All installations must be in accordance with these instructions. Consult
with the building authority having jurisdiction to obtain a
permit prior to commencing the installation. Failure to follow these
instructions may also void your fire insurance and warranty.
1
INDEX
Page No: 2 ……………. 1 Warnings 3 ……………. 2 Installation Responsibilities 3 ……………. 3 Floor Protector Requirements 4 ……………. 4 Installation Clearances 5 ……………. Fire Dimensions 6 ……………. 5 Assembly Instructions 7 ……………. Diagram of Outside Air Kit 8/9 ……………. 5a Assembly Instructions when installing Outside Air Kit 10 ……………. 6 Wet Back 11 ……………. 7 Flue Installation 12 ……………. Minimum Height of Flue Exit 13 ……………. Fitting Seismic Restraints
Please leave this book with the owner when installation is complete.
Edited 6/3/2011
Item No: Topic:
2
1. WARNINGS
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.
This Firenzo fire has been tested to N.Z. Standards AS/NZS 2918:2001.
If this heater is incorrectly installed a house fire may result. For your safety follow the installation instructions carefully.
Do NOT connect the heater to a chimney serving another appliance.
Although the exterior of the heater may appear cool, contact with the unit may cause burns, warn children and others of the possibility of injury should they touch the heater.
Do NOT dry clothing or unseasoned wood directly in contact with the heater.
Keep all household combustible materials at least 600mm away from front of the heater. This includes clothing, furniture, wood, newspaper, plastic, matches, etc.
DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.
Use caution when reloading with fuel. Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its peak.
Do NOT burn large quantities of paper or combustible material that would create an extremely hot/quick fire.
USE ONLY DRY WOOD. AVOID BURNING WET OR GREEN WOOD.
THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE HAZARDOUS. TIMBER TREATED WITH COPPER CHROMIUM AND ARSENIC TYPE PRESERVATIVES WILL LEAVE TOXIC RESIDUES IN THE ASH, FIREBOX OR WITHIN THE FLUE; TIMBER OFFCUTS FROM BUILDING CONSTRUCTION WILL OFTEN CONTAIN BORIC SALTS. THE COMBUSTION OF THIS MATERIAL OVER PROLONGED PERIODS CAN PRODUCE ADVERSE EFFECTS ON REFACTORY LINING IN SOLID FUEL APPLIANCES. EMISSION OF POISONOUS GASES CAN ALSO BE EXPERIENCED WITH THE BURNING OF TREATED WOOD.
Driftwood with salt content will also cause rapid deterioration of the heater and should not be used.
3
2. INSTALLATION RESPONSIBILITIES
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED
IN ACCORDANCE WITH AS/NZ 2918:2001 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.
Strict adherence to these instructions will meet these standards. Any variation from these installation instructions or any doubt about them must be checked against the requirements of the Standards.
WARNING:
Care must be taken to protect the wetback coil and associated pipe work if being installed in a hard/corrosive water area. Damage caused to the Wetback coil if fitted in a hard/corrosive water area will not be covered under the manufacturer’s warranty.
Please leave this manual with the owner when installation is complete.
3. FLOOR PROTECTOR REQUIREMENTS
The heater should always be installed on top of its base due to high temperatures sustained over long periods. The base must be anchored to both the floor protector and the floor for seismic restraint. Anchor points are provided in the base or on the rear legs.
DRAWER BASE AND PEDESTAL MODELS: If the heater is to be placed on or within 500mm of a heat sensitive floor, an
protector
approved insulation material i.e. 2 sheets of 10mm micorboard or superlux, 10mm tile backing board and 10mm tiles or similar on the top surface. All joints on the upper surface should be sealed to prevent spilt ash from contacting any heat-sensitive material.
LEG BASE MODELS:
These models require an ash floor protector to AS/NZS 2918:2001 – i.e. a floor protector consisting of an upper surface, including grouting, of a durable, non-combustible material.
with a minimum thickness of
40mm
insulated floor
is required consisting of 20mm of an
4
FLOOR PROTECTOR DIMENSIONS
:
Refer to drawings under 4. Installation Clearances.
The standard front clearance from the front of the door glass can be reduced by increasing the insulated floor protector height. FLOOR PROTECTOR HEIGHT 40mm 50mm 60mm 70mm 100mm CONTESSA URBAN FRONT CLEARANCE 420 405 390 375 320 CONTESSA RURAL “ “ 420 405 390 375 320 BRONTE RURAL “ “ 330 325 320 315 310 LADY KITCHENER RU & URBAN “ 300 300 300 300 300
4. INSTALLATION CLEARANCES
All fires are to be installed with a flue pipe shield.
FREESTANDING FIRE A B C D E F G H J K L M N O BRONTE TOP OUTLET RU PEDESTAL & DRAWER BASE 100 245 330 100 100 230 550 405 810 895 1240 1090 665 630 LEG BASE 100 245 300 100 100 230 550 405 810 865 1210 1070 635 630 LADY KITCHENER RU PEDESTAL & DRAWER BASE 100 240 300 100 95 270 495 395 710 1050 1365 1145 780 540 LEG BASE 100 240 300 100 95 270 495 395 710 1050 1365 1145 780 540 LADY KITCHENER URBAN PEDESTAL & DRAWER BASE 100 240 300 100 95 270 495 395 710 1050 1365 1145 780 540 LEG BASE 100 240 300 100 95 270 495 395 710 1050 1365 1145 780 540 CONTESSA RU PEDESTAL & DRAWER BASE 130* 280 420 110 100 260* 600 420 860 1055* 1380 1200 795 600 LEG BASE 130* 280 350 110 100 260* 600 420 860 985* 1310 1130 725 600 CONTESSA URBAN PEDESTAL & DRAWER BASE 130* 280 420 110 100 260* 600 420 860 1055* 1380 1200 795 600 LEG BASE 130* 280 350 110 100 260* 600 420 860 985* 1310 1130 725 600
*Contessa Clearance A, F, K can be reduced BY 30mm provided a Contessa cooktop grill is fitted onto the rear cast top of the fire
Clearances are to a heat sensitive material
5
When installing the Firenzo fire on a leg base ADD 70mm to vertical measurements shown:
LADY KITCHENER 800 -
URBAN conforms with NES standards
- RU for houses sited on 2 hectares or more
3 or 5Kw Wetback
3Kw Wetback Urban Only
RU
Only
-------------------------------------------------------------------------------------------------------
CONTESSA -
URBAN conforms with NES standards
- RU for houses sited on 2 hectares or more
-------------------------------------------------------------------------------------------------------
BRONTE -
RU for houses sited on 2 hectares or more
6
5. ASSEMBLY INSTRUCTIONS
1. Remove all packaging and timber.
2. Remove loose parts from inside the firebox.
3. Position the base with angle steel down onto the floor protector, taking the necessary final clearance into consideration. The base has the flue centre indicated on the flat steel bracket. These measurements coincide with the figures on page 4 for the heater clearances when assembled.
4. At this point a hole in the ceiling to accommodate the flue may be cut and the liners installed.
5. Remove both front and rear top castings.
6. Place firebox on base. Secure with brackets provided.
7. Fit the wetback, if allowable, in accordance with accepted plumbing practice - please refer to page 10. Ensure wetback is NOT pushed down; if it touches or comes in contact with the baffle bricks this will cause wear which will void your warranty. If NO wetback is to be fitted please ensure that blanking plugs are attached to the two holes in the rear of the upper chamber.
8. Replace the rear top casting and refit the front top casting ensuring it fits neatly into the sealed channel.
9. Refit the stainless steel flue shim in the top rear section of the firebox.
10. Assemble and fit flue and flue shield as per instructions (page 11).
11. Secure the wood-burner to the floor protector for seismic restraint (refer instructions on page 13). DUE TO NZ BEING AN EARTHQUAKE PRONE COUNTRY, IT IS IMPORTANT TO ANCHOR THE FIRENZO FIRE DOWN IN CASE OF EARTH MOVEMENT.
12. BRONTE FIRE ONLY Attach it to the heatshield on the rear of the fire with the bolts provided.
13. CONTESSA FIRE ONLY then you will need to fit the cook top grill onto the rear casting of the CONTESSA fire. Attach it to the heatshield on the rear of the fire with the bolts provided.
13. Assemble and fit the decorative rails.
14. Fit handle as shown on diagram
15. Fit the control knob - place the flat on the knob to the flat on the air control shaft situated on the right handside of the fire. Press home firmly.
: Fit the cook top grill on the rear casting of the BRONTE fire.
: If reducing clearance A from 130mm to 100mm as on page 5
7
8
5a. ASSEMBLY INSTRUCTIONS
IF INSTALLING FIRE WITH AN OUTSIDE AIR KIT
1. Establish position of heater before fixing.
2. Cut holes in both lining and exterior cladding of approx 100mm wide and 75mm high to accommodate duct (see drawings).
3. If a wall stud is located at centre of heater position, the wall penetration should be moved to one side. Allowance is made on the heater to move ducting laterally by placing offset duct spigot in appropriate position.
4. For standard pedestal base or drawer models, the bottom of the cut-out should be 90mm above floor protector. For models with legs the bottom of the cut-out should be 160mm.
5. Remove all packaging and timber.
6. Remove loose parts from inside the firebox.
7. Position the base with angle steel down onto the floor protector, taking the necessary final clearance into consideration. The base has the flue centre indicated on the flat steel bracket. The label next to this point states the minimum clearances from the base to combustible surfaces. These measurements coincide with the figures on page 4 for the heater clearances when assembled.
8. At this point a hole in the ceiling to accommodate the flue may be cut and the liners installed.
9. Remove both front and rear top castings.
10. Remove rear heat shield and fit duct spigot by drilling and securing to body ensuring that it lines up with the wall penetration.
11. Replace heat shield and secure the unit in place.
12. Place firebox on base. Secure with brackets provided.
13. Fit the wetback, if allowable, in accordance with accepted plumbing practice - please refer to page 10. If NO wetback is to be fitted please ensure that blanking plugs are attached to the two holes in the rear of the upper chamber.
14. From outside feed the duct through the wall, slip the interior flange over the duct and push into the duct spigot on heater. (mark and trim the duct if necessary, this should terminate approximately 5-10mm short of the external wall face).
15. Place the external cover over the duct and fix with the 4 screws provided.
16. Slide interior flange against lining and secure to duct.
9
17. Replace the rear top casting and refit the front top casting ensuring it fits neatly into the sealed channel.
18. Refit the stainless steel flue shim in the top rear section of the firebox.
19. Assemble and fit flue and flue shield as per instructions (page 11 & 12).
20. Secure the wood-burner to the floor protector for seismic restraint (refer instructions on page 13). DUE TO NZ BEING AN EARTHQUAKE PRONE COUNTRY, IT IS IMPORTANT TO ANCHOR THE WOODBURNER DOWN IN CASE OF EARTH MOVEMENT.
12. Fit the cook top grill on the rear casting of the Contessa
fire and Bronte fire. Attach it to the
heat shield on the rear of the fire with the bolts provided.
21. Assemble and fit the decorative rails.
22. Fit door handle as shown - -
22. Fit the control knob - place the flat on the knob to the flat on the air control shaft situated on the right hand side of the fire. Press home firmly.
10
6. WETBACK
The following Firenzo fires can be fitted with a wetback to supplement the hot water system:
Lady Kitchener 800 URBAN or RU Contessa RU Bronte RU
WARNING
DO NOT CONNECT TO AN UNVENTED HOT WATER SYSTEM.
DO NOT USE THIS FIRE WITHOUT WATER RUNNING THROUGH THE WETBACK.
INSTALL IN ACCORDANCE WITH AS 3500.4.1 OR NZS 4603 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
For best performance apply the following rules:
1. Keep it simple with the shortest and straightest possible pipe run.
2. The heater should be within 6 metres of the hot water cylinder, the closer the better.
3. The flow pipe from the heater to the cylinder must rise – the cylinder should be at least 300 mm above the water-booster outlet.
4. Use only 25mm supply and return pipes.
5. Where possible the pipes should be insulated.
WARNING:
Care must be taken to protect the wetback coil and associated pipe work if being installed in a hard/corrosive water area. Damage caused to the Wetback coil if fitted in a hard/corrosive water area will not be covered under the manufacturer’s warranty.
:
11
7. FREESTANDING FLUE SYSTEM INSTALLATION INSTRUCTIONS
1. Position heater on floor protector ensuring all heater clearances are correct as per clearances on page 4.
2. Once the location is confirmed, the appliance and floor protector shall be fixed to the floor itself (refer to page 6 & 7).
3. Extend a plumb line from the centre of the fire flue pipe spigot to the ceiling. Mark position on ceiling and roof.
4. Trim hole and nog as required ensuring that a 25mm safe clearance between combustible materials and flue components is maintained. Fix with non combustible spacers and screws or clouts on all four sides.
5. Cut and frame (when required) an opening in the roof, position the outer casing through the roof until it is flush with the under side of the ceiling, making sure as with the ceiling there is a 25mm safe clearance between non-combustible materials and the flue components. Fix as in step 4.
6. Fix appropriate flashing around outer casing to the roof to ensure a weatherproof seal.
7. Assemble flue pipe sections ensuring all seams are in line, the assembly is straight and crimped. Ends are pointing downwards. Fix each joint with three stainless rivets or self-tapping screws.
8. Place ceiling plate with folded edges upwards over heater spigot.
9. Position the flue pipe into the heater spigot. The flue pipe can either lowered from the top as a single unit or fed up from the room a length at a time, ensuring that all joints are fixed properly.
10. Slide the inner casing into place, between the outer casing and the flue pipe.
11. The flue pipe must extend 200mm above the outer casing. Note: Extra lengths of flue pipe, inner and outer casing may be required to achieve the minimum clearance from the roof.
12. Slide top spreader over flue pipe down into outer and inner casing and tighten.
13. Slide cowl over flue pipe until it rests on spreader. Secure with rivets or self-tapping screws.
14. Fit rainhat. Do not fasten as it must be removable for flue pipe cleaning.
15. Fix ceiling plate to ceiling maintaining an even gap all around the flue pipe. Note: Ensure ceiling plate is spaced off from the ceiling with ceramic spacers supplied.
16. Fit the flue shield.
CAUTION
specifications of components may result in hazardous conditions. Where such action is considered the manufacturer should be consulted in the first instance.
WARNING
appropriate requirements of the relevant building code or codes.
: Mixing of appliance or flue system components from different sources or modifying the dimensional
: The appliance and flue system shall be installed in accordance with AS/NZS 2918:2001 and the
12
13
FITTING SEISMIC RESTRAINT BRACKETS
PEDESTAL OR DRAWER BASE MODELS
1. Remove bolts at rear of fire box
2. Fit Seismic Restraint brackets
3. Secure both the floor protector and the appliance to the floor by using a dyna bolt or similar.
LEG MODELS
1. Place firebox on leg assembly and fit brackets.
2. Locate as per appropriate clearances
3. Secure both the floor protector and the appliance to the floor using a dyna bolt or similar.
14
FIRENZO
WOODFIRES
BY
Hewitsons Limited
Manufacturers of:
Lady Kitchener
Contessa
Bronte
Royale
Zealandia
Coaster
Viking
Athena
Forte Deco Plaza
Aqualux
68 Austin Street
Onekawa
PO Box 3231
HB Mail Centre
Napier 4142
Phone: 06 8438260
Fax: 06 8430505
Email: hothouse@firenzo.co.nz
Web: www.firenzo.co.nz