First Alert SA300, SA305, SA303 User Manual

USER’S MANUAL
UL STANDARD 217
Model SA300
PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Smoke Alarm’s operation. If you are installing this Smoke Alarm for use by others, you must leave this manual—or a copy of it—with the end user
Printed in Mexico M08-0067-004
J1 03/07
TABLE OF CONTENTS
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Feature (Models SA303, SA305 Only) . . . . . . . . .3
If You Suspect A Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . . . .4
Locations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . .4
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . .5
Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
© 2007 BRK Brands, Inc., a subsidiary of Jarden Corporation 3901 Liberty Street Road, Aurora, IL 60504-8122
All rights reserved. Consumer Affairs: (800) 323-9005 • www.firstalert.com
All First Alert®Smoke Alarms conform to regulatory requirements, including UL217 and are designed to detect particles of combustion.
Smoke par
materials rapidly and spr paper burning in a wastebasket, or a grease fire in the kitchen.
hours befor cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each level and in every bedroom of your home.
ticles of var
Ionization technology is generally more sensitive than photoelectric technology at detecting small particles, which tend to be produced in greater amounts by flaming fires, which consume combustible
Photoelectric technology is generally more sensitive than ionization technology at detecting large particles, which tend to be produced
eater amounts by smoldering fir
in gr
e bursting into flame. Sources of these fires may include
ying number and size ar
ces of these fires may include
ead quickly
. Sour
es, which may smolder for
oduced in all fires.
e pr
FIRE SAFETY TIPS
Follow safety rules and pr materials properly. Never smoke in bed. 2) Keep matches or lighters away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload elec­cuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
trical cir grease- and debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable heaters and open flames, like candles, away from flammable materials; 8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if
e not working properly. Smoke Alarms that do not work cannot alert
they ar you to a fir an additional one in the kitchen. Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are blocked.
e. Keep at least one working fir
event hazar
dous situations: 1) Use smoking
e extinguisher on every floor
, and
Model SA303 and Model SA305
With Silence Feature
TANT!
IMPOR
BEFORE YOU INSTALL THIS SMOKE ALARM
IMPORTANT! Read “Recommended Locations for Smoke Alarms” and “Locations to Avoid for Smoke Alarms” before beginning. This unit mon­itors the air, and when smoke reaches its sensing chamber, it alarms. It can give you more time to escape before fire spreads. This unit can ONLY give an early warning of developing fires if it is installed, main­tained and located where smoke can reach it, and where all residents can hear it, as described in this manual. This unit will not sense gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or electrical? Different Smoke Alarms provide different types of protection. See “About Smoke Alarms” for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on every level of your home, in every bedroom, and in every bedroom hallway or separate sleeping area. See “Recommended Locations For Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to escape. It can only sound an alarm once smoke reaches the sensor. See “Limitations of Smoke Alarms” for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family home. It alone will not meet requirements for boarding houses, apartment buildings, hotels or motels. See “Special Compliance Considerations”
• This unit will not alert hearing impaired residents. It is recom­mended that you install special units which use devices like flashing strobe lights to alert the hearing impaired.
Do not connect this unit to any other alarm or auxiliary
• device. It is a single-station unit that cannot be linked to other devices. Connecting anything else to this unit may pr
om working pr
fr
• Unit will not operate without battery power. The Smoke Alarm cannot work until you install the battery in the correct position (Match “+” to “+” and “-” to “-”).
• This Smoke Alarm has a battery drawer which resists closing unless a batter operate without a battery.
• Do not install this unit over an electrical junction box. Air cur­rents around junction boxes can prevent smoke from reaching the sensing chamber and prevent the unit from alarming. Only AC powered units are intended for installation over junction boxes.
• Do not stand too close to the unit when the alarm is sounding. It is loud to wake you in an emergency. Exposure to the horn at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
• sensing chamber and pr
.
Models SA300, SA303,
SA305
for details.
.
operly
y is installed. This warns you the unit will not
event the unit fr
om operating pr
event it
operly
.
1
HOW TO INSTALL THIS SMOKE ALARM
1
2
3
2
5
4
3
+
Locking Pin
THE P
ARTS OF THIS SMOKE ALARM
m Base
Alar
1. Battery Compartment est button (Model SA300)
2. T
Test/Silence button (Models
2.
SA303 and SA305)
This unit is designed to be mounted on the ceiling, or on the wall if necessary.
NOT attach this Alarm to an electrical junction box.
DO Attachment to an electrical box may impair the Alarm’s operation. Attach dir
ools you will need:
T
1. Remove the mounting bracket from the Smoke Alarm base. Hold the
2.
3.
4. Insert the plastic screw anchors (in the plastic bag with screws) into
5. Tighten the screws (provided) into the screw anchors.
ectly to wallboard or flat wall or ceiling surface.
FOLLOW THESE SIMPLE STEPS!
• Pencil • Drill with 3/16” (5 mm) drill bit
• Hammer • Standard Flathead screwdriver
mounting bracket against the ceiling (or wall) and make a mark at the center of each of the mounting slots with a pencil.
Put the unit where it won’t get covered with dust when you drill the mounting holes.
Using a 3/16” (5 mm) drill bit, drill a hole through each pencil mark.
the holes. Tap the screw anchors gently with a hammer, if necessary, until they are flush with the ceiling or wall.
ts of This Unit
The Par
1. Mounting Bracket
2. Mounting Slots and Scr
ews
3. Locking Pins (break out of bracket)
4. Latch to Open Battery Compartment
5. Swing-Out Battery Compartment To remove the mounting bracket
from the Smoke Alarm base, hold the Smoke Alarm base firmly and twist the mounting bracket counterclockwise.
6. Activate the battery. With the battery compartment open, install the battery so the terminals on the battery match the terminals on the Smoke Alarm. Match “+” to “+” and “-” to “-.” Push the battery in until it snaps in secur and cannot be shaken loose.
If the battery is not snapped in completely, the unit cannot receive battery power the battery—this is normal.
7.
Position the base of the Smoke Alarm over the mounting bracket and tur Turn the Smoke Alarm clockwise (right) until the unit is in place.
. The Smoke Alarm may beep briefly when you install
n. The Alarm can be positioned over the bracket every 60°.
ely
8. Test the Smoke Alarm. See “Weekly Testing.”
OPTIONAL LOCKING FEATURES
The locking features are designed to discourage unauthorized removal of the battery or Alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or Alarm removal is not a concern.
These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.
Tools you will need: • Needle-nose pliers or utility knife • Standard Flathead screwdriver. Both locking features use locking pins, which are molded into the mounting bracket. Using needle nose pliers or a utility knife,
remove one or both pins from the mounting bracket, depending on how many locking features you want to use.
To permanently remove either lock, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you have installed the battery and tested the unit.
1. Push and hold test button until the alarm sounds: 3 beeps, pause, 3 beeps, pause.
If the unit does not alarm during testing, DO NOT lock the batter Install a new battery and test again. If the Smoke Alarm still does not alarm, replace it immediately.
2. Using needle-nose pliers or a utility knife, detach one locking
om the mounting bracket.
pin fr
3. Push the locking pin through the hole near the battery drawer on the back of the Smoke Alarm.
y compar
tment!
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers, detach one locking pin from mounting bracket. Insert the locking pin into the lock located on the pivoting hinge of the
2. battery door.
3. When you attach the Smoke Alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.
TO UNLOCK THE BATTERY COMPARTMENT
1. Remove the Smoke Alarm from the mounting bracket. If the unit is locked to the bracket, see the section “To Unlock the Mounting Bracket.”
2. Insert a flathead screwdriver under the head of the locking pin, and gently pry it out of the battery compartment lock. (If you plan to relock the battery compartment, save the locking pin.)
o relock the battery compartment, close the battery door and
T
3. reinsert locking pin in lock.
4. Reattach the Smoke Alarm to the mounting bracket.
When replacing the battery, always test the Smoke Alarm before relocking the battery compartment.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket.
2. Pry the Smoke Alarm
2
om the
away fr bracket by turning both the screwdriver and the Smoke Alarm
clockwise
counter (left) at the same time.