Technical specificaTionspRoD
SCO500B
SA511B
Operating Voltage: Two 1.5V AA Batteries
Humidity Range: 10% - 95% relative humidity (RH)
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Wiring: N/A
UPC: 0 29054 51306 9
Operating Voltage: Two 1.5V AA Batteries
C0511B
Humidity Range: 10% - 95% relative humidity (RH)
Smoke Sensor: N/A
CO Sensor: Electrochemical
Wiring: N/A
UPC: 0 29054 00291 4
Operating Voltage: Two 1.5V AA Batteries
Humidity Range: 10% - 90% relative humidity (RH)
Smoke Sensor: Photoelectric
CO Sensor: N/A
Wiring: N/A
UPC: 0 29054 00292 1
Listing: ETL to UL 217 and 2034 standards
Alarm Weight: 8.4 oz.
Individual Carton Weight: 0.66 lbs.
Master Pack Weight: 8.4 lbs.
Pallet Weight: 794.2 lbs.
12 of 5: 100 29054 51306 6
Listing: ETL to UL 2034 standard
Alarm Weight: 8.4 oz.
Individual Carton Weight: 0.66 lbs.
Master Pack Weight: 8.4 lbs.
Pallet Weight: 794.2 lbs.
I 2 of 5: 100 29054 00291 1
Listing: ETL to UL 217 standard
Alarm Weight: 8.3 oz.
Individual Carton Weight: 0.66 lbs.
Master Pack Weight: 8.4 lbs.
Pallet Weight: 794.2 lbs.
I 2 of 5: 100 29054 00292 8
SA520B
Operating Voltage: 120V AC with battery backup (Two 1.5V AA Batteries)
Humidity Range: 10% - 90% relative humidity (RH)
Smoke Sensor: Photoelectric
CO Sensor: N/A
Wiring: Quick connect plug with pigtails
UPC: 0 29054 00205 1
common Technical specs
Alarm Dimensions: 5” Dia. X 2” High
Temp Range: 40°F (4°C) to 100°F (38°C)
Audio Alarm: 85 decibel alarm
Operating Frequency: 915 MHz. FCC approved. Complies with Part 15 of the FCC Rules
RF Linking: Automatic with 65,000 security codes
Alarm Reset: Automatic when smoke and/or CO clears, depending on model
Test/Silence Feature: Electronically simulates smoke and/or carbon monoxide condition (depending on model)
Interconnections: Up to 18 units, RF or hardwired, with smoke, carbon monoxide, heat alarms and relays. Maximum 12 smoke alarms
Listing: ETL to UL 217 standard
Alarm Weight: 9.3 oz.
Individual Carton Weight: .74 lbs.
Master Pack Weight: 9.4 lbs.
Pallet Weight: 882.2 lbs.
I 2 of 5: 100 29054 00205 3
common shipping specs
Dimension 5.13”L x 2.38”W x 5.13”H 10.75”L x 7.88”W x 11.06”H
Cube 0.04 ft³ 0.54 ft³
Quantity 1 12
inDiviDual caRTon masTeR pack
palleT infoRmaTion
Cases Per Layer 22
Number of Layers 4
Cases Per Pallet 88
Units Per Pallet 1,056
Cube 54.0 ft³
Cost Effective Retrofit & Remodel Solutions
• Wireless interconnect technology eliminates the need to pull wires through existing walls
First Alert®
Technology
• Save an average of between $150 - $200** per alarm when compared to retrofitting hardwired alarms in existing walls or ceilings
• Faster job turnaround - 4X more jobs completed increases your profits
• Photoelectric sensing technology saves maintenance calls with fewer nuisance alarms.
Putting the Innovation in Renovation
When it comes to alarm renovation and retrofit projects, choices have been limited. Installing battery operated alarms and sacrificing interconnectability or investing in the time and labor to retrofit hardwired alarms have been the only options available.* Until Now! First Alert OneLink eliminates the need to pull wires through existing walls saving time, money and labor.
No matter what your renovation project, First Alert OneLink provides a cost effective solution:
Home Addition Projects:
Using the First Alert OneLink hardwired "Bridge Unit" (SA520B), simply replace one hardwired alarm in the existing section and add one to the new section. Wireless technology saves time, material and labor to connect to the existing alarm circuit. Now add standard BRK hardwired alarms as required in the new section and other First Alert OneLink battery alarms in the old section to complete the alarm safety system and bring entire home up to code. All alarms, hardwired and battery, existing and new are now interconnected.
Retrofit Projects:
Property Owners, Facility Managers and Electrical Contractors can all benefit from installing First Alert OneLink alarms for existing retrofit projects. Saving $150 - $200** per alarm and increasing job turnaround 4X are key reasons to consider First Alert OneLink alarms for all of your renovation projects.
Master
Bedroom
Blocked
Hall
Basement
Mesh Network Communication
Bedroom
®
All
RF Interconnect:
communication between alarms. 915 MHz frequency with 65,000 security codes and 3 channel frequency hopping.
Photoelectric Technology: Helps reduce nuisance alarms, especially around kitchens and baths which are more prone to nuisance alarms from cooking smoke and shower steam.
Optipath 360 Technology™:
provides 360 degrees of direct access to smoke sensor.
Spread Spectrum Horn Tone:
frequency makes it easier for elderly with normal age related hearing loss to hear horn. Sweeps through the 2200 - 3400 Hz range.
alarms include these quality innovative features:
Reliable and secure radio frequency
Patented technology
Lower and varying horn
Test/Silence Button:
Silences unwanted alarms. Two silence features - Temporarily silence low battery chirp for up to 8 hours before replacing battery or silence unwanted alarm for several minutes.
Perfect Mount:
wide rotation range to allow for perfect alignment.
Dust Cover:
Latching Features
initiating alarm even after alarm condition has subsided. Low Battery Latch: Identifies which unit is in low battery condition. Both features activate for up to 15 minutes. (excludes SA520B)
Keeps alarm clean during construction.
Tests alarm functions and battery.
mounting bracket keeps alarm secure over a
Alarm Latch: Easily identifies
SCO500B
Wireless Photoelectric
Battery Combination
Smoke & CO Alarm
Exclusive! Voice alarm with programmable location. Programmable with up to 11 locations (ex. “basement”). When alarm sounds (if programmed for basement), it will say, “Warning, Evacuate, Smoke in Basement”. If other First Alert OneLink Voice Warning alarms are located throughout the house they will also signal, “Warning, Evacuate, Smoke in Basement”.
• Add additional battery-operated First Alert Enabled Alarms to create a wireless safety network.
• 5-year limited warranty.
W IT H LO C AT IO N W IT H LO C AT IO N
Exclusive!
W I T H LO C A T I ON
Mesh Network Communication
First Alert OneLink alarms operate on a "mesh network"; a 2-way communication format that sends, receives and then re-sends the alarm signals. If the initiating alarm signal is blocked from reaching one of the alarms, the mesh network communication reroutes and re-sends the signal via the other alarms as shown in the illustration. With competitive one-way wireless communication, only the initiating alarm sends a signal which may never be received, leaving the blocked alarm deadly silent
*Local codes permitting **Note: Based on average retrofitting costs of time, material and
labor to connect to existing alarm circuit, dr ywall repairs, painting, etc. Special cases that require conduit, wire mold, concrete drilling, etc. would add additional costs and increase savings.
.
Master
Bedroom
Blocked
Hall
Basement
Bedroom
Competitive Wireless
One-Way Communication
C0511B
Wireless Battery Carbon Monoxide Alarm
• Easily add CO alarms outside bedrooms and on every level of the home to create a wireless safety network.
• 5-year limited warranty
SA511B
Wireless Photoelectric Battery Smoke Alarm
• Easily add smoke alarms to ever y bedroom to create a wireless safety network.
• 10-year limited warranty.
SA520B
Bridge Unit-Wireless Photoelectric 120-Volt AC/DC Hardwired Smoke Alarm
• Easily expand an existing interconnected 120V AC system by replacing one alarm in the series with this alarm.
• Add additional battery-operated First Alert Enabled Alarms to expand without wires.
• 10-year limited warranty.