Fire Magic A430I6LAP Installation manual

BUILT-IN OUTDOOR GAS GRILLS
US
®
C
A430i, A530i, A540i, A660i, & A790i
INSTALLATION
INSTRUCTIONS AND
OWNER’S MANUAL
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR USE.
WARNINGS AND SAFETY CODES
A790i w/ analog thermometer shown
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
CODE AND SUPPLY REQUIREMENTS: This grill must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with the latest National Fuel Gas Code
(ANSI Z223.1/NFPA 54), or Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
This appliance and its dedicated manual shutoff valve must be disconnected from the gas-supply piping system when testing the system at pressures in excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gas­supply piping system by closing its dedicated manual shutoff valve during any pressure testing of the gas-supply system at pressures up to and including ½ psig (3.5 kPa).
WARNING:
1. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING:
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. For proper installation, refer to the installation instructions. For assistance or additional information, consult a qualifi ed professional service technician, service agency, or the gas supplier.
All electrical outlets in the vicinity of the grill must be properly grounded in accordance with local codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever
is applicable. Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
Proper operation of your grill requires prompt and periodic maintenance. See the CARE &
11-093
Certifi ed to: ANSI Z21.58-2015 CSA 1.6-2015
CLEANING section for details.
REV 1 - 1603010800
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
1
L-C2-434
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
GRIL EXTÉRIEUR DE GAZ DU BUILT-IN
IMPORTANT: LISEZ CES INSTRUCTIONS SOIGNEUSEMENT AVANT DE COMMENCER L’INSTALLATION OU L’UTILISATION
SÛRETÉ ET CODES D’AVERTISSEMENT
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez le gaz à l’appareil.
2. Éteignez-vous n’importe quelle fl amme nue.
3. Ouvrez le couvercle.
4. Si l’odeur continue, gardez loin de l’appareil et appelez immédiatement votre département de fournisseur ou de feu de gaz.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre le plus défunt Code national de gaz de carburant (norme ANSI Z223.1/NFPA 54), et Stockage de gaz naturel et de propane et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être démontés du gaz-fournissent le système siffl ant en examinant le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système siffl ant par fermeture que ses différents robinets d’isolement manuels pendant tous les essais sous pression du gaz­fournissent le système aux pressions jusques et y compris le ½ psig (kPa 3.5).
• Ce gril est pour ultilisation à l’extérieur seulement. Si l’appareil est entreposé à l’intérieur, enlever les bouteilles et les laisser à l’extérieur.
• Ne pas ranger le gril immédiatement aprés l’avoir utilisé. le laisser refroidir avant de le déplacer ou de la ranger. Le non respect de cette mesure de sécurité pourrait entraîner un incendie causant des dommages à la propriété, des blessures ou la mort.
• Ne pas utiliser cet appareil sous une surface combustible.
• Ne pas utiliser cet appareil sous un auvent. Le non respect de cette mesure de sécurité pourrait entraîner un incendie ou des blessures.
• Dégagement minimal entre les parois latérales et l’arriére de l’appareil et la construction combustible (45.7 cm à partir des parois latérales et 45.7cm à partir de l’arriére).
• Le régulareur de pression de gaz prévu avec cet appareil de cuisson à gaz pour l’extérieur doit être utilisé. Ce régulateur est réglé pour une pression de sortie de 5 pouces de colonne de l’eau pour le gaz naturel, et 10 pouces pour le propane.
• LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE CARRÉ). SI VOTRE OFFRE DE GAZ EST 1/2 PLUS GRAND QUE (LIVRES PAR POUCE CARRÉ), UN RÉGULATEUR ADDITIONNEL DOIT ÊTRE INSTALLÉ AVANT LE GRIL. VOIR LA SECTION DE CONDITIONS
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas l’essence ou d’autres vapeurs et liquides infl ammables à proximité de ceci ou d’aucun autre appareil.
2. Un cylindre de propane non relié pour l’usage ne sera pas stocké à proximité de ceci ou d’aucun autre appareil.
AVERTISSEMENT:
L’installation inexacte, l’ajustement, le changement, le service, ou l’entretien peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour de l'aide ou des renseignements supplémentaires, consulter un technicien professionnel qualifié de service, une agence de service ou le fournisseur de gaz.
Toutes les sorties électriques à proximité du gril doivent être correctement fondues selon des codes locaux, ou en l’absence de local code, avec le code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui est applicable.
Maintenez tout électrique-fournissent des cordes et carburant­fournissent des tuyaux partis de n’importe quelle surface de chauffage.
D’OFFRE DE GAZ POUR LA PRESSION APPROPRIÉE D’OFFRE DE GAZ.
• Ne couvrez jamais la surface entière de cuisine ou de gril de gauffreuses ou de casseroles. La surchauffe se produira et les brûleurs ne seront pas très performants quand la chaleur de combustion est emprisonnée au­dessous de la surface à cuire.
• Ne pulvérisez jamais l’eau sur une unité chaude de gaz, comme ceci peut endommager des composants de porcelaine ou de fer de fonte.
• Une fuite de GPL peut causer une incendie ou une explosion si enflammée entraînant des blessures corporelles graves ou la mort.
• Communiquez avec le fournisseur de GPL pour les réparations ou pour disposer de qules bouteille ou du GPL non utilisé.
Certifi é à la norme: ANSI Z21.58-2015 / CSA 1.6-2015
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
REV 1 - 1603010800
2
L-C2-434
CONTENTS
GETTING STARTED
REPLACEMENT PARTS LIST .......................................4
MODEL SPECIFICATIONS ............................................6
BUILT-IN GRILL DIMENSIONS TABLE.........................6
COUNTERTOP OVERHANG .......................................6
SUBSTRATE .............................................................7
BUILT-IN GRILL DIMENSIONS TABLE.........................7
BUILT-IN GRILL WIRING DIAGRAM ...........................8
GRILL MAINTENANCE AND SAFETY INFORMATION
......................................................................................9
ELECTRICAL CONNECTIONS ....................................9
LIGHT SWITCH ........................................................9
INSTALLATION REQUIREMENTS .............................10
OVERHEAD CONSTRUCTION REQUIREMENTS (IF APPLICABLE)
SIDE AND REAR WALL CLEARANCES .......................10
BACKSPLASH CLEARANCE (IF APPLICABLE) ...........10
ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW
EXHAUST REMOVAL ..............................................11
GAS-SUPPLY PLUMBING REQUIREMENTS ...............11
..............................................................11
ENCLOSURE REQUIREMENTS ..................................12
VENTILATION (ALL ENCLOSURES) ..........................12
WHEN A PROPANE (L.P.) CYLINDER IS USED IN THE ENCLOSURE
PROPANE SAFETY INFORMATION ...........................13
WARNING .............................................................13
INSTALLATION SAFETY GUIDELINES.......................13
OPERATING THE UNIT SAFELY AND CORRECTLY .13 SAFE USE & MAINTENANCE OF
PROPANE GAS CYLINDERS ......................................15
...................................................10
.........................................................12
INSTALLATION
INSTALLATION ..........................................................16
COUNTER PREPARATION .......................................16
CONNECT THE GAS SUPPLY ...................................16
INSTALL THE FLAVOR GRIDS ..................................17
ELECTRICAL INSTALLATION ...................................18
ELECTRICAL SAFETY ............................................18
IDENTIFICATION OF GRILL CONTROLS ..................19
USE, CARE, & SERVICE
LIGHTING (IGNITION) INSTRUCTIONS ....................21
ELECTRONIC LIGHTING ........................................21
MANUAL LIGHTING ...............................................21
SHUTTING OFF THE UNIT ......................................21
OPTIONAL DIGITAL THERMOMETER ......................22
OPTIONAL ROTISSERIE ............................................25
OPTIONAL INFRARED BURNER OPERATION ..........26
ACCESSORIES ............................................................27
FIRE MAGIC® DRIP TRAY .........................................28
CARE & CLEANING ...................................................29
REPLACING HALOGEN BULBS ................................30
CONVERT GAS TYPE / CHECK BURNER ORIFICES .31
BURNER AIR SHUTTER ADJUSTMENT ....................33
CONTROL PANEL REMOVAL ....................................35
NOTES PAGE ..............................................................36
TROUBLESHOOTING .................................................37
WARRANTY ...............................................................38
REV 1 - 1603010800
3
L-C2-434
GETTING STARTED
REPLACEMENT PARTS LIST
1
15
2
17
16
13
11
12
6
4
5
9
14
3
10
8
18
7
23
26
To order replacement parts, contact your local Fire Magic dealer.
®
19
21
38
24
22
20
25
42
27
Some items shown are optional, or are not available for certain models. Your model may vary, refer to parts table.
37
REV 1 - 1603010800
4
L-C2-434
REPLACEMENT PARTS LIST (cont.)
A430i A530i A540i A660i A790i
Item Description
1. Stainless cooking grid (set of 2 or 3) 23542-S-2 1 23539-S-2 1 23543-S-3 1 23544-S-3 1 23539-S-3 1
2. Flavor grid (set of 2 or 3) 3063-S-2 1 3056-S-2 1 3064-S-3 1 3057-S-3 1 3056-S-3 1
3. Main burner 3042-50 2 3041-50 2 3042-50 3 3041-50 3 3041-50 3
4. Heatshield kit 24177-05 2 24177-05 2 24177-05 3 24177-05 3 24177-05 3
5. Silicone gasket 24177-06 2 24177-06 2 24177-06 3 24177-06 3 24177-06 3
6. Infrared burner * 3060 1 3050 1 3060 1 3050 1 3050 1
7. Oven lid 23729-53 1 23736-53 1 23733-53 1 23738-52 1 23745-52 1 or Oven lid w/ oven thermometer 23729-55 1 23736-55 1 23733-55 1 23738-55 1 23745-55 1 or Oven lid w/ window † N/A N/A N/A 24170-54 1 24180-54 1
8. Warming rack 3672S-M 1 3672S-M 1 3673S-M 1 3673S-M 1 3675S-M 1
9. Back burner* 24130-11H 1 24130-11H 1 24170-11H 1 24170-11H 1 24180-11H 1
10. Back burner cover* 24148-010 1 24148-010 1 24739-010 1 24739-010 1 24745-010 1
11. Rotisserie motor* 3600-02 1 3600-02 1 3600-02 1 3600-02 1 3600-02 1
12. Heavy-duty motor*† N/A N/A 3600-05 1 3600-05 1 3600-05 1
13. Rotisserie rod* 3603-30 1 3603-30 1 3606-30 1 3606-30 1 N/A
14. Heavy duty rod*† N/A N/A 3606-40 1 3606-40 1 3609-40 1
15. Rotisserie knob* 24187-16 1 24187-16 1 24187-16 1 24187-16 1 24187-16 1
16. Meat holder (pair)* 3613 1 3613 1 3613 1 3613 1 3613 1
17. Counterbalance* 3620E 1 3620E 1 3620E 1 3620E 1 3620E 1
18. Grid lifter 3519 1 3519 1 3519 1 3519 1 3519 1
19. Convertible regulator PR-4 1 PR-4 1 PR-4 1 PR-4 1 PR-4 1
20. Valve manifold w/ back burner 24130-22 1 24130-22 1 24170-22 1 24170-22 1 24180-22 1 or valve manifold w/o back burner 24130-28 1 24130-28 1 24170-28 1 24170-28 1 N/A
21. Control panel w/ back burner, w/ digital thermo. 24130-45 1 24130-45 1 24170-45 1 24170-45 1 24180-45 1 or Control panel w/ back burner, w/o digital thermo. 24130-47 1 24130-47 1 24170-47 1 24170-47 1 24180-47 1 or Control panel w/o back burner, w/ digital thermo. 24130-46 1 24130-46 1 24170-46 1 24170-46 1 N/A or Control panel w/o back burner, w/o digital thermo. 24130-48 1 24130-48 1 24170-48 1 24170-48 1 24180-48 1
22. Small knob* 3016 1 3016 1 3016 1 3016 1 3016 1
23. Large knob 3015 2 3015 2 3015 3 3015 3 3015 3
24. Digital thermometer 24180-12H 1 24180-12H 1 24180-12H 1 24180-12H 1 24180-12H 1 or Oven hood thermometer ‡ 23305 1 23305 1 23305 1 23305 1 23305 1 or Grill top thermometer (window models) ‡ 3573 1 3573 1 3573 1 3573 1 3573 1
25. Meat probe * 24187-14S 1 24187-14S 1 24187-14S 1 24187-14S 1 24187-14S 1
26. Drip tray 3084 1 3084 1 3084 1 3084 1 3084 1
27. Drip tray liner (set of 4) 3557 1 3557 1 3557 1 3557 1 3557 1
28. Wire harness assembly‡ 24177-28 1 24177-28 1 24177-28 1 24177-28 1 24177-28 1
29. Back burner electrode*‡ 4199-52 1 4199-52 1 4199-52 1 4199-52 1 4199-52 1
30. Main burner electrode‡ 3199-72 2 3199-72 2 3199-72 3 3199-72 3 3199-72 3
31. Natural gas orifi ce(s)‡ 3001-42-2 1 3001-40-2 1 3001-44-3 1 3001-42-3 1 3001-38-3 1
32. Natural back burner gas orifi ce(s)‡ 3001-52-1 1 3001-52-1 1 3001-48-1 1 3001-48-1 1 3001-45-1 1
33. Propane gas orifi ce(s)‡ 3001-54-2 1 3001-53-2 1 3001-55-3 1 3001-54-3 1 3001-53-3 1
34. Propane back burner gas orifi ce(s)‡ 3001-59-1 1 3001-59-1 1 3001-56-1 1 3001-56-1 1 3001-55-1 1
35. Fire Magic® cookbook‡ 3595 1 3595 1 3595 1 3595 1 3595 1
36. Thermometer wire harness *‡ 24177-25 1 24177-25 1 24177-25 1 24177-25 1 24177-25 1
37. Power supply w/ connector 24177-12 1 24177-12 1 24177-12 1 24177-12 1 24177-12 1
38. Wire harness extension 24182-53 1 24182-53 1 24182-53 1 24182-53 1 24182-53 1
39. 12V / 10 watt halogen light bulb ‡ 24187-15 2 24187-15 2 24187-15 2 24187-15 2 24187-15 2
40. Light lens ‡ 24187-26 2 24187-26 2 24187-26 2 24187-26 2 24187-26 2
41. Lamp assembly ‡ 24187-28 2 24187-28 2 24187-28 2 24187-28 2 24187-28 2
42. Light switch 24182-46 1 24182-46 1 24182-46 1 24182-46 1 24182-46 1
43. Magic View window (only) *‡ N/A N/A N/A 24187-45 1 24187-45 1
44. Flash tube (left) ‡ 24187-29 1 24187-29 1 24187-29 1 24187-29 1 24187-29 1
45. Flash tube (right) ‡ 24187-35 1 24187-35 1 24187-35 2 24187-35 2 24187-35 2
46. Backburner fl ex connector *‡ 3030-01 1 3030-08 1 3030-01 1 3030-08 1 3030-08 1
* If equipped † Not available on A430i or A530i models ‡ Not shown
REV 1 - 1603010800
Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
5
L-C2-434
MODEL SPECIFICATIONS
MODEL SPECIFICATIONS TABLE
Table 1
Main burner quantity N/P orifi ce drill size
Backburner N/P orifi ce drill size
Infrared searing burner N/P orifi ce drill size
A430i A530i A540i A660i A790i
2
#42 / #542#40 / #533#44 / #553#42 / #543#38 / #53
#52 / #59 #52 / #59 #48 / #56 #48 / #56 #45 / #55
#49 / #56 #45 / #55 #49 / #56 #45 / #55 #45 / #55
Aurora insulating liner model # (not included)* 23130-50 23125-50 23150-50 3176-50 3186-50 Input electrical requirements
120VAC / 15 AMP minimum / 60 Hz / GFCI outlet
Oven lights rating 12V / 10 watt halogen bulb
A Countertop to unit bottom cut-out* 12" 12" 12" 12" 12" B Side to side non-combustible cut-out* 25-
1
/2" 25-1/2" 32" 32" 37-3/4"
C Front to back non-combustible cut-out*† 19-1/2" 23-1/2" 19-1/2" 23-1/2" 23-1/2" D Control panel width non-combustible cut-out 27" 27" 33" 33" 38-
If equipped
*Note: If installing this grill in a combustible enclosure, the correct insulating liner must be used. Consult liner instructions for counter
cut-out dimensions and installation.
Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See SUBSTRATE section on next page.
Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section below).
3
/4"
Countertop
Control panel
C
A
TOP VIEW
B
NON-COMBUSTIBLE
ENCLOSURE CUT-OUT
DIMENSIONS
Lower support
D
FRONT VIEW
See next page
for substrate
considerations
Countertop overhang
Countertop overhang
(Control
panel)
Control
panel
TOP VIEW
(Countertop)
X
Y
1
/4"
Clearance
SIDE VIEW
Countertop
overhang
X= D-B÷2 Y= Total
Countertop Overhang
(Overhang)
Check clearance for
control panel removal
Fig. 6-1
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends beyond the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.
Important: FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and
cross-ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane bottles. See the ENCLOSURE REQUIREMENTS section for details.
REV 1 - 1603010800
6
L-C2-434
MODEL SPECIFICATIONS (cont.)
SUBSTRATE
When adding any substrate to the enclosure front wall (including tiles, stone, etc.), consider the following:
Substrate Behind Control Panel
Substrate + countertop "front to back" cutout must equate to Dim. C (see previous page) when the substrate sits fl ush behind the control panel.
TOP VIEW TOP VIEW
(Countertop)
Substrate
(includes tiles,
etc. at front of
enclosure)
Grill liner
(Control panel)
C
Flush
Countertop
overhang
(if applicable)
1
/4"
Clearance
Fig. 7-1 Fig. 7-2
Substrate Alongside Control Panel
Any additional substrate alongside the control panel does not need to be considered in Dim. C (see previous page), however a overhang) and below is required.
(Control panel)
1
/4" clearance on each side (same as
(Countertop)
Substrate
(includes tiles,
Grill liner
Flush
etc. at front of
C
1
/4"
Clearance
enclosure)
Countertop
overhang
(if applicable)
Model
A430i A530i A540i A660i A790i
BUILT-IN GRILL DIMENSIONS TABLE
Height Width Depth
(Top to bottom) (Left to right) (Front to
Upper hanger to top
(with oven)
Open
(E)
1
20
/4" 13 1/4" 30" 26 1/2" 26 3/4"
Closed
(F)
Hanger to
hanger
(G)
23 5/8" 15" 30" 26 1/2" 29 3/4"
1
20
/4" 13 1/4" 36 1/2" 32 1/2" 26 3/4" 23 5/8" 15" 36 1/2" 32 1/2" 29 3/4" 23 5/8" 15" 42 1/4" 38 1/4" 29 3/4"
G
E
Control
panel
width
(H)
Maximum
I
back)
depth
(I)
F
REV 1 - 1603010800
H
Fig. 7-3
7
L-C2-434
MODEL SPECIFICATIONS (cont.)
Oven
light
BUILT-IN GRILL WIRING DIAGRAM
Main burner igniters
Back burner igniter
(if equipped)
*
Oven
light
Wire harness
assembly
Wire harness
extension
Light
switch
burner 3
Valve manifold
Main
Main
burner 2
Digital thermometer
(if equipped)
A790i model shown. Model wire diagrams may vary.
*
Main
burner 1
Back burner
(if equipped)
Thermocouple
(if equipped)
Meat probe
(if equipped)
Ground
Note: In addition, a wire diagram specifi c to your unit
can be found affi xed to the inside of the control panel.
wire
Power supply
REV 1 - 1603010800
8
L-C2-434
GRILL MAINTENANCE AND SAFETY INFORMATION
1. The outdoor grill and surrounding area MUST
remain clear of fl ammable substances such as gasoline, yard debris, wood, etc.
2. The airfl ow through the vent space located below
the control panel must remain unobstructed.
and clean the orifi ce and burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fi re beneath the grill. A proper fl ame pattern will ensure safe operation and optimal performance. Adjust the air shutter as needed (see AIR SHUTTER ADJUSTMENT).
3. When using propane gas:
5. The in-line gas valve or gas cylinder valve must
a. The required ventilation openings in the
always be shut OFF when the grill is not in use.
enclosure must be clear of debris. See the PROPANE SAFETY INFORMATION section.
6. The drip collector holes must be clear and
unobstructed. Excessive grease deposits can result in a grease fi re.
b. The propane cylinder, regulator, and
rubber hose must be in a location not subject to temperature above 125° F (51° C).
4. The fl ames on each burner burn evenly along
the entire burner with a steady fl ame (mostly blue). If burner fl ames are not normal, check
7. The backburner or IR burner cover must be
removed before using the burner.
8. Whenever reconnecting any wires, apply a
small amount of dielectric grease to the male connector, then make the connection. This will ensure conductivity and prevent moisture from affecting the contact.
WARNING: NEVER cover the entire cooking or grill surface with griddles or pans. Overheating will occur, and
burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The grill serial identifi cation number is located on the underside of the drip tray handle. It
is recommended that the drip tray fi rst be removed and cleaned / emptied of its contents,
then turned over to view. The unit rating label is located on the inside of the control panel.
ELECTRICAL CONNECTIONS A 120VAC (15 AMP minimum) Ground Fault
Circuit Interrupter (GFCI) GROUNDED 3-wire receptacle (not included) is required within the
vicinity of the grill to provide power to the unit.
• Observe all local codes.
• Verify proper polarity of the receptacle.
• If an extension cord is used, ensure it is a 3-wire GROUNDED cord that is rated for the power of the equipment, and is approved for outdoor use with a W-A marking. DO NOT use 2-prong adapters.
• DO NOT TAMPER WITH THE EXTENSION CORD OR THE UNIT POWER-SUPPLY CORD.
Important: ONLY REPLACE THE OVEN LIGHTS
WITH 12V / 10 WATT HALOGEN BULB(S).
LIGHT SWITCH
The light switch is push button operated, and is located on the right side of the control panel (see Fig. 9-1). It controls the power to all lights.
Meat probe
(if equipped)
Light
switch
Fig. 9-1
REV 1 - 1603010800
9
L-C2-434
INSTALLATION REQUIREMENTS
Installation must be performed by a qualifi ed professional service technician.
This grill is designed for outdoor use only. DO NOT use this grill inside a building, garage, enclosed area, or under overhead combustible construction.
See below and the EXHAUST REMOVAL section on the following page for details on installing under non-combustible overhead construction.
DO NOT use this grill in or on a recreational vehicle or boat.
NON-COMBUSTIBLE
CONSTRUCTION ONLY
Min.
5'
Important: If installing this grill in a combustible surround, the correct
RHP insulating liner must be used.
Important: Refer to the information below to ensure all required
clearances are met.
The grill must have a minimum clearance of 18" from combustible materials/items AT ALL TIMES.
OVERHEAD CONSTRUCTION REQUIREMENTS (IF APPLICABLE)
This outdoor cooking gas appliance shall not be used under overhead combustible construction.
A minimum clearance of 5 feet is required between the countertop and the non-combustible construction above (Fig. 10-1).
SIDE AND REAR WALL CLEARANCES
For the minimum clearances between the grill and any side or rear walls, your setup must fall within one (or more) of the following:
A. Clearance between grill and strictly non-combustible wall
(i.e. brick wall, see Fig. 10-2)
• The grill must have a minimum of 4" right, left, and rear clearance from any non-combustible wall. (To allow for proper ventilation and prevent dangerous overheating.)
B. Clearance between grill and a protected combustible wall
(i.e. a non-combustible wall in front of a combustible wall to serve as a barrier. This can be accomplished by brick, or a metal stud fi nished with non-combustible substrate, see Fig. 10-3)
• The grill must have a minimum of 14" right, left, and rear clearance from the protected combustible wall. (The 4" non-combustible material plus an additional 10" clearance between the grill and protected wall.)
C. Clearance between grill and combustible wall
• The grill must have a minimum of 18" right, left, and rear clearance from any combustible wall (see Fig. 10-4).
BACKSPLASH CLEARANCE (IF APPLICABLE)
If a non-combustible backsplash exists, it must have a minimum of a 4" clearance from the rear of the grill (to allow for proper ventilation and prevent dangerous overheating). See Fig. 10-5.
Fig. 10-1 Overhead requirements
Non-combustible
Min.
4"
(Clearance required for
right, left, and rear)
Fig. 10-2 Clearance 'A' Diagram
Non-combustible
substrate
(Clearance required for
right, left, and rear)
Non-combustible 4"
Min.
14"
Com-
bustible
Fig. 10-3 Clearance 'B' Diagram
Combustible
Min.
18"
(Clearance required for
right, left, and rear)
Fig. 10-4 Clearance 'C' Diagram
Non-combustible
Backsplash
Min.
4"
Important: This 4" backsplash clearance must fi rst be met prior to
any non-combustible walls beginning behind it.
REV 1 - 1603010800
10
Fig. 10-5 Backsplash clearance
L-C2-434
INSTALLATION REQUIREMENTS (Cont.)
G
c
The control panel MUST remain removable for servicing (see PARTS LIST).
ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW
Proper airfl ow (Fig. 11-1) MUST be maintained for the grill to perform as it was designed. If airfl ow is blocked, overheating and poor combustion will result. Do not block the 1" (2.5 cm) front air inlet along the bottom of the control panel or more than 75% of the cooking grid surface with pans or griddles.
Note: The 1" (2.5 cm)
front air space also allows access to the drip tray.
EXHAUST REMOVAL
Fig. 11-1 - Ventilation diagram
If the grill is installed under an overhead structure, it must be constructed of non-combustible material. An
exhaust hood is recommended. See below.
GAS-SUPPLY PLUMBING REQUIREMENTS
For natural gas or a household propane system, rigid (1.3 cm) or
3
/4" (1.9 cm) black steel pipe or local code-
1
/2"
approved pipe is required to conduct the gas supply to the unit. Contact your local gas supplier. Connect this pipe to the required C.S.A.-approved stainless-steel fl ex connector (attached). An NPT adapter has been provided
1
for
/2" pipe. DO NOT use a rubber hose within the grill
enclosure. Apply only joint compounds that are resistant to all gasses to all male pipe fi ttings except fl are fi ttings. Make sure to tighten every joint securely.
Note: If
1
/2" (1.3 cm) pipe is used with natural gas,
it should be no longer than 20' (6.1 meters).
Important: A shut-off valve (not included) in
the gas line is required. It provides
for safety when the unit is not in use and for convenient maintenance and repair. It must be installed within 6 feet of the unit. Use a pipe joint compound resistant to all gasses on all male fi ttings except fl are fi ttings.
When using an exhaust hood:
The cooking grid area must be covered by an exhaust hood (with a vent) larger than the cooking surface. Refer to manufacturer specifi cations. An exhaust fan with a rating of 1,000 CFM (cubic feet per minute) (472 liters per second) or more may be necessary to effectively remove smoke and other cooking by-products from the area under the hood. RHP Vent Hoods are available,
contact your local dealer. THIS UNIT MUST NOT BE LOCATED IN A FULLY
ENCLOSED AREA OF ANY KIND.
INCORRECT
Rear oven lid vent
CORRECT
Left-side hanger
Orient grill so prevailing wind blows this way.
Flex connector
Left-side support wall
CAUTION: Wind blowing into or across the rear
oven lid vent (Fig. 11-2) can cause poor performance and/or dangerous overheating. Orient the grill so that the prevailing wind blows toward the front of the grill (Fig. 11-3).
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water column (w.c.), minimum 5" (12.7 cm), maximum 10 cm). For propane gas - normal 11" w.c., minimum 10" (25.4 cm), maximum 13" (33 cm).
Fig. 11-4
1
/2" (26.7
YOU MUST PROTECT
REAR OVEN VENT FROM
PREVAILING WIND
Fig. 11-2
REV 1 - 1603010800
PLACE GRILL SO PREVAILING
WIND BLOWS TOWARD FRONT
OF GRILL
Fig. 11-3
11
L-C2-434
ENCLOSURE REQUIREMENTS
VENTILATION (ALL ENCLOSURES)
For All Piping Systems and All Gas Types: (Natural Gas, Household Propane, L.P. Cylinder)
FOR YOUR SAFETY, you must provide the openings listed below for replacement air and cross-ventilation of the unit enclosure.
Ventilation Requirements:
• Minimum 4 openings (2 per side wall - spaced at 180 degrees)
• Top openings: within 5" of countertop (see below)
• Bottom openings: within 5" of fl oor (see below)
One side of the enclosure shall be left completely open to the outside; OR 4 (minimum) ventilation openings MUST be created (reference Fig. 12-1):
Each opening must have a minimum of 10 sq. in. of free area. The openings must be equally sized and unobstructed.
Two openings must be in the side walls of the enclosure, at the top level, and spaced at 180 degrees. The openings must begin 1" or less below the countertop level and end no more than 5" below the countertop level.
Two openings must be in the side walls of the enclosure, at the fl oor level, and spaced at 180 degrees. The openings must begin 1" or less above the fl oor level and end no more than 5" above the fl oor level.
To achieve the proper ventilation, you may use RHP venting panels (PN 5510-01) as shown. Contact your dealer.
KEEP THE VENT OPENINGS AND SURROUNDING AREA OF THE ENCLOSURE CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
WARNING: Ventilation openings in side walls shall not
communicate directly with other enclosures of the outdoor cooking gas appliance.
WHEN A PROPANE (L.P.) CYLINDER IS USED IN THE ENCLOSURE
When a propane (L.P.) cylinder is installed inside of the enclosure, the guidelines below MUST be followed. FAILURE TO DO SO MAY CAUSE DAMAGE TO YOUR UNIT AND/OR PERSONAL INJURY. Reference Fig. 12-2 for an example.
Keep surrounding area
and vent openings clear
1"
max.
Vent openings (4)
10 sq. in. of free
area min. (ea.)
1"
max.
5"
max.
5"
max.
for proper venting
Fig. 12-1 Ventilation detail
Grill
3" min.
C.S.A. listed stainless steel fl ex connector
Adapter
Non-combustible
heatshield
L.P.
cylinder
Regulator/
assembly
Fig. 12-2 Propane cylinder orientation
hose
• Only a C.S.A. listed stainless steel connector can be connected to the grill.
• The regulator/hose assembly coming from the propane cylinder can only be connected to the above mentioned grill fl ex connector. DO NOT connect the regulator/ hose assembly directly to the grill. An adapter will be required.
• A non-combustible heatshield must be installed to protect the regulator/hose assembly and propane cylinder valve.
• RHP offers propane tank door with tank tray models and a propane tank heatshield that rest directly on the tank to meet the cylinder install requirements. Propane tank door with tank tray shown in Fig. 12-3. Contact your dealer for ordering information.
REV 1 - 1603010800
12
Cylinder & regulator/hose assembly
protected by heatshield
33820-TSL
model shown
Additional adapters may be required
for your setup (not included)
Equipped with adapter
for hose assembly. Flex connector not
included.
Fig. 12-3 Optional RHP door w/ tank tray
L-C2-434
Loading...
+ 26 hidden pages