mation about the product, and instructions for its installation,
operation and maintenance. Opera-
tors and other technical personnel responsible for
the equipment must read this thoroughly before attempting to install or operate this equipment. A
copy of this manual must always be kept accessible at the place of work for reference by concerned
personnel.
Chapter 1 (sections 1.2 through 1.7) contains general as well as specific safety instructions. Chapters 2 through 10, covering topics ranging from
intended purpose of the equipment to its final disposal, also include important points relating to
safety. Overlooking or ignoring any of these safety
points can endanger humans and animals, and
possibly cause damage to other equipment.
1.2.Personnel Qualification
Personnel responsible for installation, operation,
maintenance and inspection of this product must
have the qualifications, training and experience
necessary to carry out such work on this type of
equipment.
1.3.Risks of Disregarding Safety Instructions
Disregarding safety instructions, use of this product for purposes for which it is not intended, and/
or operation of this product outside the limits specified for any of its technical parameters, can result
in harm to persons, the environment, or the plant
on which it is installed. Fischer Mess- und Regeltechnik GmbH will not be responsible for consequences in such circumstances.
Page 2
1.4.Safety Instructions for Operators
Sensor element
Safety instructions for the proper use of this product must
be followed. This information must be available at all
times to by personnel responsible for installation, operation, maintenance and inspection of this product. Adequate steps must be taken to prevent the occurrence of
hazardous conditions that can be caused by electric energy and
the convertible energy of the process media. Such conditions can, for example, be the result of improper electrical or process connections. Detailed information is
available in relevant published norms (DIN EN, UVW in
Germany; and equivalents in other countries), industrial
standards such as DVWG, Ex-, GL-, VDE guidelines, as
well as regulations of the local authorities (e.g., EVUs in
Germany).
1.5.Modifications Forbidden
Modification or other technical alteration of the product is
not permissible. This also applies to the use of unauthorized spare parts for repair / maintenance of the product.
Any modifications to this product, if and as necessary,
should be done only by Fischer Mess- und Regeltechnik
GmbH.
1.6.Operational Restrictions
The operational reliability of the product is guaranteed
only when used for intended purposes. The product must
be selected and configured for use specifically with defined process media. The limiting values of operating parameters, as given in the product specification sheet,
must never be crossed.
3.Product Descriptions and Functions
3.1.Functional Scheme
3.2.Principles of Operation
The instrument is based on a capacitance sensor ele-
ment and can measure positive gauge, negative gauge
or differential pressure.
The pressure is measured directly by a micromachined
silicon-on-glass differential capacitance sensor element.
Pressure changes cause capacitance changes interpreted by the integrated electronics.
4.Installation
The electronic module is mounted on a flat plate or panel,
for which it has 4 holes at the rear for self-tapping screws
∅3.5 mm. A wall-mounting plate is available as an option
(s. 13. Ordering Code).
The pressure transmitters are calibrated at the factory
while mounted vertically, pressure ports downward.
However, they can be mounted in any orientation.
IP65 protection for the housing is guaranteed only if suitable connecting cable is used.
1.7.Safety Considerations during Installation and
Maintenance
The safety instructions given in this manual, existing national regulations relating to accident prevention, and the
internal safety rules and procedures of the user organization regarding safety during installation, operation and
servicing must all be followed meticulously.
It is the responsibility of the users to ensure that only suitably qualified and experienced technical personnel are
used for installation, operation and servicing of this
equipment.
2.Intended Applications
The DE23 is a 2-wire transmitter. It is suitable for accurate measurement of low positive / negative gauge pressure or differential pressure of air and gases.
If the instrument is intended for outdoor application, we
highly recommend using an adequate protective housing
(or at least a big enough shelter) as protection against
UV-radiation on the membrane keyboard and against exposure of the instrument to rain or snow.
4.1.Process Connections
•Only technicians who are qualified and authorized for
this type of work should undertake installation.
•Ensure that the process equipment and pressure lines are at atmospheric pressure before making pressure connections to the instrument.
•The instrument should be provided with suitable protection against pressure surges (e.g., snubber or pulsation damper).
•Ensure that the mechanical configuration and materials of construction of the instrument are compatible
with the process media.
2
Page 3
•Ensure that process pressure is always less than the
2-wire
specified safe pressure rating.
•Carefully check the pressure-tightness of all pressure
connections before start-up.
Do not blow into the pressure
connections!
•Pressure lines must be kept as short as possible and
must not have short bends to avoid measurement errors induced by pressure line delays.
5.1.Pressure Connections
The instruments pressure ports are marked by "+" and "-"
symbols. For differential pressure applications the "+"
port must be connected to the higher pressure and the "-"
port should be connected to the lower pressure.
4.2.Electrical Connection
•Only technicians who are qualified and authorized for
this type of work should undertake installation.
•Electrical connections must conform to relevant international, national and local regulations and norms relating to electrical and instrumentation installations.
•Switch off electrical power to the plant before attempting electrical installation work of any kind.
•Make electrical connections to the instrument through
a suitable fuse.
4.3.Connection Scheme
Nominal supply voltage and the operating supply voltage
range are indicated under 11. Specifications. The maximum output signal loads are indicated under 11. Specifications.
5.Commissioning
•Power supply and pressure lines to the instrument
must be correctly selected to meet operational requirements, and installed in way that does not cause
physical stress to the instrument.
•If pressure lines are used to connect the pressure instrument and the process vessel / pipe, the pressure
lines must have a downward gradient throughout,
from the pressure instrument to the process vessel /
pipe. This is to prevent formation of liquid plugs (for air
/ gas applications). If this continuous downward gradient cannot be provided for any reason, then suitable
water separation devices must be inserted in the
pressure lines.
6.Maintenance
The instrument is inherently maintenance-free.
However, to ensure reliable operation and maximize the
operating life of the instrument, it is recommended that
the instrument, its external electrical and process connections, and external connected devices be regularly inspected, e.g.:
•Check all pressure connections for leak-tightness.
•Check the integrity of all electrical connections of the
instruments.
Inspection and test schedules depend on operating and
site conditions. The operating manuals of other equipment to which the level transmitter is connected must be
read thoroughly to ensure that all of them work correctly
when connected together.
7.Transport
The product must be protected against shock and vibration during transport. It must therefore be properly pakked, preferably in the original factory packaging,
whenever it is to be transported.
8.Service
Any defective devices or devices with missing parts
should be retourned to Fischer Mess- und Regeltechnik
GmbH. For quick service contact our service department.
Remaining medium in and on dismantled
measuring instruments may cause danger
to persons, environment and equipment.
Take reasonable precautions! Clean the
instrument thoroughly if necessary.
9.Accessories
•Wall mounting set (s. 13. Ordering Code)
•M12 connector plug with cable (s. 13. Ordering Code)
3
Page 4
10.Disposal
Protect your environment!
Use the product in accordance with relevant regulations. Please be aware of environmental consequences of disposal at the end of the product's life, and take care accordingly.
11.Specifications
General
Base mea-
suring range
Max. static
operating
pressure
Max. safe
pressure
Straight line
error (max.)°
Repeatability° %FS0.1
TC span and
offset
max.°°
° Straight-line error = nonlinearity + hysteresis; at 25 °C
°° Compensated temperature range 4 to 50 °C.
Pressure connectionsScrew clamp connectors (aluminum) for 6/4 mm or 8/6 mm tube
Materials, housing
Electrical
24 V DC
12 ... 36 V DC
4 ... 20 mA 2-wire
≤ (UB - 12 V) / 0.02 A
R
L
Connections, Materials, Mounting
Polyamide PA 6,6
Silicon, PVC, aluminium, brass
MountingRear mounting holes for back-panel mounting
Wall mounted with mounting plate
If the instrument is intended for outdoor application, we highly recommend using an adequate
protective housing (or at least a big enough shelter) as protection against UV-radiation on the
membrane keyboard and against exposure of the instrument to rain or snow.
4
Page 5
12.Dimensions (all units in mm unless otherwise stated)
Standard (rear mounting holes).............................................................................................................................>0