Fire Magic Echelon Diamond Built-In Grill User Manual

ECHELON
diamond series
OUTDOOR BUILT-IN GAS GRILL
E660i, E790i, and E1060i
INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR USE.
E790i shown
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or the fi re department.
CODE AND SUPPLY REQUIREMENTS: This grill must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with the latest National Fuel Gas Code (ANSI
Z223.1/NFPA 54), or Natural Gas and Propane Storage and Handling Installation Code (CSA­B149.1).
This appliance and its dedicated manual shutoff valve must be disconnected from the gas-supply piping system when testing the system at pressures in excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gas­supply piping system by closing its dedicated manual shutoff valve during any pressure testing of the gas-supply system at pressures up to and including ½ psig (3.5 kPa).
1. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. For proper installation, refer to the installation instructions. For assistance or additional information, consult a qualifi ed professional installer,
service agency, or the gas supplier.
All electrical outlets in the vicinity of the grill must be properly grounded in accordance with local codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever
is applicable. Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
WARNING:
WARNING:
Proper operation of your grill requires prompt and periodic maintenance. See the CARE & CLEANING section for details.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 5 - 1412081445
Certifi ed to: ANSI Z21.58b-2012 CSA 1.6b-2012
10-32
1
L-C2-329
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
GRIL EXTÉRIEUR D’ÎLE DE GAZ D’ÉCHELON
IMPORTANT: LISEZ CES INSTRUCTIONS SOIGNEUSEMENT AVANT DE COMMENCER L’INSTALLATION OU L’UTILISATION
SÛRETÉ ET CODES D’AVERTISSEMENT
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez le gaz à l’appareil.
2. Éteignez-vous n’importe quelle fl amme nue.
3. Ouvrez le couvercle si équipé d’un four.
4. Si l’odeur continue, gardez loin de l’appareil et appelez immédiatement votre département de fournisseur ou de feu de gaz.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre le plus défunt Code national de gaz de carburant (norme ANSI Z223.1/NFPA 54), et Stockage de gaz naturel et de propane et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être démontés du gaz-fournissent le système siffl ant en examinant le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système siffl ant par fermeture que ses différents robinets d’isolement manuels pendant tous les essais sous pression du gaz­fournissent le système aux pressions jusques et y compris le ½ psig (kPa 3.5).
• Ce gril est pour ultilisation à l’extérieur seulement. Si l’appareil est entreposé à l’intérieur, enlever les bouteilles et les laisser à l’extérieur.
• Ne pas ranger le gril immédiatement aprés l’avoir utilisé. le laisser refroidir avant de le déplacer ou de la ranger. Le non respect de cette mesure de sécurité pourrait entraîner un incendie causant des dommages à la propriété, des blessures ou la mort.
• Ne pas utiliser cet appareil sous une surface combustible.
• Ne pas utiliser cet appareil sous un auvent. Le non respect de cette mesure de sécurité pourrait entraîner un incendie ou des blessures.
• Dégagement minimal entre les parois latérales et l’arriére de l’appareil et la construction combustible (45.7 cm à partir des parois latérales et 45.7cm à partir de l’arriére).
• Le régulareur de pression de gaz prévu avec cet appareil de cuisson à gaz pour l’extérieur doit être utilisé. Ce régulateur est réglé pour une pression de sortie de 5 pouces de colonne de l’eau pour le gaz naturel, et 10 pouces pour le propane.
• LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE CARRÉ). SI VOTRE OFFRE DE GAZ EST 1/2 PLUS GRAND QUE (LIVRES PAR POUCE CARRÉ), UN
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas l’essence ou d’autres vapeurs et liquides infl ammables à proximité de ceci ou d’aucun autre appareil.
2. Un cylindre de propane non relié pour l’usage ne sera pas stocké à proximité de ceci ou d’aucun autre appareil.
AVERTISSEMENT:
L’installation inexacte, l’ajustement, le changement, le service, ou l’entretien peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour l’aide ou l’information additionnelle, consultez un installateur professionnel qualifi é, l’agence de service,
ou le fournisseur de gaz.
Toutes les sorties électriques à proximité du gril doivent être correctement fondues selon des codes locaux, ou en l’absence de local code, avec le code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui est applicable.
Maintenez tout électrique-fournissent des cordes et carburant­fournissent des tuyaux partis de n’importe quelle surface de chauffage.
RÉGULATEUR ADDITIONNEL DOIT ÊTRE INSTALLÉ AVANT LE GRIL. VOIR LA SECTION DE CONDITIONS D’OFFRE DE GAZ POUR LA PRESSION APPROPRIÉE D’OFFRE DE GAZ.
• Ne couvrez jamais la surface entière de cuisine ou de gril de gauffreuses ou de casseroles. La surchauffe se produira et les brûleurs ne seront pas très performants quand la chaleur de combustion est emprisonnée au­dessous de la surface à cuire.
• Ne pulvérisez jamais l’eau sur une unité chaude de gaz, comme ceci peut endommager des composants de porcelaine ou de fer de fonte.
• Une fuite de GPL peut causer une incendie ou une explosion si enflammée entraînant des blessures corporelles graves ou la mort.
• Communiquez avec le fournisseur de GPL pour les réparations ou pour disposer de qules bouteille ou du GPL non utilisé.
Certifi é à la norme ANSI : Z21.58b-2012 / CSA 1.6b-2012
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
REV 5 - 1412081445
2
L-C2-329
CONTENTS
4 REPLACEMENT PARTS LIST 7 COUNTERTOP OVERHANG 7 MODEL SPECIFICATIONS 8 SUBSTRATE 8 BUILT-IN GRILL DIMENSIONS TABLE 9 BUILT-IN GRILL WIRING DIAGRAM 10 ELECTRICAL CONNECTIONS 10 GRILL MAINTENANCE AND SAFETY INFORMATION 10 MASTER SWITCH 11 INSTALLATION REQUIREMENTS 12 ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW 12 EXHAUST REMOVAL 12 GAS-SUPPLY PLUMBING REQUIREMENTS 13 NATURAL GAS INSTALLS 13 PROPANE GAS INSTALLS (HOUSEHOLD & CYLINDER) 13 WHEN A PROPANE CYLINDER IS USED 13 ENCLOSURE REQUIREMENTS 14 COUNTER PREPARATION 14 CONNECT THE GAS SUPPLY 14 INSTALLATION 15 INSTALL ZONE DIVIDERS 16 ELECTRICAL INSTALLATION 17 SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS 19 IDENTIFICATION OF GRILL CONTROLS 20 OPTIONAL POWER HOOD 21 LIGHTING (IGNITION) INSTRUCTIONS 21 SHUTTING OFF THE UNIT 23 DIGITAL THERMOMETER / INTERIOR AND KNOB LIGHTS 26 ROTISSERIE INSTRUCTIONS 27 INFRARED BURNER OPERATION 28 GRILLING TIPS 29 ACCESSORIES 30 FIRE MAGIC 31 CARE & CLEANING 32 REPLACING HALOGEN BULBS 33 POWER SUPPLY FUSE REPLACEMENT 34 REGULATOR CONVERSION 34 GAS ORIFICE CONVERSION 34 CONVERTING THE GAS TYPE 37 BURNER AIR SHUTTER ADJUSTMENT 38 CONTROL PANEL REMOVAL 39 TROUBLESHOOTING 40 WARRANTY
®
DRIP TRAY
REV 5 - 1412081445
3
L-C2-329
REPLACEMENT PARTS LIST
1
15
17
16
14
10
13
21
11
22
10
23
19
20
5
9
2
4
6
3
12
9
7
45
54
Some items shown are optional, or are not available for certain models. Your model may vary, refer to parts list.
To order replacement parts, contact your local Fire Magic® dealer.
24
26
25
41
30
Items in light gray are not available on all models.
28
48
27
18
52
29
46
47
Fig. 4-1
REV 5 - 1412081445
4
L-C2-329
REPLACEMENT PARTS LIST (Cont.)
E660i E790i E1060i
Item Description Part No. Qty. Part No. Qty. Part No. Qty.
Stainless cooking grid (set of 2 or 3) 3544-S-3 1 3539-S-3 1 23539-S-2 2
1.
Flavor grid (set of 3 or 4) 3057-S-3 1 3056-S-3 1 3056-S-4 1
2.
Main burner 3041-50 3 3041-50 3 3041-50 4
3.
Heatshield kit 24177-05 3 24177-05 3 24177-05 4
4.
Silicone gasket 24177-06 3 24177-06 3 24177-06 4
5.
Infrared burner * 3050 1 3050 1 3050 1
6.
Oven lid 23738-53 1 23745-53 1 23747-53 1
7.
Oven lid w/ window 24193-54 1 24188-54 1 24183-54 1
or
Window (only) *‡ 24187-45 1 24187-45 1 24187-45 1
8.
Warming rack 36735-M 1 36755-M 1 36745-M 1
9.
Back burner assembly 24794-02 1 24789-02 1 24784-02R/L 1
10.
Back burner cover 24794-010 1 24789-010 1 24784-010 2
11.
Zone separator 3061-S 2 3061-S 2 3061-S 3
12.
Heavy-duty rotisserie motor 3600-05M 1 3600-05M 1 3600-05M 1
13.
Heavy-duty rod 3606-40 1 3609-40 1 3607-40 1
14.
Heavy-duty rod knob 24187-16 1 24187-16 1 24187-16 1
15.
Meat holder (pair) 3613 1 3613 1 3613 1
16.
Counterbalance 3620E 1 3620E 1 3620E 1
17.
Grid lifter 3519 1 3519 1 3519 1
18.
Convertible regulator PR-4 1 PR-4 1 PR-4 1
19.
Valve manifold w/ back burner 24193-22 1 24188-22 1 24183-22 1
20.
Control panel w/ back burner and raceway † 24194-10 1 24189-10 1 24184-10 1
21.
Control panel w/ back burner, raceway, and
or
wire harness †
Small knob 24182-42 1 24182-42 1 24182-42 2
22.
Large knob 24182-41 3 24182-41 3 24182-41 4
23.
LED disk (small) 24182-64 1 24182-64 1 24182-64 2
24.
LED disk (large) 24182-63 3 24182-63 3 24182-63 4
25.
Digital thermometer 24182-12 1 24182-12 1 24182-12 1
26.
Meat probe 24187-14S 1 24187-14S 1 24187-14S 1
27.
Power supply w/ connector † 24187-18 1 24187-18 1 24187-18 1
28.
24194-12 1 24189-12 1 24184-12 1
REV 5 - 1412081445
* If equipped ‡ Not shown
† Add (M) to part number for power hood
5
L-C2-329
REPLACEMENT PARTS LIST (Cont.)
E660i E790i E1060i
Item Description Part No. Qty. Part No. Qty. Part No. Qty.
Drip tray 3087 1 3087 1 3087 1
29.
Drip tray liner (set of 4) 3557 1 3557 1 3557 1
30.
Wire harness for raceway ‡ 24194-47 1 24189-47 1 24184-47 1
31.
Back burner electrode *‡ 4199-52 1 4199-52 1 4199-52 2
32.
Electrode ‡ 3199-72 3 3199-72 3 3199-72 4
33.
Thermometer wire harness ‡ 24187-13 1 24187-13 1 24187-13 1
34.
Natural gas orifi ce(s) ‡ 3001-42-3 1 3001-38-3 1 3001-40-4 1
35.
Natural back burner gas orifi ce(s) ‡ 3001-53-1 1 3001-51-1 1 3001-53-2 1
36.
Propane gas orifi ce(s) ‡ 3001-54-3 1 3001-53-3 1 3001-53-4 1
37.
Propane back burner gas orifi ce(s) ‡ 3001-63-1 1 3001-57-1 1 3001-63-2 1
38.
Natural smoker orifi ce ‡ 3003-68-1 1 3003-68-1 1 3003-68-1 1
39.
Propane smoker orifi ce ‡ 3003-77-1 1 3003-77-1 1 3003-77-1 1
40.
Wood chip box assembly 24182-45 1 24182-45 1 24182-45 1
41.
12V / 10 watt halogen light bulb ‡ 24187-15 2 24187-15 2 24187-15 3
42.
Light lens ‡ 24187-26 2 24187-26 2 24187-26 3
43.
Lamp assembly ‡ 24187-28 2 24187-28 2 24187-28 3
44.
Power hood motor assembly * 24183-18 1 24183-18 1 24183-18 1
45.
Power hood rocker switch* 24187-39 1 24187-39 1 24187-39 1
46.
Lighted master shut-off switch 24182-46 1 24182-46 1 24182-46 1
47.
Light microswitch 24187-20 1 24187-20 1 24187-20 1
48.
Power hood light & motor microswitch 24187-44 1 24187-44 1 24187-44 1
or
Flash tube (left) ‡ 24187-29 1 24187-29 1 24187-29 1
49.
Flash tube (right) ‡ 24187-35 2 24187-35 2 24187-35 3
50.
Flex connector ‡ 3030-08 1 3030-08 1 3030-08 1
51.
Support screw (set of 2) 24182-47 1 24182-47 1 24182-47 1
52.
Fire Magic® cookbook ‡ 3595 1 3595 1 3595 1
53.
Wire harness extension 24182-53 1 24182-53 1 24182-53 1
54.
REV 5 - 1412081445
* If equipped ‡ Not shown
6
L-C2-329
MODEL SPECIFICATIONS
MODEL SPECIFICATIONS TABLE
Countertop
Main burner quantity N/P orifi ce drill size
Back burner quantity N/P orifi ce drill size
Smoker drawer burner N/P orifi ce drill size
Infrared searing burner N/P orifi ce drill size
Table 1
E660i E790i E1060i
3
#42 / #543#38 / #534#40 / #53
1
#53 / #631#51 / #572#53 / #63
#68 / #77 #68 / #77 #68 / #77
#45 / #55 #45 / #55 #45 / #55
Echelon insulating liner model # (not included)* 3176-50 3186-50 3185-50 Power Supply Rating Oven Lights Rating
12V / 10 watt halogen light bulb
120VAC / 1.5A / 60 Hz
A Countertop to unit bottom cut-out* 12" 12" 12"
1
B Side to side non-combustible cut-out* 31-
/4" 37" 50"
C Front to back non-combustible cut-out*† 23-1/2" 23-1/2" 23-1/2" D Control panel width non-combustible cut-out 33" 38-3/4" 51-3/4"
If equipped
* Note: If installing this grill in a combustible enclosure, the correct insulating liner must be used. Consult liner instructions for
counter cut-out dimensions and installation.
Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See SUBSTRATE
section on next page.
Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section below).
TOP VIEW
B
NON-COMBUSTIBLE
Extra cut-out
for Power
Hood only!
TOP VIEW
(Countertop)
X
7
X=
/8"
Y= Total Countertop Overhang
ENCLOSURE CUT-OUT
C
DIMENSIONS
Lower support
Control panel
D
1-1/4" x 10"
11"
Countertop overhang
(Control
panel)
Y
1
/4"
Clearance
(Overhang)
Check clearance for
control panel removal
FRONT VIEW
SIDE VIEW
A
See next page
for substrate
considerations
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends beyond the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.
Countertop overhang
Control
panel
Countertop
overhang
Fig. 7-1
Important: FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and
cross-ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane tanks. See the ENCLOSURE REQUIREMENTS section for details.
REV 5 - 1412081445
7
L-C2-329
MODEL SPECIFICATIONS (cont.)
SUBSTRATE
When adding any substrate to the enclosure front wall (including tiles, stone, etc.), consider the following:
Substrate Behind Control Panel
Substrate + countertop "front to back" cutout must equate to Dim. C (see previous page) when the substrate sits fl ush behind the control panel.
TOP VIEW TOP VIEW
(Countertop)
Substrate
(includes tiles,
etc. at front of
enclosure)
Grill liner
(Control panel)
C
Flush
Countertop
(if applicable)
/4"
overhang
1
Clearance
Fig. 8-1 Fig. 8-2
Substrate Alongside Control Panel
Any additional substrate alongside the control panel does not need to be considered in Dim. C (see previous page), however a overhang) and below is required.
1
/4" clearance on each side (same as
Grill liner
Flush
(Control panel)
(Countertop)
(includes tiles,
etc. at front of
C
1
/4"
Clearance
Substrate
enclosure)
Countertop
overhang
(if applicable)
Model
E660i E790i
E1060i
G
BUILT-IN GRILL DIMENSIONS TABLE
Height Width Depth
(Top to bottom) (Left to right) (Front to
back)
Upper hanger to top
Hanger to
hanger
(G)
Open
(E)
(with oven)
Closed
(F)
23-5/8" 15" 36-1/4" 32-1/2" 29-3/4" 23-5/8" 15" 42" 38-1/4" 29-3/4"
23-5/8" 15" 54-7/8" 51-1/4" 29-3/4"
E
Control
panel
width
(H)
Maximum
depth
(I)
I
F
REV 5 - 1412081445
H
Fig. 8-3
8
L-C2-329
MODEL SPECIFICATIONS (cont.)
BUILT-IN GRILL WIRING DIAGRAM*
Left oven
light
Back
burner
Backburner
igniter
Main
burner 4
Main burner igniters
Valve
manifold
Main
burner 3
Center oven
light
Main
burner 2
Smoker
igniter
Smoker
burner
Backburner
Wire harness
Main
burner 1
igniter
assembly
burner
Back
Right oven
light
Ground
Wire
Master switch
Oven light
micro switch
(not used for
Magic View)
Meat
probe
jack
LED disc
(small)
Thermocouple
LED disc
(large)
Power supply
Digital
Thermometer
wire harness
E1060i model shown. Model wire diagrams may vary.
*
thermometer
Note: In addition, a wire diagram specifi c to your unit
can be found affi xed to the inside of the control panel.
For Magic View only
Wire harness
extension
REV 5 - 1412081445
9
L-C2-329
GRILL MAINTENANCE AND SAFETY INFORMATION
1. The outdoor grill and surrounding area MUST
remain clear of fl ammable substances such as gasoline, yard debris, wood, etc.
2. The airfl ow through the vent space located below
the control panel must remain unobstructed.
3. When using propane gas: a. The required ventilation openings in the
enclosure must be clear of debris.
lead to a fi re beneath the grill. A proper fl ame pattern will ensure safe operation and optimal performance. Adjust the air shutter as needed (see AIR SHUTTER ADJUSTMENT).
5. The in-line gas valve or gas cylinder valve must
always be shut OFF when the grill is not in use.
6. The drip collector holes must be clear and
unobstructed. Excessive grease deposits can result in a grease fi re.
b. The propane cylinder, regulator, and rubber
hose must be in a location not subject to temperature above 125° F (51° C).
4. The fl ames on each burner burn evenly along
the entire burner with a steady fl ame (mostly blue). If burner fl ames are not normal, check
7. The back burner or IR burner cover must be
removed before using the burner.
8. Whenever reconnecting any wires, apply a
small amount of dielectric grease to the male connector, then make the connection.
and clean the orifi ce and burner/venturi tubes for insects and insect nests. A clogged tube can
WARNING: NEVER cover the entire cooking or grill surface with griddles or pans. Overheating will occur, and
burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The grill serial identifi cation number is located on the underside of the drip tray handle. It
is recommended that the drip tray fi rst be removed and cleaned / emptied of its contents,
then turned over to view. The unit rating label is located inside of the control panel.
ELECTRICAL CONNECTIONS
This grill requires 120VAC power to operate.
Plug the power supply cord into a properly
wired and inspected GFCI electrical receptacle (15 AMP minimum). Use a heavy-
duty grounded extension cord if necessary.
WARNING
Electrical Grounding Instructions For your protection against shock hazard, this outdoor-cooking gas-appliance is equipped with a three-pronged (grounding) electrical connector. This appliance should be connected to a properly grounded three-prong receptacle using a grounding extension cord rated for outdoor use. Do not cut or
remove the grounding prong from the connector.
MASTER SWITCH
The master switch is push button operated, and is located on the right side of the control panel (see Fig. 10-1). It controls the power to all lights, igniters, and the thermometer. It allows the power to be turned on or off for safety and convenience. The switch will need to be turned on prior to each grill use, and turned off after each use.
Important: ONLY REPLACE THE OVEN LIGHTS
WITH 12V / 10 WATT HALOGEN BULB(S).
REV 5 - 1412081445
10
Master
switch
Fig. 10-1
L-C2-329
INSTALLATION REQUIREMENTS
Installation must be performed by a qualifi ed professional service technician.
This grill is designed for outdoor use only. DO NOT use this grill inside a building, garage, enclosed area, or under an unprotected overhead combustible construction.
See below and the EXHAUST REMOVAL section on the following page for details on installing under overhead construction.
DO NOT use this grill in or on a recreational vehicle or boat. Important: If installing this grill in a combustible surround, the correct
RHP insulating liner must be used.
Important: Refer to the information below to ensure all required
clearances are met.
The grill must have a minimum clearance of 18" from combustible materials/items AT ALL TIMES.
Overhead Construction Requirements (if applicable)
Non-combustible overhead construction: A 6 foot clearance is required between the countertop and the construction above (Fig. 11-1).
Combustible overhead construction: A 6 foot clearance is required between the countertop and the construction above. A vent hood (see EXHAUST REMOVAL section) or an RHP combustible overhead protection kit is required directly above the grill. See Fig. 11-1. RHP
vent hoods and protection kits are available, contact your local dealer.
Combustible construction:
Requires vent hood or protection kit
Min.
6'
Non-combustible construction:
Okay as-is
Fig. 11-1 Overhead requirements
Non-combustible
Min.
(Clearance required for
right, left, and rear)
Fig. 11-2 Clearance 'A' Diagram
Non-combustible
substrate
Non-combustible 4"
4"
Side and Rear Wall Clearances
For the minimum clearances between the grill and any side or rear walls, your setup must fall within one (or more) of the following:
A. Clearance between grill and strictly non-combustible wall
(i.e. brick wall, see Fig. 11-2)
• The grill must have a minimum of 4" right, left, and rear clearance from any non-combustible wall. (To allow for proper ventilation and prevent dangerous overheating.)
B. Clearance between grill and a protected combustible wall
(i.e. a non-combustible wall in front of a combustible wall to serve as a barrier. This can be accomplished by brick, or a metal stud fi nished with non-combustible substrate, see Fig. 11-3)
• The grill must have a minimum of 14" right, left, and rear clearance from the protected combustible wall. (The 4" non-combustible material plus an additional 10" clearance between the grill and protected wall.)
C. Clearance between grill and combustible wall
• The grill must have a minimum of 18" right, left, and rear clearance from any combustible wall (see Fig. 11-4).
Min.
14"
(Clearance required for
right, left, and rear)
bustible
Fig. 11-3 Clearance 'B' Diagram
Combustible
Min.
18"
(Clearance required for
right, left, and rear)
Fig. 11-4 Clearance 'C' Diagram
Non-combustible
Backsplash
Com-
Backsplash Clearance (if applicable)
If a non-combustible backsplash exists, it must have a minimum of a 4" clearance from the rear of the grill (to allow for proper ventilation and prevent dangerous overheating). See Fig. 11-5.
Important: This 4" backsplash clearance must fi rst be met prior to
any non-combustible walls beginning behind it.
REV 5 - 1412081445
11
Min.
4"
Fig. 11-5 Backsplash clearance
L-C2-329
INSTALLATION REQUIREMENTS (Cont.)
The control panel MUST remain removable for servicing (see PARTS LIST).
ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW
Proper airfl ow (Fig. 12-1) MUST be maintained for the grill to perform as it was designed. If airfl ow is blocked, overheating and poor combustion will result. Do not block the 1" (2.5 cm) front air inlet along the bottom of the control panel or more than 75% of the cooking grid surface with pans or griddles.
Note: The 1" (2.5 cm)
front air space also allows access to the drip tray.
EXHAUST REMOVAL
If the grill is installed under an overhead structure that is constructed of non-combustible material: an exhaust hood is recommended. See below.
If the grill is installed under an overhead structure that is constructed of combustible material: an exhaust hood is required. See below.
Fig. 12-1 - Ventilation diagram
GAS-SUPPLY PLUMBING REQUIREMENTS
For natural gas or a household propane system, rigid
1
/2" (1.3 cm) or 3/4" (1.9 cm) black steel pipe or local code­approved pipe is required to conduct the gas supply to the unit. Contact your local gas supplier. Connect this pipe to the required C.S.A.-approved stainless-steel fl ex connector (attached). An NPT adapter has been provided
1
for
/2" pipe. DO NOT use a rubber hose within the grill
enclosure. Apply only joint compounds that are resistant to all gasses to all male pipe fi ttings except fl are fi ttings. Make sure to tighten every joint securely.
Note: If
1
/2" (1.3 cm) pipe is used with natural gas,
it should be no longer than 20' (6.1 meters).
Important: An external valve (with a removable
key) in the gas line is necessary for safety when the grill is not in use. It also provides for convenient maintenance.
Left-side hanger
Orient grill so prevailing wind blows this way.
Note: An alternative to an exhaust removing vent
hood is an RHP combustible overhead protection kit. See previous page.
When using an exhaust hood:
The cooking grid area must be covered by an exhaust hood (with a vent) larger than the cooking surface. Refer to manufacturer specifi cations. An exhaust fan with a rating of 1,000 CFM (cubic feet per minute) (472 liters per second) or more may be necessary to effectively remove smoke and other cooking by-products from the area under the hood. RHP Vent Hoods are available,
contact your local dealer. THIS UNIT MUST NOT BE LOCATED IN A FULLY
ENCLOSED AREA OF ANY KIND.
INCORRECT
Rear oven lid vent
CORRECT
Flex connector
Left-side support wall
Fig. 12-4
CAUTION: Wind blowing into or across the rear
oven lid vent (Fig. 12-2) can cause poor performance and/or dangerous overheating. Orient the grill so that the prevailing wind blows toward the front of the grill (Fig. 12-3).
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water column
1
(w.c.), minimum 5" (12.7 cm), maximum 10
/2" (26.7
cm). For propane gas - normal 11" w.c., minimum 10" (25.4 cm), maximum 13" (33 cm).
YOU MUST PROTECT
REAR OVEN VENT FROM
PREVAILING WIND
Fig. 12-2
REV 5 - 1412081445
PLACE GRILL SO PREVAILING
WIND BLOWS TOWARD FRONT
OF GRILL
Fig. 12-3
12
L-C2-329
Loading...
+ 28 hidden pages