Fisher 37494 Parts List

7
PREVENTER
BACK-FLOW
WATTSN9
8
fisher manufacturing company
Handle Gasket
9 10
11
Swing Spout
Apply Oring
Lube
Handle Gasket
Stainless Steel Single Wall Control Pre-Rinse Unit
Product Installation Guide
Since 1936, Fisher Manufacturing Company has man­ufactured heavy-duty, high quality plumbing products and hardware specialties for the food service industry. For three generations, the Fisher family has ad­hered to a strict dedication of overall value. When you install Fisher products… you install the best. Our hardware is manufactured with the standard­ization of internal mechanisms. Every piece of equipment we make is rigorously tested in both our modern in-house testing center and in actual field situations under extreme conditions. Every detail is thoroughly checked. Before we make our products available to you, they pass each and ev­ery test. You get proven performance. Guaranteed.
Limited One Year Warranty
Fisher Manufacturing Company warrants its prod­ucts and parts thereof (except as noted below) against defects in materials or workmanship for a period of one year after the date of original purchase. During this period Fisher Manufacturing Company will re­place a defective product or part without charge to you, provided that the entire product is delivered to Fisher Manufacturing Company. All transporta­tion and insurance charges for shipping the prod­uct to and from Fisher Manufacturing Company must be borne by you. Charges for transportation and insurance may, at the option of Fisher Manu­facturing Company, be refunded depending upon our investigation of the warranty claim. This war­ranty does not cover external finish (except at date of original purchase) or labor costs not specifi­cally authorized by Fisher Manufacturing Company.
#53511 - Stainless Steel Pre-Rinse, Spring Style Single Wall Control Valve, 21” Riser, 36” Hose & Spray Valve with Lever Handles
#75191 - Stainless Steel Pre-Rinse, Spring Style Single Wall Control Valve, 21” Riser, 36” Hose & Spray Valve with Wrist Handles
PART NO. 39896
A full and complete copy of our One Year limited warranty is available upon request.
WARNING:
Proposition 65 requires that we provide you with the following notice: “This product Contains A Chemical
Known To The State Of California To Cause Birth Defects Or Other Reproductive Harm.”
KEEP THIS MANUAL FOR FUTURE REFERENCE
ANSI/A112.18.1M, ANSI/NSF 61.9
FISHER MANUFACTURING COMPANY, TOLL FREE: 800-421-6162, FAX:800-832-8238
www.noleadfaucet.com
PST
Installation Instructions for Pre-Rinse Units
BE SURE TO CHECK WITH YOUR LOCAL DEPARTMENT HAVING JURISDICTION REGARDING BACKFLOW PREVENTION
Installation Notes:
• Be sure to shut off water supply before beginning.
• Use pipe thread sealant such as PST on all threaded joints.
• Check the packaging for missing items BEFORE beginning installation. If items are missing, contact your supplier.
Tools Required for Installation
• Medium Sized Crescent Wrenches
• Pipe Thread Sealant
• Phillips Screwdriver
• 7/16” Drill Bit
• 1/8” Allen Wrench
Installation Instructions
1. Mount the small riser to the control valve body using thread sealant. Thread the add-on faucet to the other end of the small riser, again using thread sealant.
2. Mount control valve body to either a wall with male supply nipples, or a backsplash with nipples (not included). Be sure to use pipe thread sealant on the supply nipple threads.
3. Mount the pipe to hose adapter to the enclosed riser using thread sealant. Mount the other end of the riser to the female outlet of the add-on body.
4. If no wall bracket is to be installed, proceed to Step 5, otherwise do the following:
a. Locate and drill a Ø7/16” hole in the wall directly behind and about 3/4 the way up the riser pipe. b. Loosely attach the front and back of the pipe clamp onto the riser pipe. c. Hold the wall bracket fl ange against the wall, centered with the hole. Use the wall screws and a screw driver
to mount the fl ange to the wall.
d. Slide part, but not all, of the wall bracket rod non-threaded end fi rst through the center hole of the fl ange and
into the wall.
e. Align the rod with the pipe clamp and thread the rod into the pipe clamp. Be sure the rod is level by adjusting
the pipe clamp position.
f. Once level, fi x the rod in place by tightening both the set screw located in the fl ange and the pipe clamp
screws.
5. Slip the hose hook over the pipe to hose adapter. Using thread sealant and a crescent wrench, thread the SS hose into the pipe to hose adapter.
6. Install gooseneck spring by slipping SS hose through the spring. Spring will fi t over adapter which holds it in an upright position. Note: Be sure spring is installed as shown. DO NOT INSTALL SHORT BEND DOWN.
7. Fit one of the handle gaskets inside the outlet of the insulated handle and mount the spray valve onto it.
8. Fit the other handle gasket inside the inlet of the insulated handle and mount the handle onto the SS hose. If installing backfl ow preventer, attach it between the SS hose and insulated handle. Be sure that gaskets are used on both sides of the backfl ow preventer.
9. If installing a brush, do so by pressing brush into the bumper of the spray valve until secure.
10. To install swing spout to add-on faucet, apply o-ring lube to the o-rings on the swing spout. Make sure the
white snap ring is in place before mounting the swing spout. Mount the swing spout and tighten the swing spout nut onto the add-on faucet spout outlet.
11. Turn on water supply and check
1
Apply Thread Sealant
3
Apply Thread Sealant
5 6
Apply Thread Sealant
2
4
1/2” NPT Supply
Nipples (not included)
Ø7/8”
1/2” Elbows
(not included)
Excess Rod Length Trim to Fit
(optional)
Wall
Wall Screw
Set Screw
Pipe Clamp
Riser Pipe
Spring Bend
On This Side
Loading...