Fisher 38156 Parts Manual

Replacement Parts for Pre-Rinse Units
2011-0000
PRE-RINSE
GOOSENECK
SVL 1/4”
31” RISER
2902-12
WALL BRACKET
2943
PIPE CLAMP
MOUNT HOOK
66591
CONTROL
VALV E
47279
TEMPERATURE
CONTROL VALVE
2000-5003
SEAT WASHER
PART NO. 75154
38423
ISH
ER
C A
2000-7500
SCREW
2000-8000
RED BUTTON
AND
2000-8001
BLUE BUTTON
LEVER HANDLE
2000-3002
BIBB CAP
73657
DUCK GASKET
73741
WASHER
18848
RH SWIVEL
STEM
OR
18821
LH SWIVEL
STEM
1000-7502
SCREW
73521
LUBE
2916-151/2
15 1/2” HOSE
2922-5000
WASHER
2932-0002
WATTS N9 BACK-FLOW PREVENTER
BACKFLOW
PREVENTER
71390
INSULATED
HANDLE
71307
ULTRA SPRAY
VALV E
2949-9001
SCRUB BRUSH
2000-0002
HANDLE LEVER KIT
16” SWING SPOUT
14” SWING SPOUT
12” SWING SPOUT
10” SWING SPOUT
8” SWING SPOUT
54518
RH SWIVEL STEM
REPAIR KIT
OR
54526
LH SWIVEL STEM
REPAIR KIT
12912
ANGLE STOP
WITH KEY
6” SWING SPOUT
MANFACTURING COMPANY
PO BOX 60, TULARE, CA 93275
(800)421-6162, FAX: (800)832-8238
www.fisher-mfg.com
54445
54429
54410
54402
54399
54380
ANGLE STOP
W/ CROSS
HANDLES
1000-5005
12904
O-RING
2912-7501
2909-6000
71420
SPRAY VALVE
REPAIR KIT
64610
1000-5001
2912-6000
64580
INCLUDES:
1000-5003 WASHER
1000-7502 SCREW
2922-5000
64637
2909-5000
64645
ADD-ON CONTROL
VALVE LESS SPOUT
SPOUT NUT
55867
2.2 GPM
AERATOR
SNAP RING
SUPPLY LINE
1/2”F X 1/2”F X 36”
SUPPLY LINE
1/2”F X 1/2”M X 36”
38318
73684
20020
1600-5000
SPOUT
O-RINGS
73521
LUBE
19119
SWIVEL SPOUT
RETRO-FIT KIT
10022
10006
REV. A
fisher manufacturing company
PRHS-SV-SDTL
Product Installation Guide
Limited One Year Warranty
Fisher Manufacturing Company warrants its products and parts thereof (except as noted below) against defects in materials or workmanship for a period of one year after the date of original purchase. During this period Fisher Manufacturing Company will replace a defective product or part without charge to you, provided that the entire product is delivered to Fisher Manufacturing Company. All transportation and insurance charges for shipping the product to and from Fisher Manufacturing Company must be borne by you. Charges for transportation and insurance may, at the option of Fisher Manufacturing Company, be refunded depending upon our investigation of the warranty claim. This warranty does not cover external fi nish (except at date of original purchase) or labor costs not specifi cally authorized by Fisher Manufacturing Company.
A full and complete copy of our One Year limited warranty is available upon request.
Warning:This product can expose you to chemicals including Lead, Nickel (Metallic), Di(2-ethylhexyl) phathalate (DEHP) which are known to the State of California to cause cancer, and Lead. Di(2-ethylhexyl) phathalate (DEHP) which are known to the State of Califorina to cause birth defects or reproductive harm. For more information go to:
www.P65Warnings.ca.gov.
KEEP THIS MANUAL FOR FUTURE REFERENCE
fisher manufacturing company - toll free: 800-421-6162 fax: 800-832-8238
www.fi sher-mfg.com
38156 - SS PRERINSE SVL SDLH
ANSI/A112.18.1M, ANSI/NSF 61.9
Installation Instructions for Pre-Rinse Units
BE SURE TO CHECK WITH YOUR LOCAL DEPARTMENT HAVING JURISDICTION REGARDING BACKFLOW PREVENTION
Installation Notes:
• Be sure to shut off water supply before beginning.
• Use pipe thread sealant such as PST on all threaded joints.
• Check the packaging for missing items BEFORE beginning installation. If items are missing, contact your supplier.
Tools Required for Installation
• Medium Sized Crescent Wrenches
• Pipe Thread Sealant
• Phillips Screwdriver
• 7/16” Drill Bit
• 1/8” Allen Wrench
Installation Instructions
1. If no add-on faucet will be installed, proceed to step 2 If installing an add-on faucet, mount the small riser to the control valve body using thread sealant. Thread the add-on faucet to the other end of the small riser, again using thread sealant.
2. Mount control valve 66591 to deck by inserting nipple through pre-cut hole and attaching slip joint beneath the deck. Tighten slip joint until control valve is se­cure.
3. Attach mixing valve 47279 to control valve 66561. Be sure to use thread sealant when attaching control valves. Install your water source to the 47279 mixing valve.
4. Apply thread sealant to one end of the riser’s threads, after thread sealant is applied insert into the single deck control valve inlet and tighten, ( or add on valve if installing add-on faucet).
5. If no wall bracket is to be installed, proceed to Step 6, otherwise do the following:
a. Locate and drill a Ø7/16” hole in the wall directly
behind and about 3/4 the way up the riser pipe.
b. Loosely attach the front and back of the pipe clamp
onto the riser pipe.
c. Hold the wall bracket fl ange against the wall,
centered with the hole. Use the wall screws and a screw driver to mount the fl ange to the wall.
d. Slide part, but not all, of the wall bracket rod non-
threaded end fi rst through the center hole of the ange and into the wall.
e. Align the rod with the pipe clamp and thread the
rod into the pipe clamp. Be sure the rod is level by adjusting the pipe clamp position.
f. Once level, fi x the rod in place by tightening both
the set screw located in the fl ange and the pipe clamp screws.
6. Apply thread sealant to riser’s threads and attach to swivel gooseneck sub assembly.
7. Apply thread sealant to SS hose and connect to swivel gooseneck sub assembly.
8. Fit one of the handle gaskets inside the outlet of the insulated handle and mount the spray valve onto it.
PST
Step 1
Step 2
Step 3
47279
66591
66591
Thread Sealant
Goes Here
ISHER CA
I SHE
R C
A
I S
H ER
C A
Slip Joint
Thread Sealant
Goes Here
Attach Supply
Lines Here
Installation Instructions Continued
9. Fit the other handle gasket inside the inlet of the insulated handle and mount the handle onto the SS hose. If installing backfl ow preventer, attach it between the SS hose and insulated handle. Be sure that gaskets are used on both sides of the backfl ow preventer.
10. If installing a brush, do so by pressing brush into the bumper of the spray valve until secure.
11. To install swing spout to add-on faucet, apply o-ring lube to the o-rings on the swing spout. Make sure the white snap ring is in place before mounting the swing spout. Mount the swing spout and tighten the swing spout nut onto the add-on faucet spout outlet.
12. If no hose clamp will be installed, proceed to step
13. If installing hose clamp, place the hose clamp on the riser. Adjusting it to the desired height and tighten.
13. Turn on water supply and check for leaks.
Step 5 Step 6
Excess Rod Length
Trim to Fit (optional)
Wall
Wall Screw
Set Screw
Thread Sealant
Goes Here
Pipe
Clamp
Riser Pipe
Step 9 Step 10 Step 11 Step 12
Handle Gasket
WATTS N9 BACK-FLOW PREVENTER
Step 4
Step 7
Thread Sealant
Goes Here
Swing Spout
Apply O-Ring
Lube Here
IS
HER
C
A
I S H
E R C
A
Thread Sealant
Goes Here
Step 8
Handle
Gasket
ISHER CA