IECEx Hazardous Area Approvals
Fisher
Hazardous Area Classifications and Special Instructions for “Safe Use” and Installation in Hazardous Locations
Certain nameplates may carry more than one approval, and each approval may have unique installation/wiring requirements and/or conditions of “safe use”. These special instructions for “safe use” are in addition to, and may override, the standard installation procedures. Special instructions are listed by approval.
Note
This information supplements the nameplate markings affixed to the product and the 4320 instruction manual (D103621X012 available from your Emerson sales office
Always refer to the nameplate itself to identify the appropriate certification.
4320 Wireless Position Monitor
),
, Local Business Partner, or www.Fisher.com.
WARNING
Failure to follow these conditions of “safe use” could result in personal injury or property damage from fire or explosion, and area re‐classification.
Intrinsically Safe
Monitor Version
Battery Sourced Power Module w/out Pneumatic Output External Power w/out Pneumatic Output
Ex ia IIC T3/T4/T5 Ga Ex ia IIC T5 Ga Install per control drawing GE59530 Install per control drawing GE59530  as shown in figure 1 and 2  as shown in figure 1 and 3 Enclosure: Type 4X, IP66 & IP67 Enclosure: Type 4X, IP66 & IP67 T3(Tamb 85_C), T4(Tamb 75_C), T5(Tamb 40_C) T5(Tamb 80_C) Temperature Range: -40_C to 85_C Temperature Range: -40_C to 80_C
Control Version
Battery Sourced Power Module with Pneumatic Output External Power with Pneumatic Output
Ex ia IIC T4/T5/T6 Ga Ex ia IIC T5 Ga Install per control drawing GE59530 Install per control drawing GE59530  as shown in figure 1 and 2  as shown in figure 1 and 3 Enclosure: Type 4X, IP66 & IP67 Enclosure: Type 4X, IP66 & IP67 T4(Tamb 50_C), T5(Tamb 46_C), T6(Tamb 31_C) T5(Tamb 50_C) Temperature Range: -20_C to 50_C Temperature Range: -20_C to 50_C
www.Fisher.com
4320 Wireless Position Monitor - IECEx
January 2018
Instruction Manual Supplement
D104307X012
Special Conditions of Use
The apparatus shall not be subjected to mechanical impacts or friction.
The piezo valve can be used with natural gas as control fluid provided that no gas-air mixtures are present in the pressure system.
Apparatus connection:
D The HART COMM terminals (WP1-WP2) can be only connected to intrinsically safe certified equipment.
D The external power terminal (J5) can be only connected to associated intrinsically safe certified equipment.
These combinations must be compatible regarding intrinsic safety rules.
Battery Sourced Power Module: The apparatus can only be powered with a module type GE57654X012 or GE57655X012 External Power: The apparatus may be powered externally via external power module GE61615X012
Install per control drawing GE59530 which includes intrinsic safety information.
Figure 1. Installation Drawing Notes; See Figure 2 for Battery Module Assembly & Figure 3 for External Power Option
INSTALLATION MUST BE IN ACCORDANCE WITH THE NATIONAL WIRING PRACTICES OF THE COUNTRY IN USE.
BARRIERS MUST BE CONNECTED PER MANUFACTURE'S INSTALLATION INSTRUCTIONS.
INTRINSICALLY SAFE APPARATUS MAY BE CONNECTED TO ASSOCIATED APPARATUS NOT SPECIFICALLY
EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR INTERCONNECTION IS THAT THE VOLTAGE (Ui) ANDTHE CURRENT (Ii) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THEVOLTAGE (Uo) AND CURRENT (Io) DEFINED BY THE ASSOCATED APPARATUS. IN ADDITION, THE SUM OFTHE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF EACH INTRINSICALLY SAFEAPPARATUS, AND THE INTERCONNECTING WIRING, MUST BE LESS THAN THE ALLOWABLE CAPACITANCE (Co) AND INDUCTANCE (Lo) DEFINED BY THE ASSOCIATED APPARATUS. IF THESE CRITERIA ARE MET, THEN THECOMBINATION MAY BE CONNECTED.
FORMULAS Ui > Uo
Ii > Io Ci + Ccable < Co Li + Lcable < Lo Pi > Po
RESISTANCE BETWEEN BARRIER GROUND AND EARTH GROUND MUST BE LESS THAN ONE OHM.
IF HAND-HELD COMMUNICATOR OR MULTIPLEXER IS USED, IT MUST BE APPROVED WITH ENTITY
PARAMETERS AND INSTALLED PER THE MANUFACTURER'S CONTROL DRAWING.
WARNING
THE APPARATUS ENCLOSURE CONTAINS ALUMINUM AND IS CONSIDERED TO CONSTITUTE A POTENTIAL RISK OF IGNITION BY IMPACT OR FRICTION. AVOID IMPACT AND FRICTION DURING INSTALLATION AND USE TO PREVENT RISK OF IGNITION.