Fisher Instruction Manual: Service Instructions for Fisher Digital Isolation Trunnion Mounted Ball Valve (TMBV) Solution (Obsolete Product) Manuals & Guides

Instruction Manual
D104338X012
Fisher NL Valve
June 2019
Fisher™ Digital Isolation™ NL Trunnion Mounted Ball Valve (TMBV) (Obsolete Product)
Contents
Introduction 1.................................
Safety Instructions 1............................
Specifications 2................................
Parts Ordering 2................................
Installation 3..................................
Maintenance 4.................................
Introduction
The product covered in this document is no longer in production. This document, which includes the latest published version of the instruction manual, is made available to provide updates of newer safety procedures. Be sure to follow the safety procedures in this supplement as well as the specific instructions in the included instruction manual.
Part numbers in the included instruction manual should not be relied on to order replacement parts. For replacement parts, contact your Emerson sales office
For more than 30 years, Fisher products have been manufactured with asbestos‐free components. The included manual might mention asbestos containing parts. Since 1988, any gasket or packing which may have contained some asbestos, has been replaced by a suitable non‐asbestos material. Replacement parts in other materials are available from your sales office.
.
Safety Instructions
Please read these safety warnings, cautions, and instructions carefully before using the product.
These instructions cannot cover every installation and situation. Do not install, operate, or maintain this product without being fully trained and qualified in valve, actuator and accessory installation, operation and maintenance. To
avoid personal injury or property damage it is important to carefully read, understand, and follow all of the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact
your Emerson sales office before proceeding.
www.Fisher.com
Fisher NL Valve
June 2019
Instruction Manual
D104338X012
Specifications
This product was intended for a specific range of service conditions‐‐pressure, pressure drop, process and ambient temperature, temperature variations, process fluid, and possibly other specifications. Do not expose the product to service conditions or variables other than those for which the product was intended. If you are not sure what these conditions or variables are, contact your Emerson sales office other pertinent information that you have available.
for assistance. Provide the product serial number and all
Inspection and Maintenance Schedules
All products must be inspected periodically and maintained as needed. The schedule for inspection can only be determined based on the severity of your service conditions. Your installation might also be subject to inspection schedules set by applicable governmental codes and regulations, industry standards, company standards, or plant standards.
In order to avoid increasing dust explosion risk, periodically clean dust deposits from all equipment.
When equipment is installed in a hazardous area location (potentially explosive atmosphere), prevent sparks by proper tool selection and avoiding other types of impact energy.
Parts Ordering
Whenever ordering parts for older products, always specify the serial number of the product and provide all other pertinent information that you can, such as product size, part material, age of the product, and general service conditions. If you have modified the product since it was originally purchased, include that information with your request.
WARNING
Use only genuine Fisher replacement parts. Components that are not supplied by Emerson should not, under any circumstances, be used in any Fisher product, because they may void your warranty, might adversely affect the performance of the product, and could cause personal injury and property damage.
2
Instruction Manual
D104338X012
Fisher NL Valve
June 2019
Installation
WARNING
D Personal injury or equipment damage caused by sudden release of pressure or bursting of parts may result if the valve
assembly is installed where service conditions could exceed the limits given in the applicable product literature, the limits on the appropriate nameplates, or the mating pipe flange rating. Use pressure‐relieving devices as required by government or relevant industry codes and good engineering practices. If you cannot determine the ratings and limits for this product, contact your Emerson sales office
D To avoid personal injury, always wear protective gloves, clothing, and eyewear when performing any installation
operations.
D To avoid personal injury or property damage, use proper lifting and rigging practices while lifting, installing or
removing the valve assembly. Be sure to use lifting and rigging equipment properly sized and selected for the weight and configuration of the valve assembly or component being lifted.
D Personal injury could result from packing leakage. Valve packing was tightened before shipment; however, the packing
might require some readjustment to meet specific service conditions.
D Many rotary shaft valves are not necessarily grounded to the pipeline when installed in a flammable, hazardous, oxygen
service, or explosive atmospheres. An explosion is possible, due to the discharge of static electricity from the valve components. To avoid personal injury or property damage, make sure that the valve is grounded to the pipeline before placing the control valve assembly into service. Use and maintain alternate shaft‐to‐body bonding, such as a shaft‐to‐body bonding strap assembly.
D Rotary shaft valves are designed and intended for installation between flanges. Personal injury or property damage may
result from improper installation. To avoid personal injury or property damage caused by the sudden release of pressure or bursting of parts, do not use or install rotary shaft valves (including single lug constructions) for dead‐end service.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
D If installing into an existing application, also refer to the WARNING in the Maintenance section.
D When ordered, the valve configuration and construction materials were selected to meet particular pressure,
temperature, pressure drop, and controlled fluid conditions. Responsibility for the safety of process media and compatibility of valve materials with process media rests solely with the purchaser and end‐user. To avoid possible personal injury and because some valve/trim material combinations are limited in their pressure drop and temperature ranges, do not apply any other conditions to the valve without first contacting your Emerson sales office.
before proceeding.
CAUTION
D Ensure that the valve and adjacent pipelines are free of foreign material that could damage the valve seating surfaces.
3
Loading...
+ 5 hidden pages