Photoelectric alarms are generally more effective at detecting
slow, smoldering fires that smolder for hours before bursting into
flame. Sources of these fires may include cigarettes burning in
couches or bedding. Ionization alarms are generally more effective at detecting fast, flaming fires that consume combustible
materials rapidly and spread quickly. Sources of these fires may
include flammable liquids or paper burning in a waste container.
However, both types of alarms provide adequate detection of
both types of fires.
If you desire the earliest detection of both smoldering fires and
fast flaming fires, you should install smoke alarms that combine
both photoelectric and ionization sensing technologies in one
unit.
SMOKE ALARM FEATURES
This smoke alarm is powered by 120V AC (0.05 Amps, 60Hz) and a
protection in the event of a power failure or a drained battery.
Unique power connector prevents interconnection with
•
incompatible smoke alarms or security systems.
This smoke alarm may be interconnected with as many as 11 addi-
•
tional Firex model AD, ADC, PAD, FADC and FPAD smoke alarms,
and/or as many as 6 Firex model ADH heat alarms for a total of not
more than 18 interconnected devices.
Optional tamper-resist feature can serve as a safeguard against
•
tampering.
Unique “battery missing” lockout. The smoke alarm battery door
•
will not close if a battery is not in the battery pocket.
Separate green and red LEDs indicate that the smoke alarm is
•
receiving AC power, working under normal operation, or in alarm.
Loud alarm horn—85 decibels at 10 feet—sounds to alert you
•
to an emergency.
This alarm incorporates the internationally recognized horn signal
•
for evacuation. During alarm mode, the horn produces three short
beeps followed by a 2 second pause and then repeats. This pattern is somewhat different than the previous alarm sound, which
continually beeped.
Test button checks smoke alarm operation.
•
IMPORTANT SAFETY INFORMATION
PLEASE READ AND SAVE THESE
INSTRUCTIONS
!
This smoke alarm requires constant 120-volt, AC power
•
AND a working 9-volt battery to operate properly. This
smoke alarm WILL NOT work if AC power is not connected or
has failed or been interrupted for any reason AND the battery is
removed, drained or improperly connected. DO NOT use any
other kind of battery except as specified in this manual. DO
NOT connect this smoke alarm to any other type of smoke
alarm or auxiliary device, except those listed in this manual.
DO NOT remove or disconnect battery or turn off AC power to
•
quiet unwanted alarms. This will remove your protection. Open
windows or fan the air around smoke alarm to silence it.
The Push-to-Test button accurately tests all smoke alarm
•
functions. DO NOT use any other test method. Test smoke
alarm weekly to ensure proper operation.
This smoke alarm should be installed only by a licensed,
•
qualified electrician. Observe and follow all local and national
electrical and building codes for installation.
This smoke alarm IS NOT designed to be the PRIMARY
•
protection for buildings that require complete fire alarm
systems. Buildings of this type include hotels, motels, dormito-
ries, hospitals, nursing homes, and group homes. This is true
even if they were once single family homes. However, this
WARNING
1
smoke alarm MAY be used inside individual rooms as
SUPPLEMENTAL protection.
Smoke alarms must not be used with detector guards
•
unless the combination of alarm and guard has been evaluated
and found suitable for that purpose.
Install a smoke alarm in every room and on every level of the
•
home. Smoke may not reach the smoke alarm for many reasons.
For example, if a fire starts in a remote part of the home, on another
level, in a chimney, wall, roof, or on the other side of a closed door,
smoke may not reach the smoke alarm in time to alert household
members. A smoke alarm will not promptly detect a fire EXCEPT in
the area or room in which it is installed.
Interconnected smoke alarms installed in every room and
•
on every level of the household offer maximum protection.
The National Fire Protection Agency (NFPA) recommends
interconnecting smoke alarms so that when one smoke alarm
senses smoke and sounds its alarm, all others will sound as
well. Do not interconnect smoke alarms from one individual
family living unit to another. Do not connect this smoke alarm
to any other type of alarm or auxiliary device.
Smoke alarms may not alert every household member every
•
time. The alarm horn is loud in order to alert individuals to a
potential danger. However, there may be limiting circumstances
where a household member may not hear the alarm (i.e., outdoor or indoor noise, sound sleepers, drug or alcohol usage, the
hard of hearing, etc.). If you suspect that this smoke alarm may
not alert a household member, install and maintain specialty
smoke alarms. Household members must hear the alarm’s
warning sound and quickly respond to it to reduce the risk of
damage, injury, or death that may result from fire. If a household
member is hard of hearing, install special smoke alarms with
lights or vibrating devices to alert occupants.
Smoke alarms can sound their alarms only when they detect
•
smoke. Smoke alarms detect combustion particles in the air.
They do not sense heat, flame, or gas. This smoke alarm is
designed to give audible warning of a developing fire. However,
many fires are fast-burning, explosive, or intentional. Others are
caused by carelessness or safety hazards. Smoke may not reach
the smoke alarm QUICKLY ENOUGH to ensure safe escape.
Smoke alarms have limitations. This smoke alarm is not fool-
•
proof and is not warranted to protect lives or property from fire.
Smoke alarms are not a substitute for insurance. Homeowners
and renters should insure their lives and property. In addition, it
is possible for the smoke alarm to fail at any time. For this rea-
son, you must test the smoke alarm weekly and replace
every 10 years.
SMOKE ALARM PLACEMENT
Invensys Controls Americas recommends complete coverage protection achieved by installing a smoke alarm in every room of your
home. The National Fire Protection Association’s (NFPA) minimum
requirement, as stated in Standard 72, Chapter 2, reads as follows:
“2-2.1.1.1 Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on
each additional story of the family living unit including basements
and excluding crawl spaces and unfinished attics. In new construction a smoke detector also shall be installed in each sleeping room.”
Chapter 2 also reads as follows:
“2-2.2.1 In new construction,
where more than one smoke
detector is required by 2-2.1,
they shall be so arranged that
operation of any smoke detector
shall cause the alarm in all
smoke detectors within the
dwelling to sound.”
The NFPA, 1993 Edition,
Appendix A further states:
“The required number of smoke
detectors may not provide reliable
early warning protection for those
areas separated by a door from
the areas protected by the
required smoke detectors. For
this reason, it is recommended that the householder
consider the use of additional
smoke detectors for those
TV ROOM
areas for increased protection. The additional areas
BEDROOM
include: basement, bedrooms, dining room, furnace room, utility room, and hallways not
protected by the required smoke detectors.”
Also, as required by the California State Fire Marshal:
“Early warning fire detection is best achieved by the installation
of fire detection equipment in all rooms and areas of the house-
2
DINING
ROOM
LIVING ROOM
BEDROOMBEDROOM
LIVING
ROOM
BASEMENT
DINING
ROOM
LIVING ROOM
KITCHEN
BEDROOM
BEDROOM
BEDROOM
HALL
DINING
ROOM
KITCHEN
BEDROOM
BEDROOM
hold as follows: A smoke detector installed in each separate
sleeping area (in the vicinity, but outside the bedrooms), and heat
or smoke detectors in the living rooms, dining rooms, bedrooms,
kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages.”
FOR BEST PROTECTION, WE
RECOMMEND THAT YOU INSTALL A SMOKE
ALARM IN EVERY ROOM.
In addition, we recommend that all smoke alarms be interconnected.
Typical Efficiency
Home (Apartment)
Install a smoke alarm on the
•
ceiling or wall closest to the
sleeping area.
SLEEPING
AREA
EFFICIENCY APARTMENT
KITCHEN
LIVING
AREA
BEDROOM
KITCHENLIVING ROOM
BATH
MOBILE
HOME
Typical Mobile Home
NOTE: For mobile homes built before 1978, install smoke alarms on
an inside wall between 4 and 12 inches from the ceiling. (Older
mobile homes have little or no insulation in the ceiling.) This is
especially important if the ceiling is unusually hot or cold.
Install a smoke alarm inside each bedroom and in the hallway
•
outside each separate sleeping area.
Typical Single-Story Home
Install a smoke alarm on the ceiling
•
or wall inside each bedroom and in
the hallway outside each separate
sleeping area. If a bedroom area
hallway is more than 30 feet long,
install a smoke alarm at each end.
If there is a basement:
Install a smoke alarm on the base-
•
BEDROOM
BASEMENT
KITCHEN
BED-
ROOM
FURNACE
BATH
ROOOM
ment ceiling at the bottom of the
stairwell.
Typical Two-Story or Split Level
BEDROOMBEDROOMBATH
LIVED-IN
ATTIC
Home
Install a smoke alarm on the ceil-
•
ing or wall inside each bedroom
and in the hallway outside each
separate sleeping area. If a bedroom area hallway is more than
30 feet long, install a smoke alarm
LIVING AREA
KITCHEN
at each end.
Install a smoke alarm at the top of
•
a first-to-second floor stairwell.
BASEMENT
If there is a basement:
Install a smoke alarm on the basement ceiling at the bottom
•
FURNACE
ROOM
TWO STORY
of the stairwell.
KEY
• Smoke Alarm (Ionization)
∆ Photoelectric Smoke Alarm or Ionization Smoke Alarm with
False Alarm Control
IMPORTANT SMOKE ALARM
PLACEMENT AND EXCEPTION
INFORMATION
Install a smoke alarm as close to
•
the center of the ceiling as possi-
ble. If this is not practical, mount
ACCEPTABLE HERE
no closer than 4 inches from a
wall or corner. Also, if local codes
allow, install smoke alarms on
walls, between 4 and 12 inches
from ceiling/wall intersections.
Install a minimum of two smoke alarms in every home, no mat-
•
ter how small the home. New construction codes require a min-
imum of two interconnected smoke alarms in newly built
homes.
Install a smoke alarm in each room
•
that is divided by a partial wall
(either coming down from the ceiling at least 24 inches, or coming up
STUB WALL
from the floor).
3
CEILING
NEVER HERE
TOP OF DETECTOR
ACCEPTABLE HERE
SOFFIT
4 IN
(0.1m )
24"
(0.1m )
MINIMUM
SIDE
WALL
4 IN
12 IN
(0.3 m )
MAXIMUM