Fisher™ 1061 Pneumatic Piston Rotary Actuator
with Style F & G Mounting Adaptations
Contents
Introduction1.................................
Scope of Manual1.............................
Description2.................................
Specifications2...............................
Educational Services3.........................
Principle of Operation3.........................
Installation3..................................
Actuator Mounting3..........................
Changing Actuator Mounting8..................
Pressure Connections9........................
Adjustment9..................................
Maintenance10................................
Disassembly11...............................
Assembly12..................................
Locking Mechanism14..........................
Installing the Locking Mechanism15.............
Operating the Locking Mechanism16............
Pipe‐Away Vent18..............................
Parts Ordering19...............................
Parts Kits19...................................
Actuator Repair Kits19.........................
Pipe‐Away Vent Retrofit Kits19..................
Parts List19...................................
Actuator Common Parts19.....................
Figure 1. Fisher 1061 Actuator with V500 Valve and
DVC6200 FIELDVUE™ Digital Valve Controller
W8380−2
Locking Mechanism Parts20....................
Pipe‐Away Vent Parts20........................
Piston/Piston Rod Torquing Fixture20............
Introduction
Scope of Manual
This instruction manual includes installation, adjustment, maintenance, and parts ordering information for the Fisher
1061 pneumatic piston rotary actuator with F and G mounting adaptations (see figure 1). Instructions for the control
valve, the auxiliary declutchable handwheel actuator, the valve positioner, and accessories are covered in separate
instruction manuals.
Do not install, operate, or maintain a 1061 actuator without being fully trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important tocarefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you
have any questions about these instructions, contact your Emerson sales office
proceeding.
www.Fisher.com
or Local Business Partner before
1061 F & G Actuator
June 2017
Table 1. Specifications
Instruction Manual
D100324X012
Available Configuration
Double‐acting pneumatic piston rotary actuator for
J throttling service when used with positioner, or
J on‐off service when used with switching devices
Size 130: J 76.2 (3), J 88.9 (3‐1/2)
Maximum Valve Shaft Rotation
J 90 degrees or J 60 degrees (travel stop required
for 60 degree rotation limit)
Size 80 and 100: J 44.5 (1‐3/4), J 50.8 (2), and
J 63.5 (2‐1/2)
1. The pressure/temperature limits in this manual and any applicable standard or code limitation for valves should not be exceeded.
Approximate Weights
Size 30: 22 kg (49 lb)
Size 40: 29 kg (63 lb)
Size 60: 39 kg (86 lb)
Size 68: 56 kg (123 lb)
Size 80: 122 kg (246 lb)
Size 100: 135 kg (298 lb)
Size 130: 299 kg (660 lb)
(1)
Description
The 1061 actuator is a double‐acting pneumatic piston rotary actuator for use with rotary‐shaft valves having splined
valve shafts. The 1061 actuator can be used for either throttling or on‐off applications.
The style G mounting bracket is for Fisher 9500 valves only. The style F mounting bracket is for all other rotary valves.
Specifications
Specifications are shown in table 1 for 1061 actuators. Specifications are stamped on the nameplate. Refer to the
actuator nameplate for the construction setting and serial number for the actuator when it originally came from the
factory.
2
Instruction Manual
D100324X012
1061 F & G Actuator
June 2017
Educational Services
For information on available courses for 1061 Style F and G actuators, as well as a variety of other products, contact:
Piston movement is accomplished by loading air pressure on one side of the piston, and unloading air pressure from
the other side of the piston. If no positioner is used with the control valve, a loading device, such as a 4‐way switching
valve, must be provided. Such a device is not furnished with the actuator.
Refer to the separate valve positioner instruction manual for the 1061 actuator principle of operation with positioner.
Installation
When an actuator and valve are shipped together, the actuator is normally mounted on the valve. Follow the valve
instructions when installing the control valve in the pipeline. If the actuator is shipped separately or if it is necessary to
mount the actuator on the valve, perform the procedures presented in the Actuator Mounting section.
WARNING
To avoid personal injury, always wear protective gloves, clothing, and eyewear when performing any installation
operations.
To avoid personal injury or property damage caused by bursting of pressure retaining parts, be certain the service
conditions do not exceed the limits given in table 1 or on the nameplate. Use pressure limiting or pressure relieving devices
to prevent the cylinder pressure from exceeding the maximum allowable cylinder operating pressure.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
Actuator Mounting
Use the following steps to connect a valve and actuator that have been ordered separately, or if the valve or actuator
were separated for maintenance purposes.
Key numbers used in this procedure are shown in figures 8, 9 and 11.
WARNING
Perform the steps in the WARNING at the beginning of the Maintenance section.
3
1061 F & G Actuator
June 2017
Instruction Manual
D100324X012
1. Refer to instructions in the appropriate valve instruction manual.
2. If a valve positioner is installed on the actuator, remove the positioner.
On the travel indicator side of the actuator:
3. Remove the cap screws and washers (keys 35 and 76), and remove the actuator cover (key 34). If an optional
manual handwheel actuator is being used, it will be removed with the cover.
4. If the lever (key 28) is attached to the rod end bearing (key 12), remove the cap screw and hex nut:
D For size 30, 40, 60, and 68 actuators, remove the cap screw and hex nut (keys 13 and 14).
D For size 80 and 100 actuators, remove the cap screw, washer, and hex nut (keys 13, 84, and 85).
D For size 130 actuators, remove the cap screw and locknut (keys 13 and 85).
On the valve side of the actuator:
5. The actuator is normally positioned vertically with the valve in a horizontal pipeline. Refer to figure 2 for available
mounting styles and positions that match your application. Also, refer to the lever/shaft orientation provided in the
valve instruction manual.
CAUTION
It is important, when installing the actuator on the valve, to be sure that the valve is positioned correctly.
D Note the actuator style, position, and lever in relationship to the valve body and drive shaft end marks (see step 13,
below).
D The valve internal components can be damaged if forced past its fully open or fully closed position.
6. Screw the mounting yoke (key 23) onto the actuator, and tighten the screws (key 24). Slide the actuator onto the
valve shaft, and secure the mounting yoke to the valve body with the valve mounting screws.
7. Tighten the valve mounting cap screws to the bolting torque values given in table 2.
8. Hold the valve in the correct position, and secure it with the cap screws (key 24).
4
Instruction Manual
D100324X012
VALVE SERIES OR DESIGNVALVE SERIES OR DESIGN
MOUNTINGACTION
Right‐Hand
Left‐Hand
Left‐Hand
(Optional)
1. PDTC—Push‐down‐to‐close, and PDTO—Push‐down‐to‐open.
2. A left hand ball will be required for the NPS 3 through 12 Series B and the NPS 14 to 20, with or without attenuator.
(2)
(1)
PDTC
PDTO
PDTC
PDTO
PDTC
PDTO
Figure 2. Mounting Styles and Positions
BALL/PLUG
ROTATION TO
CLOSE
CCW
CCW
CCW
CCW
CW
CW
V250V150, V200 & V300
A
B
NA
NA
NA
NA
A
B
D
C
C
D
STYLE A
CV500
V500
A
B
D
C
NA
NA
DISK/BALL
ROTATION TO
CLOSE
CW
CW
CW
CW
NA
NA
1
POSITION 1
1061 F & G Actuator
June 2017
V250
NA
NA
C
D
NA
NA
STYLE B
8510B, 8532,
8560
& 9500
B
A
C
D
NA
NA
STYLE D
LEFT‐HAND
STYLE C
MOUNTING
4
STYLE B
STYLE A
RIGHT‐HAND
FLOW
MOUNTING
STYLES
NOTES:
1
POSITION 1 IS STANDARD; POSITIONS 2 THROUGH 4 (SHOWN IN DOTTED LINES) ARE ALTERNATES.
2. BY Emerson Automation Solutions DEFINITION:
D FORWARD FLOW IS INTO THE FACE SIDE OF DISK , OR BALL SEALING SURFACE.
D REVERSE FLOW IS INTO THE HUB SIDE OF THE DISK OR BALL.
43A6506‐A
A1579‐5
POSITION 1
3
1
2
4
3
RIGHT‐HAND MOUNTING
STYLE DSTYLE C
1
POSITION 1
POSITION 1
1
2
4
4
33
LEFT‐HAND MOUNTING
FLOW
2
2
5
1061 F & G Actuator
June 2017
Instruction Manual
D100324X012
Table 2. Bolting Torque Values for Valve Mounting Cap Screws
VALVE SHAFT DIAMETERVALVE MOUNTING CAP SCREWS
mmInchNSmlbf‐ft
12.7 to 25.41/2 to 18065
31.8 & 38.11‐1/4 & 1‐1/2135100
44.5 & 50.81‐3/4 & 2183135
63.52‐1/2390290
76.2 & 88.93 & 3‐1/2745550
On the travel indicator side of the actuator:
9. Screw the left‐hand threaded hex nut (key 71) onto the piston rod (key 10) as far as possible.
10. Screw the turnbuckle (key 70) onto the piston rod as far as possible. Only finger‐tighten it, as this adjustment will
be changed in a later step.
11. Screw the hex nut (key 11) onto the rod end bearing. Then thread this assembly completely into the turnbuckle.
NOTE:
KEY 28, LEVER LOCKING SCREW CAP SCREW IS SHOWN IN FIGURES 9 AND 10.
13A6446‐A
A3041‐2
mm
(INCH)
12. To aid installation of the lever, apply lithium grease lubricant (key 93) to the valve shaft spline.
For size 80, 100 and 130 actuators, it may be necessary to rotate the set screw (key 82) clockwise slightly to spread the
split portion of the lever and allow installation on the valve shaft.
13. Refer to the appropriate valve instruction manual for lever/shaft orientation marks, and slide the lever into place.
Refer to figure 3 for the appropriate lever operating clearance.
DFor size 80, 100 and 130 actuators, when the lever is in place, back off the set screw (key 82) so the lever can be
clamped onto the valve shaft.
6
Instruction Manual
D100324X012
1061 F & G Actuator
June 2017
DFor all sizes: Hold the lever in position, and secure the assembly with the cap screw (key 29).
14. Rotate the lever until the cap screw hole is aligned with the rod end bearing (key 12). You may need to adjust the
turnbuckle to make this alignment.
15. For all actuator sizes, apply thread locking sealant (high strength) (key 83) to the cap screw (key 13) threads.
Table 3. Recommended Bolting Torques
ACTUATOR SIZE
KEY NUMBER
3102102102102123
6141414‐ ‐ ‐91
961136248‐ ‐ ‐1763
1134102102475542
13802712712711763
22236868169162
24348181271257
2981271271271970
35348181271257
411414141414
71102163253475542
86‐ ‐ ‐‐ ‐ ‐‐ ‐ ‐861‐ ‐ ‐
KEY NUMBERlbfSft
37575757575
6101010‐ ‐ ‐67
945100257‐ ‐ ‐1300
11257575350400
13602002002001300
22175050125120
24256060200190
2960200200200715
35256060200190
411010101010
7175120260350400
86‐ ‐ ‐‐ ‐ ‐‐ ‐ ‐635‐ ‐ ‐
3040 & 606880 & 100130
NSm
WARNING
Refer to table 3 for bolt torque requirements. Exceeding any torque requirements could damage actuator parts and impair
safe operation. Refer to the Warning at the beginning of the Installation section in this manual.
Note
If the cap screw key number is shown in table 3, torque the cap screws to the value shown in the table for final assembly.
16. Connect the lever to the rod end bearing with the cap screw and hex nut (keys 13 and 14) for size 30, 40, 60, and
68 actuators; with the cap screw, washer, and locknut (keys 13, 84, and 85) for size 80 and 100 actuators; or with
the cap screw and hex nut (keys 13 and 85) for size 130. Torque cap screw and hex nut to the value listed in table 3.
17. Note the valve disk or ball position and direction of rotation.
7
1061 F & G Actuator
June 2017
Instruction Manual
D100324X012
WARNING
To avoid possible personal injury, do not stroke the actuator while the cover (key 34) is off.
a. If no handwheel actuator is to be used, position the travel indicator (key 38) according to the valve disk or ball
position just noted. Replace the cover (key 34), and secure it with the washers and cap screws (keys 76 and 35). If the
holes in the cover and housing (key 21) do not align, temporarily loosen the cap screws (key 24) and shift the housing
slightly. Do not stroke the actuator while the cover is off.
b. If a manual handwheel actuator is to be used, refer to the separate instruction manual for mounting
instructions.
18. If the 1061 actuator is equipped with an auxiliary handwheel actuator, make certain that a cylinder bypass valve
(key 68, figure 10) is also used to equalize cylinder pressure during handwheel operation. Operating the handwheel
actuator by itself against the force of differential cylinder pressures is difficult or even impossible. Install a bypass
valve as shown in figure 10. If the actuator was equipped with a valve positioner, refer to the positioner instruction
manual mounting procedures.
Changing Actuator Mounting
The actuator is normally positioned vertically in a horizontal pipeline. However, four mounting styles and four
positions are possible for each style. See figure 2.
Be sure to refer to the appropriate valve instruction manual for lever/valve shaft orientation, when changing styles
and/or positions. Most mounting changes will require the actuator lever to change position in relationship to the valve
splined shaft. It is possible to damage the valve if the actuator drives the valve disk or ball past its fully open or fully
closed position.
Refer to the Actuator Mounting section, to disassemble and assemble the actuator when changing the style or
position of the actuator.
CAUTION
Do not use a hammer or similar tool to drive the lever (key 28) off the valve shaft. Driving the lever could damage internal
valve parts. On some valves, driving the lever off the shaft could move the valve disk or ball and bearings away from the
centered position, causing subsequent damage to valve parts as the valve is operated.
If necessary, use a wheel puller to remove the lever from the valve shaft. It is permissible to tap the wheel puller screw
lightly to loosen the lever, but hitting the screw with excessive force could damage valve parts or disrupt the centered
position of the valve disk or ball and bearings.
When changing styles and/or positions, most mounting changes will require the actuator lever to change position in
relationship to the valve splined shaft. It is possible to damage the valve if the actuator drives the valve disk or ball past its
fully open or fully closed position.
Key numbers referenced in the following procedures are shown in figures 8, 9 and 11.
Changing Styles
Style A is right‐hand mounted while Style D is left‐hand mounted. In all other ways, styles A and D are identical.
Style B is right‐hand mounted while Style C is left‐hand mounted. In all other ways, styles B and C are identical.
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.