First Alert ZCOMBO Information Manual

INFORMATIONAL GUIDE
ZCOMBO Z-WaveTM Specification
Version: 11.0 Date: 3-Jun-20
Page 1 of 14
INFORMATIONAL GUIDE
TABLE OF CONTENTS
1.1 REVISION HISTORY ............................................................................................................................................ 3
2.1 MANUFACTURER SPECIFIC REPORT ....................................................................................................................... 4
2.2 VERSION REPORT............................................................................................................................................... 4
3.1 LIST OF SUPPORTED COMMAND CLASSES ............................................................................................................... 5
3.2 PARAMETERS SUPPORTED VIA CONFIGURATION COMMAND CLASS ............................................................................. 5
3.2.1 SuperVision report timeout ...................................................................................................................... 5
3.2.2 SuperVision retry count ............................................................................................................................ 5
3.2.3 SuperVision wait time .............................................................................................................................. 5
3.3 LIST OF SUPPORTED EVENTS OVER NOTIFICATION COMMAND CLASS ............................................................................ 6
3.4 ASSOCIATION GROUP ......................................................................................................................................... 6
3.5 SMARTSTART INCLUSION ................................................................................................................................ 7
3.6 DSK LOCATION ON THE PRODUCT ................................................................................................................ 7
4.1 LEARN MODE ................................................................................................................................................... 8
4.2 WAKE-UP NOTIFICATION .................................................................................................................................... 8
4.3 TEST ALARM ..................................................................................................................................................... 9
4.4 SMOKE ALARM ................................................................................................................................................. 9
4.5 CO ALARM ..................................................................................................................................................... 11
4.6 MALFUNCTION DETECTED ................................................................................................................................. 12
4.7 CO END-OF-LIFE(EOL) ................................................................................................................................... 12
4.8 HEARTBEAT .................................................................................................................................................... 13
4.9 BATTERY REPORT ............................................................................................................................................ 13
4.10 FACTORY RESET ............................................................................................................................................... 14
Page 2 of 14
INFORMATIONAL GUIDE
Date
Version#
Details of change
1.0
11-Oct-19
Initial version
2.0
24-Nov-19
Certification review comments resolved
3.0
4-Dec-19
Removed Basic CC, Added Association Group info, Default Wake-up interval
4.0
9-Dec-19
Added SuperVision command class and Configuration Command Class
5.0
26-Dec-19
Added Smoke silence and CO silence
6.0
29-Jan-20
Additional information for Heartbeat, Battery level, Notification_Get support
7.0
10-Feb-20
Additional information for Wake-up Notification, EOL message
8.0
14-Feb-20
Added SmartStart related information; Updated Wake-up interval parameters
9.0
19-Feb-20
Added the list of supported events over Notification Command Class
10.0
19-March-20
Updated Wake-up interval parameters
11.0
28-May-20
Added Z-Wave marketing Trademark Added DSK location chapter Added factory reset information
1 DOCUMENT DETAILS
1.1 Revision History
Page 3 of 14
INFORMATIONAL GUIDE
2 SYSTEM OVERVIEW
ZCOMBO a battery-operated smoke and carbon monoxide alarm. ZCOMBO has active smoke and CO detector sensors which constantly keeps monitoring for the level of Smoke and CO. ZCOMBO has the ZM5202 Z-Wave module to communicate over Z-Wave wireless protocol.
Figure 1: ZCOMBO device
2.1 Manufacturer Specific report
Manufacturer ID: 0x0138
Product Type ID: 0x0001
Product ID: 0x0003
2.2 Version report
Firmwar0 version: Major version number of Z-Wave firmware <1 byte>
Firmwar0 subversion: Major version number of Z-Wave firmware <1 byte>
Number of addition firmware: 1
Firmware1 version: Major version number of host firmware <1 byte>
Firmware1 subversion: Minor version number of host firmware <1 byte>
Hardware version: 0x02 <1 byte>
Page 4 of 14
INFORMATIONAL GUIDE
Command Class
Version
Required Security Class
Association
2
highest granted
Association Group Information
1
highest granted
Battery
1
highest granted
Device Reset Locally
1
highest granted
Manufacturer Specific
2
highest granted
Multi Channel Association
3
highest granted
Notification
8
highest granted
Powerlevel
1
highest granted
Security 2
1
none
Supervision
1
none
Transport Service
2
none
Version
3
highest granted
Wake-up
2
highest granted
Configuration
1
highest granted
Z-Wave Plus Info
2
none
3 Z-WAVE SPECIFIC DETAILS
3.1 List of Supported Command classes
Below is the list of supported Command Classes with the supported version and the security level.
3.2 Parameters supported via Configuration Command Class
ZCOMBO support the following parameters which are configurable via the Configuration Command Class (0x70) Ver. 1 and older versions.
3.2.1 SuperVision report timeout
ZCOMBO will send the message over SuperVision Command Class and it will wait for the SuperVision report from the Controller for the SuperVision report timeout time.
3.2.2 SuperVision retry count
If the SuperVision report is not received within the SuperVision report timeout time, the ZCOMBO will retry sending the message again. Upon exceeding the max retry, the ZCOMBO device will send the next message available in the queue.
3.2.3 SuperVision wait time
Before retrying the message, ZCOMBO will wait for the SuperVision wait time. Actual wait time is calculated using below formula,
Wait time = SuperVision wait time base-value + random-value + (attempt-count x 5 seconds)
The random value shall be a time between 100 and 1100 milliseconds
Page 5 of 14
Loading...