Fire Magic AOP03 User Manual

Instructions
For Natural or Propane Gas
(Shown without cover in place)
SIDEBURNER BUILT-IN
09-41
INSTALLER: Please leave these instructions with the consumer. CONSUMER: Retain for future reference.
Model # 3281(-2)(P)
WARNINGS AND SAFETY CODES
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid if equipped.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or the fi re department.
CODE AND SUPPLY REQUIREMENTS: This outdoor gas unit must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), or Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
All electrical outlets in the vicinity of the unit must be properly grounded in accordance with local codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever
is applicable.
1. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. For proper installation, refer to the installation instructions. For assistance or additional information, consult a qualifi ed professional installer, service agency, or the
Certifi ed to: ANSI Z21.58-2007 CSA 1.6-2007
Keep all electrical supply cords and fuel supply hoses away from any heated surface.
WARNING:
WARNING:
gas supplier.
REV 6 0906230824
Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746
1
L-C2-11109
SÛRETÉ ET CODES D’AVERTISSEMENT
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
DANS LE CONTRE- DOUBLE SIDEBURNER
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez l’admission de gaz de I’appariel.
2. Éteindre toute fl amme nue.
3. Ouvrir le couvercle.
4. Si l’odeur persiste, éloignez-vous de l’appareil et appelez immédiatement le fournisseur de gaz ou le service d’incendie.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre le plus défunt Code national de gaz de carburant (norme ANSI Z223.1/NFPA 54), et Stockage de gaz naturel et de propane et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être démontés du gaz-fournissent le système siffl ant en examinant le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système siffl ant par fermeture que ses différents robinets d’isolement manuels pendant tous les essais sous pression du gaz­fournissent le système aux pressions jusques et y compris le ½ psig (kPa 3.5).
• Ce gril est pour ultilisation à l’extérieur seulement. Si l’appareil est entreposé à l’intérieur, enlever les bouteilles et les laisser à l’extérieur.
• Ne pas ranger le gril immédiatement aprés l’avoir utilisé. le laisser refroidir avant de le déplacer ou de la ranger. Le non respect de cette mesure de sécurité pourrait entraîner un incendie causant des dommages à la propriété, des blessures ou la mort.
• Ne pas utiliser cet appareil sous une surface combustible.
Ne pas utiliser cet appareil sous un auvent. Le non respect de cette mesure de sécurité pourrait entraîner un incendie ou des blessures.
Dégagement minimal entre les parois latérales et l’arriére de l’appareil et la construction combustible (45.7 cm à partir des parois latérales et 45.7cm à partir de l’arriére).
• Le régulareur de pression de gaz prévu avec cet appareil de cuisson à gaz pour l’extérieur doit être utilisé. Ce régulateur est réglé pour une pression de sortie de 5 pouces de colonne de l’eau pour le gaz naturel, et 10 pouces pour le propane.
LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE CARRÉ). SI VOTRE OFFRE DE GAZ EST 1/2 PLUS GRAND QUE (LIVRES PAR POUCE CARRÉ), UN RÉGULATEUR ADDITIONNEL DOIT ÊTRE INSTALLÉ AVANT LE GRIL. VOIR LA SECTION DE CONDITIONS D’OFFRE DE GAZ POUR
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas l’essence ou d’autres vapeurs et liquides infl ammables à proximité de ceci ou d’aucun autre appareil.
2. Un cylindre de propane non relié pour l’usage ne sera pas stocké à proximité de ceci ou d’aucun autre appareil.
AVERTISSEMENT:
L’installation inexacte, l’ajustement, le changement, le service, ou l’entretien peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour l’aide ou l’information additionnelle, consultez un installateur professionnel qualifi é, l’agence
de service, ou le fournisseur de gaz.
Toutes les sorties électriques à proximité du gril doivent être correctement fondues selon des codes locaux, ou en l’absence de local code, avec le code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui est applicable.
Maintenez tout électrique-fournissent des cordes et carburant­fournissent des tuyaux partis de n’importe quelle surface de chauffage.
LA PRESSION APPROPRIÉE D’OFFRE DE GAZ.
• Ne couvrez jamais la surface entière de cuisine ou de gril de gauffreuses ou de casseroles. La surchauffe se produira et les brûleurs ne seront pas très performants quand la chaleur de combustion est emprisonnée au-dessous de la surface à cuire.
• Ne pulvérisez jamais l’eau sur une unité chaude de gaz, comme ceci peut endommager des composants de porcelaine ou de fer de fonte.
• Une fuite de GPL peut causer une incendie ou une explosion si enfl ammée entraînant des blessures corporelles graves ou la mort.
• Communiquez avec le fournisseur de GPL pour les réparations ou pour disposer de qules bouteille ou du GPL non utilisé.
Certifi é à la norme: ANSI Z21.58-2007 CSA 1.6-2007
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
REV 6 0906230824
2
L-C2-11109
DOUBLE SIDEBURNER PARTS LIST
Item Description
Item Description
1. STAINLESS STEEL COVER
1. STAINLESS STEEL COVER
2A. GRID, STAINLESS STEEL
2A. GRID, STAINLESS STEEL
2B. GRID, PORCELAIN CAST IRON
2B. GRID, PORCELAIN CAST IRON
3. BURNER ASSEMBLY
3. BURNER ASSEMBLY
4. VALVE MANIFOLD ASSEMBLY
4. VALVE MANIFOLD ASSEMBLY
5. KNOBS, FIRE MAGIC (2)
5. KNOBS, FIRE MAGIC (2)
6. CONTROL PANEL, STAINLESS STEEL
6. CONTROL PANEL, STAINLESS STEEL
7. REGULATOR
7. REGULATOR
8. IGNITOR ASSY
8. IGNITOR ASSY
BURNER ASSEMBLY
A. BURNER CAP B. CERAMIC ELECTRODE C. BURNER D. VENTURI TUBE E. ORIFICE, NAT or ORIFICE, L.P.
A
E
Fig. 3-1
B
C
D
2B
2B
1
1
2A
2A
3
3
4
4
5
5
6
PRODUCT DATA TABLE
Specifi cation Value
Specifi cation Value
Counter Opening Height* 12"
Counter Opening Height* 12"
Counter Opening Width* 11
Counter Opening Width* 11-
Counter Opening Depth* 22
Counter Opening Depth* 22-
Double Side Burner
Double Side Burner
BTU per burner
BTU per burner
Natural Gas Orifi ce
Natural Gas Orifi ce
Propane Gas Orifi ce
Propane Gas Orifi ce
1
1
/2"
/2"
3
1
/4"
/2"
15,000
15,000
#50
#49
#58
#56
7
7
8
8
Venturi tube
Orifi ce
Burner - top view
Fig. 3-2
REV 6 0906230824
Table 1 - Product data table
3
L-C2-11109
PREPARING FOR INSTALLATION
WHERE TO INSTALL YOUR
DOUBLE SIDEBURNER
FOR OUTDOOR USE ONLY.
Your double sideburner is designed to complement your Fire Magic grill. It provides a convenient, effi cient cooking surface for side dishes that require bottom heat only.
TOOLS REQUIRED
The double sideburner has been pre-assembled. You need only a pair of wrenches, pliers, or vice grips for the gas connection.
CODE AND SUPPLY REQUIREMENTS
This burner must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.
This appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing the system at pressures in excess of
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at pressures up to and including (3.5 kpa).
1
/2 psig (3.5 kpa).
1
/2 psig
Do not install this unit under unprotected fl ammable surfaces. Do not install or use this appliance inside a building, garage, or any other covered area. It must not be used in or on recreational vehicles or boats.
This is a built-in type unit designed to fi t into open­front enclosures. The control panel of the unit is removable for gas hookup, servicing, and burner adjustment. The control panel must be removable after you install the unit.
INSTALLER NOTE: This unit should be installed so that it can be removed at a later date if factory service is required. Any protrusion into the double sideburner enclosure may prevent the unit from sliding into place (see GAS SUPPLY PLUMBING REQUIREMENTS, on page 5).
ENSURING PROPER COMBUSTION AIR AND COOLING AIR FLOW
You must maintain proper air fl ow for your Fire Magic double sideburner to perform as it was designed (Fig. 4-1). If airfl ow is blocked, overheating and poor combustion will result. Make sure not to block the 1" front air inlet along the bottom of the control panel or more than 75% of the support grid surface with pans or griddles.
ELECTRICAL OUTLETS
Electrical outlets in the vicinity of this appliance
must be properly grounded and GFI equipped.
Important: This unit may be installed into combustible
framing (wood, for instance) provided there is a minimum of a between the sides of the unit and any combustible material. This hanger requires 1 side and back to support the unit.
Fig. 4-1 Top View
Min. 1/2"
Max. 3/4" air gap to all combustible
material
1
/2" of countertop on each
2 1/4"
Hanger
1
/2" airspace
Stainless
steel
hanger
1
2
/4"
Sideburner
Countertop
Edge of counter
cut-out
Fig. 4-2 Front View
Counter Counter
Sideburner
Maintain air gap all the
way down (back and
side) under countertop
Hanger
REV 6 0906230824
4
L-C2-11109
23 3/4"
12"
12 3/8"
2"
2"
1"
X
HEIGHT
4"
WIDTH
PREPARING FOR INSTALLATION (Cont.)
GAS SUPPLY PLUMBING REQUIREMENTS:
The gas supply pipe connection is to be made through the fl oor at the rear of the enclosure. Install the gas line stub at least 2" away from the side walls and 1" from the back wall, but within 5" of the back wall, as illustrated by the shaded area X in Fig. 5-1.
CAUTION: An external valve (with a removable
key) in the gas line is advised for safety and convenience, particularly if the unit is accessible to children.
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" water column (w.c.), minimum 3-1/2", maximum 10-1/2". For propane
gas - normal 11" w.c., minimum 8", maximum 13".
INSTALLATION
1. CHECKING FUEL AND PROPER ORIFICES
Your double sideburner has been pre-assembled
Fire Magic units are equipped with orifi ces for
at the factory.
natural gas, unless otherwise indicated. For use with propane gas, smaller orifi ces must be
1. CHECKING FUEL AND PROPER
installed to avoid hazardous overheating. Please
ORIFICES: Fire Magic units are equipped
refer to Table 1 for the correct orifi ce size. Check
with orifi ces for natural gas, unless otherwise
the orifi ce size by following the instructions
indicated. For use with propane gas, smaller
below. The drill size is stamped on the orifi ce.
orifi ces must be installed to avoid hazardous
If the number is not visible you may have to
overheating. (Please refer to Table 1 for the
remove the orifi ce (as detailed below) to read
correct orifi ce size.)
the number stamped on the side of the orifi ce.
To change or inspect an orifi ce, you need a 5/16"
IF YOU ARE NOT SURE YOU HAVE THE
socket with a spacer (a small piece of tape balled
CORRECT SIDEBURNER ORIFICE SIZE (OR
up, with the sticky side out, works well to hold
WISH TO CHANGE THE ORIFICE), FOLLOW THE
the orifi ce) to prevent the orifi ce from sliding too
STEPS BELOW.
far into, or dropping out of, the socket. The entire sideburner should be lifted from its enclosure and,
CAUTION: IF THE BURNER HAS BEEN IN USE,
where possible, tilted on its side while the orifi ce is still installed. Complete the following steps:
a. Remove sideburner lid and lift off cooking
a. Remove sideburner lid and lift off cooking
b. Removing the control knob and face screws
b. Remove the control knobs and screws fi rst,
Important: Prior to removing the face, you must
WAIT UNTIL THE BURNER AND ITS COMPONENTS ARE COOL TO THE TOUCH.
grid.
grid.
rst, carefully lift away the face.
then carefully lift away the control panel.
slide the battery out of the battery
Important: Prior to fully removing the
bracket located on the right side of
control panel, you must
the face.
disconnect the battery holder assembly wires that are located behind the control panel.
A REGULATOR MUST BE PROVIDED AT THE BOTTLE OR GAS SOURCE FOR USE WITH PROPANE GAS.
22 1/2"
12"
Height
11 1/2"
Width
Fig. 5-1
c. Reach up under the burner support and
remove the burner retaining clip (see Fig.
c. Remove the burner cap, and where fi tted,
5-1), located at the rear of the burner pipe.
the venturi tube from the center of the burner (see Fig. 3-1 & Fig. 3-2).
d. Remove the burner cap and carefully lift
the burner up and out, clearing the ceramic
d. If connected, disconnect the fl ex connector
electrode (see Fig. 5-2), and pulling the
from the double sideburner manifold. This
burner tube away from the orifi ce, located
will enable you to lift out the unit from its
on the end of the orifi ce holder on the left
enclosure, giving ease of access.
side of the unit (see Fig. 5-3).
e. Insert the socket into the center of the
Note: You do not have to lift the burner
Check the number on the side or face of the new orifi ce to be certain you are correctly converting for your gas type (see step 1, above, for orifi ce sizes).
burner, unscrew and extract the orifi ce, taking care not to drop it from inside the
completely out of the unit to access the
socket.
orifi ce.
e. Using a
3
/8" socket, remove orifi ce from the orifi ce holder (see Fig. 5-3) and check the number stamped on the orifi ce face.
f. Replace with the new (correct) orifi ce for
your gas type.
g. Replace the unit into the enclosure or shelf
and follow steps a-c in reverse.
h. Re secure the battery into the battery
bracket. Replace the face and control knob.
Fig. 5-1
Fig. 5-2
Important: If converting the gas type, see the
Orifi ce located at
end of orifi ce holder
CHECKING AND CONVERTING THE REGULATOR section.
Orifi ce holder
Fig. 5-3
REV 6 0906230824
5
L-C2-11109
Loading...
+ 9 hidden pages