Firewerks VFRMV24NA, VFRMV18PA, VFRMV24PA Owner's Operation And Installation Manual

For more information, visit www.desatech.com
WARNING: If the information in this manual is not fol-
lowed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
UNVENTED (VENT FREE) GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
VFRMV18NA, VFRMV18PA VFRMV24NA, VFRMV24PA
Vent-free Models Also Design-Certied
As Vented Decorative Appliances
www.desatech.com
114745-01D2
SAFETy INFORMATION
TAbLE OF CONTENTS
Safety Information ............................................... 2
Product Identication ........................................... 5
Local Codes......................................................... 5
Unpacking............................................................ 5
Optional Remote Control Accessories ................. 5
Product Features ................................................. 5
Air For Combustion and Ventilation ..................... 6
Installation ........................................................... 8
Operating Heater ............................................... 16
Inspecting Burners............................................. 19
Cleaning and Maintenance ................................ 20
Wiring Diagram .................................................. 21
Troubleshooting ................................................. 22
Specications .................................................... 26
Replacement Parts ............................................ 26
Service Hints ..................................................... 26
Technical Service............................................... 26
Accessories ....................................................... 26
Illustrated Parts Breakdown and Parts List........ 28
Warranty Information ........................... Back Cover
WARNING: Improper in­stallation, adjustment, al-
teration, service or main-
tenance can cause injury or property damage. Refer
to this manual for correct
installation and operation­al procedures. For assis-
tance or additional infor-
mation consult a qualied installer, service agency or the gas supplier.
WARNING: This appli-
ance is for installation
only in a solid-fuel burn­ing masonry or UL127 factory-built fireplace
or in a listed ventless
rebox enclosure. It is design-certied for these
installations in accor-
dance with ANSI Z21.11.2. Exception: Do not install this appliance in a fac­tory-built replace that in-
cludes instructions stat-
ing it has not been tested or should not be used with unvented gas logs.
WARNING: This is an un-
vented gas-red heater. It uses air (oxygen) from
the room in which it is
installed. Provisions for adequate combustion
and ventilation air must
be provided. Refer to Air for Combustion and Ven­tilation section on page 6
of this manual.
This appliance may be in-
stalled in an aftermarket,*
permanent ly located, manufactured (mobile) home, where not prohib­ited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
www.desatech.com
114745-01D 3
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op­erate or service this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced.
Some people are more affected by carbon mon-
oxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the inuence of alcohol and those at high altitudes.
Natural & Propane/LP Gas: Natural & Propane/LP
gas are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.
WARNING: Any change to this log set or its controls can be dangerous.
WARNING: Do not use a blow­er insert, heat exchanger insert or other accessory not approved for use with this appliance.
WARNING: This appliance is equipped with (natural or pro­pane/LP) gas. Field conversion is not permitted.
SAFETy INFORMATION
Continued
WARNING: Do not allow fans
to blow directly into the replace. Avoid any drafts that alter burner ame patterns. Ceiling fans can create drafts that alter burner ame patterns. Altered burner patterns can cause sooting.
WARNING: Do not place log scraps or lava rocks on burner
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the heater.
Heater assembly becomes very hot when running heater. Keep
children and adults away from
hot surface to avoid burns or clothing ignition. Heater will
remain hot for a time after shut-
down. Allow surface to cool before touching.
Carefully supervise young chil-
dren when they are in the room
with appliance. When using the
hand-held remote accessory,
keep selector switch in the OFF position to prevent children from turning on burners with remote.
You must operate this heater with a replace screen in place. Make sure replace screen is closed before running heater.
www.desatech.com
114745-01D4
Keep the appliance area clear and free from combustible ma­terials, gasoline and other am­mable vapors and liquids.
Solid fuels shall not be burned in a replace in which an unvented room heater installed.
Children and adults should be alerted to the hazard of high tem­perature and should stay away to avoid burns or clothing ignition.
1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) in­side the structure.Locate propane/LP supply tank(s) outdoors (propane/LP units only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call
the re department
4. This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appliance. See Installing Damper Clamp Ac- cessory for Vented Operation, page 12. This gas log set may not be installed as a vented
appliance in a bedroom or bathroom in the
Commonwealth of Massachusetts.
5. Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creosote, ashes and loose paint by a qualied chimney cleaner. Creosote will ignite if highly heated. Inspect chimney ue for damage. If dam­aged, repair ue before operating appliance.
6. If replace has glass doors, never operate with glass doors closed, If you operate heater with doors closed, heat buildup inside replace will cause glass to burst. Also if replace opening has vents at the bottom, you must open the vents before operating heater.
SAFETy INFORMATION
Continued
7. To prevent the creation of soot, follow the instruc­tions in Cleaning and Maintenance, page 20.
8. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within the burner box or on adjacent walls and furniture.
9. This heater needs fresh, outside air ventilation to run properly this heater has an Oxygen De­pletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if enough fresh air is not available. See Air Combustion and Ventilation page 6. If the heater keeps shutting off, see Troubleshooting, page 22.
10. Do not run heater
• where ammable liquids or vapors are used
or stored
• under dusty conditions
11. Do not use heater to cook food or burn paper or other objects.
12. Do not use heater if any part has been exposed to or under water. Immediately call a qualied service technician to inspect the room heater
and to replace any part of the control system and
any gas control which has been under water.
13. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime­size or larger).
14. Turn heater off and let cool before servicing, installing or repairing. Make sure the selector switch is in the OFF position. Only a quali­ed service person should install, service or repair heater.
15. Make sure the selector switch is in the OFF position when you are away from home for long periods of time.
16. Remote-ready heaters shall not be connected to any external electrical source.
17. Operating heater above elevations of 4,500 feet may cause pilot outage.
18. To prevent performance problems, do not use propane/LP tank(s) of less than 100 lb. capac­ity (propane/LP units only).
19. Provide adequate clearances around air openings.
WARNING: Failure to posi-
tion the parts in accordance with these diagrams or failure to use only parts specically approved with this heater may result in property damage or personal injury.
www.desatech.com
114745-01D 5
PRODUCT
IDENTIFICATION
Figure 1 - Product Identication
Log Set
Chassis Assembly
Lava Rock
LOCAL CODES
Install and use the heater with care. Follow all local codes. In the absence of local codes, use the
latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54*
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Battery march park Quincy, MA 02269
Note: Where listed vented decorative logs are required, thermostat operations is not permitted. The installation of appliances designed for manu­factured home (U.S. only) or mobile home instal­lation must conform with the Standard CAN/CSA Z240 MH, Standard, Title 24 CFR, Part 3280, in the United States or when such a Standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A Manufactured Home Installations Standard.
UNPACkING
CAUTION: Do not remove the
data plates from the grate as­sembly. The data plates contain important warranty and safety information.
1. Re move log set ass embly from carton. Note: Do not pick up assembly by logs. This could damage the unit. Always handle assembly by grate.
2. Remove all protective packaging applied to log set for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought appliance.
OPTIONAL REMOTE
CONTROL ACCESSORIES
There are four optional remote controls that can be purchased separately:
Wall switch Hand-held ON/OFF remote
Wall thermostat Hand-held thermostat remote
See Accessories, page 26
The wall thermostat or hand-held thermostat may not be used where vented decorative listings is required.
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic ames and glowing coals. This heater is designed for vent-free operation with ue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening the ue damper.
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple­tion Sensing (ODS) safety shut off system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system re­quires no matches, batteries or other sources to light heater.
State of Massachusetts: The installation must be made by a licensed plumber or gas tter in the Commonwealth of Mas­sachusetts.
Sellers of unvented propane or natural gas-red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
www.desatech.com
114745-01D6
AIR FOR COMbUSTION
AND VENTILATION
WARNING: This heater shall
not be installed in confined space or unusually tight con­struction unless provisions are provided for adequate combus­tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efcient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy ef­cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, replaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol­lowing ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space
The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is dened
as construction where:
a. Walls and ceilings exposed to the out-
side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or
sealed and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window and door frames, between sole plates and oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings.
If your home meets all of the three
criteria above, you must provide ad­ditional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three
criteria above, proceed to Determining Fresh-Air Flow For Appliance Location.
Conned and Unconned Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 denes a conned space as a space whose vol-
ume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconned space.
* Adjoining rooms are communicating only if there are odorless passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW
FOR APPLIANCE LOCATION
Determining if You Have a Conned or Unconned Space
Use this work sheet to determine if you have a conned or unconned space.
Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
www.desatech.com
114745-01D 7
1. Determine the volume of the space (length x width x height).
Length x Width x Height = ________ cu. ft.
(volume of space) Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is sup­plied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
____________(volume of space) x 20 =
(Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x
20 = 51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free appliance _________Btu/Hr
Gas water appliance* _________Btu/Hr
Gas furnace _________Btu/Hr
Vented gas appliance _________Btu/Hr
Gas replace logs _________Btu/Hr
Other gas appliances* +_________ Btu/Hr
Total =_________Btu/Hr
* Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water appliance _________ Btu/Hr
Vent-free appliance +_________ Btu/Hr
Total =_________Btu/Hr
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
___________ Btu/Hr (maximum the space
can support)
____________Btu/Hr (actual amount of
Btu/Hr used) Example: 51,200 Btu/Hr (maximum the
space can support)
73,000 Btu/Hr (actual amount of Btu/Hr used)
AIR FOR COMbUSTION
AND VENTILATION
Continued
The space in the previous example is a conned space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconned space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See Ven-
tilation Air From Outdoors, page 8.
C. Install a lower Btu/Hr appliance, if lower
Btu/Hr size makes room unconned.
If the actual Btu/Hr used is less than the
maximum Btu/Hr the space can support, the space is an unconned space. You will need no additional fresh air ventilation.
WARNING: If the area in which
the appliance may be operated is smaller than that dened as an unconned space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described
in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining un­conned space. When ventilating to an adjoining unconned space, you must provide two perma­nent openings: one within 12" of the ceiling and one within 12" of the oor on the wall connecting the two spaces (see options 1 and 2, Figure 2 on page 8). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation for re-
quired size of ventilation grills or ducts.
40,000
33,000
73,000
www.desatech.com
114745-01D8
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the oor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet
or outlet air into attic if attic has a thermostat­controlled power vent. Heated air entering the attic will activate the power vent.
AIR FOR COMbUSTION
AND VENTILATION
Continued
Figure 3 - Ventilation Air from Outdoors
Figure 2 - Ventilation Air from Inside
Building
Outlet Air
Ventilated Attic
Outlet
A
ir
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
Or
Remove Door into Adjoining
Room, Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills Into Adjoining
Room,
Option 1
12"
12"
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heating source. If you have a central heating system, you may run system's circulating blower while using heater. This will help circulate the heat throughout the house. In event of a power out­age, you can use this heater as your primary heat source.
WARNING: A qualied ser-
vice person must install heater. Follow all local codes.
NOTICE: State or local codes may
only allow operation of this appli­ance in a vented conguration. Check your state or local codes.
WARNING: Make sure the
selector switch is in the OFF po­sition before installing heater.
WARNING: Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creo­sote, ashes and loose paint by a qualied chimney cleaner. Creo­sote will ignite if highly heated. A dirty chimney ue may create and distribute soot within the house. Inspect chimney ue for damage. If damaged, repair ue damper before operating appliance.
www.desatech.com
114745-01D 9
WARNING: Seal any fresh
air vents or ash clean-out doors
located on oor or wall of re­place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney ue damper.
WARNING: Never install
the heater
• in a bedroom or bathroom
unless installed as a vented
appliance, see page 12
• in a recreational vehicle
• where curtains, furniture,
clothing or other ammable objects are less than 42" from the front, top or sides of
heater
• in high trafc areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning u­ids, oil or kerosene lamps, etc..)
in the air exist, may discolor
walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is benecial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install in replace. Call dealer where you bought the appliance for proper type of appliance.
INSTALLATION
Continued
WARNING: This appliance is equipped for (natural or pro­pane/LP) gas. Field conversion is not permitted.
INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you can, provide greater clearances from oor, ceiling and adjoining wall.
MINIMUM FIREPLACE CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size 18", 24"
Side Wall 16"
Ceiling 42"
Floor 5"
*Measured at 14" depth Allow adequate clearances for accessibility for purposes of servicing and proper operation
LOG SIZING REQUIREMENTS
MINIMUM FIREBOX SIZE
Log
Size Height Depth
Front
Width
Rear
Width
18" 18" 14" 30" 20.5" 24" 18" 14" 35" 24.5"
Carefully follow the instructions below. This will ensure safe installation into masonry, UL127-listed manufactured replace or listed vent-free rebox.
Minimum Clearances For Side
Combustible Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall should follow diagram in Figure 4, page 10.
Example: The face of a mantel, bookshelf,
etc.. is made of combustible material must be 4" from the side of the replace to the cabinet (see Figure 4, page 10).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less than 42".
www.desatech.com
114745-01D10
NOTICE: Non thermostat con-
trolled heaters may be used as a vented product. If so, you must
always run heater with chimney
ue damper open and damper clamp installed. If running heater with damper open, noncombus­tible material above the replace opening is not needed. Go to
Installing Damper Clamp Ac­cessory for Vented Operation,
page 12.
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel proceed to If Using Man- tel. If not using mantel, follow the information
on this page.
You must have noncombustible material(s) above the replace opening. Noncombustible materi­als (such as slate, marble, tile, etc..) Must be at least 1/2" thick. With sheet metal, you must have noncombustible material behind it. Noncombus­tible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the replace hood accessory (24" Models Only). See Figure 5 for minimum clearances.
INSTALLATION
Continued
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
*
Example
Heat Resistant Material
(A)
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
Noncombustible Requirements for Material Distance (A) Safe Installation
12" or more N o n c o m b u s t i b l e material OK.
Between 8" and 12" 24" Models: Install replace hood
accessory (GA6050, GA6052, GA6053, see Accessories, page 26).
18" Model: Noncom­ bustible material OK.
Less than 8" Noncombustible m a te ri a l m u st b e
extended to at least 8". See Between 8" and 12", above. I f y o u cannot extend material, yo u m u s t o p er at e heater with ue damper o p e n. a n d d a mp er clamp installed
If Using Mantel
You must have noncombustible material(s) above the replace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombus­tible material is less than 12", you must install the replace hood accessory (24" Models Only). Even if noncombustible material is more than 12", you may need the hood accessory to deect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 11, for minimum clearances.
IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney ue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 12.
www.desatech.com
114745-01D 11
MANTEL CLEARANCES
In addition to meeting noncombustible material clearances, you must also meet required clearances between replace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of replace opening, a hood is not required (see Figure 6).
Determining Minimum Mantel Clearance When Using a Hood
If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using hood.
INSTALLATION
Continued
Figure 6 - Minimum Mantel Clearances
Without Using Hood
Figure 7 - Minimum Mantel Clearances
When Using Hood
Minimum Non­Combustible Material
Minimum Non­Combustible Material Height
Distances to Underside of Mantel
Top of Fireplace Opening
Underside of Mantel Shelf
12"
(A)
28" 34 1/2" 38 5/8" 42"
All minimum distances are in inches
2 1/2"
6"
8"
10"
Mantel Shelf
Minimum Non­Combustible Material
8" Min.
14 1/2" 18 5/8" 22 1/2"
All minimum distances are in inches
26"
2 1/2"
6"
8"
10"
12"
Distances to Underside of Mantel
Hood (GA6050, GA6052 or GA6053)
Top of Fireplace Opening
Underside of Mantel Shelf
NOTICE: Surface temperatures of adjacent walls and mantels be­come hot during operation. Walls and mantels above the rebox may become hot to the touch. If installed properly, these tem­peratures meet the requirement of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does not meet the minimum clear­ances shown, you must do one
of the following:
• operate the logs only with the
ue damper open and damper clamp installed
• raise the mantel to an ac-
ceptable height
• remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the oor level, you
must maintain the minimum distance of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14" to
the replace, you must install appliance at least 5" above the combustible ooring (see Figure 9).
14" Min.
Combustible Material
Noncombustible Material
Hearth
5" Min.
Combustible Material
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
www.desatech.com
114745-01D12
INSTALLATION
Continued
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented decorative, appliance must be installed only in a solid-fuel burning replace with a working ue and constructed of noncombustible material.
For Massachusetts Residents Only: Instal-
lation of this gas log set as a vented appliance in the Commonwealth of Massachusetts requires the damper be permanently removed or welded in the fully open position.
If your heater is a non-thermostatically-controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.
1. The replace does not meet the clearance to combustibles requirements for vent-free operation.
2. State or local codes do not permit vent-free operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently open chimney ue damper. You must install the damper clamp accessory (to order, see Accessories, page 26). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.
Figure 10 - Attaching Damper Clamp
Damper
Damper Clamp
Damper
Manufactured
Fireplace
Masonry
Fireplace
Damper Clamp
Damper
See chart below for minimum permanent ue opening you must provide. Attach damper clamp so the minimum permanent ue opening will be maintained at all times.
AREA OF VARIOUS STANDARD
ROUND FLUES
Diameter Area
5" 20 sq. inches
6" 29 sq. inches
7" 39 sq. inches
8" 51 sq. inches
Chimney
Height (ft.)
Minimum Permanent Flue
Opening
6' to 15' 39 sq. inches
15' to 30' 29 sq. inches
INSTALLING HEATER ASSEMBLY
WARNING: If installing in a sunken replace, special care is needed. You must raise the replace oor to allow access to heater control panel. This will insure adequate air ow and guard against sooting. Raise replace oor with noncombus­tible material. Make sure material is secure.
CAUTION: Do not pick up heater assembly by logs. This could damage unit. Only handle assembly by grates.
IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly.
Installation Items Needed
• control cover kit (provided with heater)
• approved exible gas hose and ttings (pro­vided with heater) (if allowed by local codes)
• sealant (resistant to propane/LP gas, not provided)
www.desatech.com
114745-01D 13
INSTALLATION
Continued
Note: Install optional GHRCTB Receiver and Hand-Held Remote Control Kit (see Accessories, page 26) before installing gas log heater. See in­stallation instructions included with the kit.
1. Apply pipe joint sealant lightly to male threads of gas tting (not provided). Connect approved exible gas hose to inlet side of gas control (see Figure 11).
2. Position heater assembly in replace.
3. Connect to gas supply. See Connecting To Gas Supply.
Figure 11 - Attaching Flexible Gas Hose
to Heater Gas Regulator
Gas Control Valve
Flexible Gas Hose (if allowed by local codes)
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualied service person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect
propane/LP replace directly to the propane/LP supply. This heater requires an external regu­lator (not supplied). Install the external regulator between the heater and propane/LP supply.
WARNING: Never connect
natural gas replace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved exible gas line with gas connector (if allowed by local codes) (provided)
* A CSA design-certied equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certied equipment shutoff valve from your dealer. See Accessories, page 26.
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pres­sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter­nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.
Propane/LP Supply Tank
External Regulator
Figure 12 - External Regulator With Vent
Pointing Down
Vent Pointing Down
www.desatech.com
114745-01D14
Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
IMPORTANT: Install equipment shutoff valve in an accessible location within 6 feet of the appli­ance. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 13, depending on your model. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
INSTALLATION
Continued
CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or ttings.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct all leaks at once.
WARNING: Never use an
open ame to check for a leak. Apply a noncorrosive leak detec­tion uid to all joints. Bubbles forming show a leak. Correct all leaks at once.
CAUTION: Make sure ex-
ternal regulator has been in­stalled between propane/LP supply and heater. See guide-
lines under Connecting to Gas Supply, page 13.
* Purchase the optional CSA design-certied equipment shutoff valve from your dealer. See Acces­sories, page 26.
**Minimum inlet pressure for purpose of input adjustment.
Figure 13 - Gas Connection (Remote-Ready Models Only)
To Gas Control Valve
3" Minimum
Sediment Trap
Propane/LP - From External Regulator (11" W.C.** To 14" W.C. Pressure)
Natural - From Gas Meter (5" W.C.** To 10.5" W.C. Pressure)
CSA Design-Certied
Equipment Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Tee Pipe Cap Joint Nipple
www.desatech.com
114745-01D 15
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where equipment shutoff valve was connected.
3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
4. Check all joints of gas supply piping system. Apply noncorrosive leak detection uid to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected t­tings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 14).
2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
3. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/ LP (see Figure 15 or 16). Apply noncorrosive leak detection uid to all joints. Bubbles form­ing show a leak.
4. Correct all leaks at once.
INSTALLATION
Continued
Figure 14 - Equipment Shutoff Valve
Equipment Shutoff Valve
Open
Closed
Figure 16 - Checking Gas Joints
(Natural Gas Only)
Control Valve Location
Equipment Shutoff Valve
Propane/LP Supply Tank
Equipment Shutoff Valve
Gas Meter
Figure 15 - Checking Gas Joints
(Propane/LP Gas Only)
Control Valve Location
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 14).
2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to gas control (see Figures 15 and 16). Apply noncorrosive leak detection uid to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 16). Check all other internal joints for leaks.
7. Turn off heater.
www.desatech.com
114745-01D16
OPERATING HEATER
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a re or explosion may result causing property damage, per­sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the oor because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neigh bor ’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call
the re department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t try to repair it, call a qualied service tech­nician or gas supplier. Force or attempted
repair may result in a re or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualied service technician to inspect the
appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING
• If replace has glass doors, never operate this heater with glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside replace will cause glass to burst. Also if replace opening has vents at the bottom, you must open the vents before operating heater.
• You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before run­ning heater.
NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange ame will also be pres­ent. Open damper or window to vent smell. This will only last a few hours.
Note: Home owners generally prefer to op­erate their heater with the chimney damper closed. This will put all the heat into the room.
However, there may be times you will desire the full ames of the HI heat setting but will nd the heat output excessive. You can open the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle will be hot if heater has been running.
1. STOP! Read the safety information, start­ing in column 1, of this page.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch in the OFF position.
4. Press in and turn control knob clockwise
to the OFF position (see Figure 17,
page 17).
www.desatech.com
114745-01D 17
WARNING: Burners will come on automatically within one minute when the switch
is in the ON position after the pilot is lit.
5. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the safety information, starting in column 1 of this page. If you don’t smell gas, go to the next step.
6. Press in and turn control knob counter­clockwise to the PILOT position.
Press in control knob for ve (5) seconds (see Figure 17).
Note: You may be running this heater for
the rst time after hooking up to gas sup­ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 18.
8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
• If control knob does not pop out when
released, contact a qualied service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8, page 16.
OPERATING HEATER
Continued
Figure 17 - Control Knob and Ignitor
Button Location, Manual Controlled
Piezo Ignitor
Switch in OFF Position
Control Knob
Flame Adjustment Knob
9. Slightly push in and turn control knob coun­terclockwise to the ON position.
10. Wait one minute and switch selector switch to the ON position to light burners. Note: AUTO is only function al when using GWMT1 or GWMS2 optional accessories.
11. Set ame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise to the PILOT position, or use remote control manual OFF button, or set selector switch in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from home for long periods of time. Heater will come on auto-
matically with selector switch in
the ON position.
Figure 18 - Pilot
Ignitor Electrode
Pilot Burner
Natural
Ignitor Electrode
Pilot Burner
Propane/LP
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position. 2b. If Using Optional Hand-Held Remote:
Set selector switch in the OFF position to
prevent draining battery.
3. Close equipment shutoff valve (see Figure 14, page 15).
www.desatech.com
114745-01D18
OPERATING HEATER
Continued
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting Instructions, page 16.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, page 17.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page
26). Follow instructions included with the
remote control.
NOTICE: You must light the pilot before using the hand-held re­mote control unit. See Lighting Instructions on page 16.
After lighting, let pilot ame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust ame adjustment knob anywhere
between HI and LO. Slide the selector switch to the REMOTE position (see Figure 19). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch
in the REMOTE or ON position when the pilot is not lit. This will drain the battery.
Figure 19 - Setting the Selector Switch,
Control Knob and Flame Adjustment
Knob for Remote Operation
REMOTE OFF ON
Piezo Ignitor
Selector Switch in REMOTE Position
Control Knob
Flame Adjustment Knob
ON/OFF SERIES (MODEL HRC100)
Hold the control button on the hand-held remote until burner turns on. Hold the con­trol button again until burner turns off (see
Figure 20).
To Lock press both buttons on hand-held
remote control until light stops ashing. Hand­held remote control is now locked. If the re is
on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.
To Unlock press both buttons together on hand-
held remote control until the light stops ashing.
The hand-held remote is now unlocked.
Figure 20 - On/Off Hand-Held Remote
Control Unit (HRC100)
THERMOSTAT SERIES (MODEL
HRC200)
The hand-held remote can be operated using ei-
ther the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 21, page 19). To select
Fahrenheit/Centigrade mode display, carefully
press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.
Manual Mode
1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.
2. Press the MANU button to turn on the
replace.
3. Press the POWER and LOCK buttons
together to turn off the replace.
Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by press­ing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons
together to turn off the replace.
Control Button
Indicator Light
www.desatech.com
114745-01D 19
Figure 21 - Thermostat Hand-Held
Remote Control Unit (HRC200)
Note: Do not leave the hand-held remote in
the AUTO mode close to the replace. The radiant heat from the replace will turn off the replace. Ideally, place the hand-held remote
in the center of the room facing towards the
replace.
Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent accidental ignition of the replace, the receiver
ON/OFF/REMOTE switch should be in the OFF position.
Auto Shutoff Feature
1. If the average room temperature reaches a range of 82° F (28° C) to 92° F (33° C), the
hand-held remote control will perform a
safety override and shut the replace off. This feature is not available in the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver will shut off the replace. This will occur in 8
or more minutes depending upon location of remote transmitter and strength of batteries.
OPERATING HEATER
Continued
Key Pad Lock Feature
This feature allows the user to lock/unlock the keypad on the hand-held remote in the
MANU or AUTO mode to prevent inadvertent
operation (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.
INSPECTING bURNERS
Check pilot ame pattern and burner ame pat­terns often.
PILOT FLAME PATTERN
Figure 22 shows a correct pilot ame pattern. Figure 23 shows an incorrect pilot ame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown in Figure 23
• turn heater off (see To Turn Off Gas to Appli- ance, page 17)
• see Troubleshooting, page 22
Note: The pilot ame on natural gas units will have a slight curve, but ame should be blue and have no yellow or orange color.
Figure 22 - Correct Pilot Flame Pattern
(Your pilot may vary from pilots shown)
Pilot Burner
Thermocouple
Figure 23 - Incorrect Pilot Flame Pattern
(Your pilot may vary from pilots shown)
Pilot Burner
Thermocouple
Locks System to Prevent Accidental Ignition
LOCK
MANU AUTO
ºC/ºF
TEMP
POWER
ROOM TEMP
SET TEMP
AUTO
Turns Hand­Held Remote On or Off and Allows You to Choose the Manual Setting
Selects AUTO Mode
°C/°F Mode Button
Turns Burners On or Off
Increases or Decreases Room Temperature in AUTO Mode
Digital Display Shows Temperature and Settings
Indicator Light
www.desatech.com
114745-01D20
INSPECTING bURNERS
Continued
BURNER FLAME PATTERN
Figure 24 shows correct burner ame pattern.
NOTICE: Do not mistake orange ames with yellow tipping. Dirt or other ne particles are burned by heater, causing brief patches of orange ame.
If burner ame pattern is incorrect, as shown in Figure 25
• turn heater off (see To Turn Off Gas to Appli- ance, page 17)
• see Troubleshooting, page 22
The ames from the burner travel horizontally through the log set and emerge at the middle and rear of the set against the back logs.
The ames are blue off the burner and as they progress through the log set, change to a light yellow color, yellow decorative ames are visible as the ames exit the log set.
The base of the log set and the underside of the top logs glow red. Natural gas models will burn with more blue ame, while propane gas model will burn with bright yellow ame.
Figure 24 - Correct Burner Flame Pattern
Figure 25 - Incorrect Burner Flame
Pattern
Blue and Bright
Yellow ames
Darker Orange Flames
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep control areas, burners and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.
WARNING: Failure to keep the primary air openings of the burner clean may result in soot­ing and property damage.
BURNER INjECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet openings allow the proper amount of air to mix with the gas. This provides a clean burning ame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet openings prior to each heating season. Blocked air openings will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualied service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com­pressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.
www.desatech.com
114745-01D 21
1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet opening on injector holder for dust and dirt (see Figure 26).
3. Blow air through the ports/slots and holes in the burner.
4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air opening on the injector holder.
6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the pilot ame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot ame comes out of the pilot assembly (see Figure 27). With the unit off, lightly blow air through the air inlet hole in the same direction as gas ow. You may blow through a drinking straw if compressed air is not available.
Figure 26 - Injector Holder On Outlet
Burner Tube
Burner Tube
Injector Holder
Injector
Primary Air Inlet Opening (At bottom)
Ports Slots
CLEANING AND
MAINTENANCE
Continued
Figure 27 - Pilot Inlet Air Hole (Your pilot
may vary from pilots shown)
Pilot Assembly
Pilot Air Inlet Hole
Pilot Assembly
Pilot Air Inlet Hole
WIRING DIAGRAM
Natural
Propane/LP
A
U
T
O
O
F
F
ON
Thermopile
www.desatech.com
114745-01D22
TROUbLESHOOTING
WARNING: Turn off and unplug heater and let cool before servicing.
Only a qualied service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor electrode not con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode positioned wrong or broken
1. Gas supply turned off or equip­ment shutoff valve closed
2. Control knob not in PILOT
position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when in-
stalled
5. Depleted gas supply (pro­pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep
ignitor cable dry
3. Tighten nut holding piezo ig­nitor to base panel of log set. Nut is located behind base panel.
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly for remote-ready units; Replace ignitor electrode for variable manually controlled units
1. Turn on gas supply or open equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while in PILOT position
4. Continue holding down con­trol knob. Repeat igniting operation until air is removed
5. Contact local propane/LP gas
company
6. Clean ODS/pilot (see Cleaning and Maintenance, page 20) or
replace ODS/pilot assembly
7. Replace gas regulator
OBSERVED PROBLEM
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but
no ignition
www.desatech.com
114745-01D 23
POSSIBLE CAUSE
1.
Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Safety interlock system has
been triggered
4. Equipment shutoff valve not fully open
5. Pilot ame not touching ther­mocouple, which allows ther­mocouple to cool, causing pilot ame to go out. This problem could be caused by one or both of the following:
A) Low gas pressure B) Dirty or partially clogged ODS/pilot
6. Thermocouple connection loose at control valve
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orice(s) clogged
3. Mislocated crossover tube
4. Burner orice(s) diameter is
too small
5. Remote sele c tor in OFF
position
6. Wire disconnected from gas
control
1. Manifold pressure is too low
2. Burner orice(s) clogged
3. Mislocated crossover tube
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep con­trol knob pressed in 30 seconds
3. Wait one minute for safety in­terlock system to reset. Repeat
ignition operation
4. Fully open equipment shutoff valve
5. A) Contact local natural or propane/LP gas company
B) Clean ODS/pil o t (se e
Cleaning and Maintenance, page 20) or replace ODS/pilot
assembly
6. Hand tighten until snug, then tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or pro­pane/LP gas company
2. Clean burner(s) (see Cleaning and Maintenance, page 20) or replace burner orice(s)
3.
Contact qualied service person
4. Replace burner orice(s)
5. Put remote selector in ON
position
6. See Wiring Diagram, page 21
1. Contact local natural or pro­pane/LP gas company
2. Clean burner(s) (see Cleaning and Maintenance, page 20) or replace burner orice(s)
3.
Contact qualied service person
1. Clean burner (see Cleaning and Maintenance, page 20) or replace burner orice
2. Replace damaged burner
3. Replace gas regulator
OBSERVED PROBLEM
ODS/pilot lights but ame goes out when control knob is re-
leased
One or both burners do not light after ODS/pilot is lit
Delayed ignition of burner
Burner backring during com­bustion
TROUbLESHOOTING
Continued
www.desatech.com
114745-01D24
POSSIBLE CAUSE
1. Not enough air
2. Gas regulator defective
1. Residues from manufacturing processes and logs curing
1. Turning control knob to HI position when burners are
cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orice(s)
1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue
1. Not enough combustion/ven-
tilation air
1. Metal expanding while heat­ing or contracting while cool-
ing
REMEDY
1. C h eck burner(s ) f o r dirt and debris. If found, clean burner(s) (see Cleaning and Maintenance, page 20)
2. Replace gas regulator
1. Problem will stop after a few hours of operation
1. Turn control knob to LO po­sition and let warm up for a minute
2. Operate burners until air is removed from line. Have gas line checked by local natural or propane/LP gas company
3. Obse rve minimum insta l­lation clearances (see pages 9 through 12)
4. Clean burners (see Cleaning and Maintenance, page 20) or replace burner orice(s)
1. Turn heater off when using furniture polish, wax, carpet cleaners or similar products
1. Refer to Air for Combustion and Ventilation requirements (page 6)
1. This is normal with most heat­ers. If noise is excessive, con­tact qualied service person
OBSERVED PROBLEM
Orange ame in burner during burner combustion
Slight smoke or odor during initial
operation
Heater produces a whistling noise when burners are lit
White powder residue forming within burner box or on adjacent walls or furniture
Moisture/condensation noticed on windows
Heater produces a clicking/tick­ing noise just after burners are lit or shut off
TROUbLESHOOTING
Continued
www.desatech.com
114745-01D 25
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Fol­low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
TROUbLESHOOTING
Continued
POSSIBLE CAUSE
1. Heater burning vapors from pa int, hair sp ray, glues , cleaners, chemicals, new carpet, etc. (See IMPOR- TANT statement above)
2. Low fuel supply (propane/ LP only)
3. Gas leak. See Warning
statement at top of page
1. Not enough fresh air is avail­able
2. Low line pressure
3. O D S/ p il ot i s p a rt i al ly
clogged
1. Gas leak. See Warning statement at top of page
2. Control valve or gas control defective
1. Foreign matte r betwe en control valve and burner
2. Gas leak. See Warning
statement at top of page
1. Hand-held remote control is
too close to heater
REMEDY
1. Open window to ventilate room. Stop using odor caus­ing products while heater is running
2. Rell supply tank (propane/LP only)
3. Locate and correct all leaks (see Checking Gas Connections, page 14)
1. Open window and/or door for ventilation
2. Contact local natural or pro­pane/LP gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 20)
1. Locate and correct all leaks (see Checking Gas Connec- tions, page 14)
2. Replace control valve or gas
control
1. Take apart gas tubing and remove foreign matter
2. Locate and correct all leaks (see Checking Gas Connections, page 14)
1. Move hand-held remote con­trol unit farther away from the
heater
OBSERVED PROBLEM
Heat e r pr o d uces unwante d
odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room temperature drops to a lower than ideal level before log set comes back on
www.desatech.com
114745-01D26
SPECIFICATIONS
VFRMV18NA VFRMV24NA VFRMV18PA VFRMV24PA
Btu (Variable) 24,000/36,000 28,000/39,000 26,000/34,000 31,000/39,000
Type Gas Natural Gas Only Natural Gas Only Propane/LP Only Propane/LP Only
Ignition Piezo Piezo Piezo Piezo
Manifold Pressure 3.5" - 1.6"W.C. 3.5" - 1.6"W.C. 10" - 6.3"W.C. 10" - 6.3"W.C.
Inlet Gas Pressure (in. of water) Maximum 10.5" W.C. 10.5" W.C. 14" W.C. 14" W.C. Minimum* 5.0" W.C. 5.0" W.C. 11" W.C. 11" W.C.
* For purpose of input adjustment
Manufactured by: DESA FMI. LLC, 1769 E. Lawrence St. Russellville, AL 35653 Note: This appliance has been designed-certied by ANS Z21.11.2a-2003 Unvented Room Heaters
and ANS Z21.60-2003.
Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Technical Service Department at 1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.
When calling DESA, have ready
• model and serial numbers of your heater
• the replacement part number
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specied heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con­tact your local propane/LP or natural gas supplier.
ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
EQUIPMENT SHUTOFF VALVE GA5010
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
FIREPLACE HOOD
Black - GA6050 Brass - GA6052 Antique Brass - GA6053
For all models. Helps deect heat away from mantel or wall above replace. Fits openings 28" to 48" wide.
TECHNICAL SERVICE
You may have further questions about installation, operation or troubleshooting. If so, contact DESA Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.
You can also visit DESA technical services web site at www.desatech.com.
www.desatech.com
114745-01D 27
RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL
KIT - HRC200
For all models. Allows the gas log heater to be oper­ated in a manually or thermostatically controlled mode. You can turn the gas log heater on and off without ever leaving the comfort of your easy chair. A wall-mount docking station is included.
RECEIVER AND HAND-HELD
REMOTE CONTROL KIT - HRC100
For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control. A wall-mount docking station is included.
WALL-MOUNT THERMOSTAT
SWITCH - GWMT1 (Not Shown)
For all models. The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.
WALL-MOUNT ON/OFF SWITCH GWMS2 (Not Shown)
For all models. Allows the gas log heater to be turned on and off with a wall switch.
VENT-FREE LOGMATE® FIREBOXES
(Not Shown)
Available in 32", 36" and 42" models. Circu­lating reboxes feature louvers and an optional blower. Non-circulating, smooth face models are ideal for custom trim applications such as stone or marble.
FB32C (CIRCULATING), FB32NC (NON-CIRCULATING) SERIES (Not Shown)
For all models.
ACCESSORIES
Continued
FB36CA, FB42C SERIES (CIRCULATING), FB36NCA, FB42NC SERIES (NON-CIRCULATING) (Not Shown)
For all models.
DAMPER CLAMP - GA6080 (Not Shown)
For all models. Permanently opens chimney ue damper for vented operation.
LAVA ROCK - GA6060 (Not Shown)
For all models. Order when additional rock is desired. (1.8 lb. bag)
CLEANING KIT - GCK (Not Shown)
For all models. Your vent-free gas appliance re­quires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
FLOOR MEDIA KIT - FM100 (Not Shown)
For all models. This kit is used to blend the edge of the burner to the replace oor for a more natural appearance. It includes embers, lava rock and nine ber log pieces.
CONTROL COVER MEDIA KIT CC100 (Not Shown)
For all models. This kit is used as an addition to or instead of the Floor Media Kit FM100. It includes 6 ber log chunks to be placed on the replace oor in front of the controls for a more natural appearance.
www.desatech.com
114745-01D28
ILLUSTRATED PARTS bREAkDOWN
VFRMV18NA, VFRMV18PA VFRMV24NA (Shown), VFRMV24PA
1
2
3
4
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
24
24
24
24
24
24
5
25
26
27
www.desatech.com
114745-01D 29
PARTS LIST
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
KEY NO.
PART NUMBER
DESCRIPTION QTY.VFRMV18NA VFRMV24NA VFRMV18PA VFRMV24PA
1 114854-01 114790-01 114854-01 114790-01 Grate Assembly 1 2 114860-01 114807-01 114860-01 114807-01 Log Set Assembly 1 3 114858-02 114797-02 114858-01 114797-01 Burner 1 4 114798-01 114798-01 114798-01 114798-01 Burner Support Bracket 1 5 11209 11209 11209 11209 10-24 Hex Nut 1 6 114799-04 114799-03 114799-02 114799-01 Orice 1 7 114802-01 114802-01 114802-01 114802-01 Orice Bracket 1 8 111807-01 111807-01 111807-02 111807-02 SIT Millivolt Valve 1 9 114795-01 114795-01 114795-01 114795-01 Valve Mounting Bracket 1 10 103779-01 112376-01 114859-01 114859-01 ODS Pilot Assy 1 11 114805-01 114805-01 114805-01 114805-01 Pilot Bracket 1 12 115027-01 115027-01 115027-01 115027-01 Pilot Shield 1 13 114793-01 114793-01 114793-01 114793-01 Piezo/Switch Bracket 1 14 097159-04 097159-04 097159-04 097159-04 Piezo 1 15 14579 14579 14579 14579 Rocker Switch 1 16 111817-01 111817-01 111817-01 111817-01 Main Gas Line 1 17 114804-01 114804-01 114804-01 114804-01 ODS Pilot Line 1 18 103784-01 103784-01 103784-01 103784-01 ON/PILOT/OFF Knob
Extension
1
19 103784-02 103784-02 103784-02 103784-02 HI/LO Knob Extension 1 20 098271-13 098271-13 097271-13 098271-13 Piezo Wire 1 21 111828-01 111828-01 111828-01 111828-01 Compression Sleeve And
Nut, 3/16"
1
22 111824-01 111824-01 111824-01 111824-01 Fitting 3/8" NPT Male To
3/8" Comp.
1
23 114801-01 114801-01 114801-01 114801-01 Fitting 1/8" NPT Male To
3/8" Comp.
1
24 111800-01 111800-01 111800-01 111800-01 10-24 x 3/8" Screw 16 25 103284-02 103284-02 103284-02 103284-02 Wire Harness 1 26 114800-01 114800-01 114800-01 114800-01 3/8" Flat Washer 2 27 111816-01 111816-01 111816-01 111816-01 #10-32 x 3/8" Screw 2
PARTS AVAILABLE NOT SHOWN
100563-01 100563-01 100563-01 100563-01 Warning Plate 1 103877-01 103877-01 103877-01 103877-01 Lighting Instruction Plate 1 100639-01 100639-01 100639-01 100639-01 Caution Decal 1 GA6060 GA6060 GA6060 GA6060 Lava Rock 1
www.desatech.com
114745-01D30
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
NOTES
www.desatech.com
114745-01D 31
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
NOTES
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
NOT A UPC
WARRANTy INFORMATION
kEEP THIS WARRANTy
Model
Serial No.
Date Purchased
114745-01 Rev. D 09/06
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTy
VENT-FREE GAS LOG HEATERS
DESA warrants this product to be free from defects in materials and components for four (4) years from the date
of rst purchase, provided that the product has been properly installed, operated and maintained in accordance
with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be
presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to
restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized
Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who
will provide original factory replacement parts. Failure to use original factory replacement parts voids this war-
ranty. The heater MUST be installed by a qualied installer in accordance with all local codes and instructions
furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that
fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper
installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a
defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4)
YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS
HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE
FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE-
QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on
damages may not apply to you.
This warranty gives you specic legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
114745 01