Fisher Fisher ENVIRO-SEAL Packing System for Rotary Valves Manuals & Guides

Instruction Manual
D101643X012
ENVIRO-SEAL System - Rotary Valves
Fisher™ ENVIRO‐SEAL™ Packing System for Rotary Valves
February 2019
Contents
Introduction 1.................................
Valve/Actuator Shaft Coupler 2..................
Description 2.................................
Installation 3..................................
Removing the Actuator 3.......................
Installing an ENVIRO‐SEAL Packing System 4.......
Other Considerations 11.......................
Parts Ordering 13...............................
Parts Kits 13...................................
Retrofit Kits 13................................
Repair Kits 16.................................
Figure 1. Typical ENVIRO‐SEAL Packing System
W5882-1
W9058‐1
ROTARY
BUTTERFLY
Introduction
Scope of Manual
This instruction manual includes installation and parts information for Fisher ENVIRO‐SEAL live‐loaded packing systems (see figure 1). These systems are available for Fisher rotary valves with 12.7 through 88.9 mm (1/2 through 3‐1/2 inch) shaft diameters. The system can be used with many rotary valves, as shown in tables 1 and 3. Refer to appropriate valve and actuator instruction manuals for necessary information relating to the disassembly and assembly of the valve and actuator. ENVIRO‐SEAL packing systems utilize a Belleville (coned‐disk) spring system.
Do not install, operate, or maintain the ENVIRO‐SEAL packing system, valve, actuator or accessories without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal
injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Emerson
sales office before proceeding.
www.Fisher.com
ENVIRO-SEAL System - Rotary Valves
February 2019
Table 1. Specifications
Instruction Manual
D101643X012
Applicable Valve Designs
Fisher 8510B (single arrangements only), 8560 and 8532 eccentric disk control valves; A11, A31A, A31D and A41 control valves; V150, V200 and V300 Vee‐Ballt control valves (Series B & Non‐Series B
(1)
); V250 and V260 and BV500, CV500 and V500 eccentric plug rotary valves. Also see table 3.
1. Refer to Fisher Vee‐Ball V150, V200 & V300 instruction manual, for distinctions between Series B & Non‐Series B.
2. The pressure/temperature limits in this manual, in the valve literature, and any applicable code or standard limitation should not be exceeded.
Applicable Shaft Diameters
See table 3
Pressures and Temperatures
See table 2
(2)
Table 2. Maximum Application Temperature and Pressure for 100 PPM Service
ENVIRO‐SEAL PACKING MATERIAL
Single PTFE 232 450 Not Restricted
Double PTFE
Graphite 316 600 Not Restricted
1. For pressure ratings through CL600 of valves listed in this instruction manual.
2. These application conditions apply for double PTFE only in the valve types where double PTFE is available.
(2)
MAXIMUM APPLICATION TEMPERATURE
_C _F
177 350
MAXIMUM APPLICATION
PRESSURE
(1)
20.7 bar (300 Psi)
(1)
Valve/Actuator Shaft Coupler
To install an ENVIRO‐SEAL packing system on an A11, A31A, A31D, or 8532 valve with a non‐standard, non‐Fisher produced actuator may require a special valve/actuator shaft coupler.
Table 10 contains a list of valve/actuator combinations and part numbers for the new coupler. If you are considering installation of an ENVIRO‐SEAL packing system in another existing valve/actuator package, check table 10 to see if a new coupler is required.
In some cases, coupler replacement is not required when retrofitting valve/actuator combinations. Table 11 contains a list of valve/actuator combinations that can use existing couplers.
Description
Fisher packing systems are offered with exceptional sealing capabilities that you can easily install in existing valves or that you can purchase with new valves. These systems help you conserve valuable process fluid. The external live‐loading provides a constant load over the life of the packing material, which reduces the need for packing box adjustment and maintenance.
The system design, coupled with very smooth shaft finishes and spring‐loading of the packing, provides longer service with lower maintenance than many other designs.
2
Instruction Manual
D101643X012
ENVIRO-SEAL System - Rotary Valves
February 2019
Installation
Use these instructions to install ENVIRO‐SEAL packing in valves that have standard packing, or when inspecting or replacing ENVIRO‐SEAL packing.
If you are changing the packing system material from standard graphite to ENVIRO‐SEAL graphite or ENVIRO‐SEAL PTFE packing, the packing friction for ENVIRO‐SEAL packing will be lower than it was for the standard packing. Therefore, no change should be needed in actuator sizing.
If you are changing the packing system material from standard PTFE to ENVIRO‐SEAL graphite or ENVIRO‐SEAL PTFE packing, the packing friction will increase. Contact your Emerson sales office be large enough.
WARNING
Always wear protective gloves, clothing and eyewear when performing any maintenance operations to avoid personal injury.
To avoid personal injury or property damage resulting from the sudden release of pressure, do not install the valve assembly where service conditions could exceed the limits given in this manual, the appropriate valve instruction manual, or the limits on the appropriate name plates. Use pressure relieving devices as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process media.
If installing into an existing application, also refer to the WARNING at the beginning of the Removing the Actuator section in this instruction manual.
to determine if your existing actuator will
Removing the Actuator
WARNING
Avoid personal injury from sudden release of process pressure or uncontrolled movement of parts. Before performing any maintenance operations:
D Do not remove the actuator from the valve while the valve is still pressurized.
D Always wear protective gloves, clothing and eyewear when performing any maintenance operations to avoid personal
injury.
D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure
on both sides of the valve. Drain the process media from both sides of the valve.
D Vent the power actuator loading pressure and relieve any actuator spring precompression.
D Use lock‐out procedures to be sure that the above measures stay in effect while you work on the equipment.
D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
3
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
You must remove the actuator from the valve when you install ENVIRO‐SEAL packing systems. To allow proper readjustment of the valve disk position, it is recommended that you remove the valve from the pipeline. Refer to appropriate valve and actuator instruction manuals.
WARNING
If a spring‐return actuator is used, be sure the actuator spring is resting on its travel stop. If something is obstructing shaft rotation, it is possible that disconnecting the shaft connector will allow the spring to force the actuator to the end of its rotation, resulting in possible personal injury or property damage. Refer to the appropriate valve and actuator instruction manuals to remove the actuator.
Installing an ENVIRO‐SEAL Packing System
Note
When installing an ENVIRO‐SEAL packing system into an insulated valve, do not cover the packing springs with insulation.
Note
The valve shaft surface condition is critical in obtaining a good seal. If the valve shaft surface is scratched, nicked, or worn, replace the valve shaft before installing the ENVIRO‐SEAL Packing System.
Refer to the appropriate valve instruction manual to replace the valve shaft.
Key number locations are shown in figures 2 and 4 for Vee‐Ball, eccentric plug, 8560, and A41 valves, and in figures 3 and 5 for A11, A31A, A31D and 8532 valves.
1. If you are installing an ENVIRO‐SEAL packing system in an existing valve, remove existing packing nuts, packing flange, jam nuts, anti‐blowout flange, packing follower, and any other external packing components from the valve body.
CAUTION
Because the valve shaft surface condition is critical in obtaining a good seal, caution must be used when removing existing internal packing parts. Do not scratch, nick or dent the valve shaft.
2. For A11, A31A, A31D and 8532 valves, remove the anti‐blowout wire that surrounds the valve shaft.
3. For all valves, remove packing and all other internal components from the packing box.
4. Inspect the existing valve shaft. If necessary, replace the valve shaft. Refer to the appropriate valve instruction manual to replace the valve shaft.
4
Instruction Manual
D101643X012
ENVIRO-SEAL System - Rotary Valves
February 2019
Figure 2. Typical ENVIRO‐SEAL Rotary Packing Arrangements with PTFE Packing for Fisher Vee‐Ball, Eccentric Plug, A41, and 8560 Valves
42B8445‐C
SINGLE PTFE PACKING
STANDARD DEPTH BOX
14B0095‐A
STACKING ORDER
PTFE PACKING RINGS
42B8445‐C
SINGLE PTFE PACKING
OPTIONAL DEEP PACKING BOX
V500
NOTES:
APPLY LUBRICANT
1
THESE TWO SURFACES MUST REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY TIGHTEN THE PACKING NUTS (KEY 101)
2
42B8445‐C
DOUBLE PTFE PACKING WITH LEAKOFF
OPTIONAL DEEP PACKING BOX
V500, CV500
42B8445‐C
SINGLE PTFE PACKING, OUTBOARD
STANDARD DEPTH BOX
8510B
Note
ENVIRO‐SEAL PTFE packing systems can be used in either vacuum or positive pressure service. It is not necessary to reverse ENVIRO‐SEAL PTFE packing components in vacuum service.
Make sure that the Belleville springs are stacked properly and packing box parts are assembled in the correct order (see figure 6). Packing parts cannot function properly if the Belleville springs or other packing parts are not stacked correctly.
5. With the shaft in place in the valve, install the packing parts into the valve packing box.
Note
Be sure to install the packing rings in the sequence shown in figures 2 through 5.
5
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
a. Place one of the packing box rings (key 107) into the packing box. Be sure the packing box ring is properly seated.
This does not apply to NPS 3, 4 and 6 CL600 A11 valves.
b. For PTFE packing, place an anti‐extrusion washer (key 106) into the packing box and push it in until it rests next
to the packing box ring (key 106 is not used with graphite packing).
Note
The graphite packing set has a carbon anti‐extrusion ring on the top and bottom of the packing. These anti‐extrusion rings are designed to have a slight interference fit on the shaft. The rings have a single fracture to allow the ring to be installed on the shaft. Additional fractures may develop while the valve is in service, however, these additional fractures will not affect the performance of the ENVIRO‐SEAL packing.
c. Place the packing set (key 105) into the packing box. Refer to figure 3 or 5 for the proper orientation of the
packing set.
d. For PTFE packing, place another anti‐extrusion washer (key 106) into the packing box after the packing set (key
106 is not used with graphite packing).
e. Place the second packing box ring (key 107) into the packing box.
f. Locate the new spring pack assembly (key 103). Remove the O‐ring and packing springs from the packing
follower. Use the packing follower to press the packing components into the packing box. Remove the packing follower.
6. For A11, A31A, A31D and 8532 valves, install the anti‐blowout wire (key 16) in the groove around the valve shaft.
7. Slide the packing follower from the new spring pack assembly over the valve shaft and the anti‐blowout wire until it rests against the packing box ring.
8. For all valves, install the longer packing studs (key 100).
9. For A11, A31A, A31D and 8532 valves, install the new anti‐blowout flange (key 10) over the valve shaft, packing studs, and packing follower. Secure the anti‐blowout flange with the new jam nuts (key 17).
10. For all valves, install the spring pack assembly (key 103 or 104) which includes the Belleville springs, packing
follower, and O‐ring arranged as shown in figures 2 through 6. (The O‐ring is a non‐functional part and is used to retain the packing springs during assembly.)
6
Instruction Manual
ENVIRO-SEAL System - Rotary Valves
D101643X012
Figure 3. ENVIRO‐SEAL PTFE Packing System for Fisher 8532, A11, A31A and A31D Valves
32B9116‐B
NOTES:
NOT USED ON VALVES LARGER THAN NPS 12
1
NOT USED ON A11
2
NOT USED ON A11 CL600, NPS 3, 4, AND 6
3
February 2019
14B0095‐A
3
STACKING ORDER OF PTFE PACKING RINGS
11. Install the packing flange (key 102) on the shaft, and install the packing nuts (key 101). Hand tighten them.
Note
In general, the following tightening procedure applies to all ENVIRO‐SEAL packing systems—both sliding‐stem and rotary.
CAUTION
Excessive force could cause valve body bushing displacement in Non‐Series B Vee‐Ball valves, allowing Vee‐Ball misalignment, excessive seat leakage, or stalling of the actuator.
Note
Lubrication is required for the packing studs and nuts. Although it is important to properly lubricate the stud threads and internal nut threads, it is also important to properly lubricate the contacting face of the nut. See figures 2 through 5 and 7 for lubrication locations.
7
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
Figure 4. Typical ENVIRO‐SEAL Rotary Packing Arrangements with Graphite Packing for Fisher Vee‐Ball, Eccentric Plug, A41, and 8560 Valves
2
42B8445-C/DOC
GRAPHITE PACKING
STANDARD DEPTH BOX
3
3
14B0086-A/DOC
STACKING ORDER
GRAPHITE PACKING RINGS
42B8445-C/DOC
GRAPHITE PACKING, OUT-
BOARD
STANDARD DEPTH BOX
8510B
NOTES:
APPLY LUBRICANT
1
THESE TWO SURFACES MUST REMAIN PARALLEL AS YOU ALTERNATELY AND
2
EVENLY TIGHTEN THE PACKING NUTS (KEY 101)
3
VALVE WITH SHAFTS LARGER THAN 38.1 mm (1-1/2 INCH) USE THREE GRAPHITE RINGS
1
2
2
42B8445-C/DOC
3
GRAPHITE PACKING
OPTIONAL DEEP PACKING BOX
V500
Note the following definitions. You will need them for the next few steps. The target load is the point where the Belleville springs are designed for optimum performance, when they are compressed to 85% of their maximum deflection, or nearly flat. Maximum deflection is when the springs are 100% compressed, or completely flat.
12. You will obtain maximum benefit from your ENVIRO‐SEAL packing system when you tighten the packing flange nuts and compress the Belleville springs to their “target load”.
To obtain the target load of 85% compression of maximum deflection, perform the following:
D Tighten the packing flange nuts alternately and evenly, keeping the packing flange parallel with the valve flange
(see figure 7), until the Belleville springs are compressed 100% (or completely flat).
8
Instruction Manual
D101643X012
ENVIRO-SEAL System - Rotary Valves
Figure 5. ENVIRO‐SEAL Graphite Packing System for Fisher 8532, A11, A31A and A31D Valves
14B0086‐A
STACKING ORDER OF
GRAPHITE PACKING RINGS
NOTES:
VALVES WITH SHAFTS LARGER THAN 38.1 mm (1-1/2 INCH) USE 3 GRAPHITE RINGS
1
NOT USED ON VALVES LARGER THAN NPS 12
2
NOT USED ON A11 VALVES
3
NOT USED ON A11 CL600 NPS 3, 4, AND 6
4
32B9116‐B
February 2019
4
CAUTION
Do not use pneumatic air tools. Do not apply torque in excess of 34 NSm (25 ftSlbs) increments to any one flange nut at a time. Excessive over‐torquing of the flange nuts may cause the studs to break.
D For PTFE packing, loosen each packing flange nut 1/2 turn (180_ of rotation).
D For graphite packing, loosen each packing flange nut 1/4 turn (90_ of rotation).
The “target load” of 85% compression has now been reached.
13. Install the actuator. Refer to the appropriate valve and actuator instruction manuals when connecting the valve to the actuator.
Under normal conditions, the packing nuts should not require re‐tightening.
However, when servicing, if the springs do not remain at the target load of 85% compression, retighten the packing box nuts according to step 11 above.
9
ENVIRO-SEAL System - Rotary Valves
February 2019
Figure 6. Belleville Spring Stacking Order
Instruction Manual
D101643X012
O-RING
BELLEVILLE SPRINGS (10)
PACKING FOLLOWER
GRAPHITE A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐ BALL VALVES: SIZE 12.7 & 15.9 (1/2 AND 5/8) SHAFT A11 and A31A: SIZE 14.3 (9/16) SHAFT
O-RING
BELLEVILLE SPRINGS (9)
O-RING
BELLEVILLE SPRINGS (6)
PACKING FOLLOWER
GRAPHITE A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐ BALL VALVES: SIZE 19.1 (3/4), 38.1 (1‐1/2), 44.5 (1‐3/4), 53.8 (2‐1/8), 63.5 (2‐1/2), 76.2 (3) AND 88.9 (3‐1/2) SHAFT A11: SIZE 19.2 - 88.9 (3/4 - 3‐1/2) SHAFT A31A: SIZE 17.5 - 31.8 (11/16 - 1‐1/4) SHAFT
O-RING
BELLEVILLE SPRINGS (7)
O-RING
BELLEVILLE SPRINGS (5)
PACKING FOLLOWER
PTFE A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐BALL VALVES: SIZE 12.7 AND 15.9 (1/2 AND 5/8) SHAFT A11 and A31A: SIZE 14.3 (9/16) SHAFT
B2410‐2
PACKING FOLLOWER
PTFE A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐BALL VALVES: SIZE 19.1 (3/4), 22.2 (7/8), AND 25.4 (1) SHAFT A11: SIZE 14.3 AND 19.1 (9/16 AND 3/4) SHAFT A31A: SIZE 17.5 AND 23.8 (11/16 AND 15/16) SHAFT
PACKING FOLLOWER
PTFE A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐BALL VALVES: SIZE 19.1 (3/4), 38.1 (1‐1/2), 44.5 (1‐3/4), 53.8 (2‐1/8), 63.5 (2‐1/2), 76.2 (3) AND 88.9 (3‐1/2) SHAFT A11: SIZE 28.5 - 88.9 (1-1/8 - 3‐1/2) SHAFT A31A: SIZE 28.5 - 63.5 (11/16 - 2‐1/2) SHAFT
mm (INCH)
10
Instruction Manual
D101643X012
Figure 7. ENVIRO‐SEAL PTFE Packing System Detail
32B9116‐B
NOTES:
1
APPLY LUBRICANT THESE TWO SURFACES MUST REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY TIGHTEN THE PACKING NUTS.
2
Other Considerations
ENVIRO-SEAL System - Rotary Valves
February 2019
Note
The following check is only valid for rotary ENVIRO‐SEAL packing systems and sliding‐stem ENVIRO‐SEAL or HIGH‐SEAL packing systems.
When retrofitting an existing packing system or repacking a valve with ENVIRO‐SEAL packing that has been in service, check the condition of the packing bore after you have removed the packing. An easy method for cleaning debris and minor imperfections from the bore is to use a brake cylinder hone attached to an electric drill. This method will do a good job of cleaning the packing bore without changing the dimension of the bore.
When you have completed this exercise, a good guideline to use in checking the condition of the packing bore is the 20/20 rule. If less than 20% of the surface area of the bore is pitted and if no pits are deeper than 0.020 inch, then your packing will work fine. This does not need to be an exact measurement; visual inspection is adequate. If the packing bore does not meet this criteria, however, you should replace the valve or have your Emerson service center repair it.
11
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
Table 3. Applicable Valve Sizes
NPS
2 3 4 6
8 10 12
14 16 18 20 24
14 16 18 20 24
2
3
4
6
8 10 12
2
3
4
6
8 10 12
1
1-1/2
2
3
4
6
8 10 12 14 16 20
1
1-1/2
2
3
4
6
8 10
1
1-1/2
2
3
4
6
8 10 12 14 16
(1)
PRESSURE
CLASS
See Bulletin
51.6:8560
150
300
150
300
150
150/300/
600
300
and Shaft Diameters
VALVE
8510B
8532
8560
V150
V200
V300
VALVE SIZE,
VALVE SHAFT DIAMETER
mm Inches
12.7
15.9
19.1
25.4
31.8
31.8
38.1
34.9
38.1
44.5
50.8
63.5
50.8
57.2
63.5
76.2
88.9
12.7
12.7
15.9
19.1
25.4
31.8
38.1
12.7
15.9
19.1
25.4
31.8
38.1
44.5
12.7
15.9
15.9
19.1
19.1
25.4
31.8
31.8
38.1
44.5 54
63.5
12.7
15.9
15.9
19.1
19.1
25.4
31.8
31.8
12.7
15.9
15.9
19.1
19.1
25.4
31.8
31.8
38.1
44.5 54
1/2 5/8 3/4
1 1‐1/4 1‐1/4 1‐1/2
1‐3/8 1‐1/2 1‐3/4
2 2‐1/2
2 2‐1/4 2‐1/2
3 3‐1/2
1/2 1/2 5/8 3/4
1 1‐1/4 1‐1/2
1/2 5/8 3/4
1 1‐1/4 1‐1/2 1‐3/4
1/2 5/8 5/8 3/4 3/4
1 1‐1/4 1‐1/4 1‐1/2 1‐3/4 2‐1/8 2‐1/2
1/2 5/8 5/8 3/4 3/4
1 1‐1/4 1‐1/4
1/2 5/8 5/8 3/4 3/4
1 1‐1/4 1‐1/4 1‐1/2 1‐3/4 2‐1/8
Table 3. Applicable Valve Sizes and Shaft Diameters (cont.)
VALVE
BV500
CV500
V500
A31A & A31D
A41
A11
1. Shaft Diameter through the packing box.
VALVE SIZE,
NPS
1
1-1/2
2 3 4 6
3 4 6
8 10 12
1
1-1/2
2
3
4
6
8 10
3
4
6
8 10 12 14 16 18 20 24
3
4
6
8 10 12 14 16 18 20 24
2
3
4
6
8 10 12
2
3
4
6
8 10 12
3
4
6
8 10 12 14 16 18
PRESSURE
CLASS
150/300
150/300/
600
150/300/
600
150
300
150
300
600
VALVE SHAFT DIAMETER
mm Inches
15.9
15.9
15.9
15.9
25.5
25.5
25.4
31.8
38.1
38.1
44.5
53.8
12.7
15.9
15.9
25.4
31.8
31.8
38.1
44.5
14.3
17.5
23.8
23.8
28.5
31.8
34.9
38.1
44.5
50.8
63.5
14.3
17.5
23.8
31.8
41.3
47.6
50.8
57.2
63.5
76.2
88.9
12.7
12.7
15.9
19.1
25.4
31.8
38.1
12.7
15.7
19.0
25.4
31.8
38.1
44.4
14.3
19.1
28.5
38.1
44.5
57.2
63.5
76.2
88.9
5/8 5/8 5/8 5/8
1 1
1 1‐1/4 1‐1/2 1‐1/2 1‐3/4 2‐1/8
1/2 5/8 5/8
1 1‐1/4 1‐1/2 1‐1/2 1‐3/4
9/16 11/16 15/16 15/16
1‐1/8 1‐1/4 1‐3/8 1‐1/2 1‐3/4
2
2‐1/2
9/16 11/16 15/16
1‐1/4 1‐5/8 1‐7/8
2 2‐1/4 2‐1/2
3 3‐1/2
1/2 1/2 5/8 3/4
1 1‐1/4 1‐1/2
1/2 5/8 3/4
1 1‐1/4 1‐1/2 1‐3/4
9/16
3/4 1‐1/8 1‐1/2 1‐3/4 2‐1/4 2‐1/2
3
3‐1/2
12
Instruction Manual
D101643X012
ENVIRO-SEAL System - Rotary Valves
February 2019
Parts Ordering
Each valve assembly is assigned a serial number that can be found on the valve body. Refer to the serial number when contacting your Emerson sales office
When ordering replacement parts, refer to the serial number and to the 11‐character kit number for each kit required from the following list. Kits for valves with shaft sizes greater than 38.4 mm (1‐1/2 inch) will not be available, however, ENVIRO‐SEAL parts may be ordered separately. Consult your Emerson sales office for details.
for technical assistance.
Parts Kits
Retrofit Kits
Retrofit kits include all parts required for installation of the ENVIRO‐SEAL packing system into existing rotary and high performance butterfly valves. Retrofit kits are available for single PTFE or graphite packing. See tables 5 through 7 for retrofit kit part numbers.
The 8510B has two packing boxes, one at the actuator end and one at the outboard end. Select a kit from each column of the following table.
Packing boxes in V500 and CV500 valve bodies may be deep drilled, (at one time standard on all CV500 and always available as an option). If the valve body being retrofitted has a deep packing box, use the longer packing box ring (key
107) from the original packing. Discard the 3 mm (1/8‐inch) packing box ring from the retrofit kit. If a replacement packing box ring (long, key 107) is required, refer to the valve instruction manual for parts, or consult your Emerson sales office. Refer to figure 2, the view titled: Double PTFE Packing with Leakoff—Optional Deep Packing Box.
Note
1. Use the existing long packing box ring (key 107) that was furnished with the original valve when installing the retrofit kit in:
•V200 NPS 8 and 10 valves, or
•V150 and V300 NPS 8, 10, and 12 valves
WARNING
Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
13
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
Table 4. Retrofit Kit Included Parts
Key Description Quantity
(5)
10
(5)
17
100
101 102 103
104 105 106
107 111 112
1.For use on Actuator end. The spring pack assembly is made up of the packing spring stack held in place by an O‐ring on the packing follower.
2. For use on Outboard end. The spring pack assembly is made up of the packing spring stack held in place by an O‐ring on the packing follower.
3. Not included in graphite packing kit.
4. Only 1 req'd for NPS 18 CL300, NPS 20 CL150 and NPS 24 CL150. Two packing box rings required for 8560, 44.5 mm (1‐3/4 inch) shaft. Not required on V150, V200 or V300 with 31.8 or 38.1 mm (1‐1/4 or 1‐1/2 inch) shafts.
5. These are included in retrofit kits for 8532, A11, A31A and A31D valves.
6. NPS 3 through 12 CL150 and NPS 3 through 8 CL300 for A31A, 8532 and A31D; NPS 3 through 6 CL600, A11.
7. NPS 14 through 24 CL150/300 for A31A, 8532 and A31D; NPS 8 through 18 CL600, A11.
Anti‐blowout follower
Jam nut
Packing stud
Packing nut
Packing flange
Spring pack assembly
Spring pack assembly
Packing Set
Anti‐extrusion washer
Packing box ring
Tag
Cable
(5)
(5)
(1)
(2)
1 1
(6)
(7)
or 4
2
(6)
(7)
2
or 4
1 1
1 1
(3)
2
(4)
2
1 1
Table 5. Retrofit Kits for Fisher Vee‐Ball, Eccentric Plug, 8560 and 8510B Valves with Spline Shafts
PTFE RETROFIT KITS
SHAFT DIAMETER, mm (INCH)
Actuator End
PACKING BOX END
Outboard End for
8510B Only
12.7 (1/2) RRTYXRT0012 RRTYXRT0082 RRTYXRT0312 RRTYXRT0382
15.9 (5/8) RRTYXRT0022 RRTYXRT0092 RRTYXRT0322 RRTYXRT0392
19.1 (3/4) RRTYXRT0032 RRTYXRT0102 RRTYXRT0332 RRTYXRT0402
25.4 (1) RRTYXRT0052 RRTYXRT0112 RRTYXRT0352 RRTYXRT0412
31.8 (1‐1/4) RRTYXRT0062 RRTYXRT0122 RRTYXRT0362 RRTYXRT0422
38.1 (1‐1/2)
 8560 NPS 10 (CL 300)
 8560 NPS 12 (CL 150)
44.5 (1‐3/4)
 8560 NPS 12 (CL 300)
 V500 NPS 10
RRTYXRT0072 RRTYXRT0672 RRTYXRT0672
RRTYXRT0682 RRTYXRT0692 RRTYXRT0702
RRTYXRT0132
‐ ‐ ‐ ‐ ‐ ‐
RRTYXRT0762
‐ ‐ ‐ ‐ ‐ ‐
RRTYXRT0372 RRTYXRT0812 RRTYXRT0812
RRTYXRT0822 RRTYXRT0832 RRTYXRT0842
54 (2‐1/8) RRTYXRT0722 ‐ ‐ ‐ RRTYXRT0862 ‐ ‐ ‐
63.5 (2‐1/2) RRTYXRT0732 RRTYXRT0782 RRTYXRT0872 RRTYXRT0922
GRAPHITE RETROFIT KITS
PACKING BOX END
Actuator End
Outboard End for
8510B Only
RRTYXRT0432
‐ ‐ ‐ ‐ ‐ ‐
RRTYXRT0902
‐ ‐ ‐ ‐ ‐ ‐
Table 6. Retrofit Kits for Fisher Vee‐Ball, Eccentric Plug, 8510B and A41 valves with Double D and Keyed End Connection
PTFE RETROFIT KITS PACKING BOX END GRAPHITE RETROFIT KITS PACKING BOX END
SHAFT DIAMETER, mm (INCH)
12.7 (1/2) RRTYXRT0972 RRTYXRT0082 RRTYXRT1072 RRTYXRT0382
15.9 (5/8) RRTYXRT0982 RRTYXRT0092 RRTYXRT1082 RRTYXRT0392
19.1 (3/4) RRTYXRT0992 RRTYXRT0102 RRTYXRT1092 RRTYXRT0402
25.4 (1) RRTYXRT1012 RRTYXRT0112 RRTYXRT1102 RRTYXRT0412
31.8 (1‐1/4) RRTYXRT1022 RRTYXRT0122 RRTYXRT1112 RRTYXRT0422
38.1 (1‐1/2)  RRTYXRT1032 RRTYXRT0132 RRTYXRT1122 RRTYXRT0432
44.5 (1‐3/4) RRTYXRT1042 RRTYXRT0762 RRTYXRT1132 RRTYXRT0902
54 (2‐1/8) RRTYXRT1052 ‐ ‐ ‐ RRTYXRT1142 ‐ ‐ ‐
63.5 (2‐1/2) RRTYXRT1062 RRTYXRT0782 RRTYXRT1152 RRTYXRT0922
14
Actuator End
Outboard End for
8510B Only
Double D
Keyed
Actuator End
Outboard End for
8510B Only
Instruction Manual
ENVIRO-SEAL System - Rotary Valves
D101643X012
Table 7. Retrofit Kit Part Numbers for Fisher 8532, A31A, A31D and A11 Butterfly Valves
8532, A31A, A31D
Shaft
Valve Size, NPS Pressure Class
3 150, 300 14.3 (9/16) RRTYXRT0202 RRTYXRT0502
4 150, 300 17.5 (11/16) RRTYXRT0212 RRTYXRT0512
6 150, 300 23.8 (15/16) RRTYXRT0222 RRTYXRT0522
8
10
12
14
16
18
20 150 50.8 (2) RRTYXRT0652 24 150 63.5 (2‐1/2) RRTYXRT0662
Valve Size, NPS Pressure Class Shaft Diameter
3 4 19.1 (3/4) 14B3988X012 14B3989X012 6 28.6 (1‐1/8) 12B4105X012 12B4107X012
8 38.1 (1‐1/2) 13B9289X012 14B3985X012 10 44.5 (1‐3/4) 13B9285X012 13B9286X012 12 57.2 (2‐1/4) 14B1323X012 14B3978X012 14 63.5 (2‐1/2) 12B4111X012 12B4116X012 16 76.2 (3) 14B5651X022 14B5660X022 18 88.9 (3‐1/2) 14B5729X042 14B5736X042
1. Shaft diameter: Diameter through the packing box.
2. For larger shaft sizes, consult your Emerson sales office
150 23.8 (15/16) RRTYXRT0232 RRTYXRT0532 300 31.8 (1‐1/4) RRTYXRT0242 RRTYXRT0542 150 28.5 (1‐1/8) RRTYXRT0252 RRTYXRT0552 300 41.3 (1-5/8) RRTYXRT0572 ‐ ‐ ‐ 150 31.8 (1‐1/4) RRTYXRT0262 RRTYXRT0562 300 47.6 (1‐7/8) RRTYXRT0582 150 34.9 (1‐3/8) RRTYXRT0592 300 50.8 (2) RRTYXRT0602 150 38.1 (1‐1/2) RRTYXRT0612 300 57.2 (2‐1/4) RRTYXRT0622 150 44.5 (1‐3/4) RRTYXRT0632 300 63.5 (2‐1/2) RRTYXRT0642
A11
600
.
Diameter
(1)(2)
mm (Inch)
14.3 (9/16) 12B4122X012 12B4125X012
,
February 2019
Retrofit Kits
PTFE Graphite
PTFE Retrofit
Kits
Retrofit Kits
‐ ‐ ‐
Graphite
15
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
Repair Kits
PTFE repair kits include one packing set and two anti‐extrusion washers. Graphite packing sets include two packing rings and two anti‐extrusion rings. See table 8.
The 8510B has two packing boxes, one at the actuator end and one at the outboard end. A quantity of two of the appropriate kit is required to repair both ends.
WARNING
Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
Table 8. Repair Kits for Fisher Vee‐Ball, Eccentric Plug, 8560, 8510B and A41 Valves
Shaft Diameter mm (Inch) PTFE Kits Graphite Packing Set
12.7 (1/2)
15.9 (5/8)
19.1 (3/4)
25.4 (1)
31.8 (1‐1/4)
38.1 (1‐1/2)
44.5 (1‐3/4)
54.0 (2‐1/8)
63.5 (2‐1/2)
RRTYX000012 RRTYX000022 RRTYX000032
RRTYX000052 RRTYX000062
RRTYX000072 RRTYX000232
RRTYX000252 RRTYX000262
13B8816X012 13B8816X032 13B8816X052
13B8816X092 13B8816X112
13B8816X142 13B8816X152
13B8816X182 13B8816X162
16
Instruction Manual
ENVIRO-SEAL System - Rotary Valves
D101643X012
Table 9. Repair Kit Part Numbers for Fisher 8532, A31A, A31D and A11 Butterfly Valves
8532, A31A, A31D
Valve Size,
NPS
3 150, 300 14.3 (9/16) RRTYX000112 13B8816X022
4 150, 300 17.5 (11/16) RRTYX000122 13B8816X042
6 150, 300 23.8 (15/16) RRTYX000132 13B8816X082
8
10
12
14
16
18
20 150 50.8 (2) RRTYX000182 24 150 63.5 (2‐1/2) RRTYX000222
Valve Size, NPS Pressure Class Shaft Diameter PTFE Packing Kits
3 4 19.1 (3/4) 12B7414X012 12B7418X012 13B8816X052 16A6084X012 6 28.6 (1‐1/8) 12B9078X012 12B9084X012 13B8816X102 12B9077X012
8 38.1 (1‐1/2) 12B7462X012 12B7466X012 13B8816X142 16A6087X012 10 44.5 (1‐3/4) 13B9155X012 13B9159X012 14B3541X032 13B9160X012 12 57.2 (2‐1/4) 14B3647X012 14B3642X012 14B3541X052 13B2187X012 14 63.5 (2‐1/2) 12B7782X012 12B7783X012 14B3541X042 13B8709X012 16 76.2 (3) 14B5652X012 14B5656X012 14B3541X062 18A4189X012 18 88.9 (3‐1/2) 14B5730X012 14B5734X012 14B3541X072 14B5735X012
1. Shaft diameter: Diameter through the packing box.
2. For larger shaft sizes, consult your Emerson sales office
3. The A11 requires 2 Anti-Extrusion Rings.
Pressure Class
150 23.8 (15/16) RRTYX000132 13B8816X082 300 31.8 (1‐1/4) RRTYX000142 13B8816X122 150 28.5 (1‐1/8) RRTYX000092 13B8816X102 300 41.3 (1-5/8) RRTYX000152 ‐ ‐ ‐ 150 31.8 (1‐1/4) RRTYX000142 13B8816X122 300 47.6 (1‐7/8) RRTYX000162 150 34.9 (1‐3/8) RRTYX000172 300 50.8 (2) RRTYX000182 150 38.1 (1‐1/2) RRTYX000192 300 57.2 (2‐1/4) RRTYX000202 150 44.5 (1‐3/4) RRTYX000212 300 63.5 (2‐1/2) RRTYX000222
600
Shaft
Diameter
(1)(2)
mm (Inch)
,
14.3 (9/16) 12B9122X012 12B9121X012 13B8816X022 12B9118X012
.
PTFE Graphite Packing Set
A11
Extrusion Ring
Anti‐
Repair Kits
Graphite Packing
(3)
‐ ‐ ‐
Kits
February 2019
Packing Box Ring
17
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
A coupler is required for the following valve/actuator combinations when retrofitting an existing A31A or A31D with an ENVIRO‐SEAL packing system.
Table 10. Coupler Part Number for Fisher A31A or A31D Valves with Selected Actuators
SHAFT DIAMETER,
mm (INCH)
14.3 (9/16)
17.5 (11/16)
23.8 (15/16)
28.5 (1‐1/8)
31.8 (1‐1/4)
Valve Size Actuator Type
NPS 3 CL150/300 NPS 3 CL150/300 NPS 3 CL150/300
NPS 4 CL150/300 NPS 4 CL150/300 NPS 4 CL150/300 NPS 4 CL150/300
NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150 NPS 6 CL150/300, NPS 8 CL150
NPS 10 CL150 NPS 10 CL150 NPS 10 CL150 NPS 10 CL150 NPS 10 CL150 NPS 10 CL150 NPS 10 CL150 NPS 10 CL150
NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150
Fisher 1032 XL70 thru XL280 Fisher 1032 XL425 thru XL680 D and S Series (Elomatic) SR15
Fisher 1032 XL185 thru XL280 Fisher 1032 XL425 thru XL680
Bettis HD 521, 721, 722
D and S Series (Elomatic) S20
Fisher 1031 Size 26 Fisher 1031 Size 33
Fisher 1032 XL680‐XL1370
5M Gear Bettis CB 315 Bettis CB 415 Bettis CB 420 Bettis CB 520 Bettis CB 525 Bettis CB 725
Bettis HD 251.5
Bettis HD 521, 721, 722
Fire Sentry
Limitorque T‐100
Fisher 1031 Size 26 Fisher 1031 Size 33
Fisher 1032 XL680‐XL1370
Bettis CB 525 Bettis CB 725
Bettis HD 521, 721, 722
Fire Sentry
Limitorque T‐100
Fisher 1031 Size 26 Fisher 1031 Size 33
Fisher 1032 XL680 ‐ XL1370
Bettis CB 525 Bettis CB 725
Bettis HD 521, 721, 722
150 Bettis HD 731, 732
D and S Series (Elomatic) SR110
Limitorque SMB‐000‐5‐HOBC
Limitorque T‐250
Rotork 250
Coupler
Part No.
13B1596X012 13B1907X012 13B1595X012
13B1600X012 13B1908X012 13B1597X012 13B1599X012
13B1610X012 13B1611X012 13B1613X012 13B1601X012 13B1602X012 13B1905X012 13B1605X012 13B1906X012 13B1604X012 13B1606X012 13B1609X012 13B1603X012 13B1608X012 13B1607X012
13B1620X012 13B1621X012 13B1624X012 13B1614X012 13B1617X012 13B1615X012 13B1619X012 13B1618X012
13B1081X012 13B1082X012 13B1086X012 13B1073X012 13B1077X012 13B1074X012 13B1075X012 13B1076X012 13B1084X012 13B1246X012 13B1079X012
18
Instruction Manual
D101643X012
ENVIRO-SEAL System - Rotary Valves
February 2019
The existing couplers, listed below, can accommodate a retrofit with an ENVIRO‐SEAL packing system. Coupler replacement is not required when retrofitting the valve/actuator combinations listed below. For information about couplers for the A11 CL600 valves, contact your Emerson sales office
.
Table 11. Coupler Part Number for Fisher A31A or A31D Valves with Selected Actuators
SHAFT DIAMETER,
mm (INCH)
14.3 (9/16)
17.5 (11/16)
28.5 (1‐1/8)
31.8 (1‐1/4)
Valve Size Actuator Type
NPS 3 CL150/300 NPS 3 CL150/300 NPS 3 CL150/300 NPS 3 CL150/300
NPS 4 CL150/300 NPS 4 CL150/300 NPS 4 CL150/300 NPS 4 CL150/300
NPS 10 CL150 NPS 10 CL150
NPS 8 CL300, NPS 12 CL150 NPS 8 CL300, NPS 12 CL150
Bettis CB 315 Bettis CB 415 Bettis CB 420 Bettis CB 520
Bettis CB 315 Bettis CB 415 Bettis CB 420 Bettis CB 520
Bettis CB 420 Bettis CB 520
Bettis CB 420 Bettis CB 520
Coupler
Part No.
V160124X012 V160125X012 V151828X012 V154549X012
V160108X012 V160107X012 V151731X012 V154600X012
V160209X012 V160212X012
V160208X012 V160213X012
19
ENVIRO-SEAL System - Rotary Valves
February 2019
Instruction Manual
D101643X012
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher, ENVIRO-SEAL, and Vee-Ball are marks owned by one of the companies in the Emerson Automation Solutions business division of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore
www.Fisher.com
20
E1991, 2019 Fisher Controls International LLC. All rights reserved.
Loading...