Firex KF10, KF10LL, KF10R, KF20, KF20LL User Manual

...
SMOKE ALARM DESCRIPTION
Model KF10, KF10LL Ionisation 230V AC smoke alarm with 9V
battery back-up and Hush Button
M
odel KF10R Ionisation 230V AC smoke alarm with recharge-
a
ble battery backup and Hush Button
b
attery back-up with Hush Buttonl
M
odel KF20R Optical 230V AC smoke alarm with rechargeable
b
attery back-up and Hush Button
SMOKE ALARM FEATURES
Interconnects with up to 23other models, KF1, KF1R,KF2, KF2R, KF3, KF3R, KF10, KF10LL,KF10R,KF20, KF20LL,KF20R, KF30, KF30LL, KF30R, 4870, 4881, 4973,4985, 4892, 4899,1SFW, 1SFWR, 2SFW, 2SFWR,3SFW, 3SFWR, and 4MCO and4MDCO Mains CO alarms.Unique power connector prevents interconnection with incompatible smoke alarms or security systems.
Tamper-resist bracket quickly snaps into place and serves as a safeguard against tampering.
Multi-purpose green and red LEDs indicate that the smoke alarm is receiving AC power, working under normal operation, in alarm, or under Hush Button.
Loud alarm horn—85 decibels at 3 metres (10 feet)—sounds to alert you of an emergency.
• Test button checks smoke alarm operation.
• All modelsfeature Hush Button, which, when activated, quiets unwanted alarms for up to 9 minutes.
Models KF10, KF10LL, KF20 and KF20LL will not attach to the mounting bracket if a battery is not in the battery pocket. These models will also sound a short beep about once a minute if the battery is weak or improperly con­nected.
Models KF10R , KF20R , KF10LL and KF20LL have lithium batteries that will last the life of the alarm and a tamper-proof locking screw option.
Models KF10R and KF20R include permanent rechargeable lithium batteries.
Operating temperature: 0°C to 40°C
Operates up to 93% humidity (non-condensing)
IMPORTANT SAFETY INFORMATION
PLEASE READ AND SAVE THESE
INSTRUCTIONS
W A R N I N G
DO NOT paint or cover the smoke alarm with tape.
This smoke alarm should be out of the reach of children.
AC smoke alarms require constant 230V AC, 50Hz power to operate properly. Mains-powered smoke alarms WILL NOT work if AC power is not
connected or has failed or been interrupted for any reason. Models KF10, KF10LL and KF20, KF20LL require a working 9-volt battery to operate prop­erly in the event of a power failure. Models KF10R and KF20R require a minimum of 2 full days under mains power to reach full backup capacity. DO NOT use any other kind of battery except as specified in this user guide. DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device, except those listed in this user guide.
DO NOT remove or disconnect battery or turn off AC power to quiet unwanted alarms. This will remove your protection. Open windows or fan the air
around smoke alarm to silenceit. KF10,KF10LL, KF10R, KF20, KF20LL and KF20R smokealarmsfeature a Hush Button which, when activated, will quiet unwanted alarms for up to 9 minutes.
1
User Guide
PLEASE READ AND SAVE
INSTALLER: Please leave this user guide with the product.
KF10 KF10LL KF10R
Ionisation
KF20 KF20LL KF20R
Optical
E
N14604:2005
L
ICENSE NO. KM 524754
0086-CPD-535595
14
EN 14604:2005
!
1374-7205-00(KF10_KF20_KF10R_KF20R)_EN_V4:_ 2014.11.20 10:16 AM Page 1
T
he Push-to-Test button accurately tests all smoke alarm func-
t
ions. DO NOT use any other test method. Test smoke alarm week-
l
y to ensure proper operation.
This smoke alarm should be installed only by a qualified e
lectrician.
This smoke alarm is designed to be used inside a single family h
ousehold only. In multi-family buildings, each individual living unit
s
hould have its own smoke alarms. Do not install in non-residential
b
uildings or places which house many people like hotels, motels, dormitories, hospitals, nursing homes, or group homes of any kind. T
his smoke alarm is not a substitute for a complete alarm system.
Install a smoke alarm in every room and on every level of the home.
S
moke may not reach the smoke alarm for many reasons. For example,
i
f a fire starts in a remote part of the home, on another level, in a chim-
n
ey, wall, roof, or on the other side of a closed door, smoke may not reach the smoke alarm in time to alert household members. A smoke a
larm will not promptly detect a fire EXCEPT in the area or room in w
hich it is installed.
Interconnected smoke alarms installed in every room and on every l
evel of the household offers maximum protection. We recommend
i
nterconnecting smoke alarms so that when one smoke alarm senses
s
moke and sounds its alarm, all others will sound as well. Do not i
nterconnect smoke alarms from one individual family living unit to another. Do not connect this smoke alarm to any other type of alarm or auxiliary device.
S
moke alarms may not alert every household member every time.
T
he alarm horn is loud in order to alert individuals of a potential danger. However, there may be limiting circumstances where a household member may not hear the alarm (i.e. outdoor or indoor noise, sound sleepers, drug or alcohol usage, the hearing impaired, etc.). If you suspect that this smoke alarm may not alert a household m
ember, install and maintain specialty smoke alarms. Household
m
embers must hear the alarm’s warning sound and quickly respond to
i
t to reduce the risk of damage, injury, or death that may result from
f
ire. If a household member is hearing impaired, install special smoke
alarms with lights or vibrating devices to alert occupants.
Smoke alarms can only sound their alarms when they detect smoke. Smoke alarms detect combustion particles in the air. They do
not sense heat, flame, or gas. This smoke alarm is designed to give audible warning of a developing fire. However, many fires are f
ast-burning, explosive, or intentional. Others are caused by
c
arelessness or safety hazards. Smoke may not reach the smoke a
larm QUICKLY ENOUGH to ensure safe escape.
Smoke alarms have limitations. This smoke alarm is not fool-proof and is not warranted to protect lives or property from fire. Smoke alarms are not a substitute for insurance. Homeowners and renters should insure their lives and property. In addition, it is possible for the smoke alarm to fail at any time. For this reason, you must test the
smoke alarm weekly and replace every 10 years.
SSMMOOKKEE AALLAARRMM PPLLAACCEEMMEENNTT
It is recommended to achieve complete coverage protection by installing a smoke alarm in every room of your home.
At a minimum, smoke alarms shall be installed outside or inside all bedrooms and on each additional storey of the family living unit including basements, and con­verted loft spaces. Any home requires a minimum of two smoke alarms.
Typical Single Storey Home
Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 9 m long, install a smoke alarm at each end.
Typical Two-Storey Home
Install a smoke alarm on the ceiling inside each bedroom and in the hall­way outside each separate sleeping area.
If a bedroom area hallway is more than 9 m long, install a smoke alarm at each end.
Install a smoke alarm at the top and bottom of a first-to-second floor stairwell.
2
KITCHEN
F
AMILY ROOM
BEDROOM
BEDROOM
BEDROOM
FIREPLACE
DINING
ROOM
ATTIC OFFICE
BEDROOM BEDROOM
KITCHEN
LIVING ROOM
GARAGE
DINING ROOM KITCHEN
LIVING ROOM
BEDROOM
BEDROOM BEDROOM
Key
Ionisation Alarm
Heat Alarm
Optical Alarms
1374-7205-00(KF10_KF20_KF10R_KF20R)_EN_V4:_ 2014.11.20 10:16 AM Page 2
IIMMPPOORRTTAANNTT SSMMOOKKEE AALLAARRMM PPLLAACCEEMMEENNTT AANND
D
EEXXCCEEPPTTIIOONN IINNFFOORRMMAATTIIOONN::
I
nstall a smoke alarm as close to the centre
o
f the ceiling as possible. If this is not p
ractical, mount no closer than 30cm (12 inches) from a wall or corner. Also, if local c
odes allow, install smoke alarms on walls, 3
0 cm (12 inches) from ceiling/wall intersec­t
ions.
In
stall a minimum of two smoke alarms in every home, no matter how small the h
ome. Any size home requires fitting a
m
inimum of two smoke alarms.
Install a smoke alarm in each room that is d
ivided by a partial wall (either coming
d
own from the ceiling at least 20 cm (8
inches), or coming up from the floor).
In
stall smoke alarms on peaked, cathedral, o
r gabled ceilings 1 m from the highest
point (measured horizontally).
In
stall a smoke alarm in lived-in attics or a
ttics which house electrical equipment like
furnaces, air conditioners, or heaters.
L
ocations to be Avoided (Smoke Alarms)
Do not site within 3m of a steam source e.g. kitchen/bath room or garage.
Do not site within 1m of dimmer control cabling or cable alarm into any such cobling.
Do not site adjacent to any heat source.
Do not site within 300m (12”) of any lights fixure and 300mm from any wall.
Do not site near fluorescent lights; electronic noise may cause n
uisance alarms.
I
n locations where temperature may fall below 0°C (40°F), or above
4
0°C (104°F).
In areas with relative humidity (RH) above 93% (non-condensing).
In very dusty/dirty/insect laden areas.
Any location where the free flow of smoke to the alarm could be interrupted (e.g. next/above a door/air vent/heater/air-con unit).
Areas where routine maintenance or operating hush/test button is difficult (e.g. top of stairwells).
Siting should be in accordance with the current Building Regulations and/or BS5839 Pt6/current I.E.E. Regulations.
CAUTION: Alarm should not be exposed to dripping or splashing.
HOW TO INSTALL
THIS SMOKE ALARM
DANGER: ELECTRICAL SHOCK HAZARD. Turn off
power at the main consumer unit or cir­cuit breaker by removing the fuse or switching the circuit breaker to the OFF position and securing it.
WARNING: Mains operated smoke alarms should be
installed by a qualified electrician in accordance with the Regulations for Electrical Installations published by the Institution of Electrical Engineers (BS). Failure to install this smoke alarm cor­rectly may expose the user to shock or fire hazards.
WARNING: The smoke alarm, its associated supply
and interconnect wiring must be installed in accordance with BS 7671 published by the Institution of Electrical Engineers.
WARNING: If a Firex Rechargeable alarm is replacing
an earlier non rechargeable model, the new cable harness with 4 strands must be used. Using the old 3 strand harness will not allow new rechargeable alarm to charge it's batteries.
Install smoke alarm on ceiling, standard electrical box, or surface
mounting pattress.
1. Align mounting plate with mounting holes of standard electrical box or surface mounting pattress. For siting on ceiling, use mounting plate as template to mark holes. Drill holes and insert supplied screw plugs into holes until flush with ceiling.Ceiling mounting is always preferable over wall mounting.
2. Secure mounting plate to electrical box, pattress or ceiling. (Diagram illustrates fixing mounting plate to electrical box.)
3. Connect blue cable from connector plug of smoke alarm to neutral
3
20cm
STUB WALL
SOFFIT
30cm
30cm
CEILING
SIDE WALL
ACCEPTABLE HERE
NEVER HERE
TOP OF DETECTOR
ACCEPTABLE HERE
1M
PEAKED CEILING
!
!!!
!
1374-7205-00(KF10_KF20_KF10R_KF20R)_EN_V4:_ 2014.11.20 10:16 AM Page 3