Fisher Fisher GX Control Valve and Actuator System Manuals & Guides

Instruction Manual
D103175X012
GX Valve and Actuator
Fisher™ GX Control Valve and Actuator System
July 2018
Contents
Introduction 1.................................
Scope of Manual 1.............................
Description 1.................................
Educational Services 2.........................
Valve Installation 2.............................
Maintenance 4.................................
Actuator Maintenance 5........................
FIELDVUEt DVC2000 Digital Valve
Controller Mounting 11......................
Packing Maintenance 13........................
Replacing Packing (Pneumatic Actuators) 13.......
Replacing Packing (Electric Actuators) 16.........
Valve Trim Maintenance 19.....................
Bellows Maintenance 24........................
Handwheel Operation 26........................
Travel Stop Operation 27........................
Parts Ordering 42...............................
Parts Kits 42...................................
Parts List 43...................................
Introduction
Figure 1. Fisher GX Control Valve, Actuator, and FIELDVUE DVC2000 Digital Valve Controller
W8861
Scope of Manual
This instruction manual includes installation, maintenance, and parts information for the Fisher GX control valve and actuator system.
Do not install, operate, or maintain a GX valve without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Emerson sales office proceeding.
or Local Business Partner before
Description
The GX is a compact, state‐of‐the‐art control valve and actuator system, designed to control a wide range of process gases, vapors, and fluids.
The GX is rugged, reliable, and easy to select. It requires no actuator sizing ‐‐ the actuator selection is automatic once the valve body construction is selected.
The GX meets the requirements of both EN and ASME standards. It is available with a complete accessory package, including the FIELDVUE DVC2000 integrated digital valve controller.
www.Fisher.com
GX Valve and Actuator
July 2018
Table 1. Fisher GX Valve Specifications
Specifications EN ASME
Valve Body Size DN15, 20, 25, 40, 50, 80, 100, 150 NPS 1/2, 3/4, 1, 1-1/2, 2, 3, 4, 6
Pressure Rating PN 10 / 16 / 25 / 40 per EN 1092-1 CL150 / 300 per ASME B16.34
End Connections Flanged raised face per EN 1092-1 Flanged raised face per ASME B16.5
1.0619 steel ASME SA216 WCC steel
1.4409 stainless steel ASME SA351 CF3M stainless steel
CW2M (sizes DN25 through DN100 only) CW2M (NPS 1 through 4 only)
ASME SA352 LCC ASME SA352 LCC
ASTM A990 CN3MCu/ASME SA351 CN7M (Cast Alloy 20)
Valve Body/Bonnet Materials
Face-to-Face Dimensions
Shutoff per IEC 60534-4
and ANSI/FCI 70-2
Flow Direction Flow-up (Cavitrol™ III trim, Flow down)
Flow Control Characteristics Equal Percentage and Linear
Trim Style
Handwheel Available as an option
Travel Stop Available as an option
1. For 4.8 to 14 mm ports, Class VI shutoff is achieved without PTFE seat.
(sizes DN25 through DN100 only)
CD3MN Duplex SST
(sizes DN25 through DN100 only)
CF3 304L SST
(sizes DN25 through DN100 only)
Consistent with EN 558-1 Series 1
Metal seat - Class IV (standard)
Metal seat - Class V (optional)
PTFE seat - Class VI (optional)
Port Diameters Trim Style Description
4.8 mm Micro-Flow trim (unbalanced)
9.5, 14, 22 mm
36, 46 mm Port-Guided Plug (unbalanced)
70, 90, 136 mm Balanced Trim with Contoured plug or Unbalanced Port-Guided Plug
ASTM A990 CN3MCu/ASME SA351 CN7M (Cast Alloy 20)
Stem-Guided with Contoured Plug (unbalanced)
or Port-Guided with Cavitrol III trim (unbalanced)
Instruction Manual
D103175X012
(NPS 1 through 4 only)
CD3MN Duplex SST
(NPS 1 through 4 only)
CF3 304L SST
(NPS 1 through 4 only)
M35-2 (NPS 1 through 4 only)
N7M Alloy B2
(NPS 1 through 4 only)
Consistent with ANSI/ISA 75.08.01
(1)
Educational Services
For information on available courses for the Fisher GX valve and actuator system, as well as a variety of other products, contact:
Emerson Automation Solutions Educational Services - Registration Phone: 1-641-754-3771 or 1-800-338-8158 E-mail: education@emerson.com emerson.com/fishervalvetraining
Valve Installation
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal injury.
2
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Personal injury or equipment damage caused by sudden release of pressure or bursting of pressure retaining parts might result if service conditions exceed those for which the product was intended. To avoid injury or damage, provide a relief valve for over pressure protection as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this instruction manual.
CAUTION
This valve is intended for a specific range of pressures, temperatures and other application specifications. Applying different pressure and temperatures to the valve could result in parts damage, malfunction of the control valve or loss of control of the process. Do not expose this product to service conditions or variables other than those for which the product was intended. If you are not sure what these conditions are you should contact your Emerson sales office Partner for more complete specifications. Provide the product serial number (shown on the nameplate, figure 2) and all other pertinent information.
Figure 2. Fisher GX Nameplate Examples (Key 35)
or Local Business
GE01296‐H
GE41229-Sheet 1
WITHOUT SPRING INFORMATION
(USED PRIOR TO 2009)
WITH SPRING INFORMATION
GG12198-A
ELECTRIC ACTUATOR
WARNING
If you move or work on an actuator installed on a valve with loading pressure applied, keep your hands and tools away from the stem travel path to avoid personal injury. Be especially careful when removing the stem connector to release all loading on the actuator stem whether it be from air pressure on the diaphragm or compression in the actuator springs. Likewise take similar care when adjusting or removing any optional travel stop. Refer to the relevant actuator Maintenance Instructions.
3
GX Valve and Actuator
July 2018
If hoisting the valve take care to prevent people from being injured in case the hoist or rigging slips. Be sure to use adequately sized hoists and chains or slings to handle the valve.
Instruction Manual
D103175X012
1. Before installing the valve, inspect it to be certain that the valve body cavity is free of all foreign material. Clean out all pipelines to remove scale, welding slag and other foreign material.
2. The control valve assembly may be installed in any orientation unless limited by seismic criteria. However, the normal method is with the actuator vertical above the valve. Other positions may result in uneven trim wear, and improper operation. With some valves, the actuator may also need to be supported when it is not vertical. For more information, consult your Emerson sales office
or Local Business Partner. Flow through the valve must be in the
direction indicated by the arrow cast on the valve.
3. Use accepted piping practices when installing the valve in the pipeline. Use a suitable gasket between the valve and the pipeline flanges.
4. If continuous operation is required during inspection or maintenance, install isolating valves on either side of the control valve with a bypass valve to control the flow while the control valve is receiving maintenance.
WARNING
Personal injury could result from packing leakage. Valve packing is tightened before shipment; however the packing might require some readjustment to meet specific service conditions.
Maintenance
WARNING
Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations:
D Do not remove the actuator from the valve while the valve is still pressurized. D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations to avoid personal
injury.
D Disconnect any operating lines providing air pressure, electric power or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Use bypass valves or completely shut off the process to isolate the valve from the process pressure. Relieve the process
pressure from both sides of the valve.
D Depending on the actuator construction, it will be necessary to manage the pneumatic actuator loading pressure and
any actuator spring pre‐compression. It is essential to refer to the relevant actuator instructions in this manual to ensure safe removal of the actuator from the valve.
D Use lock‐out procedures to be sure that the above measures stay in effect while you work on the equipment. D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
Note
Whenever a gasket seal is disturbed by removing or shifting gasketed parts, install a new gasket during reassembly. This ensures a good gasket seal because the used gasket may not seal properly.
4
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Actuator Maintenance
For electric actuators, see the supplier's instruction manual.
The following sections provide procedures for actuator maintenance. Refer to figures 18, 19, 20, and 21.
The actuator soft parts may require periodic replacement. This includes the diaphragm (key 10), diaphragm O-ring (key 109), actuator rod bushing (key 19), and the actuator rod seal (key 20).
If the actuator stroking direction (air‐to‐open or air‐to‐close) is unknown, refer to the nameplate on top of the actuator casing and figure 2.
There are several optional actuator constructions, depending on supply pressure. Refer to the nameplate on the top of the actuator to determine the construction installed. Refer to figure 3 and table 2 for proper spring configuration.
Note
Older GX actuator nameplates do not contain spring configuration information. If you require replacement springs or wish to switch to an optional actuator construction, consult your Emerson sales office
or Local Business Partner.
Note
When the GX actuator is equipped with the integrated FIELDVUE DVC2000 digital valve controller (figure 1), additional considerations may be required. Refer to the FIELDVUE DVC2000 Digital Valve Controller Mounting section of this manual for additional instruction.
Actuator Disassembly (For Air‐to‐Open Constructions ‐ see figures 18 or 19)
1. Connect a separate air supply to the lower diaphragm casing via the air supply connection on the yoke (as shown in figure 18 or 19) and apply sufficient air pressure to raise the valve plug/stem off the seat to mid‐travel.
2. Remove the stem connector nut half (key 23), stem connector bolt half (key 24), and travel indicator (key 26).
3. Push the valve plug/stem (key 3) down until it contacts the seat.
4. Loosen the locknut (key 28) and thread the stem adjustor nut (key 27) down until it clears the top of the valve plug/stem (key 3).
5. Shut off the air pressure and disconnect the separate air supply to the lower diaphragm casing (as shown in figure 18 or 19).
WARNING
To avoid personal injury or property damage due to actuator springs (keys 12 and 82) being under compression, remove the long cap screws (key 16) last.
The upper actuator casing may remain fixed to the diaphragm and lower casing during disassembly, even if the casing cap screws have been loosened. If this happens, the actuator springs are still under compression. The upper casing could suddenly come loose and jump, due to the compressed energy of the springs. If the upper casing is stuck to the diaphragm and lower casing when you begin loosening the casing cap screws, pry the casings apart with a prying tool. Always ensure that the springs are dispersing energy and the upper casing is moving against the long bolts during disassembly.
5
GX Valve and Actuator
July 2018
Figure 3. Spring Configuration
Instruction Manual
D103175X012
GG00398-B
6. Remove the short actuator casing cap screws and hex nuts (keys 17 and 18) first. Once these have been removed from the actuator assembly, carefully remove the long actuator cap screws and hex nuts (keys 16 and 18), alternating between them to gradually release the spring energy (compression).
7. Remove the upper diaphragm casing (key 9) and the actuator springs (key 12 and/or 82).
8. Lift off the actuator stem/diaphragm assembly (includes keys 22, 11, 10, 14, 13, 109, and 15) and remove the cap screw (key 14), actuator spacer (key 13), actuator rod (key 22), and washer (key 15).
9. Replace the diaphragm (key 10), diaphragm O-ring (key 109), actuator rod bushing (key 19), and actuator rod seal (key 20), as needed.
6
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Actuator Disassembly (For Air‐to‐Close Constructions ‐ see figure 20 or 21)
1. Remove the stem connector nut half (key 23), stem connector bolt half (key 24), and travel indicator (key 26).
WARNING
To avoid personal injury or property damage due to actuator springs (key 12) being under compression, remove the long cap screws (key 16) last.
The upper actuator casing may remain fixed to the diaphragm and lower casing during disassembly, even if the casing cap screws have been loosened. If this happens, the actuator springs are still under compression. The upper casing could suddenly come loose and jump, due to the compressed energy of the springs. If the upper casing is stuck to the diaphragm and lower casing when you begin loosening the casing cap screws, pry the casings apart with a prying tool. Always ensure that the springs are dispersing energy and the upper casing is moving against the long bolts during disassembly.
2. Remove the short actuator casing cap screws and hex nuts (keys 17 and 18) first. Once these have been removed from the actuator assembly, carefully remove the long actuator cap screws and hex nuts (keys 16 and 18), alternating between them to gradually release the spring energy (compression).
3. Remove the upper diaphragm casing (key 9).
4. Lift off the actuator stem/diaphragm assembly (includes keys 22, 11, 10, 14, 13, 109, and 15) and remove the cap screw (key 14), actuator spacer (key 13), actuator rod (key 22), and washer (key 15).
5. Remove the actuator springs (key 12 and/or 82).
6. Replace the diaphragm (key 10), diaphragm O-ring (key 109), actuator rod bushing (key 19), and actuator rod seal (key 20), as needed.
Table 2. Actuator Spring Configuration Based on Minimum Supply Pressure
ACTUATOR SIZE
225 20
225 20
750 20
750 20
750 40
750 40
1200 40 or 60
1. Only applicable to actuators with spring information on the nameplate (see figure 2).
2. Only applicable to Cavitrol III constructions.
TRAVEL
mm Air‐to‐Open Air‐to‐Close
STEM MATERIAL
S20910, N05500
S31603
S31803, N10675,
N06022
S20910, N05500
S31603
S31803, N10675,
N06022
S20910, N05500
S31603
S31803, N10675,
N06022
S20910, N05500
S31603
MINIMUM SUPPLY
PRESSURE
4 bar (58 psi)
3 bar (44 psi) A4 A3 2 bar (29 psi) A3 A2 4 bar (58 psi) A6 A3 3 bar (44 psi) A4 A3 2 bar (29 psi) A3 A2
4 bar (58 psi)
3 bar (44 psi) B6 B4 2 bar (29 psi) B4 B4 4 bar (58 psi) B4 B4 3 bar (44 psi) B4 B4 2 bar (29 psi) B4 B4 4 bar (58 psi) C12 C6 3 bar (44 psi) C8 C3 2 bar (29 psi) C4 C3 4 bar (58 psi) C8 C6 3 bar (44 psi) C8 C3 2 bar (29 psi) C4 C3 4 bar (58 psi) D15 D15 3 bar (44 psi) D15 D15 2 bar (29 psi) N/A N/A
(1)
SPRING CONFIGURATION
A6 A3
(2)
A4
B6 B4
(2)
B6
A4
B6
(2)
(2)
7
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
Table 3. Fisher GX Maximum Rated Travel
ACTUATOR SIZE NUMBER OF CASING BOLTS
225 6 20
750 10 20 or 40
1200 16 40 or 60
TRAVEL
mm
Table 4. Body Nut (Key 7) Torque Requirements
VALVE SIZE
DN15, 20, 25 (NPS 1/2, 3/4, 1) 45.5 33.5
DN40 (NPS 1‐1/2) 79.8 58.9
DN50 (NPS 2) 79.8 58.9
DN80 (NPS 3) 163 120
DN100 and DN150 (NPS 4 and 6) 282 208
NSm lbfSft
TORQUE
Table 5. Yoke/Extension Bonnet Nut (Key 46) Torque Requirements (used on Extension Bonnet and Bellows Bonnet constructions)
VALVE SIZE
DN15, 20, 25, 40, and 50 (NPS 1/2, 3/4, 1, 1‐1/2, and 2) 79.8 58.9
DN80 and DN100 (NPS 3 and 4) 163 120
NSm lbfSft
TORQUE
Actuator Assembly For Air‐to‐Open Constructions (or to Change Action to Air‐to‐Open ‐ see figure 18 or 19)
1. Install the diaphragm (key 10) on the diaphragm plate (key 11). Insert the cap screw (key 14) through the actuator spacer (key 13) and place this assembly through the diaphragm/diaphragm plate assembly.
2. Place the diaphragm O-ring (key 109) and the washer (key 15) over the center hole of the diaphragm, so that the convex part of the washer is facing down toward the diaphragm and contains the O-ring. Ensure the convex part of the washer is guided in the diaphragm center hole as shown in figure 18 or 19.
3. Screw the actuator rod (key 22) onto the cap screw (key 14) and torque to 80 NSm (59.1 lbfSft). Install the actuator stem/diaphragm assembly back into the actuator yoke (key 8).
4. Place the actuator springs (key 12 and/or 82) onto the spring locators in the diaphragm plate (key 11). See figure 3 and table 2 for proper spring quantity and arrangement.
D If the nameplate does not contain spring information, use the same quantity and arrangement as originally installed.
5. Install the upper diaphragm casing (key 9) so that the ribs on the top of the upper diaphragm casing are perpendicular with the yoke legs.
DFor size 225 and 750 actuators, install the 2 long cap screws (key 16) and hex nuts (key 18) 180 degrees apart from each other and in line with the actuator yoke legs.
DFor size 1200 actuators, install the 4 long cap screws (key 16) and hex nuts (key 18) 90 degrees from each other, with two of them in line with the actuator yoke legs.
6. Tighten the long cap screws (key 16) and hex nuts (key 18), alternating between them to gradually compress the springs, until the two casing halves and diaphragm touch.
7. Install the remaining short cap screws (key 17) and hex nuts (key 18) to the casing.
8. Tighten the actuator casing cap screws evenly using a cross‐tightening procedure. Torque to 55 NSm (40 lbfSft).
8
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
9. If you had previously removed the actuator assembly from the valve, place the actuator assembly back onto the valve body (key 1). Install the four body nuts (key 7), but tighten them only finger‐tight.
10. Connect a separate air supply to the actuator air supply connection (as shown on the yoke in figure 18 or 19) and apply sufficient air pressure to raise the actuator rod (key 22) to the travel stop.
Note
If converting from air‐to‐close to air‐to‐open action, first move the vent cap (key 21) from the air supply connection on the yoke leg (see figure 20 or 21) to the top of the casing (see figure 18 or 19).
11. For standard bonnet constructions (figures 18, 19, 20, and 21), tighten the body nuts (key 7) evenly using a cross‐tightening procedure. See table 4 for torque requirements. For extension and bellows bonnet constructions (figures 22 and 23), tighten the bonnet nuts (key 46) evenly using a cross‐tightening procedure. See table 5 for torque requirements.
12. With the valve plug/stem (key 3) on the seat, thread the stem adjustor nut (key 27) up until it is the rated travel distance specified in table 3 from the actuator rod (key 22). Thread the locknut (key 28) up against the stem locknut and tighten per table 6.
Table 6. Stem Connector Torque Values
PART STEM MATERIAL
M8 Stem Connector Cap Screws All 35 26
M10 Stem Connector Jam Nut
(Rie 4606 Coated)
M14 Stem Connector Jam Nut
S31603, S20910, N05500 48 35 N06022, S31803, N10675 35 26 S31603, S20910, N05500 175 129
N06022, S31803, N10675 138 102
NSm LbfSft
TORQUE
13. Stroke the actuator rod until it contacts the stem adjuster nut (key 27) and install the stem connector halves and travel indicator (keys 23, 24, and 26) with the cap screws (key 25). Install the stem connector halves in the proper orientation so that when looking at the inside of the stem connector halves, the flats are down and the beveled surfaces are up.
14. Align the pointer of the travel indicator (key 26) with the appropriate mark on the travel scale.
15. Tighten the stem connector cap screws (key 25) to 35 NSm (26 lbfSft).
16. Release the actuator pressure.
Note
For air‐to‐open action, the air supply tubing must be connected to the actuator yoke at the air supply connection, see figure 18 or
19. (If converting from air‐to‐close to air‐to‐open, the tubing will need to be re‐routed to this location).
9
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
Actuator Assembly For Air‐to‐Close Constructions (or to Change Action to Air‐to‐Close ‐ see figure 20 or 21)
1. Position the upper diaphragm casing (key 9) upside down on the bench so that it lays flat and not off balance.
Note
If converting from air‐to‐open to air‐to‐close action, first move the vent cap (key 21) from the top of the casing (see figure 18 or
19) and thread into the air supply connection on the yoke leg (see figure 20 or 21).
2. Install the diaphragm (key 10) on the diaphragm plate (key 11). Place the diaphragm O-ring (key 109) and the washer (key 15) over the center hole of the diaphragm, so that the convex part of the washer is facing down toward the diaphragm and contains the O-ring. Ensure the convex part of the washer is guided in the diaphragm center hole as shown in figure 20 or 21.
3. Insert the cap screw (key 14) through the washer and diaphragm, install the actuator spacer (key 13), and screw the actuator rod (key 22) onto the cap screw (key 14) finger‐tight.
4. Radially align the spring locators in the diaphragm plate assembly (key 11) with the casing cap screw holes in the diaphragm (key 10). This will ensure that the springs do not cover the air path in the yoke.
5. Torque the cap screw (key 14) to the actuator rod (key 22) to 80 NSm (59.1 lbfSft) and lay this assembly into the upper diaphragm casing (key 9).
6. Place the actuator springs (key 12 and/or 82) onto the spring locators in the diaphragm plate (key 11). See figure 3 and table 2 for proper spring quantity and arrangement.
D If the nameplate does not contain spring information, use the same quantity and arrangement as originally installed.
7. Remove and replace the actuator rod bushing (key 19) and actuator rod seal (key 20) in the actuator yoke (key 8), if necessary.
8. Set the actuator yoke (key 8) down onto the assembly that is resting in the upper diaphragm casing (key 9) so that the yoke legs are perpendicular with the ribs on the top of the upper diaphragm casing (key 9).
DFor size 225 and 750 actuators, install the 2 long cap screws (key 16) and hex nuts (key 18) 180 degrees apart from each other and in line with the actuator yoke legs.
DFor size 1200 actuators, install the 4 long cap screws (key 16) and hex nuts (key 18) 90 degrees from each other, with two of them in line with the actuator yoke legs.
9. Tighten the long cap screws (key 16) and hex nuts (key 18), alternating between them to gradually compress the springs, until the two casing halves and diaphragm touch.
10. Install the remaining short cap screws (key 17) and hex nuts (key 18) to the casing.
11. Tighten the actuator casing cap screws evenly using a cross‐tightening procedure. Torque to 55 NSm (40 lbfSft).
12. If you had previously removed the actuator assembly from the valve, place the actuator assembly back onto the
valve body (key 1). For standard bonnet constructions (figures 18, 19, 20, and 21), install the body nuts (key 7) and tighten evenly using a cross‐tightening procedure. See table 4 for torque requirements. For extension and bellows bonnet constructions (figures 22 and 23), install the bonnet nuts (key 46) and tighten evenly using a cross‐tightening procedure. See table 5 for torque requirements.
13. With the valve plug/stem (key 3) in the closed position (on the seat), thread the stem adjustor nut (key 27) up until it is at the rated travel (see table 3) from the actuator rod (key 22). Thread the locknut (key 28) up against the stem locknut and tighten per table 6.
10
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
14. Stroke the actuator rod until it contacts the stem adjuster nut (key 27) and install the stem connector halves and travel indicator (keys 23, 24, and 26) with the cap screws (key 25). Install the stem connector halves in the proper orientation so that when looking at the inside of the stem connector halves, the flats are down and the beveled surfaces are up.
15. Align the pointer of the travel indicator (key 26) with the appropriate mark on the travel scale.
16. Tighten the stem connector cap screws (key 25) to 35 NSm (26 lbfSft).
Note
For air‐to‐close action, the air supply tubing must be connected to the actuator upper casing at the air supply connection, see figure 20 or 21. (If converting from air‐to‐open to air‐to‐close, the tubing will need to be re‐routed to this location).
FIELDVUE DVC2000 Digital Valve Controller Mounting
This section provides instruction on mounting the FIELDVUE DVC2000 digital valve controller to the GX control valve. For further detail on the operation and maintenance of the DVC2000, refer to the DVC2000 instruction manual.
The FIELDVUE DVC2000 digital valve controller mounts directly to an interface pad on the GX actuator yoke leg, eliminating the need for mounting brackets (see figure 1). Internal passageways in the actuator route the pneumatic output to the actuator casing, which eliminates the need for external air supply tubing in the air‐to‐open (spring‐to‐close) constructions. (The GX will also accommodate other valve positioners, using the NAMUR mounting pads on the side of the yoke legs.)
Figure 4. DVC2000 Digital Valve Controller Mounting Details
FOR AIR‐TO‐OPEN, INSTALL THE O‐RING SEAL
B: INTEGRAL MOUNTING PNEUMATIC OUTPUT PORT (R1/8 PLUG)
A: EXTERNAL PNEUMATIC OUTPUT PORT (1/4 NPT OR G1/4 PLUG)
W9019
BEFORE MOUNTING TO THE GX ACTUATOR
POLE PIECES
M8 MOUNTING BOLTS
The DVC2000 features linkage‐less position feedback when mounted to the GX control valve. There are no touching parts between the controller and the valve stem, which simplifies controller installation. If maintenance is required, the DVC2000 can be easily removed from the valve.
In the air‐to‐open (spring‐to‐close) configuration, the air signal to the actuator casing is supplied through the air supply connection on the GX actuator yoke leg (see figure 18 or 19). In the air‐to‐close (spring‐to‐open) configuration,
11
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
the air signal is supplied to the actuator through the air supply connection on the top of the actuator casing (see figure 20 or 21).
For an air‐to‐open construction, a DVC2000 will mount to the actuator (figure 18 or 19). The air signal is transmitted to the lower casing through the pneumatic passageway marked “air supply connection” in figure 18 or 19.
For an air‐to‐close construction, DN15 through DN100 (NPS 1/2 through 4) only: in the actuator design (figure 20 or
21), the pneumatic signal is connected directly to the air supply connection in the upper actuator casing. The yoke is symmetrical and the air passageways serve as a vent, whereby the DVC2000 can be easily moved from one side of the valve to the other without rotating the actuator.
DVC2000 Mounting Procedures
Steps A and B of the following instructions apply to the actuator construction shown in figures 18, 19, 20, and 21.
A. Mounting the DVC2000 to an air‐to‐open GX actuator (spring‐to‐close) (see figure 4 and figure 18 or 19):
1. Attach the magnetic feedback array (supplied with the DVC2000) to the valve stem connector using the alignment template (supplied with the mounting kit) for accurate alignment.
2. Remove the plug (R1/8) from the back of the DVC2000 housing (Port B in figure 4). This pneumatic output port on the DVC2000 lines up with the integral GX actuator air supply connection (see figure 18 or 19).
3. Install the plug (either G1/4 or 1/4 NPT, included in the mounting kit) to the external output pneumatic port (Port A in figure 4).
4. Remove the digital valve controller's cover.
5. Using a 6mm hex wrench, attach the digital valve controller to the GX actuator mounting pad on the side that has the open pneumatic port. Be sure to place the O‐ring seal between the digital valve controller's pneumatic output and the actuator mounting pad (Port B, as shown in figure 4). Pneumatic tubing is not required because the air passages are internal to the actuator. Also, install the insulating gaskets around the mounting bolts.
6. Check for clearance between the magnet assembly and the DVC2000 feedback slot. The magnet assembly should be positioned such that the index mark in the feedback slot of the DVC2000 housing is between the valid range on the magnet assembly throughout the range of travel. (See figure 4).
B. For air‐to‐close GX actuator (spring‐to‐open) (see figure 4 and figure 20 or 21):
1. Attach the magnetic feedback array (supplied with the DVC2000) to the valve stem connector using the alignment template (supplied with the mounting kit) for accurate alignment.
2. In the air‐to‐close configuration it is required that an R1/8 plug be installed into the integral mount pneumatic port on the back of the DVC2000 housing (Port B of figure 4).
3. Remove the digital valve controller's cover.
4. Using a 6mm hex wrench, attach the digital valve controller to the GX actuator mounting pad.
Note
The O‐ring seal and G1/4 or 1/4 NPT plugs (supplied in the mounting kit) are not used with this actuator construction.
5. Check for clearance between the magnet assembly and the DVC2000 feedback slot. The magnet assembly should be positioned such that the index mark on the pole pieces (back of the controller housing) is between the marks on the magnet assembly throughout the range of travel. (See figure 4.)
6. Install tubing between the external pneumatic output connection of the DVC2000 (Port A of figure 4) to the air supply connection (see figure 20 or 21) on top of the actuator casing.
12
Instruction Manual
D103175X012
When changing actuator action:
When field converting a GX actuator from air‐to‐open to air‐to‐close closed (or vice‐versa), you will need to change the plugs for the pneumatic passages in the DVC2000 housing.
D To convert from air‐to‐close to air‐to‐open (spring‐to‐close), remove the R1/8 pneumatic plug on the back of the DVC2000 housing and install an O‐ring (Port B of figure 4). Plug the external pneumatic output with a 1/4 NPT or G1/4 plug (depending on the housing version). (Port A of figure 4.)
D To convert from air‐to‐open to air‐to‐close (spring‐to‐open), remove the external pneumatic plug (1/4 NPT or G1/4 plug, depending on the housing version from Port A of figure 4). Install an R1/8 plug on the back of the DVC2000 housing (Port B of figure 4). Install tubing between the pneumatic output connection of the DVC2000 (Port A) to the air supply connection on top of the actuator casing (see figure 20 or 21).
GX Valve and Actuator
July 2018
Packing Maintenance
Key numbers refer to figures 15, 18, 19, 20, 21, 22, and 23.
Packing Adjustment
For ENVIRO-SEAL™ spring‐loaded single PTFE V‐ring packing (figure 15) or for ENVIRO-SEAL graphite ULF packing (figure 16), the Belleville spring pack (key 34) maintains a sealing force on the packing. If leakage is detected around the packing follower (key 29) check to be sure that the packing follower (key 29) is tight. Using a wrench, tighten the packing follower (key 29) in 1/4 turn intervals until the leakage is stopped. If leakage cannot be stopped in this manner, proceed to the Replacing Packing section in this manual.
Replacing Packing (Pneumatic Actuators)
This section provides instruction on replacing packing in standard bonnets, extension bonnets, and bellows extension bonnets.
Isolate the control valve from the line pressure, release pressure from both sides of the valve body and drain the process media from both sides of the valve. Shut off all pressure lines to the actuator and release all pressure from the actuator. Use lock‐out procedures to ensure that the above measures stay in effect while you work on the equipment.
1. For air‐to‐open constructions:
a. Connect a separate air supply to the lower diaphragm casing via the air supply connection on the yoke (as shown
in figure 18 or 19) and apply sufficient air pressure to raise the valve plug/stem off the seat to mid travel.
b. Remove the stem connector nut half (key 23), stem connector bolt half (key 24), and travel indicator (key 26).
c. Push the valve plug stem (key 3) down until it contacts the seat.
d. Loosen the locknut (key 28) and thread the stem adjustor nut (key 27) down until it clears the top of the valve
plug stem (key 3).
e. Shut off the air pressure and disconnect the separate air supply to the lower diaphragm casing (as shown in figure
18 or 19).
2. For air‐to‐close constructions, as shown in figure 20 or 21, remove the stem connector nut half (key 23), stem
connector bolt half (key 24), and travel indicator (key 26).
WARNING
To avoid personal injury or property damage by uncontrolled movement of the actuator yoke (key 8), loosen the body/yoke nuts (figures 18, 19, 20, and 21, key 7) or bonnet/yoke nuts (figures 22 and 23, key 46) by following the instructions in the
13
GX Valve and Actuator
July 2018
next step. Do not remove a stuck actuator yoke by pulling on it with equipment that can stretch or store energy in any other manner. The sudden release of stored energy can cause uncontrolled movement of the actuator yoke.
Note
The following step also provides additional assurance that the valve body fluid pressure has been relieved.
Instruction Manual
D103175X012
3. For standard bonnet constructions (figures 18, 19, 20, and 21), body nuts (key 7) attach the actuator yoke (key 8)
to the valve body (key 1). Loosen these nuts approximately 3mm (1/8 inch).
For extension and bellows bonnet constructions, bonnet nuts (key 46) attach the actuator yoke (key 8) to the extension bonnet (key 39). Loosen these nuts approximately 3mm (1/8 inch).
4. Then loosen the valve‐to‐yoke gasketed joint by either rocking the actuator yoke or prying between the valve and actuator yoke. Work the prying tool around the actuator yoke until it loosens.
WARNING
If there is evidence of process fluid under pressure leaking from the joint, retighten the valve body/joint nuts and return to the Warning at the beginning of the Maintenance section to ensure proper steps have been taken to isolate the valve and relieve process pressure, thus avoiding property damage or personal injury.
5. If no fluid leaks from the joint, loosen the packing follower (key 29) two turns to relieve the packing compression load.
6. For standard bonnet constructions (figures 18, 19, 20, and 21), remove the body nuts (key 7) completely. For extension and bellows bonnet constructions (figures 22 and 23), remove the bonnet nuts (key 46) completely.
CAUTION
To avoid property damage, place the actuator yoke on a protective surface, as described in the following procedure.
7. Carefully lift off the actuator yoke and set it on a protective surface to prevent damage. For standard bonnet constructions, if the bonnet (key 4) together with the valve stem plug assembly has a tendency to lift with the actuator yoke, ensure it does not drop from the actuator.
For extension and bellows constructions, ensure the bonnet (key 4) does not lift with the actuator yoke. For DN150 balanced constructions, if the bonnet, guide sleeve, or valve stem assembly have a tendency to lift with
the actuator yoke, ensure they do not drop from the actuator.
CAUTION
For extension and bellows bonnet constructions, lifting the bonnet with the actuator yoke may cause possible damage to the valve plug and to the bellows.
8. Remove the stem adjustor nut (key 27) and locknut (key 28).
9. For standard bonnet constructions, remove the bonnet and the valve plug/stem assembly and set on a protective surface.
For extension and bellows bonnet constructions, remove only the bonnet (key 4). For DN150 balanced constructions, remove the guide sleeve, bonnet, and valve plug stem assembly.
14
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Table 7. Packing Follower Torque
Valve Size Packing Style Torque NSm (lbfSft) Packing Style Torque NSm (lbfSft)
DN15, 20, 25, 40, and 50 ENVIRO-SEAL PTFE 10 (7.4) ENVIRO-SEAL ULF 35 (26)
DN80 and DN100 ENVIRO-SEAL PTFE 23 (17) ENVIRO-SEAL ULF 50 (37)
DN150 ENVIRO-SEAL PTFE 36 (26) ENVIRO-SEAL ULF 68 (50)
10. Remove the valve/yoke gasket (figures 18, 19, 20, and 21 key 5, figures 22 and 23 key 47) and cover the opening of the valve to protect the gasket surface and prevent foreign matter from getting into the valve cavity.
11. Remove the packing follower (key 29) from the bonnet (key 4).
12. Remove the Belleville spring pack (key 34) and packing spacer (key 30) from the bonnet (key 4). Carefully push out the remaining packing box parts from the bonnet (key 4) using a rounded rod or other tool which will not scratch the packing box wall. Clean the packing box and the metal packing box parts.
CAUTION
Inspect the valve stem, threads and packing box surfaces for any sharp edges that might cut the packing. Scratches or burrs could cause packing box leakage or damage the new packing.
13. Inspect the valve stem, threads and packing box surfaces for any sharp edges that might cut the packing. Scratches or burrs could cause packing box leakage or damage the new packing. If the surface condition cannot be improved by light sanding, replace the damaged parts.
14. Remove the covering protecting the valve cavity and install a new valve/yoke gasket (figures 18, 19, 20, and 21 key 5, figures 22 and 23 key 47) making sure that the gasket seating surfaces are clean and smooth. For DN150 balanced constructions, two gaskets are required; one between the valve body and guide sleeve, and the other between the guide sleeve and bonnet. Ensure the gasket seating surfaces are clean and smooth for both gaskets.
15. Carefully install the bonnet (key 4) onto the valve stem.
16. Install the new packing and the metal packing box parts according to figure 15 for ENVIRO-SEAL PTFE packing and according to figure 16 for ENVIRO-SEAL graphite ULF packing. Place a smooth‐edged pipe over the valve stem and gently tap each soft packing part into the packing box. Apply anti‐seize lubricant to the threads and install the packing follower (key 29).
17. Install the locknut (key 28) and stem adjustor nut (key 27). For standard bonnet constructions, install the valve plug/bonnet sub assembly into the valve body (key 1).
18. Mount the actuator onto the valve and install the body nuts (figures 18, 19, 20, 21 key 7, figures 22 and 23 key 46), but tighten them only finger‐tight.
19. For air‐to‐open, connect a separate air supply to the lower diaphragm casing air supply connection (as shown in figure 18 or 19) and apply sufficient air pressure to raise the actuator rod (key 22) to the travel stop. Proceed to the next step. For air‐to‐close, proceed to the next step.
20. For standard bonnet constructions, tighten the body nuts (key 7) evenly using a cross‐tightening procedure. See table 4 for torque requirements. For extension and bellows bonnet constructions, tighten the bonnet nuts (key 46) evenly using a cross‐tightening procedure. See table 5 for torque requirements.
21. Thread the stem lock adjustor (key 27) up until it is the rated travel distance specified in table 3 from the actuator rod (key 22). Thread the locknut (key 28) up against the stem locknut and tighten to the torque specified in table 6.
22. Stroke the actuator rod until it contacts the stem adjuster nut (key 27) and install the stem connector halves and travel indicator (keys 23, 24, and 26) with the cap screws (key 25). Install the stem connector halves in the proper orientation so that when looking at the inside of the stem connector halves, the flats are down and the beveled surfaces are up.
15
GX Valve and Actuator
July 2018
Instruction Manual
23. Align the pointer of the travel indicator (key 26) with the appropriate mark on the travel scale.
24. Tighten the stem connector cap screws (key 25) to 35 Nm (26 lbf•ft).
Table 8. Seat Ring / Cage Torque Requirements
VALVE SIZE TORQUE
DN NPS NSm lbfSft
15, 20, 25 1/2, 3/4, 1 170 124
40 1‐1/2 320 234
50 2 460 337
80 3 1020 747
100 4 1520 1113
150 6 3400 2500
Table 9. Stem Extension Torque Requirements
VALVE SIZE TORQUE
DN NPS Nm Lbfft
15, 20, 25, 40, 50 1/2, 3/4, 1, 1‐1/2, 2 40 30
80, 100 3, 4 120 89
Table 10. Bellows Nut Torque Requirements
VALVE SIZE TORQUE
DN NPS Nm Lbfft
15, 20, 25, 40, 50 1/2, 3/4, 1, 1‐1/2, 2 350 260
80, 100 3, 4 650 480
D103175X012
25. Tighten the packing follower (key 29) to the torque specified in table 7.
Alternately, the packing follower can be tightened by the following method:
a. Tighten the packing follower until the Belleville springs are compressed 100% (or completely flat), as detected by
a rapid increase in nut torque.
b. For DN15 through DN100 (NPS 1/2 through 4), loosen the packing follower 60_ of rotation.
For DN150 (NPS 6), loosen the packing follower 90_ of rotation.
26. For air‐to‐open, release the actuator pressure.
27. For air‐to‐open, ensure the vent (key 21) is installed into the upper diaphragm casing (see figure 18 or 19). For air‐to‐close, ensure the vent (key 21) is installed into the actuator yoke air supply connection (see figure 20 or
21).
Replacing Packing (Electric Actuators)
This section provides instruction on replacing packing in standard bonnets, extension bonnets, and bellows extension bonnets.
Isolate the control valve from the line pressure, release pressure from both sides of the valve body and drain the process media from both sides of the valve. Use lock‐out procedures to ensure that the above measures stay in effect while you work on the equipment.
1. Stroke the actuator so the valve plug/stem (key 3) is at mid travel.
2. Remove the stem connector nut half (key 23), stem connector bolt half (key 24), and travel indicator (key 26).
3. Use precaution to ensure the actuator is locked in position and cannot stroke.
16
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
4. Mark the position of the locknut (key 28) on the stem for reassembly.
5. Push the valve plug/stem (key 3) down until it contacts the seat.
6. Loosen the locknut (key 28) and thread the stem adjustor nut (key 27) down until it clears the top of the valve plug stem (key 3).
WARNING
To avoid personal injury or property damage by uncontrolled movement of the actuator yoke (key 8), loosen the body/yoke nuts (figures 18, 19, 20, and 21, key 7) or bonnet/yoke nuts (figures 22 and 23, key 46) by following the instructions in the following step 7. below. Do not remove a stuck actuator yoke by pulling on it with equipment that can stretch or store energy in any other manner. The sudden release of stored energy can cause uncontrolled movement of the actuator yoke.
Note
The following step also provides additional assurance that the valve body fluid pressure has been relieved.
7. For standard bonnet constructions (figures 18, 19, 20, and 21), body nuts (key 7) attach the actuator yoke (key 8) to the valve body (key 1). Loosen these nuts approximately 3mm (1/8 inch).
For extension and bellows bonnet constructions, bonnet nuts (key 46) attach the actuator yoke (key 8) to the extension bonnet (key 39). Loosen these nuts approximately 3mm (1/8 inch).
8. Then loosen the valve‐to‐yoke gasketed joint by either rocking the actuator yoke or prying between the valve and actuator yoke. Work the prying tool around the actuator yoke until it loosens.
WARNING
If there is evidence of process fluid under pressure leaking from the joint, retighten the valve body/joint nuts and return to the Warning at the beginning of the Maintenance section to ensure proper steps have been taken to isolate the valve and relieve process pressure, thus avoiding property damage or personal injury.
9. If no fluid leaks from the joint, loosen the packing follower (key 29) two turns to relieve the packing compression load.
10. For standard bonnet constructions (figures 18, 19, 20, and 21), remove the body nuts (key 7) completely. For extension and bellows bonnet constructions (figures 22 and 23), remove the bonnet nuts (key 46) completely.
CAUTION
To avoid property damage, place the actuator yoke on a protective surface, as described in the following procedure.
11. Carefully lift off the actuator yoke and set it on a protective surface to prevent damage. For standard bonnet constructions, if the bonnet (key 4) together with the valve stem plug assembly has a tendency to lift with the actuator yoke, ensure it does not drop from the actuator. For extension and bellows constructions, ensure the bonnet (key 4) does not lift with the actuator yoke.
CAUTION
For extension and bellows bonnet constructions, lifting the bonnet with the actuator yoke may cause possible damage to the valve plug and to the bellows.
17
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
12. Remove the stem adjustor nut (key 27) and locknut (key 28).
13. For standard bonnet constructions, remove the bonnet and the valve plug/stem assembly and set on a protective surface. For extension and bellows bonnet constructions, remove only the bonnet (key 4).
14. Remove the valve/yoke gasket (figures 18, 19, 20, and 21 key 5, figures 22 and 23 key 47) and cover the opening of the valve to protect the gasket surface and prevent foreign matter from getting into the valve cavity.
15. Remove the packing follower (key 29) from the bonnet (key 4).
16. Remove the Belleville spring pack (key 34) and packing spacer (key 30) from the bonnet (key 4). Carefully push out the remaining packing box parts from the bonnet (key 4) using a rounded rod or other tool which will not scratch the packing box wall. Clean the packing box and the metal packing box parts.
Table 11. GX Electric Actuator Maximum Allowable Thrust
VALVE SIZE
DN25 to DN50
(NPS 1 to 2)
DN80 to DN100
(NPS 3 to 4)
1. High strength stem materials consist of S200910, N05500, S31603.
2. Low strength materials consist of S31803, N10675, N06022.
STEM DIAMETER TRAVEL
mm mm N lbf
10 20
14 20, 40
BONNET STYLE
Plain
Bellows/Extension
Plain
Bellows/Extension
STEM MATERIAL
STRENGTH
(1)
High
(2)
Low
(1)
High
(2)
Low
(1)
High
(2)
Low
(1)
High
(2)
Low
MAXIMUM THRUST
17000 3820
7600 1710
11400 2560
6700 1500 20000 4500 20000 4500 20000 4500 14500 3260
CAUTION
Inspect the valve stem, threads and packing box surfaces for any sharp edges that might cut the packing. Scratches or burrs could cause packing box leakage or damage the new packing.
17. Inspect the valve stem, threads and packing box surfaces for any sharp edges that might cut the packing. Scratches or burrs could cause packing box leakage or damage the new packing. If the surface condition cannot be improved by light sanding, replace the damaged parts.
18. Remove the covering protecting the valve cavity and install a new valve/yoke gasket (figures 18, 19, 20, and 21 key 5, figures 22 and 23 key 47) making sure that the gasket seating surfaces are clean and smooth.
19. Carefully install the bonnet (key 4) onto the valve stem.
20. Install the new packing and the metal packing box parts according to figure 15 for ENVIRO-SEAL PTFE packing and according to figure 16 for ENVIRO-SEAL graphite ULF packing. Place a smooth‐edged pipe over the valve stem and gently tap each soft packing part into the packing box. Apply anti‐seize lubricant to the threads and install the packing follower (key 29).
21. Install the locknut (key 28) and stem adjustor nut (key 27). Ensure they are aligned with the mark made on the stem disassembly and tighten For standard bonnet constructions, install the valve plug/bonnet sub assembly into the valve body (key 1).
22. Mount the actuator onto the valve and install the body nuts (figures 18, 19, 20, 21 key 7, figures 22 and 23 key 46), but tighten them only finger‐tight.
23. For standard bonnet constructions, tighten the body nuts (key 7) evenly using a cross‐tightening procedure. See table 4 for torque requirements. For extension and bellows bonnet constructions, tighten the bonnet nuts (key 46) evenly using a cross‐tightening procedure. See table 5 for torque requirements.
18
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
24. Push the valve plug/stem to the valve seat. Thread the stem adjustor nut (key 27) and locknut (key 28) to the previously marked position. Thread the locknut (key 28) up against the stem locknut and tighten to the torque specified in table 6.
25. Stroke the actuator rod until it contacts the stem adjuster nut (key 27) and install the stem connector halves and travel indicator (keys 23, 24, and 26) with the cap screws (key 25). Install the stem connector halves in the proper orientation so that when looking at the inside of the stem connector halves, the flats are down and the beveled surfaces are up.
26. Align the pointer of the travel indicator (key 26) with the appropriate mark on the travel scale.
27. Tighten the stem connector cap screws (key 25) to 35 Nm (26 lbf•ft).
28. Tighten the packing follower (key 29) to the torque specified in table 7.
Alternately, the packing follower can be tightened by the following method:
a. Tighten the packing follower until the Belleville springs are compressed 100% (or completely flat), as detected by
a rapid increase in nut torque.
b. For DN15 through DN100 (NPS 1/2 through 4), loosen the packing follower 60_ of rotation.
CAUTION
Ensure that the electric actuator maximum thrust output does not exceed the values in table 11. The up travel stop must be set in the electric actuator in order to prevent damage to the valve trim.
Valve Trim Maintenance
Key numbers in this section refer to figures 18, 19, 20, 21, 22, and 23.
Valve Trim Disassembly
1. Remove the actuator and bonnet assembly as described in the Replacing Packing section (steps 1 through 10).
DFor standard bonnet constructions (figures 18, 19, 20, 21, and 25), proceed to the Seat Ring / Cage Removal section.
D For extension bonnet constructions (figure 22), proceed to step 3.
D For bellows bonnet constructions (figure 23), proceed to step 2.
2. For bellows bonnet constructions (figure 23), use a bellows nut tool made according to the dimensions in figure 26
and table 13 to remove the bellows nut (key 51) as follows:
a. Insert the bellows nut tool into the extension bonnet (key 39). Be certain the tool lugs are engaged in the
corresponding recesses in the bellows nut.
b. Use a torque gun or driver having sufficient torque capabilities according to table 10. Connect the gun to a
socket that snugly fits the hex head on the bellows nut tool.
c. Insert the socket onto the hex head of the bellows nut tool.
WARNING
Be careful to hold the torque gun, attached socket, and tool at right angles to the bellows nut when applying torque. Tilting the gun and socket while applying torque may cause the lugs on the bellows nut tool to suddenly disengage from the lugs on the bellows nut thus causing possible damage to the bellows nut and possible personal injury.
19
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
d. Remove the bellows nut (key 51).
3. For both extension and bellows bonnet constructions: Body nuts (key 7) attach the extension bonnet (key 39) to the
valve body (key 1). Loosen these nuts approximately 3mm (1/8 inch). Then loosen the extension bonnet‐to‐body gasketed joint by either rocking the extension bonnet or prying between the body and extension bonnet. Work the prying tool around the extension bonnet until it loosens.
4. Remove the body nuts (key 7) completely and carefully lift the extension bonnet (key 39), and valve plug/stem extension assembly (key 3, 40 and 48) or plug/bellows/stem extension assembly (key 3, 49 and 48) from the top of the valve body.
5. Use a wrench to unscrew the plug/stem assembly (key 3) from the stem extension (key 40) or from bellows/stem assembly (key 49) as follows:
a. Insert the wrench onto the stem extension hex flats (see figures 22 and 23).
CAUTION
In the following procedure, take precautions to ensure the valve plug and stem finish are not damaged.
b. Clamp the plug/stem assembly (key 3) and holding it stable, unscrew the stem extension (key 40) or
bellows/stem assembly (key 49). Take precautions to ensure the valve plug and stem finish are not damaged.
Note
There is a stem assembly locking insert (figures 22 and 23, key 48) in the valve plug/stem extension assembly. It is possible this insert may drop out during stem disassembly. If this is the case, ensure it is retained for reassembly of the valve stem to the stem extension.
6. Remove the plug/stem assembly (key 3) and bellows/stem assembly (key 49) from the extension bonnet. Remove the bellows gasket (key 50).
7. Proceed to the Seat Ring Removal section.
Seat Ring / Cage Removal
CAUTION
Use care to avoid damaging the gasket sealing surfaces. The surface finish of the valve stem (key 3) is critical for making a good packing seal. The seating surfaces of the seat ring
(key 2), cage (key 99), and the valve plug (key 3) are critical for tight shutoff and should therefore also be treated with care and properly protected.
1. Packing parts can be removed from the bonnet if desired. Replace these parts as described in the section on Packing Maintenance.
2. Use a seat ring tool made according to the dimensions in figure 5 and table 12 to remove the seat ring (key 2) as follows:
a. Insert the tool into the valve body. Be certain the tool lugs are engaged in the corresponding recesses in the seat
ring.
20
Instruction Manual
D103175X012
Figure 5. Seat Ring Removal and Installation Tool
GX Valve and Actuator
July 2018
A
A
G
B
H
DF
CC
DN15, 20, 25
(NPS 1/2, 3/4, 1)
GE02918‐6
E
D
DN40, 50, 80, 100
(NPS 1‐1/2, 2, 3, 4)
A
B
B
E
K
E
F
C
D
F
J
C
C
H
D
DN150
(NPS 6)
GG01215
OG
OF
C
DN25 Cav III
(NPS 1)
A
B
E
Table 12. Seat Ring Removal and Installation Tool Dimensions
Valve Size
DN NPS mm
Part Number
15, 20, 25 1/2, 3/4, 1 GE02918X012 24 15 15.2 9 54 40 45 10 ‐ ‐ ‐ ‐ ‐ ‐
25 (Cavitrol III) 1 (Cavitrol III) Not Available 24 18 13 6 30 39 45 10 ‐ ‐ ‐ ‐ ‐ ‐
40
50
(1)
(1)
1‐1/2
2
(1)
(1)
GE02918X022 36 20 2X 13.2 7.5 58 53 ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
GE02918X032 46 28 2X 13.2 7.5 63 63 ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
80 3 GE02918X042 60 36 2X 15.2 8.5 100 93 ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
100 4 GE02918X052 70 44 2X 17.2 9.5 114 113 ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
150 6 GE02918X062 100 50 2X 43 10.5 170.5 174 ‐ ‐ ‐ ‐ ‐ ‐ 153 20
1. Also used for Cavitrol III cage removal.
A B C D E
FO GO
H
JO
b. Use a torque gun or driver having sufficient torque capabilities according to table 8. Connect the gun to a socket
that snugly fits the hex head on the seat ring tool.
c. Insert the socket onto the hex head of the seat ring tool.
K
21
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
WARNING
Be careful to hold the torque gun, attached socket, and tool at right angles to the seat ring when applying torque. Tilting the gun and socket while applying torque may cause the lugs on the seat ring tool to suddenly disengage from the lugs on the seat ring thus causing possible damage to the seat ring and possible personal injury.
3. Remove the seat ring (key 2) from the valve body.
4. Inspect parts for wear or damage that would prevent proper operation of the valve body.
5. Replace trim parts as necessary.
Valve Trim Assembly
Assembly of Unbalanced Trim
Refer to figures 12, 18, 19, 20, 21, 22, 23, and 25.
1. Before installing the new seat ring / cage, thoroughly clean the threads in the valve body port. Apply suitable lubricant to the threads and to the 60° surface of the new seat ring (key 4). Screw the seat ring into the valve body. Using the seat ring tool, tighten the seat ring and torque according to the values in table 8. Remove all excess lubricant after tightening.
2. For standard bonnet constructions, perform the following. (Proceed to step 3 for extension and bellows bonnets.)
a. Clean the body/yoke gasket seating surfaces and install a new body/yoke gasket (key 5).
b. Remove any protective tape or covering from the valve plug/stem assembly.
c. Insert the valve plug/stem assembly into the seat ring.
CAUTION
If the packing is to be reused and was not removed from the bonnet, perform the following step carefully to avoid damaging the packing with the stem threads.
d. Install bonnet and actuator yoke onto the valve body by completing the assembly according to steps 15 to 27 of
the section Replacing Packing, omitting step 16 if new packing is not being installed.
3. For extension and bellows bonnet constructions, perform the following.
a. For bellows bonnet constructions, clean the extension bonnet/bellows gasket seating surfaces and install a new
bellows gasket (key 50).
b. Remove any protective tape or covering from the valve plug/stem assembly (key 3). Then insert the plug/stem
assembly (key 3) through the extension bonnet bushing (key 41).
c. Remove any protective tape or covering from the stem extension (key 40) or the bellows stem assembly (key 49).
Screw the plug/stem assembly (key 3) into the stem extension or bellows/stem assembly. Note: Do not apply
lubricant to the threads of the plug/stem assembly (key 3) or the bellows/stem assembly (key 49).
Note
Ensure the stem assembly locking insert (figures 22 and 23, key 48) has been first inserted in the bottom of the threaded hole in the stem extension.
22
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
CAUTION
In the following procedure, take precautions to ensure the valve plug and stem finish are not damaged.
d. Clamp the plug/stem assembly (key 3) and hold it stable. Using a box spanner tool tighten the plug/stem
assembly (key 3) into the stem extension (key 40) or into the bellows/stem assembly (key 49) according to the stem extension torque requirements listed in table 9. Take precautions to ensure the valve plug and stem finish are not damaged.
e. For bellows bonnet constructions, if using a N10276/PTFE bellows gasket install PTFE washer (key 120) on top of
the bellows flange. Apply suitable lubricant to the threads and to the bottom surface of the bellows nut (key 51). Screw the bellows nut into the extension bonnet. Using the bellows nut tool, a lathe or boring mill, tighten the bellows nut or torque according to the values in table 10. Remove all excess lubricant.
f. Clean the body/extension bonnet seating gasket surface and install the gasket (key 5).
g. Install the extension bonnet and plug/stem assembly onto the valve body. Install the body/yoke nuts (key 7) and
tighten evenly using a cross‐tightening procedure. See table 4 for torque requirements.
CAUTION
If the packing is to be reused and was not removed from the bonnet, perform the following step carefully to avoid damaging the packing with the stem threads.
h. Install the bonnet and actuator yoke onto the extension bonnet by completing the assembly according to steps
15 to 27 of the section Replacing Packing, omitting step 16 if new packing is not being installed.
Assembly of Balanced Trim
(Available in DN80, 100, and 150 [NPS 3, 4, and 6] only)
Refer to figure 10.
CAUTION
To protect the valve plug seal ring (key 37) and to ensure it seals properly, be careful not to scratch the surfaces of the ring groove in the valve plug or any of the surfaces of the replacement ring.
1. With the valve plug (key 3) removed according to the Disassembly portion of the Valve Trim Maintenance procedure, proceed as appropriate:
The seal ring (key 37) cannot be reused because it is a closed ring which must be pried and/or cut from the groove. Once the seal ring is removed, the elastomeric backup ring (key 38), which is also a closed ring, can be pried from the groove.
To install a new backup ring and seal ring onto the valve plug, apply a general purpose silicone‐base lubricant to both rings (keys 38 and 37). Place the backup ring over the valve plug (key 3) and into the groove. Place the seal ring over
23
GX Valve and Actuator
July 2018
the top edge of the valve plug (key 3) so that it enters the groove on one side of the valve plug. Slowly and gently stretch the seal ring and work it over the top edge of the valve plug. The PTFE material in the seal ring must be permitted time to cold‐flow during the stretching procedure, so avoid jerking sharply on this ring. Stretching the seal ring over the valve plug may make it seem unduly loose when in the groove, but it will contract to its original size after insertion into the bonnet.
2. Install the seat ring, valve plug/stem, bonnet and actuator yoke into the valve body by completing the assembly according to steps 1 to 3 of the section Assembly of Unbalanced Trim.
Instruction Manual
D103175X012
Repair Nameplate
If required by the end‐user, an optional repair nameplate is available for recording changes made to the valve trim during maintenance (see figure 29). This nameplate can be ordered as a spare part, and is easily mounted to the actuator casing using a casing bolt. (Reference the Parts Ordering section of this manual.)
As shown in figure 29, the repair nameplate provides locations for maintenance personnel to record trim data, such as:
D Date of maintenance
D Trim material
D Port diameter
D Flow capacity (C
D Flow characteristic
D Actuator Action ATO/ATC
/ Kv)
v
Bellows Maintenance
This section provides instruction on the replacement of the bellows / stem assembly (see key 49 in figure 23).
1. Remove the actuator, bonnet assembly as described in the Replacing Packing section (steps 1 through 10).
2. Remove the plug/stem assemblies as described in the Valve Trim Disassembly section (steps 2 through 6).
3. To install the new bellows / stem assembly (key 49), perform the Valve Trim Assembly (step 3).
24
Instruction Manual
D103175X012
Figure 6. Fisher GX Handwheel Assembly
STUD AND NUT (4)
LOCKING SCREW
GX Valve and Actuator
July 2018
LOCKING
STUD AND NUT (4)
SCREW
GE11642‐1
AIR‐TO‐CLOSE, SPRING‐TO‐OPEN
Figure 7. Fisher GX Handwheel Orientation and Grease Zerk Location
GE05809‐E
APPLY LUBRICANT
GE05810‐E
AIR‐TO‐OPEN, SPRING‐TO‐CLOSE
AIR‐TO‐OPEN, SPRING‐TO‐CLOSE
AIR‐TO‐CLOSE, SPRING‐TO‐OPEN
25
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
Handwheel Operation
CAUTION
This handwheel is designed only for use with size 225 and 750 actuators with 20 mm travel. To avoid equipment damage, do not assemble this handwheel on size 750 actuators with 40 mm travel or size 1200 actuators.
Principle of Operation
The GX handwheel is designed to compress the actuator springs and override the actuator fail action. Turning the handwheel drives the screw, nut, and levers. The levers push against the stem connector to transfer this motion. Reversing the direction of the handwheel will move the nut and levers in the opposite direction. Once the levers are no longer in contact with the stem connector, the locking screw should be used to secure the handwheel against undesired movement. To prevent damage due to overtravel, the handwheel should not be turned more than 2 full turns past the point at which the levers no longer contact the stem connector.
WARNING
To avoid personal injury or loss of process control due to equipment damage, ensure the levers are completely disengaged and the locking screw is tight while the valve is in normal pneumatic operation.
During normal pneumatic operation when the handwheel is not needed, a locking screw (see figure 6) is provided on the side of the handwheel housing to lock the handwheel levers out of the way.
WARNING
To avoid personal injury or equipment damage due to possible sudden shifting or falling of the valve assembly, do not lift the valve assembly by the handwheel.
GX Handwheel Installation (for use with 20mm travel only)
1. Note the orientation of the levers to the stem connector for either the air‐to‐close, spring‐to‐open configuration or for the air‐to‐open, spring‐to‐close configuration, as shown in figure 7.
2. Adjust the handwheel to allow positioning the levers above the stem connector before installation.
3. Install the handwheel to the GX mounting pad with four studs and nuts, as shown in figure 6. Torque to 24 NSm (18 lbfSft).
4. Apply lithium grease to the grease zerk and to the tip of the levers (where they contact the stem connector), as shown in figure 7.
26
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Travel Stop Operation
Principle of Operation
CAUTION
This travel stop is designed only for use with size 225 and 750 actuators with 20 mm travel. To avoid equipment damage, do not assemble this travel stop on size 750 actuators with 40 mm travel or size 1200 actuators.
The GX travel stop is designed to mechanically limit and stop the valve at a preset position in an emergency or upon loss of instrument air. This assembly is mounted on the yoke with four studs. The lever pushes against the stem connector to stop the travel. Travel position can be adjusted by two adjustable cap screws on the lever, as shown in figure 8. A cover plate assembly is available to prevent pinch point damage caused by the lever, as shown in figure 8.
WARNING
To avoid personal injury or equipment damage due to possible sudden shifting or falling of the valve assembly, do not lift the valve assembly by the travel stop.
To avoid personal injury or loss of process control due to equipment damage, screw the adjustable cap screws to ensure the lever is completely disengaged while the valve is in normal pneumatic operation.
Figure 8. Fisher GX Travel Stop Assembly
ADJUSTABLE
COVER PLATE
CAP SCREW (4)
LEVER
STUD AND NUT (4)
CAP SCREW (2)
COVER PLATE
CAP SCREW (4)
STUD AND NUT (4)
LEVER
ADJUSTABLE CAP SCREW (2)
DOWNSTOP
UPSTOP
27
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
GX Travel Stop Installation
Downstop
1. Note the orientation of the lever to the stem connector for downstop positioning, as shown in figure 9. Adjust the travel stop to allow positioning the lever below the stem connector before installation.
2. Install the travel stop to the GX mounting pad with four studs and nuts, as shown in figure 8. Torque to 24.5 NSm (18 lbfSft).
3. Apply lithium grease to the tip of the lever (where it contacts the stem connector) and to the two adjustable cap screws, as shown in figure 9.
Upstop
1. Note the orientation of the lever to the stem connector for upstop positioning, as shown in figure 9. Adjust the travel stop to allow positioning the lever above the stem connector before installation.
2. Install the travel stop to the GX mounting pad with four studs and nuts, as shown in figure 8. Torque to 24.5 NSm (18 lbfSft).
3. Apply lithium grease to the tip of the lever (where it contacts the stem connector) and to the two adjustable cap screws, as shown in figure 9.
Figure 9. Fisher GX Travel Stop Orientation
ACTUATOR ROD
STEM CONNECTOR
APPLY LITHIUM GREASE TO LEVERS
DOWNSTOP
BRACKET
LEVER
BACK NUT (2)
RETAINING RING
SHAFT
APPLY LITHIUM GREASE TO LEVERS
ADJUSTABLE CAP SCREW (2)
STEM CONNECTOR
UPSTOP
ACTUATOR ROD
LEVER
SHAFT
RETAINING RING
ADJUSTABLE CAP SCREW (2)
BACK NUT (2)
BRACKET
Setting the Travel Stop Position
After sending the required position air signal to the actuator, screw the adjustable cap screws to assure the lever contacts with the stem connector tightly, then tighten the back nut. Check the actual stem position when giving the 100% air signal.
Standard Accuracy for the travel stop position is +/- 10% for 20 mm travel. For added precision, use the following procedure.
1. Send the desired position air signal to the actuator.
28
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
2. Set the travel stop, screw the adjustable cap screws to assure the lever contacts with the stem connector tightly, then tighten the back nut.
3. Send a 100% air signal.
4. Measure the difference between the actual stem position and the desired position.
5. Send the air signal for the desired position minus the differential position measured in step 4.
6. Reset the travel stop by adjusting the two cap screws and then tighten the back nut.
Figure 10. Fisher GX Balanced Trim (Standard for DN80 and DN100 [NPS 3 and 4])
APPLY LUBRICANT
GE07161‐D
Figure 11. Fisher GX Balanced Trim (DN150 [NPS 6])
GE17575‐C
APPLY LUBRICANT
29
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
Figure 12. Fisher GX Unbalanced Port‐Guided Trim (DN40 to DN150 [NPS 1‐1/2 to 6])
GE03755_8
Figure 13. Fisher GX Whisper Trim™ III (DN150 [NPS 6])
Figure 14. Fisher GX Control Valve with Typical Soft Seat Trim Construction (Port Sizes of 36mm ‐ 136mm)
2
3
W9023‐1
Figure 15. Fisher GX ENVIRO-SEAL PTFE Packing DN5 through DN150 (NPS 1/2 through 6)
30
GE23496‐A
APPLY LUBRICANT
GE03755_14
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Figure 16. Fisher GX ENVIRO-SEAL Graphite ULF Packing DN15 through DN100 (NPS 1/2 through 4)
43
44
42 43
GE11961_C
Figure 17. Fisher GX ENVIRO-SEAL Graphite ULF Packing DN150 Only (NPS 6 Only)
44
GE03755_23
43
42
43
31
GX Valve and Actuator
July 2018
Instruction Manual
Figure 18. Fisher GX Control Valve and Actuator System Assembly, Air‐to‐Open (Spring‐to‐Close) (DN25 (NPS 1) with Unbalanced Contoured Plug)
AIR SUPPLY CONNECTION
D103175X012
32
GE02171‐H
APPLY LUBRICANT
Instruction Manual
D103175X012
GX Valve and Actuator
Figure 19. Fisher GX Control Valve and Actuator System Assembly, Air‐to‐Open (Spring‐to‐Close) (DN150 (NPS 6) with Unbalanced Contoured Plug)
July 2018
AIR SUPPLY CONNECTION
GE17517‐F
APPLY LUBRICANT
33
GX Valve and Actuator
July 2018
Instruction Manual
Figure 20. Fisher GX Control Valve and Actuator System Assembly, Air‐to‐Close (Spring‐to‐Open) (DN25 (NPS 1) with Unbalanced Contoured Plug)
AIR SUPPLY CONNECTION
D103175X012
34
APPLY LUBRICANT
GE03515‐H
Instruction Manual
D103175X012
GX Valve and Actuator
Figure 21. Fisher GX Control Valve and Actuator System Assembly, Air‐to‐Close (Spring‐to‐Open) (DN150 (NPS 6) with Unbalanced Contoured Plug)
AIR SUPPLY CONNECTION
July 2018
GE23239‐D
APPLY LUBRICANT
35
GX Valve and Actuator
July 2018
Figure 22. Extension Bonnet with ENVIRO-SEAL Graphite ULF Packing
Instruction Manual
D103175X012
GF00337‐D
STEM EXTENSION HEX FLATS
36
APPLY LUBRICANT
DO NOT APPLY LUBRICANT
Instruction Manual
D103175X012
Figure 23. Bellows Extension Bonnet with ENVIRO-SEAL PTFE Packing
GX Valve and Actuator
July 2018
GF00338‐F
APPLY LUBRICANT
DO NOT APPLY LUBRICANT
37
GX Valve and Actuator
July 2018
Figure 24. Cryogenic Extension Bonnet
APPLY LUBRICANT
GE23746‐A
Instruction Manual
D103175X012
Figure 25. Fisher Cavitrol III Trim, DN25, DN40, and DN50 (NPS 1, NPS 1-1/2, and NPS 2)
38
APPLY LUBRICANT
GG03061‐2
Instruction Manual
D103175X012
Figure 26. Bellows Nut Removal and Installation Tool
C HEX
GX Valve and Actuator
July 2018
C HEX
GF00536_3
D
F
E
H
G
6 mm
DN15, 20, 25, 40, and 50
(NPS 1/2, 3/4, 1, 1‐1/2, and 2)
D
B
A
F
E
B
A
8 mm
DN80 and 100
(NPS 3 and 4)
Table 13. Bellows Nut Removal and Installation Tool Dimensions
Valve Size A B C D E
DN NPS mm
15, 20, 25, 40, 50 1/2, 3/4, 1, 1‐1/2, 2 125 25 36 20 5 53 45 3
80, 100 3, 4 135 25 1.42 25 5 60 ‐ ‐ ‐ ‐ ‐ ‐
FO GO
H
39
GX Valve and Actuator
July 2018
Figure 27. Handwheel Assembly
Instruction Manual
D103175X012
40
GE05809_E
APPLY LUBRICANT
Instruction Manual
D103175X012
Figure 28. Fisher GX Electric Actuator Mounting
GX Valve and Actuator
July 2018
GG12175_A
Figure 29. Repair Nameplate (Spaces Provided for Recording Trim Maintenance Data)
TRIM MATERIAL
DATE OF MAINTENANCE
PORT DIAMETER
GE11233‐B
FLOW CHARACTERISTIC
FLOW CAPACITY
ACTUATOR ACTION
41
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
Parts Ordering
Each valve is assigned a serial number which can be found on the valve or on the nameplate (figure 2 and key 35, not shown). The nameplate will normally be fitted to the actuator. Refer to this serial number when contacting your
Emerson sales office
or Local Business Partner for technical assistance. When ordering replacement parts refer to this
serial number and give the part description from the following parts list.
WARNING
Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
Parts Kits
Valve Size
PACKING
KITS
ACTUATOR
BALANCED
SEAL KITS
1. A Gasket Kit is required when replacing the seals.
GASKET
KITS
ENVIRO-SEAL PTFE packing (Contains keys 32 and 33) RGXPACKX012 RGXPACKX022 RGXPACKX072
ENVIRO-SEAL Graphite ULF packing (Contains keys
KITS
(1)
Valve Size
Body / Bonnet Gasket Kit
(Graphite Laminate)
(Contains key 5)
Body / Bonnet Gasket and
Extension Bonnet Gasket Kit
(Graphite Laminate)
(Contains keys 5 and 47)
Body / Bonnet Gasket,
Extension Bonnet Gasket,
and Bellows Gasket
(Graphite Laminate)
(Contains keys 5, 47, and 50)
Stem Diameter
42, 43, and 44)
Actuator (Contains keys 10, 15, 19, 109, and 20) RGX225X0022 RGX750X0032 RGX1200X042
Ethylene Propylene (EPDM) (Contains keys 37 and 38) RGXSEALX032 RGXSEALX042 RGXSEALX082
FKM Fluorocarbon (Contains keys 37 and 38) RGXSEALX052 RGXSEALX062 RGXSEALX092
DN15 to DN50
(NPS 1/2 to 2)
10 mm
RGXPACKX052 RGXPACKX042 RGXPACKX082
Actuator Size 225 750 1200
Valve Size
Nitrile (Contains keys 37 and 38) RGXSEALX012 RGXSEALX022 RGXSEALX072
DN15 to DN25
(NPS 1/2 to 1)
GE00077X012 GE00078X012 GE00079X012 GE00080X012 GE00052X012 RGASKETXA62
RGASKETXA12 RGASKETXA22 RGASKETXA32 RGASKETXA42 RGASKETXA52 ‐ ‐ ‐
RGASKETXB12 RGASKETXB22 RGASKETXB32 RGASKETXB42 RGASKETXB52 ‐ ‐ ‐
DN 40
(NPS 1‐1/2)
DN 50
(NPS 2)
DN80 and DN100
(NPS 3 and 4)
DN80
(NPS 3)
DN 80
(NPS 3)
14 mm
DN100
(NPS 4)
DN 100 (NPS 4)
DN150 (NPS 6) 19 mm
DN150
(NPS 6)
DN 150 (NPS 6)
42
REPAIR NAMEPLATE
Description
18‐8 stainless steel nameplate. Will mount to all GX actuator sizes
using casing bolt. See figure 29.
DN15 to DN150
(NPS 1/2 to 6)
GE11233X012
Instruction Manual
D103175X012
GX Valve and Actuator
July 2018
Parts List
Note
Contact your Emerson sales office numbers.
Key Description
 1 Valve Body   2* Seat Ring  2* Cavitrol III Cage  3* Valve Plug/Stem  4 Bonnet  5* Body/Bonnet Gasket, graphite laminate see gasket kits table  6 Body/Bonnet Bolting (4 req'd)  7 Body/Bonnet Nut (4 req'd)  8 Actuator Yoke  9 Upper Diaphragm Casing 10* Diaphragm see actuator kits table 11 Diaphragm Plate 12 Actuator Springs 13 Actuator Spacer 14 Cap Screw 15 Washer see actuator kits table 16 Cap Screw, long
 Size 225 Actuator (2 req'd)  Size 750 Actuator (2 req'd)  Size 1200 Actuator (4 req'd)
17 Cap Screw, short
 Size 225 Actuator (4 req'd)  Size 750 Actuator (8 req'd)  Size 1200 Actuator (12 req'd)
18 Hex Nut
 Size 225 Actuator (6 req'd)  Size 750 Actuator (10 req'd)
 Size 1200 Actuator (16 req'd) 19* Actuator Rod Bushing see actuator kits table 20* Actuator Rod Seal see actuator kits table 21 Vent Cap 22 Actuator Rod 23 Stem Connector Nut Half 24 Stem Connector Bolt Half 25 Cap Screw (2 req'd) 26 Travel Indicator 27 Stem Adjustor Nut 28 Locknut 29 Packing Follower 30 Packing Spacer 31* Packing Box Ring 32* Anti‐Extrusion Washer (2 req'd) see packing kits table 33* ENVIRO-SEAL PTFE Packing Set see packing kits table 34 Belleville Spring (3 req'd)
or Local Business Partner for part
Key Description
35 Nameplate 36 Warning Tag 37* Seal Ring see balanced seal kits table 38* Backup Ring see balanced seal kits table 39 Extension Bonnet 40* Stem Extension 41* Extension Bonnet Lower Bushing 42* Graphite ULF Packing Ring (2 req'd) see packing kits table 43* Packing Ring (2 req'd) see packing kits table 44* Packing Washer (3 req'd) see packing kits table 45 Yoke/Extension Bonnet Bolting (4 req'd) 46 Yoke/Extension Bonnet Nut (4 req'd) 47* Extension Bonnet Gasket see gasket kits table 48* Insert (req'd for assembly of valve stem to extension stem) 49* Bellows/Stem Assembly 50* Bellows Gasket see gasket kits table 51 Bellows Nut 52 Pipe Plug 53 Handjack Body 54 Lever 55 Operating Nut 56 Drive Screw 57 Pivot Washer 58 Grooved Pin 59 Bearing 60 Pivot Pin 61 Bushing 62 Retainer Ring 63 Spacer 64 Cap Screw 65 Hex Nut 66 Lock Screw 67 Hex Nut 68 Stud 69 Hex Nut 70 Lubricant, Lithium Grease 71 Lubricant, Anti‐Seize 72 Cap Plug 73 Warning Tag 74 Travel Indicator Scale 75 Zerk Fitting 76 Handwheel 77 Locknut 78 Pipe Plug 79 Anti‐seize sealant 80 Lubricant, silicone sealant 81 Pipe Plug 82 Inner Actuator Spring 84 Guide Sleeve 84* Whisper III Cage 109* O-ring see actuator kits table 110 Rod Adaptor 111 Stud 112 Nut 113 Drive Screw 114 Electric Actuator Spacer 115 Lead Seal and Wire (not shown) 120 PTFE Washer
*Recommended spare parts See Parts Kits
43
GX Valve and Actuator
July 2018
Instruction Manual
D103175X012
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher, FIELDVUE, Cavitrol, ENVIRO-SEAL, and Whisper Trim are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore
www.Fisher.com
44
E 2003, 2018 Fisher Controls International LLC. All rights reserved.
Loading...