, DEDI-
3. Using a suitably-rated connector (supplied with Firex Pattress models) connect the line supply to the brown lead of the connector plug.
4. If interconnecting is desired, connect the orange of the connector plug to the designated interconnect conductor of the household cable. See note “INTERCONNECTING HEAT ALARMS”.
5. Insert the completed connector block onto the mounting pins of the Firex Pattress or recess into the electrical accessory box.
6. Pass the connector plug through the mounting plate of the heat alarm, align slots and fasten mounting plate securely to the Firex Pattress or electrical accessory box.
NOTE: If this is to be a single-station heat alarm, cover the orange wire
with electrical tape and tuck it into the electrical box or pattress.
7. Open the battery compartment door.
8. Connect a new, healthy 9V DC battery to the battery connector inside the battery compartment. Be sure the battery is securely connected. The heat alarm may beep briefly when the battery is installed.
9. Close the battery compartment door, snapping it into place.
10. Attach the connector plug to the pins on the back of the heat alarm. The plug will only fit one way, and will snap into place.
11. Gently tug the connector to be sure it is attached securely.
12. Position the heat alarm on the mounting plate and turn it clockwise to lock it into place.
13. Test the heat alarm to verify the 9V DC battery back-up. See “TESTING THE HEAT ALARM”.
NOTE: The heat alarm will not mount to the plate if the battery is not
in place.
14. Turn on the power to the heat alarm circuit at the main distribution board.
15. Test the heat alarm for AC operation. See “TESTING THE HEAT ALARM”.
CEILING
LINE
INTERLINK
NEUTRAL
BROWN
ORANGE
BLUE
FIREX MODEL H230
STANDARD ELECTRICAL BOX OR
(MODEL PAT OR PATR) PATTRESS
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
GUARANTEE
Maple Chase Company (the “Company”) guarantees this product (except for the battery) to be free from defects in material and workmanship under normal use and service (“Defects”) for a period of six (6) years from the date of purchase (the “Guarantee Period”). Should any Defects be discovered within the Guarantee Period, the Company will, at its option, repair or replace the defective product provided that: (a) it is returned during the Guarantee Period with postage prepaid and with proof of pur­chase date to the address shown below and (b) the Company verifies that the claim is proper. This Guarantee does not cover damage resulting from accident, improper installation, maintenance or repair, misuse, abuse or product modification. This Guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This Guarantee is offered as an extra ben­efit and does not affect your statutory rights as a consumer.
Return units, postage prepaid, to your local distributor. For information on your local distributor, contact:
Maple Chase Company
2820 Thatcher Road
Downers Grove, IL 60515-4040 USA
Tel +1-630-719-5500
In the U.K and the Republic of Ireland, contact:
Sensotec Europe Ltd.
Unit 7, Bala Industrial Estate
Bala, Gwynedd LL23 7NL
Tel 01678 520022
PROBLEM SOLUTION Heat alarm beeps about 1. Turn off AC power and
once a minute. replace battery. See
“Battery Replacement” in the “MAINTENANCE AND CLEANING” section.
Heat alarm sounds 1. Hire an electrician to move unwanted alarms. heat alarm to a new location.
See the “HEAT ALARM PLACEMENT” and “DO NOT INSTALL HEAT ALARMS” sections of this manual.
Interconnected heat alarms 1. Press and hold button for at do not sound when system least three seconds after the is tested. first unit sounds.
2. Turn off AC power or circuit breaker and check the interconnect wiring. See “INTERCONNECTING HEAT ALARMS” section of this manual.