This supplement contains information for converting L2, L2e, and L2sj level controller threaded NPT connections to
flange type connections.
Refer to the Maintenance section of the appropriate instruction manual for instructions on removing the sensor from
the controller, and disassembly of the sensor connector.
See figures 1, 2, and 3 for conversion and weld end details.
Note
Modification of the L2, L2e, or L2sj sensor to a flanged connection limits the pressure rating to the flange rating.
Refer to tables 1 and 3.
Ensure flanges are marked with the appropriate pressure rating.
Flange Orientation
Orient the controller so that the case is level. See figure 4 for the proper sensor orientation for flange welding.
WARNING
To maintain code/standard compliance, weld fabrication must meet the requirements of ASME Section IX. Failures to meet
these requirement could result in personal injury and/or property damage.
WARNING
To maintain compliance with NACE MR0175, weld fabrication must meet the requirements of NACE MR0175, paragraph 5.3.
Failure to meet these requirements could result in personal injury and/or property damage.
www.Fisher.com
L2, L2e, and L2sj Controller
March 2018
Figure 1. Typical Sensor Connection
Instruction Manual Supplement
D103277X012
CUT HERE TO
REMOVE THREAD
PREPARE SURFACE
FOR WELD
10C2006-A
Figure 2. Sensor Connections (mm)
1.6 $ 0.4
51.7
53.3
* 0.8
62.7 ) 2.3
12.7
15.2
CONTROLLER
7.6
6262
BORE AND MACHINE TO
GIVEN DIMENSIONS
1.6 $ 0.4
50.0
48.5
* 0.8
62.7 ) 2.3
12.7
15.2
CONTROLLER
11.2
62.7 ) 2.3
* 0.8
CONTROLLER
37.4
38.9
12.7
15.2
16.8
1.6 $ 0.4
66.5
NPS 2 ANSI SCHED 40
10C2006-A
NOTE:
SEE FIGURE 1 FOR A TYPICAL SENSOR CONNECTION
2
NPS 2 ANSI SCHED 80
NPS 2 ANSI SCHED XXS
Instruction Manual Supplement
D103277X012
Figure 3. Sensor Connections (Inches)
L2, L2e, L2sj Controller
March 2018
CONTROLLER
NPS 2 ANSI SCHED 40
10C2006-A
NOTE:
SEE FIGURE 1 FOR A TYPICAL SENSOR CONNECTION
CONTROLLER
Figure 4. Sensor Orientation for Flange Mounting
45_$2.5_
A
A
FLANGE ASSEMBLY
WITH 4 HOLE FLANGE
10C1996‐A
A
NOTE RELATION
OF TABS TO THE
BOLT PATTERN
NPS 2 ANSI SCHED 80
FLANGE ASSEMBLY
WITH 8 HOLE FLANGE
CONTROLLER
NPS 2 ANSI SCHED XXS
22.5_$2.5_
A
SECTION A‐A
CONNECTION USED FOR ORIENTATION
1
FLANGE
.12 max
O
.06
CONNECTION
1
3
L2, L2e, and L2sj Controller
March 2018
Instruction Manual Supplement
D103277X012
Installation
1. Install a suitable flange gasket.
2. Insert the displacer end of the sensor into the tank connection. Position the sensor so it can be bolted to the tank
flange.
3. Complete the sensor flange to tank flange connection.
Refer to figure 5 for NPS 2X2 flange dimensions and figure 6 for NPS 2X4 flange dimensions for the L2 controller,
figure 7 for NPS 2X2 flange dimensions and figure 8 for NPS 2X4 flange dimensions for the L2e controller, and figure 9
for NPS 2X4 flange dimensions for the L2sj controller.
Related Documents
D Fisher L2 Liquid Level Controller Instruction Manual (D103032X012)
D Fisher L2e Electric Level Controller Instruction Manual (D103531X012
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of
any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions,
Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Cernay, 68700 France
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
10
E LLC 2007, 2018 Fisher Controls International. All rights reserved.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.