Fisher Fisher easy-Drive 200L Quick Start Guide

Page 1
Quick Start Guide
D104725X012
easy-Drive 200L
March 2022
Fisher™ easy-Drive™ 200L Quick Start Guide
Mounting and travel configuration for your Fisher easy-Drive 200L actuator.
Before You Begin
Do not install, operate, or maintain a 200L actuator without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property
damage, it is important to carefully read, understand, and follow all the contents of this quick start guide, including all safety cautions and warnings. Refer to the Fisher easy-Drive 200L Instruction Manual
(D104331X012 installation in hazardous locations. If you have any questions about these instructions, contact your
Emerson sales office
WARNING
To avoid personal injury or property damage, keep hands and tools out of the actuator stem travel path. The actuator stem will move during calibration and positioning steps.
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal injury.
) for product specifications, custom setup information, maintenance procedures, and
before proceeding.
Note
Refer to easy-Drive 200L Instruction Manual (D104331X012 easy-Drive actuator as this will be needed to configure and calibrate the 200L.
) for wiring, Modbus setup and connecting the Configurator to an
www.Fisher.com
Page 2
easy-Drive 200L
March 2022
Quick Start Guide
D104725X012
Ensure Actuator Stem is in the Proper Position Prior to Mounting and Coupling
Your 200L actuator has internal hard stops to limit maximum travel within the actuator. A new actuator will be shipped from the factory at 6% off the lower internal hard stop, which is the recommended mounting position.
Note
If you are mounting a new actuator that has never been positioned and is still in its recommended mounting position of 6% of maximum travel, you can begin at step 5.
To set the stand-alone 200L actuator to the recommended mounting position of 6% of maximum travel, follow steps 1-4:
Step 1. Ensure use of a stand-alone 200L
(must be actuator only, no valve body).
X1520-1
Step 3. Perform Span Calibration from
Calibration tab.
Step 2. Using the Fisher easy-Drive Configurator,
select the “System” tab and then “Advanced Settings.” Select the valve type “Stop-to-Stop” from the drop-down options and click “Apply.”
Step 4. Position actuator to 6% travel.
Note
Stop-to-Stop is used for positioning the actuator to 6% off the lower travel stop. Select proper valve type and travel after mounting the 200L to the valve body.
2
Page 3
Quick Start Guide
D104725X012
easy-Drive 200L
Mount the Actuator to the Valve Body and Couple the Stems
Note
User supplied mounting bracket and stem coupler will be needed to complete this procedure.
Step 5. Supply a method of supporting the
weight of the valve and actuator during assembly.
Step 6. Push the valve stem down away from the
actuator to the valves closed position for push down to close valves.
Step 7. Mount the to the mounting bracket
supplied by the user. Tighten the actuator locknut to 205 N•m (151lb•ft).
Step 8. Lift or hoist the actuator and mounting
bracket onto the valve and mate the mounting bracket securely to the valve following the valve manufacturer's instructions.
Step 9. Make the stem connection between the
actuator and valve stems. When installing the user-supplied stem connector, be sure the actuator stem threads engage the threads of the stem connector by a distance equal to or greater than the diameter of the actuator stem.
50
1.969
25.75 MAX
1.013 MAX
27.3
1.07
GE94736
Refer to the easy-Drive 200L bulletin (D104361X012) for complete mounting specifications.
6.3
0.25
63
2.48
1/2-20UNF-2A
10-15
0.39-0.59
RETRACTED
83
3.27
244
9.61
EXTENDED
March 2022
mm
Inch
WRENCH FLATS
LOCKNUT
Select Proper Valve Type
Step 10.Refer to valve manufacturer
documentation to determine maximum valve travel. (Manufacturer specifications may vary.)
Step 12.Click on the “Valve Type” and select the
appropriate value that matches desired travel of the valve body for your application and is within manufacturer valve travel limits. Then click “Apply” to save the selection.
Step 11.In the Configurator, navigate to the
Calibration tab.
Note
Stop-to-Stop valve type selection should be avoided unless the valve is specifically designed with its own internal up and down hard stops within the valve body. Fixed travel settings are recommended and will set the travel from the valve seat (push down to close) up to a pre-defined amount of travel, e.g. '0.75” Fixed' setting, will set the full range of travel at 19 mm (0.75 inches) from the seat.
3
Page 4
easy-Drive 200L
March 2022
Quick Start Guide
Calibrate Travel of the Actuator to the Valve Assembly
D104725X012
Step 13.Ensure the process and valve are in a safe
state – the valve will move during the
Step 14.Navigate to the Calibration tab of the
Configurator
calibration steps.
Step 15.Press the “Calibrate Span” button to
initiate the span calibration. The software
Step 16.Verify valve is closed when commanded
to 0%.
will show a progress bar during the calibration and display “Valve Span Calibrated” when complete.
Step 17.Verify full desired travel is achieved when
commanded to 100% by confirming “Actual Position” in the Configurator is 100%.
Note
If actuator cannot achieve desired travel, review steps 5-12 to ensure all steps were followed, validate proper Configurator selections were made, and confirm the stems were properly coupled.
The valve/actuator assembly is now ready to be put into operation. If the 200L is not operating properly contact your
Emerson sales office
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher and easy-Drive are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay, 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore
www.Fisher.com
4
E 2022 Fisher Controls International LLC. All rights reserved.
.
Loading...