Fisher 36269 Parts Manual

Replacement Parts for Pre-Rinse Units
GOOSENECK
2925-6300
HOSE HOOK
2902-12
WALL BRACKET
TEMPERATURE
CONTROL VALVE
2000-5003
SEAT WASHER
PART NO. 75141
2924-6000
SPRING
CONTROL
47279
66591
VALV E
72813
CHEM TEE
71315
3/8” PIPE
16” RISER
ISHER CA
2000-7500
SCREW
2000-8000
RED BUTTON
AND
2000-8001
BLUE BUTTON
2000-2301
LEVER HANDLE
2000-3002
BIBB CAP
73657
DUCK GASKET
73741
WASHER
18821
LH SWIVEL STEM
OR
18848
RH SWIVEL STEM
1000-7502
SCREW
73521
LUBE
2914
STAINLESS STEEL
HOSE 36”
2922-5000
WASHER
2932-0002
WATTS N9 BACK-FLOW PREVENTER
BACKFLOW
PREVENTER
71390
INSULATED
HANDLE
71307
ULTRA SPRAY
VALV E
2949-9001
SCRUB BRUSH
3000-0000
RH SWIVEL REPAIR KIT
2000-0002
HANDLE LEVER KIT
54518
RH SWIVEL STEM
REPAIR KIT
OR
54526
LH SWIVEL STEM
REPAIR KIT
ANGLE STOP
ANGLE STOP
MANFACTURING COMPANY
PO BOX 60, TULARE, CA 93275
(800)421-6162, FAX: (800)832-8238
www.fisher-mfg.com
10022 (36”)
SUPPLY LINE 1/2” F X 1/2” F
10006 (36”)
SUPPLY LINE
1/2” M X 1/2” F
1000-7502
SEAT SCREW
73521
2000-5003
LUBE
SEAT WASHER
54445
16” SWING SPOUT
54429
14” SWING SPOUT
54410
12” SWING SPOUT
54402
10” SWING SPOUT
54399
8” SWING SPOUT
54380
6” SWING SPOUT
12912
WITH KEY
12904
W/ CROSS HANDLES
1000-5005
O-RING
18848
RH SWIVEL
STEM
2912-2501
2912-7501
2909-6000
DUCK GASKET
73741
WASHER
73657
2000-3002
BIBB CAP
2.2 GPM
AERATOR
LEVER HANDLE
55867
11355
SPRAY VALVE
REPAIR KIT
1000-3301
1000-5001
2912-6000
1000-0001
INCLUDES:
1000-5003 WASHER
1000-7502 SCREW
2922-5000
1000-0003
2909-5000
2909-3400
2000-2301
2000-8000
RED BUTTON
AND
2000-8001
BLUE BUTTON
38318
ADD-ON CONTROL
VALVE LESS SPOUT
73684
SPOUT NUT
20020
SNAP RING
1600-5000
SPOUT
O-RINGS
73521
LUBE
19119
SWIVEL SPOUT
RETRO-FIT KIT
2000-7500
SCREW
REV. A
fisher manufacturing company
PRHS-SIA-SDTL
Product Installation Guide
Limited One Year Warranty
Fisher Manufacturing Company warrants its products and parts thereof (except as noted below) against defects in materials or workmanship for a period of one year after the date of original purchase. During this period Fisher Manufacturing Company will replace a defective product or part without charge to you, provided that the entire product is delivered to Fisher Manufacturing Company. All transportation and insurance charges for shipping the product to and from Fisher Manufacturing Company must be borne by you. Charges for transportation and insurance may, at the option of Fisher Manufacturing Company, be refunded depending upon our investigation of the warranty claim. This warranty does not cover external fi nish (except at date of original purchase) or labor costs not specifi cally authorized by Fisher Manufacturing Company.
A full and complete copy of our One Year limited warranty is available upon request.
Warning:This product can expose you to chemicals including Lead, Nickel (Metallic), Di(2-ethylhexyl) phathalate (DEHP) which are known to the State of California to cause cancer, and Lead. Di(2-ethylhexyl) phathalate (DEHP) which are known to the State of Califorina to cause birth defects or reproductive harm. For more information go to:
www.P65Warnings.ca.gov.
KEEP THIS MANUAL FOR FUTURE REFERENCE
fisher manufacturing company - toll free: 800-421-6162 fax: 800-832-8238
www.fi sher-mfg.com
#36250 - SS PRERINSE SPV SDLH 06SS
#36269 - SS PRERINSE SPV SDLH 08SS
#36277 - SS PRERINSE SPV SDLH 10SS
#36285 - SS PRERINSE SPV SDLH 12SS
#36412 - SS PRERINSE SPV SDLH 14SS
#36455 - SS PRERINSE SPV SDLH 16SS
ANSI/A112.18.1M, ANSI/NSF 61.9
Installation Instructions for Pre-Rinse Units
BE SURE TO CHECK WITH YOUR LOCAL DEPARTMENT HAVING JURISDICTION REGARDING BACKFLOW PREVENTION
Installation Notes:
• Be sure to shut off water supply before beginning.
• Use pipe thread sealant such as PST on all threaded joints.
• Check the packaging for missing items BEFORE beginning installation. If items are missing, contact your supplier.
Tools Required for Installation
• Medium Sized Crescent Wrench
• Pipe Thread Sealant
• Phillips Screwdriver
• 7/16” Drill Bit
Installation Instructions
1. Mount the small riser to the control valve body using thread sealant. Thread the add-on faucet to the other end of the small riser, again using thread sealant.
2. Mount control valve 66591 to deck by inserting nipple through pre-cut hole and attaching slip joint beneath the deck. Tighten slip joint until control valve is secure.
3. Attach temperature valve 47279 to control valve
12890. Be sure to use thread sealant when attach-
ing control valves. If required, install supply lines to temperature valve 47279.
4. Mount the pipe to hose adapter to the enclosed riser using thread sealant. Mount the other end of the riser to the female outlet of the add-on body.
5. If no wall bracket is to be installed, proceed to Step 6, otherwise do the following:
a. Locate and drill a Ø7/16” hole in the wall directly
behind and about 3/4 the way up the riser pipe.
b. Loosely attach the front and back of the pipe
clamp onto the riser pipe.
c. Hold the wall bracket fl ange against the wall,
centered with the hole. Use the wall screws and a screw driver to mount the fl ange to the wall.
d. Slide part, but not all, of the wall bracket rod non-
threaded end fi rst through the center hole of the ange and into the wall.
e. Align the rod with the pipe clamp and thread the
rod into the pipe clamp. Be sure the rod is level by adjusting the pipe clamp position.
f. Once level, fi x the rod in place by tightening both
the set screw located in the fl ange and the pipe clamp screws.
6. Slip the hose hook over the pipe to hose adapter. Using thread sealant and a crescent wrench, thread the SS hose into the pipe to hose adapter.
7. Install gooseneck spring by slipping SS hose through the spring. Spring will fi t over adapter which holds it in an upright position. Note: Be sure spring is installed as shown. DO NOT INSTALL SHORT BEND DOWN.
8. Fit one of the handle gaskets inside the outlet of the insulated handle and mount the spray valve onto it.
PST
Step 1
Step 2
Step 3
47279
66591
66591
IS H
E R
C
A
IS
H ER CA
Thread Sealant
Goes Here
IS
H
ER
CA
Slip Joint
Thread Sealant
Goes Here
Attach Supply
Lines Here
Installation Instructions Continued
9. Fit the other handle gasket inside the inlet of the insulated handle and mount the handle onto the SS hose. If installing backfl ow preventer, attach it between the SS hose and insulated handle. Be sure that gaskets are used on both sides of the backfl ow preventer.
10. If installing a brush, do so by pressing brush into
the bumper of the spray valve until secure.
11. To install swing spout to add-on faucet, apply
o-ring lube to the o-rings on the swing spout. Make sure the white snap ring is in place before mounting the swing spout. Mount the swing spout and tighten the swing spout nut onto the add-on faucet spout outlet.
12. Turn on water supply and check for leaks.
Step 5 Step 6
Excess Rod Length
Trim to Fit (optional)
Wall
Wall Screw
Thread Sealant
Goes Here
Set Screw
Pipe
Clamp
Riser Pipe
Step 9 Step 10 Step 11 Step 12
Handle Gasket
WATTS N9 BACK-FLOW PREVENTER
Step 4
Step 7
Spring Bend
On This Side
Swing Spout
Apply O-Ring
Lube Here
IS H
ER CA
I S H
E R C
A
Thread Sealant
Goes Here
Step 8
Handle Gasket
IS H E
R C A
Loading...