4. Position actuator to 6% travel.
Note
Stop-to-Stop is used for positioning the actuator to 6% off the lower travel stop. Select proper valve type and travel after mounting the 200L to the valve body.