Fire Magic EDOP02 User Manual

SINGLE SIDEBURNER &
DOUBLE SIDEBURNER
diamond series
32794-1, 32814, 32814H Series
INSTALLATION AND
OWNER'S MANUAL
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
Important: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION
WARNINGS AND SAFETY CODES
DANGER:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or the fi re department.
CODE AND SUPPLY REQUIREMENTS: This appliance must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with the latest National Fuel Gas
Code (ANSI Z223.1/NFPA 54), or Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
This appliance and its dedicated manual shutoff valve must be disconnected from the gas-supply piping system when testing the system at pressures
in excess of ½ psig (3.5 kPa). This appliance must be isolated from the gas-
supply piping system by closing its dedicated manual shutoff valve during any pressure testing of the gas-supply system at pressures up to and including ½ psig (3.5 kPa).
Proper operation of your appliance requires prompt and periodic maintenance. See the SERVICING AND CLEANING section for details.
32814 Series
shown
WARNING:
1. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING:
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. For proper installation, refer to the installation instructions. For assistance or additional information, consult a qualifi ed professional service technician, service agency, or the gas
supplier.
All electrical outlets in the vicinity of the appliance must be properly grounded in accordance with local codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever
is applicable. Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
®
C
09-41
US
Certifi ed to: ANSI Z21.58-2015 CSA 1.6-2015
REV 6 - 1712110720
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
1
L-C2-334
SÛRETÉ ET CODES D’AVERTISSEMENT
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
DANS LE CONTRE- SINGLE ET DOUBLE SIDEBURNER
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez le gaz à l’appareil.
2. Éteignez-vous n’importe quelle fl amme nue.
3. Ouvrez le couvercle si équipé d’un four.
4. Si l’odeur continue, gardez loin de l’appareil et appelez immédiatement votre département de fournisseur ou de feu de gaz.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre le plus défunt Code national de gaz de carburant (norme ANSI Z223.1/NFPA 54), et Stockage de gaz naturel et de propane et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être démontés du gaz-fournissent le système siffl ant en examinant le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système siffl ant par fermeture que ses différents robinets d’isolement manuels pendant tous les essais sous pression du gaz­fournissent le système aux pressions jusques et y compris le ½ psig (kPa 3.5).
• Ce gril est pour ultilisation à l’extérieur seulement. Si l’appareil est entreposé à l’intérieur, enlever les bouteilles et les laisser à l’extérieur.
• Ne pas ranger le gril immédiatement aprés l’avoir utilisé. le laisser refroidir avant de le déplacer ou de la ranger. Le non respect de cette mesure de sécurité pourrait entraîner un incendie causant des dommages à la propriété, des blessures ou la mort.
• Ne pas utiliser cet appareil sous une surface combustible.
• Ne pas utiliser cet appareil sous un auvent. Le non respect de cette mesure de sécurité pourrait entraîner un incendie ou des blessures.
• Dégagement minimal entre les parois latérales et l’arriére de l’appareil et la construction combustible (45.7 cm à partir des parois latérales et 45.7cm à partir de l’arriére).
• Le régulareur de pression de gaz prévu avec cet appareil de cuisson à gaz pour l’extérieur doit être utilisé. Ce régulateur est réglé pour une pression de sortie de 5 pouces de colonne de l’eau pour le gaz naturel, et 10 pouces pour le propane.
• LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE CARRÉ). SI VOTRE OFFRE DE GAZ EST 1/2 PLUS GRAND QUE (LIVRES PAR POUCE CARRÉ), UN RÉGULATEUR ADDITIONNEL DOIT ÊTRE INSTALLÉ AVANT LE GRIL. VOIR LA SECTION DE CONDITIONS
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas l’essence ou d’autres vapeurs et liquides infl ammables à proximité de ceci ou d’aucun autre appareil.
2. Un cylindre de propane non relié pour l’usage ne sera pas stocké à proximité de ceci ou d’aucun autre appareil.
AVERTISSEMENT:
L’installation inexacte, l’ajustement, le changement, le service, ou l’entretien peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour de l'aide ou des renseignements supplémentaires, consultez un technicien professionnel qualifié de service, une agence de service ou le fournisseur de
gaz.
Toutes les sorties électriques à proximité du gril doivent être correctement fondues selon des codes locaux, ou en l’absence de local code, avec le code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui est applicable.
Maintenez tout électrique-fournissent des cordes et carburant­fournissent des tuyaux partis de n’importe quelle surface de chauffage.
D’OFFRE DE GAZ POUR LA PRESSION APPROPRIÉE D’OFFRE DE GAZ.
• Ne couvrez jamais la surface entière de cuisine ou de gril de gauffreuses ou de casseroles. La surchauffe se produira et les brûleurs ne seront pas très performants quand la chaleur de combustion est emprisonnée au­dessous de la surface à cuire.
• Ne pulvérisez jamais l’eau sur une unité chaude de gaz, comme ceci peut endommager des composants de porcelaine ou de fer de fonte.
• Une fuite de GPL peut causer une incendie ou une explosion si enflammée entraînant des blessures corporelles graves ou la mort.
• Communiquez avec le fournisseur de GPL pour les réparations ou pour disposer de qules bouteille ou du GPL non utilisé.
Certifi é à la norme: ANSI Z21.58-2015 CSA 1.6-2015
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
REV 6 - 1712110720
2
L-C2-334
GETTING STARTED
GETTING STARTED
INSTALLATION, OPERATION, AND SAFETY INFORMATION ......................................................................................4
ELECTRICAL CONNECTIONS ......................................................................................................................................4
GAS SAFETY INFORMATION ........................................................................................................................................5
WARNING .................................................................................................................................................................5
WHEN USING PROPANE GAS ......................................................................................................................................5
WHEN USING NATURAL GAS ......................................................................................................................................5
OPERATING THE UNIT SAFELY AND CORRECTLY .....................................................................................................5
SAFE USE & MAINTENANCE OF PROPANE GAS BOTTLES ........................................................................................7
ENCLOSURE / VENTILATION REQUIREMENTS ...........................................................................................................8
VENTILATION (ALL ENCLOSURES) ..............................................................................................................................8
WHEN A PROPANE (L.P.) CYLINDER IS USED IN THE ENCLOSURE .................................................................................9
INSTALLATION REQUIREMENTS .............................................................................................................................. 10
OVERHEAD CONSTRUCTION REQUIREMENTS .......................................................................................................... 10
SIDE AND REAR WALL CLEARANCES .........................................................................................................................11
BACKSPLASH CLEARANCE (if applicable) ...................................................................................................................11
ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW ...................................................................................12
GAS-SUPPLY PLUMBING REQUIREMENTS ................................................................................................................ 12
ELECTRICAL SAFETY ................................................................................................................................................13
MODEL SPECIFICATIONS ........................................................................................................................................... 14
SPECIFICATIONS TABLE ......................................................................................................................................... 14
DIMENSIONS TABLE ............................................................................................................................................... 14
CUTOUT DIMENSIONS TABLE .................................................................................................................................. 15
COUNTERTOP OVERHANG ...................................................................................................................................... 15
ENCLOSURE VENTILATION ..................................................................................................................................... 15
COMBUSTIBLE ENCLOSURE CUT-OUT ..................................................................................................................... 16
SUBSTRATE ............................................................................................................................................................ 16
WIRING DIAGRAM .................................................................................................................................................. 17
REPLACEMENT PARTS LIST ......................................................................................................................................18
CONTENTS
INSTALLATION
INSTALLATION ........................................................................................................................................................... 19
COUNTER PREPARATION ........................................................................................................................................19
CONNECT THE GAS SUPPLY .................................................................................................................................... 19
CONNECT TO A POWER SOURCE .............................................................................................................................20
POWER SUPPLY (MULTIPLE ACCESSORY UNITS) ...................................................................................................... 22
SLIDE UNIT INTO ENCLOSURE ................................................................................................................................ 23
POSITION THE BURNER CAP(S) ............................................................................................................................... 23
INSTALL THE BURNER COVER ................................................................................................................................. 23
USE, CARE, & SERVICE
IDENTIFICATION OF CONTROLS ............................................................................................................................... 24
USING THE APPLIANCE .............................................................................................................................................25
LIGHTING (IGNITION) INSTRUCTIONS ..................................................................................................................... 27
ELECTRONIC LIGHTING ......................................................................................................................................... 27
MANUAL LIGHTING ................................................................................................................................................ 27
SHUTTING OFF THE UNIT ....................................................................................................................................... 27
SER VICING AND CLEANING ...................................................................................................................................... 28
CONVERT GAS TYPE / CHECK BURNER ORIFICES .................................................................................................... 29
AIR SHUTTER ADJUSTMENT ................................................................................................................................... 31
CONTROL PANEL REMOVAL .................................................................................................................................... 32
TROUBLESHOOTING .................................................................................................................................................. 33
WARRANTY ................................................................................................................................................................ 34
REV 6 - 1712110720
3
L-C2-334
INSTALLATION, OPERATION, AND SAFETY INFORMATION
1. The outdoor appliance and surrounding area MUST
remain clear of fl ammable substances such as gasoline, yard debris, wood, etc.
2. Do not block the 1" front air inlet along the bottom of
the control panel.
3. This unit must be installed so that the required vent openings and surrounding area of the enclosure remain clear and free at all times. See the ENCLOSURE/VENTILATION REQUIREMENTS section for details.
4. When using propane gas: the propane cylinder,
nests. A clogged tube can lead to a fi re beneath the unit. A proper fl ame pattern will ensure safe operation and optimal performance. Adjust the air shutter as needed (see SERVICING AND CLEANING, AIR SHUTTER ADJUSTMENT).
7. The in-line gas valve or gas cylinder valve must always
be shut OFF when the unit is not in use.
8. Whenever reconnecting any wires, apply a small
amount of dielectric grease to the male connector, then make the connection. This will ensure conductivity and prevent moisture from affecting the contact.
regulator, and rubber hose must be in a location not subject to temperatures above 125° F (51° C).
5. Do not operate the burner with the cover in place.
6. The fl ames on each burner burn evenly along the
entire burner caps with a steady fl ame (mostly blue). If burner fl ames are not normal, check and clean the orifi ce and burner/venturi tubes for insects and insect
CAUTION: FOR YOUR SAFETY, you must provide openings in the enclosure for replacement air and
ventilation (in case of possible leakage from gas connections or propane cylinders). Failure to do so may result in a fi re or explosion causing property damage, bodily injury, or death. See the ENCLOSURE / VENTILATION REQUIREMENTS section for details.
IMPORTANT
IN THE EVENT OF A GREASE FIRE, IMMEDIATELY SHUT OFF THE MAIN GAS VALVE TO THE UNIT. KEEP THE LID OPEN AND ALLOW THE FIRE TO EXTINGUISH ITSELF. A THOROUGH INSPECTION BY A TRAINED SERVICE TECHNICIAN SHOULD BE CONDUCTED BEFORE FUTURE USE OF YOUR UNIT. THE SERVICE TECHNICIAN WILL CHECK THE SYSTEM FOR GAS LEAKS AND WILL CHECK ALL ELECTRICAL WIRING FOR DAMAGE. ALL GAS LEAKS AND WIRING MUST BE REPAIRED PRIOR TO FUTURE USE.
WARNING: NEVER cover more than 75% of the cooking surface with griddles or pans. Overheating will occur,
and burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The unit serial identifi cation number and rating label are located on the inside of the control panel.
The unit must be completely cool before opening.
ELECTRICAL CONNECTIONS
A 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire receptacle (not included) is required within the vicinity of the unit to provide power to it. The GFCI receptacle must be a WEATHER-PROOF IN-USE COVERED RECEPTACLE.
• Observe the National Electric Code and all local codes.
• Verify proper polarity of the receptacle.
• If an extension cord is used, ensure it is a 3-wire GROUNDED cord that is rated for the power of the equipment, and is approved for outdoor use with a W-A marking. DO NOT use 2-prong adapters.
• DO NOT TAMPER WITH THE EXTENSION CORD OR THE UNIT POWER-SUPPLY CORD.
Important: ONLY REPLACE THE OVEN LIGHTS WITH 12V / 10 WATT HALOGEN BULB(S).
4
GAS SAFETY INFORMATION
WHEN OPERATING THIS GAS APPLIANCE, ALL INSTRUCTIONS AND WARNINGS MUST BE OBSERVED. FAILURE TO DO SO MAY RESULT IN A FIRE OR EXPLOSION CAUSING PROPERTY DAMAGE, BODILY INJURY, OR DEATH.
WARNING
This gas appliance, its enclosure, and the propane cylinder enclosure, if any, MUST be plumbed and vented in accordance with local building and safety codes and should be approved by local code enforcement offi cials. This appliance MUST be installed and operated according to the information below.
FAILURE TO PROPERLY VENT THE ENCLOSURE MAY RESULT IN A FIRE OR EXPLOSION CAUSING PROPERTY DAMAGE, BODILY INJURY, OR DEATH.
A leaking gas connection or valve unintentionally left open will create a hazard.
WHEN USING PROPANE GAS
• Propane gas (also known as L.P. gas) is heavier than air and will accumulate or pool in an inadequately
vented enclosure or recessed area.
• If a pool of propane gas is ignited, an explosion will occur. Adequate venting at the fl oor level, or the lowest
point where gas could accumulate, will eliminate this danger. Refer to the ENCLOSURE / VENTILATION REQUIREMENTS section.
Observe all local codes.
• DO NOT store a spare propane-gas cylinder under or near the enclosure.
WHEN USING NATURAL GAS
• Natural gas is lighter than air and will accumulate at the top of an inadequately vented enclosure.
• If an accumulation of natural gas is ignited, an explosion will occur. Adequate venting at the top of the
enclosure, or the highest point where gas could accumulate, will eliminate this danger. Refer to the ENCLOSURE / VENTILATION REQUIREMENTS section.
Observe all local codes.
INSTALLATION SAFETY GUIDELINES
THIS UNIT MUST BE INSTALLED SO THAT THE REQUIRED VENT OPENINGS AND SURROUNDING AREA OF THE ENCLOSURE REMAIN CLEAR AND FREE AT ALL TIMES. See the ENCLOSURE / VENTILATION REQUIREMENTS section for details.
CAUTION: FOR YOUR SAFETY, you must provide openings in the enclosure for replacement air and
ventilation (in case of possible leakage from gas connections or propane cylinders). Failure to do so may result in a fi re or explosion causing property damage, bodily injury, or death. See the ENCLOSURE / VENTILATION REQUIREMENTS section for details.
The gas cylinder, regulator, and rubber hose must be in a location not subject to temperatures above 125° F (51° C).
IF A PROPANE CYLINDER IS INSTALLED INSIDE OF THE ENCLOSURE, THE GUIDELINES FOUND IN THE
ENCLOSURE / VENTILATION REQUIREMENTS SECTION MUST BE FOLLOWED.
OPERATING THE UNIT SAFELY AND CORRECTLY
Every time you use the unit, make sure that:
1. The area around the enclosure is clear and free from combustible materials, gasoline and fl ammable vapors/
liquids.
2. There is no blockage of the airfl ow through the vent openings located on the enclosure.
3. The hose is inspected (if applicable). See SAFE USE & MAINTENANCE OF PROPANE-GAS CYLINDERS section.
DO NOT store any combustible materials, gasoline, and any other fl ammable vapors/liquids in the vicinity of the
unit. Provide adequate clearance for servicing and operation.
5
U
L
UTILISATION SÛRE ET ENTRETIEN DES CYLINDRES DE GAZ DE PROPANE
IMPORTANT POUR VOTRE SÛRETÉ
LISEZ ET SUIVEZ TOUS LES AVERTISSEMENTS ÉQUIPÉS DE VOTRE CYLINDRE DE GAZ DE PROPANE.
En actionnant cet appareil avec un cylindre de gaz de propane ON DOIT observer ces instructions et avertissements.
LE MANQUE DE FAIRE AINSI PEUT AVOIR COMME CONSÉQUENCE UNE INCENDIE OU UNE EXPLOSION SÉRIEUSE.
CYLINDRE ET CONDITIONS ET CARACTÉRISTIQUES DE CONNECTEUR
a. Des cylindres et les valves de gaz de propane doivent être
maintenus en bon état et doivent être remplacés s’il y a des dommages évidents au cylindre ou à la valve.
b. Ce gril, une fois utilisé avec un cylindre, devrait être relié à
un gallon de la norme 5 (20lb.) cylindre de gaz de propane équipé d’un OPD (remplissez au-dessus du niveau le dispositif d’empêchement). L’OPD a été exigé sur tous les cylindres vendus depuis octobre 1.1998 pour empêcher le remplissage excessif.
c. Les dimensions de cylindre devraient être approximativement
12"(30.5cm) de diamètre et 18" (45.7cm) hauts. Des cylindres doivent être construits et marqués selon les caractéristiques pour des cylindres de gaz de propane du département des ETATS-UNIS du transport (D.O.T.) ou le niveau national du Canada, du CAN/CSA-B339, des cylindres, des sphères et des tubes pour le transport des marchandises dangereuses.
d. Le cylindre doit inclure un collier pour protéger la valve
de cylindre et le circuit d’alimentation de cylindre doit être assuré le retrait de vapeur.
e. Le montage du régulateur de pression et le fl exible (Fig. 6-1)
e. Le régulateur de pression et l’ensemble de tuyau utilisé
fourni avec cet appareil au gaz en plein air (modèles au
doivent assortir les spécifi cations pour le type I par ANSI
propane seulement) doit être utilisé. Assemblées d'origine et
Z 21.58/CGA 1.6 (voir la fi gue. 6-1).
régulateur de pression et le tuyau de remplacement doivent être ceux spécifi és par le fabricant pour le raccordement d'un dispositif de cylindre de liaison identifi ée comme de type I par le ANSI Z 21.58/CGA 1.6 (voir liste des pièces pour les informations de commande).
f. La valve de cylindre de gaz de propane doit être équipée
d’un dispositif d’accouplement de raccordement de cylindre, décrit comme type I dans la norme défi nie dans le e. de paragraphe ci-dessus. Ce dispositif est généralement décrit comme coupleur rapide de fi l de point culminant.
g. Si votre cylindre de gaz de propane vient avec une prise
de la poussière, placez le bouchon anti-poussière sur la sortie de valve de cylindre toutes les fois que le cylindre n’est pas en service.
OPÉRATION DE COUPLEUR RAPIDE
Pour relier le regulator/hose à l’ajustage de précision de valve de cylindre de gaz de propane: Serrez l’écrou de main
sur le régulateur au-dessus de l’ajustage de précision de fi l de point culminant sur la valve de cylindre. Tournez l’écrou de
main dans le sens des aiguilles d’une montre pour engager les fi ls et pour serrer jusqu’à ce que douillettement. L’utilisation des pinces ou de la clé ne devrait pas être nécessaire. Seulement le propane marqué par cylindres doit être employé.
Pour débrancher: Tournez l’écrou de main dans le sens contraire des aiguilles d’une montre jusqu’à isolé (fi g. 6-1).
Important: Avant d’employer le gril, et ensuite chaque
fois que le cylindre est enlevé et rattaché, examinez tous les raccordements pour déceler les fuites. Arrêtez les valves de gril et ouvrez la valve principale de cylindre, puis vérifi ez les raccordements avec de l’eau savonneux. Réparez toutes les fuites avant d’allumer le gril.
ATTENTION: Tournez toujours la valve principale de cylindre
de propane au loin après chaque utilisation, et avant de déplacer le gril et le cylindre, ou débrancher l’accouplement. Cette valve doit rester fermée et le cylindre a débranché alors que l’appareil n’est pas en service, quoique l’écoulement de gaz soit arrêté par un dispositif de sûreté quand le coupleur est débranché.
Inspectez soigneusement l’ensemble de tuyau chaque fois avant que le gaz soit allumé. Un tuyau fi ssuré ou effi loché doit être immédiatement remplacé.
Si l'appareil est stocké à l'intérieur, le cylindre doit être disconnected et a enlevé. Des cylindres Disconnected doivent être stockés dehors, hors de la portée des enfants, avec les prises de valve fi letées étroitement installées, et ne doivent pas être stockés dans
un bâtiment, le garage, ou n'importe quel autre secteur inclus.
POUR VOTRE SÛRETÉ
a. Ne stockez pas un cylindre de gaz disponible de propane
dessous ou ne vous approchez pas de cet appareil.
b. Ne remplissez jamais cylindre au delà de 80 pour cent de
plein.
c. SI L’INFORMATION DANS “A” ET “B” N’EST PAS SUIVIE
EXACTEMENT, UN FEU CAUSANT LA MORT OU DES DOMMAGES SÉRIEUX PEUT SE PRODUIRE.
Fig. 6-1 type coupleur rapide de fi l de point culminant d’I
Volant de commande
QCC Type 1
Valve
Valve de décompression
1
Ajustage de précision en laiton de fi l de point culminant
4
Indicateur de niveau de liquide (facultatif)
3
2
Écrou de main avec le fi l de point culminant.
Régulateur
Passage
Tuy au
Pour les besoins de ventilation et d'enceinte au propane,
Voir la section ENCLOSURE / VENTILATION REQUIREMENTS.
6
U
L
SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS
IMPORTANT FOR YOUR SAFETY
READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE-GAS CYLINDER.
When operating this appliance with a propane-gas cylinder, these instructions and warnings MUST be observed.
FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION.
CYLINDER/CONNECTOR REQUIREMENTS
a. Propane-gas cylinders, valves, and hoses must be
maintained in good condition and must be replaced if there is visible damage to either the cylinder or valve. If the hose is cut or shows excessive abrasion or wear, it must be replaced before using the gas appliance (see e.).
b. This unit, when used with a cylinder, should be connected
to a standard 5-gallon (20 lb.) propane-gas cylinder equipped with an OPD (Overfi ll Prevention Device). The OPD has been required on all cylinders sold since October 1,1998, to prevent overfi lling.
c. Cylinder dimensions should be approximately 12" (30.5
cm) in diameter and 18" (45.7 cm) high. Cylinders must be constructed and marked in accordance with the
Specifi cations for Propane Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres, and Tubes for Transportation of Dangerous Goods.
d. The cylinder used must include a collar to protect the
cylinder valve, and the cylinder supply system must be arranged for vapor withdrawal.
e. The pressure regulator and hose assembly used must
e. The pressure regulator and hose assembly (Fig. 7-1)
match the specifi cation for Type I by ANSI Z 21.58/CGA
supplied with this outdoor gas appliance (L.P. models
1.6 (see Fig. 7-1).
only) must be used. Original and replacement pressure regulator and hose assemblies must be those specifi ed by the manufacturer for connection with a cylinder connecting device identifi ed as Type I by the ANSI Z 21.58/CGA 1.6 (see PARTS LIST for ordering information).
f. The propane-gas cylinder valve must be equipped with a
cylinder connection coupling device, described as Type I in the standard defi ned in paragraph e. above. This device is commonly described as an Acme thread quick coupler.
g. If the propane-gas cylinder comes with a dust plug, place
the dust cap on the cylinder valve outlet whenever the cylinder is not in use.
QUICK COUPLER OPERATION
To connect the regulator/hose assembly to the propane­gas cylinder valve fi tting: Press the hand nut on the regulator
over the Acme thread fi tting on the cylinder valve. Turn the hand nut clockwise to engage the threads and tighten until snug.
The use of pliers or a wrench should not be necessary. Only cylinders marked “propane” may be used.
To disconnect: Turn the hand nut counterclockwise until detached (Fig. 7-1).
Important: Before using the unit, and after each time the
cylinder is removed and reattached, check the hose for wear (see a.) and check all connections for leaks. Turn off the unit valves and open the main cylinder valve, then check connections with soapy water. Repair any leaks before lighting the unit.
CAUTION: Always turn the propane cylinder main valve
off after each use, and before moving the unit and cylinder or disconnecting the coupling. This valve must remain closed and the cylinder disconnected while the appliance is not in use, even though the gas fl ow is stopped by a safety feature when the coupler is disconnected.
Carefully inspect the hose assembly each time before the gas is turned on. A cracked or frayed hose must be replaced immediately.
If the appliance is stored indoors, the cylinder must be disconnected and removed. Disconnected
cylinders must be
stored outdoors, out of the reach of children, with threaded valve plugs tightly installed, and must not be stored in a
building, garage, or any other enclosed area.
FOR YOUR SAFETY
a. DO NOT store a spare propane-gas cylinder under or
near this appliance.
b. NEVER fi ll the cylinder beyond 80-percent full. c. IF THE INFORMATION IN a. AND b. IS NOT FOLLOWED
EXACTLY, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
Fig. 7-1 Type I Acme thread quick coupler
QCC Type 1 valve
Pressure relief valve
Hand wheel
Brass Acme thread fi tting
Liquid level indicator (optional)
Hand nut with Acme thread
Regulator
Vent
Hose
For propane ventilation and enclosure requirements,
see the ENCLOSURE / VENTILATION REQUIREMENTS section.
7
Min. 90˚
ENCLOSURE / VENTILATION REQUIREMENTS
When installing this unit in a combustible enclosure, the correct air gap requirement must be met.
Fire Magic GFRC islands are available. They meet all enclosure and ventilation requirements. For requirements regarding custom-built enclosures, see below.
VENTILATION (ALL ENCLOSURES)
For All Piping Systems and All Gas Types: (Natural Gas, Household Propane, L.P. Cylinder)
FOR YOUR SAFETY, you must provide the openings listed below for replacement air and ventilation of the enclosure (in case of possible leakage from gas connections or L.P. cylinders). Failure to do so may result in a fi re or explosion causing property damage, bodily injury, or death.
One side of the enclosure shall be left completely open to the outside; OR 4 (minimum) ventilation openings MUST be created (reference Fig. 8-1 and Fig. 8-2):
• Each opening must have a minimum of 10 sq. in. of free area. The openings must be equally sized.
• Two openings must be in the side walls of the enclosure, at the top level, and spaced at a minimum of 90 degrees. The openings must begin 1" or less below the countertop level and end no more than 5" below the countertop level.
• Two openings must be in the side walls of the enclosure, at the fl oor level, and spaced at a minimum of 90 degrees. The openings must begin 1" or less above the fl oor level and end no more than 5" above the fl oor level.
Ventilation Requirements:
• Minimum 4 openings (2 per side wall - spaced at min. 90 degrees)
• Top openings: within 5" of countertop (see below)
• Bottom openings: within 5" of fl oor (see below)
• Each vent opening: min. 10 sq. in. of free area
1"
max.
Vent openings (4)
10 sq. in. of free area min. (each)
1"
max.
Note: Vent openings example shown. Your design may vary.
5"
max.
5"
max.
Keep surrounding
area and vent
openings clear and
free at all times.
Fig. 8-1 Ventilation detail
• 6" min. clearance between all vent openings and any items outside of enclosure
• 2" min. clearance between all vent openings and any items within enclosure
• The openings must remain unobstructed:
The clearance between the openings and any items outside of the enclosure is a minimum of 6". The clearance between the openings and any items within the enclosure is a minimum of 2". See Fig. 8-2.
When an L.P. cylinder is used in the enclosure, additional requirements exist, see the following section.
It is acceptable to use RHP venting panels (PN 5510-01). Contact your dealer.
KEEP THE REQUIRED VENT OPENINGS AND SURROUNDING AREA OF THE ENCLOSURE CLEAR AND FREE AT ALL TIMES.
WARNING: Ventilation openings in side walls shall not
communicate directly with other enclosures of the outdoor cooking gas appliance.
6"
min.
Vent
opening
2"
min.
(Side View)
Fig. 8-2 Vent openings clearance
8
ENCLOSURE / VENTILATION REQUIREMENTS (cont.)
WHEN A PROPANE (L.P.) CYLINDER IS USED IN THE ENCLOSURE
When a propane (L.P.) cylinder is installed inside of the enclosure, the guidelines below MUST be followed. FAILURE TO DO SO MAY CAUSE DAMAGE TO YOUR UNIT AND/OR PERSONAL INJURY. Reference Fig. 9-1 and 9-2 for an example.
• Only a C.S.A. listed stainless steel connector can be connected to the unit.
• The regulator/hose assembly coming from the cylinder can only be connected to the above mentioned fl ex connector. DO NOT connect the regulator/hose assembly directly to the unit. An adapter will be required.
• A non-combustible heatshield must be installed to protect the regulator/hose assembly and cylinder valve.
• The cylinder must rest at least 2" above the ground.
• An additional vent opening is recommended in the access door near the cylinder and at the gas connection level (minimum 10 sq. in. of free area).
RHP offers an "access door with tank tray and louvers" which includes a heatshield that rests directly above the L.P. cylinder, a tray, and louvers to meet the cylinder install requirements. The door is shown in Fig. 9-3. Contact your dealer for ordering information.
C.S.A.
listed stainless steel fl ex
connector
Fig. 9-1 L.P cylinder orientation
Sideburner
Adapter
L.P.
cylinder
Non-combustible
Heatshield
Regulator/
hose
assembly
L.P.
cylinder
2" min. from ground
Ventilation
opening
(at cylinder gas
connection level,
min. 10 sq. in
free area)
Access
door
(L.P. Cylinder setups only)
Fig. 9-2 Additional ventilation opening for L.P. cylinder
RHP DOOR MEETS ALL REQUIREMENTS ABOVE
Cylinder & regulator/hose assembly
protected by heatshield
Louvers
Equipped with
adapter for hose
assembly.
Flex connector
not included.
Tray
Additional adapters may be required
for your setup (not included)
Fig. 9-3 Optional RHP door w/ tank tray & louvers
9
INSTALLATION REQUIREMENTS
Installation must be performed by a qualifi ed professional service technician.
This unit is designed for outdoor use only. DO NOT use this unit inside a building, garage, or enclosed area. DO NOT use this unit in or on a recreational vehicle or boat.
The unit must have a minimum clearance of 18" from combustible materials/items in all directions.
OVERHEAD CONSTRUCTION REQUIREMENTS
A minimum 5 foot clearance is required between the countertop and the overhead construction.
W
OVERHEAD CONSTRUCTION
N O N
C O M B U S T
I B L E
A L L
Min.
5'
Fig. 10-1 Overhead requirements
10
INSTALLATION REQUIREMENTS (Cont.)
SIDE AND REAR WALL CLEARANCES
For the minimum clearances between the unit and any side or rear walls, your setup must fall within one (or more) of the following:
A. Clearance between unit and strictly non-combustible
wall
(i.e. brick wall, see Fig. 11-1)
• The unit must have a minimum of 4" right, left, and rear clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous overheating.)
B. Clearance between unit and a protected combustible
wall
(i.e. a non-combustible wall in front of a combustible wall to serve as a barrier. This can be accomplished by brick, or a metal stud fi nished with non-combustible substrate, see Fig. 11-2)
• The unit must have a minimum of 14" right, left, and rear clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional 10" clearance between the unit and protected wall.)
C. Clearance between unit and combustible wall
Non-combustible
Min.
4"
(Clearance required for
right, left, and rear)
Fig. 11-1 Clearance 'A' Diagram
Non-combustible
substrate
(Clearance required for
right, left, and rear)
Non-combustible 4"
Min.
14"
Fig. 11-2 Clearance 'B' Diagram
Combustible
Com-
bustible
• The unit must have a minimum of 18" right, left, and rear clearance from any combustible wall (see Fig. 11-3).
BACKSPLASH CLEARANCE (if applicable)
If a non-combustible backsplash exists, it must have a minimum of a 4" clearance from the rear of the unit (to allow for proper ventilation and prevent dangerous overheating). See Fig. 11-4.
Important: This 4" backsplash clearance must fi rst be met
prior to any non-combustible walls beginning behind it.
Min.
18"
(Clearance required for
right, left, and rear)
Fig. 11-3 Clearance 'C' Diagram
Non-combustible
Backsplash
Min.
4"
Fig. 11-4 Backsplash clearance
11