Fisher 34428 PARTS LIST

2924-6000
SPRING
GOOSENECK
2925-6300
HOSE HOOK
2926-3300
PIPE TO HOSE
ADAPTER
2902-12
WALL BRACKET
2200-CV
CONTROL
VALVE
PART NO. 36196
Replacement Parts for Pre-Rinse Units
2914
STAINLESS STEEL
2927-4303
3/8” PIPE
16” RISER
2000-7500
SCREW
2000-8000
RED BUTTON
AND
2000-8001
BLUE BUTTON
2000-2301
LEVER HANDLE
2000-3002
BIBB CAP
10464
DUCK GASKET
2000-5000
WASHER
2000-3406
LH CHECK STEM
OR
2000-3407
RH CHECK STEM
2000-6000
SPRING
2000-0001
RETAINER
ASSEMBLY
10456
LUBE
HOSE 36”
2922-5000
WASHER
2932-0002
IN-LINE CHECK
WATTSN9 BACK-FLOW PREVENTER
VALVE
2913
INSULATED
HANDLE
2949 ULTRA SPRAY
VALVE
2949-9001
SCRUB BRUSH
2400-2103
ELBOWS
3000-0000
RH SWIVEL REPAIR KIT
16” SWING SPOUT
2000-0004
RH CHECK STEM
REPAIR KIT
OR
2000-0005
LH CHECK STEM
REPAIR KIT
3200-2306
ECCENTRIC
FLANGES
(800)421-6162, FAX: (800)832-8238
14” SWING SPOUT
12” SWING SPOUT
10” SWING SPOUT
8” SWING SPOUT
6” SWING SPOUT
1/2” ECCENTRICS
MANFACTURING COMPANY
PO BOX 60, TULARE, CA 93275
www.fisher-mfg.com
2949-3001
NOZZLE FOR
2949 SPRAY
VALVE
2949-8600
CUP WASHER
1000-7502
SEAT SCREW
10456
LUBE
SEAT WASHER
3967
3964
3963
3962
3961
3960
3200-2307
10014 (24”)
10022 (36”)
SUPPLY LINE 1/2” F x 1/2” F
10049 (24”)
10006 (36”)
SUPPLY LINE 1/2” M x 1/2” F
RH SWIVEL
2000-5003
2200-0000
NIPPLE KIT
2949-9002
BLUE BUMPER
3000-0011
STEM
2000-5000
WASHER
2200-5000
ECCENTRIC
GASKETS
1000-5005
O-RING
2912-2501
2912-7501
2909-6000
ANGLE STOP
WITH KEY
10464
DUCK GASKET
12564
2.2 GPM
AERATOR
1792
2000-3002
BIBB CAP
1000-5003 WASHER
1000-7502 SCREW
1790-1
ANGLE STOP
W/ CROSS
HANDLES
2000-2301
LEVER HANDLE
2000-8000
RED BUTTON
2000-8001
BLUE BUTTON
2901-0000
ADD-ON CONTROL
VALVE LESS SPOUT
15621
SPOUT NUT
2002
SNAP RING
1600-5000
SPOUT
O-RINGS
10456
LUBE
SWIVEL SPOUT
RETRO-FIT KIT
REV. C
11355
SPRAY VALVE
REPAIR KIT
1000-3301
1000-5001
2912-6000
1000-0001
INCLUDES:
2922-5000
1000-0003
2909-5000
2909-3400
2000-7500
SCREW
AND
19119
fisher manufacturing company
8” Adjustable Wall Mount Pre-Rinse Unit
Product Installation Guide
Limited One Year Warranty
Fisher Manufacturing Company warrants its products and parts thereof (except as noted below) against defects in materials or workmanship for a period of one year after the date of original purchase. During this period Fisher Manufacturing Company will replace a defective product or part without charge to you, provided that the entire product is delivered to Fisher Manufacturing Company. All transportation and insurance charges for shipping the product to and from Fisher Manufacturing Company must be borne by you. Charges for transportation and insurance may, at the option of Fisher Manufacturing Company, be refunded depending upon our investigation of the warranty claim. This warranty does not cover external fi nish (except at date of original purchase) or labor costs not specifi cally authorized by Fisher Manufacturing Company.
A full and complete copy of our One Year limited warranty is available upon request.
WARNING:
Proposition 65 requires that we provide you with the following notice: “This product Contains A Chemical
Known To The State Of California To Cause Birth Defects Or Other Reproductive Harm.”
KEEP THIS MANUAL FOR FUTURE REFERENCE
fisher manufacturing company - toll free: 800-421-6162 fax: 800-832-8238
#34355 - Pre-Rinse Unit: 8” Adjustable Wall Mount, Wall
Bracket & Add-On Faucet with 6” Swing Spout
#34363 - Pre-Rinse Unit: 8” Adjustable Wall Mount, Wall
Bracket & Add-On Faucet with 8” Swing Spout
#34371 - Pre-Rinse Unit: 8” Adjustable Wall Mount, Wall
Bracket & Add-On Faucet with 10” Swing Spout
#34398 - Pre-Rinse Unit: 8” Adjustable Wall Mount, Wall
Bracket & Add-On Faucet with 12” Swing Spout
#34401 - Pre-Rinse Unit: 8” Adjustable Wall Mount, Wall
Bracket & Add-On Faucet with 14” Swing Spout
#34428 - Pre-Rinse Unit: 8” Adjustable Wall Mount, Wall
Bracket & Add-On Faucet with 16” Swing Spout
ANSI/A112.18.1M, ANSI/NSF 61.9
www.fi sher-mfg.com
R
R
R
Installation Instructions for Pre-Rinse Units
IISSHHEERR IISSHHEERR
IISSHHEERR
IISSHHEERR IISSHHEERR
IISSHHEERR
IISSHHEERR IISSHHEERR
IISSHHEERR
BE SURE TO CHECK WITH YOUR LOCAL DEPARTMENT HAVING JURISDICTION REGARDING BACKFLOW PREVENTION
Installation Notes:
• Be sure to shut off water supply before beginning.
• Use pipe thread sealant such as PST on all threaded joints.
• Check the packaging for missing items BEFORE beginning installation. If items are missing, contact your supplier.
Tools Required for Installation
• Medium Sized Crescent Wrenches
• Pipe Thread Sealant
• Phillips Screwdriver
• 7/16” Drill Bit
• 1/8” Allen Wrench
Installation Instructions
1. Insert the gasket into the groove on the eccentric. Making sure gasket is in place, loosely mount the eccentric and fl ange onto the control valve body.
2. Mount the small riser to the control valve body using thread sealant. Screw the add-on faucet to the other end of the small riser, again using thread sealant.
3. Mount control valve body to either a wall with male supply nipples, or a backsplash with nipples (not included). Be sure to use pipe thread sealant on the supply nipple threads. Adjust the eccentrics as needed in order to mount the control valve level. Once level, tighten the eccentrics.
4. Mount the pipe to hose adapter to the enclosed riser using thread sealant. Mount the other end of the riser to the female outlet of the add-on body.
5. If no wall bracket is to be installed, proceed to Step 6, otherwise do the following:
a. Locate and drill a Ø7/16” hole in the wall directly
behind and about 3/4 the way up the riser pipe.
b. Loosely attach the front and back of the pipe
clamp onto the riser pipe.
c. Hold the wall bracket fl ange against the wall,
centered with the hole. Use the wall screws and a screw driver to mount the fl ange to the wall.
d. Slide part, but not all, of the wall bracket rod non-
threaded end fi rst through the center hole of the ange and into the wall.
e. Align the rod with the pipe clamp and thread the
rod into the pipe clamp. Be sure the rod is level by adjusting the pipe clamp position.
f. Once level, fi x the rod in place by tightening both
the set screw located in the fl ange and the pipe clamp screws.
6. Slip the hose hook over the pipe to hose adapter. Using thread sealant and a crescent wrench, thread the SS hose into the pipe to hose adapter.
7. Install gooseneck spring by slipping SS hose through the spring. Spring will fi t over adapter which holds it in an upright position. Note: Be sure spring is installed as shown. DO NOT INSTALL SHORT BEND DOWN.
PST
Step 1
Gasket
Eccentric
Step 2
Thread Sealant
Goes Here
IISSHHEER
Step 3
Ø7/8”
IISSHHEER
IISSHHEER
1/2” NPT Supply
Nipples (not included)
7 3/4” - 8 1/4
[196.9 - 209.6mm]
7 3/4” - 8 1/4
[196.9 - 209.6mm]
Flange
Installation Instructions Continued
8. Fit one of the handle gaskets inside the outlet of the insulated handle and mount the spray valve onto it.
9. Fit the other handle gasket inside the inlet of the insulated handle and mount the handle onto the SS hose. If installing backfl ow preventer, attach it between the SS hose and insulated handle. Be sure that gaskets are used on both sides of the backfl ow preventer
10. If installing a brush, do so by pressing brush into
the bumper of the spray valve until secure.
11. To install swing spout to add-on faucet, apply
o-ring lube to the o-rings on the swing spout. Make sure the white snap ring is in place before mounting the swing spout. Mount the swing spout and tighten the swing spout nut onto the add-on faucet spout outlet.
12. Turn on water supply and check for leaks.
Step 5 Step 6
Excess Rod Length
Trim to Fit (optional)
Wall
Wall Screw
Set Screw
Pipe
Clamp
Riser Pipe
Step 9 Step 10 Step 11
Handle Gasket
WATTSN9 BACK-FLOW PREVENTER
Spring Bend
On This Side
Thread Sealant
Goes Here
Swing Spout
Apply O-Ring
Lube Here
Step 4
Step 7
Thread Sealant
Goes Here
Step 8
Handle Gasket
Step 12
Loading...