Fire Magic 36-VH User Manual

WALL VENT HOOD
For Outdoor Use Only
36-VH, 42-VH, 48-VH and 60-VH series
42-VH-6 model shown
AND OWNER’S MANUAL
This vent hood is for outdoor,
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
Important: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR USE.
wall mount installation only.
WARNINGS AND SAFETY CODES
CAUTION:
• This vent hood is for outdoor, wall mount installation only.
• For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors!
• Observe all local codes and ordinances when installing this appliance. If no local codes are applicable, wire unit in accordance with the latest National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever is applicable.
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the grill this vent hood
is installed above.
2. Extinguish any open fl ame.
3. Open the lid of the grill.
4. If odor continues, keep away from the
appliances and immediately call your gas supplier or the fi re department.
WARNING:
To avoid the risk of property damage and/or personal injury, installation work and electrical wiring must be performed by a qualifi ed professional installer. This appliance must be installed in accordance with this instruction.
1. Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of the gas grill this vent hood is installed above, or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of the gas grill this vent hood is installed above, or any other appliance.
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. For proper installation, refer to the installation instructions. For as­sistance or additional information, consult a qualifi ed professional installer or service agency.
All electrical outlets in the vicinity of the grill and vent hood must be properly grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever is applicable.
Keep all electrical-supply cords and fuel-supply hoses away from any heated surface.
10-33
WARNING:
WARNING:
Certifi ed to: ANSI Z21.58b-2012 CSA 1.6b-2012
REV 2 - 1502191555
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
1
L-C2-387
INSTRUCTIONS D'INSTALLATION ET
MANUEL DU PROPRIÉTAIRE
CAPOT DE PASSAGE DE MUR
Pour l'usage extérieur seulement
36-VH, 42-VH, 48-VH, and 60-VH série
IMPORTANT: LISEZ CES INSTRUCTIONS SOI-
GNEUSEMENT AVANT DE COMMENCER
L'INSTALLATION OU L'UTILISATION
AVERTISSEMENTS ET CODES DE SÛRETÉ
ATTENTION:
• Ce capot de passage est pour extérieur, installation de bâti de mur seulement.
• Pour l'usage de aération général seulement. N'employez pas pour épuiser les matériaux dangereux ou explosifs et les vapeurs!
• Observez tous les codes locaux et ordonnances en installant cet appareil. Si aucun code local ne s'applique, unité de fi l selon le plus défunt code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui s'applique.
DANGER:
SI VOUS SENTEZ LE GAZ:
1. Coupez le gaz au gril que ce capot de passage
est installé ci-dessus.
2. Éteignez-vous n'importe quelle fl amme nue.
3. Ouvrez le couvercle du gril.
INSTALLATEUR: Laissez ces instructions avec
le consommateur.
CONSOMMATEUR: Maintenez pour la future
référence.
Ce capot de passage est pour extérieur,
installation de bâti de mur seulement.
AVERTISSEMENT:
1. Ne stockez pas ou employer l'essence ou
d'autres vapeurs et liquides infl ammables à proximité du gaz grillez ce capot de passage est installé ci-dessus, ou n'importe quel autre appareil.
2. Un cylindre de LP non relié pour l'usage ne
sera stocké à proximité du gril de gaz que ce capot de passage est installé ci-dessus, ou d'aucun autre appareil.
AVERTISSEMENT:
L'installation, l'ajustement, le changement, le service, ou l'entretien inexact peuvent causer des dommages ou des dégats matériels. Pour l'installation appropriée, référez-vous aux in­structions d'installation. Pour l'aide ou les infor­mations supplémentaires, consultez un instal­lateur ou une agence de service professionnel qualifi é.
4. Si l'odeur continue, gardez à partir des appareils
et appelez immédiatement votre fournisseur de gaz ou les corps de sapeurs-pompierssupplier or the fi re department.
AVERTISSEMENT:
Pour éviter le risque de dégats matériels et/ou de dommage corporel, le travail d'installation et le câblage électrique doivent être exécutés par un installateur professionnel qualifi é. Cet appareil doit être installé selon cette instruction.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 2 - 1502191555
Toutes les sorties électriques à proximité du capot de gril et de passage doivent être correctement fondues selon des codes locaux, ou, en l'absence des codes locaux, avec le code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui s'applique.
Maintenez tout électrique-fournissent des cordes et carburant-fournissent des tuyaux à partir de n'importe quelle surface heated.
Certifi ed to: ANSI Z21.58b-2012 CSA 1.6b-2012
10-33
2
L-C2-387
CONTENTS
GETTING STARTED
IMPORTANT PRE-INSTALLATION AND SAFETY INFORMATION ............................................5
SPECIFICATIONS AND DIMENSIONS
ELECTRICAL SAFETY .............................................................................................................................6
TOOLS REQUIRED ....................................................................................................................................7
REPLACEMENT PARTS LIST .................................................................................................................8
INSTALLATION REQUIREMENTS - FIRE MAGIC SPACER & DUCT COVER ........................9
INSTALLATION REQUIREMENTS - CUSTOM SPACER & SOFFIT ..........................................10
INSTALLATION
INSTALLATION ........................................................................................................................................ 11
SPACER ................................................................................................................................................. 11
TRANSITION .........................................................................................................................................12
WALL MOUNT BRACKET ....................................................................................................................13
VENT HOOD .........................................................................................................................................14
VENT PIPING .......................................................................................................................................15
FAN ASSEMBLY ....................................................................................................................................16
WIRING CONNECTIONS .....................................................................................................................16
BAFFLE ................................................................................................................................................17
GREASE FILTERS ................................................................................................................................17
ELECTRICAL ........................................................................................................................................18
DUCT COVER / CUSTOM SOFFIT .....................................................................................................19
................................................................................................6
USE, CARE, & SERVICE
OPERATION ...............................................................................................................................................21
VENT HOOD FANS...............................................................................................................................21
GRILL TOP LIGHTING ........................................................................................................................21
SER VICING AND CLEANING ..............................................................................................................22
REMOVE FIRE MAGIC DUCT COVER (if applicable) ......................................................................22
STAINLESS STEEL CARE.....................................................................................................................22
GREASE FILTERS ................................................................................................................................22
FANS ......................................................................................................................................................22
REPLACING HALOGEN BULBS .........................................................................................................23
NOTES PAGE .............................................................................................................................................24
TROUBLESHOOTING .............................................................................................................................25
WARRANTY ..............................................................................................................................................26
REV 2 - 1502191555
3
L-C2-387
L'INFORMATION IMPORTANTE DE PRÉINSTALLATION ET DE SÛRETÉ
AVERTISSEMENT!
1. Lisez toutes les instructions.
2. CE CAPOT DE PASSAGE EST POUR EXTÉRIEUR, INSTALLATION DE BÂTI DE MUR SEULEMENT. Extérieur est défi ni comme secteur qui a l'air illimité, s'ouvrent aux éléments à tout moment. Un mur est défi ni comme côté d'un plancher et d'un toit se reliants de bâtiment.
3. L'installation, le service, et la réparation doivent être faits par un technicien qualifi é de service professionnel.
4. Cette hotte est à utiliser avec un gril à gaz seulement. Il n'est pas recommandé pour une utilisation avec un
gril à charbon (en raison de la production de chaleur plus élevé qui peut causer des dommages à la hotte).
5. Le capot de passage et le gril de gaz ne sont pas prévus pour être installés dans ou sur des bateaux ou des camping-cars.
6. Pour se protéger contre la décharge électrique, n'immergez pas la corde ou ne branchez pas l'eau ou tout autre liquide.
7. Débranchez de la sortie si non utilisable et avant le nettoyage. Laissez se refroidir avant de mettre dessus ou enlever des pièces.
8. N'actionnez aucun appareil avec une corde endommagée, prise, ou après les défauts de fonctionnement d'appareils ou avez été endommagé de toute façon. Entrez en contact avec le fabricant pour la réparation.
9. Ne laissez pas la corde toucher les surfaces chaudes.
10. N'employez pas un appareil à gaz à cuire extérieur pour des buts autres que prévu.
11. En se reliant, reliez d'abord la prise à l'appareil à gaz à cuire extérieur branchent alors l'appareil à la sortie.
12. Cet appareil doit être fondu. En cas d'un court-circuit électrique, fondre réduit le risque de décharge
électrique en fournissant un fi l d'évasion pour le courant électrique. Cet appareil equipeed avec une corde ayant un fi l fondé avec une prise fondante. La prise doit être branchée à une sortie qui est correctement installée et fondue.
13. Utilisez uniquement un correctement câblé et inspecté 120VAC (15 AMP minimum) disjoncteur (GFCI) TERRE 3 fi ls récipient avec cet appareil au gaz de cuisine en plein air.
14. N'enlevez jamais la prise fondante ou l'employez avec un adapteur de 2 fourches.
15. Ne pas utiliser une rallonge. Si le cordon d'alimentation est trop court, demandez à un électricien qualifi é
d'installer une prise près de l'appareil.
16. Quand la coupure ou le forage dans un mur ou un plafond, n'endommagent pas le câblage électrique et d'autres utilités cachées.
17. Des ventilateurs canalisés doivent toujours être exhalés à l'extérieur.
18. AVERTISSEMENT : Pour réduire le risque du feu, employez seulement la canalisation en métal.
19. AVERTISSEMENT : Pour réduire le risque d'un dessus de gamme graissez le feu: a. Ne laissez jamais les unités extérieures sans surveillance aux arrangements élevés. Tabagisme de cause
de Boilovers et débordements graisseux qui peuvent mettre à feu. Chauffez les huiles lentement sur de bas ou moyens arrangements.
b. Toujours mettre la hotte au réglage HI lors de la cuisson à feu vif ou que vous cuisinez des mets fl ambés. c. Nettoyez les ventilateurs d'aération fréquemment. On ne devrait pas permettre à la graisse de s'accumuler
sur le ventilateur ou le fi ltre.
d. Employez la taille appropriée de casserole. Employez toujours le cookware approprié pour la taille de
la surface à cuire.
20. N'EMPLOYEZ PAS LES COUDES 90˚ POUR CETTE INSTALLATION. N'UTILISEZ PAS UNE PAC RESTRICTIVE D'ARRÊT POUR CETTE INSTALLATION. La tuyauterie de passage devrait être installée aussi directement comme possible d'empêcher la contre-pression sur les ventilateurs. Mettez en référence la section SIFFLANTE de PASSAGE de ce manuel pour des détails.
SAUF CES INSTRUCTIONS
REV 2 - 1502191555
4
L-C2-387
IMPORTANT PRE-INSTALLATION AND SAFETY INFORMATION
WARNING!
1. Read all instructions.
2. THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY. Outdoor is defi ned
as an area that has unconfi ned air, open to the elements at all times. A wall is defi ned as a side of a building connecting fl oor and roof.
3. Installation, service, and repair must be done by a qualifi ed professional service technician.
4. This vent hood is for use with a gas grill only. It is not recommended for use with a charcoal grill
(due to higher heat output that may cause damage to the vent hood).
5. The vent hood and the gas grill are not intended to be installed in or on boats or recreational vehicles.
6. To protect against electric shock, do not immerse cord or plugs in water or other liquid.
7. Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or
taking off parts.
8. Do not operate any appliance with a damaged cord, plug, or after the appliance malfunctions or
has been damaged in any manner. Contact the manufacturer for repair.
9. Do not let the cord touch hot surfaces.
10. Do not use an outdoor cooking gas appliance for purposes other than intended.
11. When connecting, fi rst connect plug to the outdoor cooking gas appliance, then plug appliance
into the outlet.
12. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the
risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounded wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
13. Use only a properly wired and inspected 120VAC (15 AMP minimum) Ground Fault Circuit Interrupter
(GFCI) GROUNDED 3-wire receptacle with this outdoor cooking gas appliance.
14. Never remove the grounding plug or use with an adapter of 2 prongs.
15. Do not use an extension cord. If the power cord is too short, have a qualifi ed electrician install an
outlet near the appliance.
16. When cutting or drilling into a wall or roof, do not damage electrical wiring and other hidden utilities.
17. Ducted fans must always be vented to the outdoors.
18. WARNING: To reduce the risk of fi re, use only metal ductwork.
19. WARNING: To reduce the risk of a range top grease fi re:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b. Always turn hood to HI Setting when cooking at high heat or when cooking fl aming foods. c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. d. Use proper pan size. Always use cookware appropriate for the size of the cooking surface.
20. DO NOT USE 90˚ ELBOWS FOR THIS INSTALLATION. DO NOT USE A RESTRICTIVE
TERMINATION CAP FOR THIS INSTALLATION. Vent piping should be installed as straight as possible to prevent back-pressure on the fans. Reference the VENT PIPING section of this manual for details.
SAVE THESE INSTRUCTIONS
REV 2 - 1502191555
5
L-C2-387
ELECTRICAL SAFETY
To protect against electric shock, do not immerse cord or plugs in water or other liquid. Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts. Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance malfunctions
or has been damaged in any manner. Contact the manufacturer for repair. Do not let the cord touch hot surfaces. Do not use an outdoor cooking gas appliance for purposes other than intended. When connecting, fi rst make wire connections then plug appliance into the outlet.
Use only a properly wired and inspected 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire receptacle with this outdoor appliance.
Never remove the grounding plug or use with an adapter of 2 prongs. Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and approved for
outdoor use with a W-A marking.
SPECIFICATIONS AND DIMENSIONS
36-VH series 42-VH series 48-VH series 60-VH series
Specifi cation Value Value Value Value
Unit height * 18" 18" 18" 18"
Unit width 36" 42" 48" 60"
Unit depth 30" 30" 30" 30"
* Height is of vent hood only (not accounting for transition).
36-VH series 42-VH series 48-VH series 60-VH series
Specifi cation Value Value Value Value
Transition height 10" 10" 10" 10"
Specifi cation Value
Input electrical requirements
120VAC / 15 AMP minimum / 60 Hz / GFCI outlet
Fans 120 volts, 1200 CFM High Pressure Output
Power consumption 1,010 watts
Vent Hood Model Designed For Use With Grills:
REV 2 - 1502191555
36-VH series up to A540 42-VH series up to (A,E)660
48-VH series up to (A,E)790 60-VH series up to E1060
Table 1 - Specifi cations Table
6
L-C2-387
SPECIFICATIONS AND DIMENSIONS (cont.)
WIRING DIAGRAM
Wire harness, blower vent hood
Power cord
Wire harness, main vent hood
Thermostat Snap Disc Assy
Light Assy 120V 50 Watt
Blower Motor 600 CFM
Fan switch
3-position rotary switch
Light switch
TOOLS REQUIRED
The following are the minimum tools required for the installation of your vent hood components. Additional tools may be required for your individual installation.
• Proper personal safety equipment
• Appropriate tools for electrical install
• Power drill
• Drill bit - Phillips head
• Medium Philips screwdriver
3
/8" nut driver
1
/4" nut driver or 1/4" hex driver (drill bit)
• Measuring tape
• Level
• Duct tape
• Silicone sealant
REV 2 - 1502191555
7
L-C2-387
REPLACEMENT PARTS LIST
36-VH-6 42-VH-6 48-VH-6 60-VH-6
Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
Transition VH-11 1 VH-11 1 VH-11 1 VH-11 1
1.
Wall mount bracket VH-17-6 1 VH-19-6 1 VH-22-6 1 VH-21-6 1
2.
Complete vent hood assembly VH-36-01-6 1 VH-42-01-6 1 VH-48-01-6 1 VH-60-01-6 1
3.
Light assembly* VH-12-6 2 VH-12-6 2 VH-12-6 2 VH-12-6 2
4.
120V / 50 watt halogen light bulb* VH-23 2 VH-23 2 VH-23 2 VH-23 2
5.
Light lens* VH-24 2 VH-24 2 VH-24 2 VH-24 2
6.
Control switch* VH-25 2 VH-25 2 VH-25 2 VH-25 2
7.
Control knob VH-26 2 VH-26 2 VH-26 2 VH-26 2
8.
Complete fan assembly VHF-1200-6 1 VHF-1200-6 1 VHF-1200-6 1 VHF-1200-6 1
9.
10.
11.
12.
13.
14.
* Not shown
Baffl e VH-36-04 1 VH-42-04 1 VH-48-04 1 VH-60-04 1 Grease fi lter Filter spacer
Vent hood wire harness*
Thermal switch* VH-28 1 VH-28 1 VH-28 1 VH-28 1
(set of 4 or 6) (42" models only)
VH-16-4 1 VH-18-4 1 VH-15-4 1 VH-18-6 1
n/a n/a VH-42-03-06 2 n/a n/a n/a n/a
VH-27 1 VH-27 1 VH-27 1 VH-27 1
Replacement parts can be
ordered from your local Fire
Magic® dealer.
42-VH-6 model shown
IMPORTANT
1
2
3
8
9
Remove all packing
material (including any
protective coatings) and
discard prior to use.
REV 2 - 1502191555
10
11
12
Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746
8
L-C2-387
INSTALLATION REQUIREMENTS - FIRE MAGIC SPACER & DUCT COVER
Fire Magic offers a spacer and duct cover specifi cally designed for your vent hood. Reference the information below for an overall orientation. (Contact your dealer for ordering information.)
In order to use these prefabricated components, ensure the component dimensions allow for an appropriate
install as addressed below (as individual setups may vary).
Alternatively, a custom spacer and soffi t can be constructed that is appropriate for your individual setup. See the following page for details.
• THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.
• Installation must be done by a qualifi ed professional service technician.
• Below is a diagram of a generic installation.
• Please review and understand this section prior to proceeding with installation.
VENT PIPING
Install 10" round galvanized (single wall) vent piping as required. Installation will depend on roof construction.
ROOF (8ft)
R E A R
W
A L L
(N
O N C O M B U
S T
B
L
E)
DUCT COVER
(To enclose transition and area above hood. Some installs may not require a duct cover, as countertop height & roof height may vary. )
HOOD
30-33"
12"
20
DUCT COVER
1
/4"
SPACER
Width varies
by model:
(36", 42", 48", 60")
S P A C E R
Transition
(bracket)
GAS
GRILL
(rear of vent hood
must align with
I
rear of grill oven)
The Spacer depth is based upon 8" between a non-combustible wall and the rear of the grill (i.e. 4" backsplash + 4" required clearance).
The Duct Cover height is based upon a 33" - 36" countertop height and an 8' high ceiling.
Note: Drawings are not to scale.
18"
8"
Width varies
by model:
(36", 42", 48", 60")
REFER TO INSTALLATION SECTION FOR COMPLETE DETAILS REGARDING ALL INFORMATION FOUND ON THIS PAGE.
REV 2 - 1502191555
9
L-C2-387
INSTALLATION REQUIREMENTS - CUSTOM SPACER & SOFFIT
When constructing a custom spacer and soffi t, reference the information below for an overall orientation.
• THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.
• Installation must be done by a qualifi ed professional service technician.
• Below is a diagram of a generic installation.
• Please review and understand this section prior to proceeding with installation.
VENT PIPING
Install 10" round galvanized (single wall) vent piping as required. Installation will depend on roof construction.
ROOF
SOFFIT *
(To enclose transition and area above hood. Some installs may not require a soffi t, as countertop height & roof height may vary. )
Custom Soffi t Detail *
Model X Y Z
HOOD
30-33"
36-VH
42-VH
48-VH
60-VH
distance from
top of vent
hood to roof
distance from
top of vent
hood to roof
distance from
top of vent
hood to roof
distance from
top of vent
hood to roof
B dimension
of spacer
+ 12"
B dimension
of spacer
+ 12"
B dimension
of spacer
+ 12"
B dimension
of spacer
+ 12"
36"
42"
48"
60"
Soffi t *
X
Y
Spacer *
Z
R
E
A
R
Transition
S
7.125" (to bracket center line)
P A C E
(bracket)
R
*
W
GAS
GRILL
A
(rear of vent hood
L
must align with
rear of grill oven)
L
* Spacer/soffi t may be constructed of wood, metal framing, etc. Upon install completion; the exposed sides of the spacer/
soffi t may be fi nished with drywall or other appropriate materials. Dimensions provided here include any fi nishing substrate.
The front of the spacer (that is exposed to the rear of the vent hood); must include a solid wall to allow for the vent hood
to be properly secured into it. The soffi t must allow permanent interior access (i.e. access panel/door).
REFER TO INSTALLATION SECTION FOR COMPLETE DETAILS REGARDING ALL INFORMATION FOUND ON THIS PAGE.
Custom Spacer Detail *
Model A B C
distance from
36-VH 18"
42-VH 18"
48-VH 18"
60-VH 18"
Note: Drawings are not to scale.
rear wall to rear
of grill oven
distance from
rear wall to rear
of grill oven
distance from
rear wall to rear
of grill oven
distance from
rear wall to rear
of grill oven
A
36"
C
B
42"
48"
60"
REV 2 - 1502191555
10
L-C2-387
INSTALLATION
THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.
To ensure safety and proper performance; the vent hood installation must be done by a qualifi ed professional service technician. Reference the INSTALLATION REQUIREMENTS section during the course of the install for dimensions and overall orientation.
If possible, the gas grill should be removed for ease of installation and to prevent damage to the grill.
Important: Prior to starting installation, the baffle
(inside of vent hood) and the wall mount bracket (rear of vent hood) must be removed. Be sure to retain all hardware removed. See Fig. 11-1 and 11-2.
Baffl e
Fig. 11-1 Remove baffl e
Wall mount
SPACER
Fire Magic offers a spacer specifi cally designed for your vent hood. Contact your dealer for ordering information. Alternatively, a custom spacer can be constructed for your setup. Follow the appropriate section for your spacer type.
Fire Magic Spacer:
The Fire Magic spacer comes ready to be mounted. It should be installed 30-33" above the grill, centered, and level. See Fig. 11-3.
Important: Be sure to allow for the proper clearance above
the spacer for the soffi t / duct cover that is to be installed at a later time.
1. Locate and mark the REAR WALL studs.
2. Determine the install location of the spacer (30-33" above
the grill). Locate the "left-to-right" center, and pencil a vertical line on the rear wall. Then pencil a horizontal line
7.5" up from the bottom of the spacer (see Fig. 11-4, A-C).
3. Place the spacer over the two lines. Use the alignment
notches found on spacer's center-rear bracket to aid in proper location and leveling (see Fig. 11-4, D).
Remove two rows of screws
Fig. 11-2 Remove wall mount bracket
ROOF
• Allow for proper soffi t / duct cover clearance above
R
• Spacer must be properly secured into REAR WALL studs.
• Spacer has slots & alignment tabs to aid in leveling / installing
E A R
S P A C E R
W
A
30 - 33"
L
(remove grill
if possible)
L
Fig. 11-3 Fire Magic spacer orientation
4. Using appropriate mounting hardware for the rear wall
construction; secure the spacer (via the center-rear bracket) into the rear wall (see Fig. 11-4, E).
5. Next use additional mounting hardware, and the support
plates (supplied with spacer), to secure the top-rear of the spacer into the rear wall (see Fig. 11-4, F).
Important: THE SPACER MUST BE SECURED INTO
MULTIPLE WALL STUDS, USING THE APPROPRIATE HARDWARE, TO ENSURE PROPER SUPPORT. METAL FRAMEWORK WILL REQUIRE ADDITIONAL WALL STUDS AND SCREWS FOR PROPER SUPPORT. CONSULT A PROFESSIONAL CONTRACTOR FOR YOUR INDIVIDUAL SETUP.
REV 2 - 1502191555
11
B
mark
center
C
7.5"
A
30 - 33"
F
E
D
align
Fig. 11-4 Install Fire Magic spacer (36" shown)
L-C2-387
INSTALLATION (cont.)
Custom Spacer:
Construct the spacer frame according to your individual install preference, while following the guidelines found in the INSTALLATION REQUIREMENTS section. The front of the spacer (that is exposed to the rear of the vent hood); must include a solid wall to allow for the vent hood to be properly secured into it.
When designing the spacer; account for the thickness of your fi nishing substrate so that overall dimensions are fl ush with the vent hood.
The spacer should be installed 30-33" above the grill, centered, and level. See Fig. 12-1.
Important: Be sure to allow for the proper clearance
above the spacer for the soffi t / duct cover that is to be installed at a later time.
1. Locate and mark the REAR WALL studs.
2. Determine the install location of the spacer (30-33"
above the grill).
3. Using appropriate mounting hardware for the spacer
and rear wall construction; secure it into the rear wall.
ROOF
• Allow for proper soffi t / duct cover clearance above
R
• Spacer must be properly secured into REAR WALL studs.
• Spacer must have a solid front wall
E A R
S P A C E R
W
A
30 - 33"
L
(remove grill
if possible)
L
Fig. 12-1 Custom spacer orientation
Important: THE SPACER MUST BE SECURED INTO
MULTIPLE WALL STUDS, USING THE APPROPRIATE HARDWARE, TO ENSURE PROPER SUPPORT. METAL FRAMEWORK WILL REQUIRE ADDITIONAL WALL STUDS AND SCREWS FOR PROPER SUPPORT. CONSULT A PROFESSIONAL CONTRACTOR FOR YOUR INDIVIDUAL
SETUP.
4. Install fi nishing substrate to left and right sides, and
bottom of spacer as appropriate.
TRANSITION
1. Rest the vent hood on its rear panel.
2. Apply a bead of silicone along the bottom of the
mounting fl ange of the transition before installation (see Fig. 12-2, A).
3. Position the transition in place and secure using a power
drill with a (4) supplied #6 x 3/8" hex head screws. Reach into and fasten the screws from inside the vent hood. (An additional person should hold the transition in place while it is being fastened.) See Fig. 12-2, B-C.
1
/4" hex driver (or a 1/4" nut driver) and the
Apply silicone between
transition and hood
B
Hold transition
in place from
outside
Fig. 12-2 Install transition
A
C
Drill 4
screws
from inside
REV 2 - 1502191555
12
L-C2-387
INSTALLATION (cont.)
WALL MOUNT BRACKET
The wall mount bracket must be installed into the spacer to assist in supporting the vent hood.
To install wall mount bracket to Fire Magic Spacer:
Fire Magic spacers are designed with pre-drilled holes and include screws for ease of bracket installation.
1. Center the bracket (from left-to-right) over the channel
located on the front center of the Fire Magic Spacer.
2. Using a medium Phillips screwdriver and the large 1/4-
20 screws supplied with the spacer, secure the bracket in place. The spacer has pre-drilled holes. See Fig. 13-1.
To install wall mount bracket to custom spacer:
The bracket should be centered from left to right on the spacer. The horizontal position of the bracket center must be
7.125" down from the top of the vent hood/spacer. Alignment notches are provided on the top, bottom, center, and sides of the bracket to aid in proper location and leveling.
1. Locate the "left-to-right" center of the spacer and pencil
a vertical line. Then pencil a horizontal line 7.125" down from the top of the spacer (see Fig. 13-2, A-B).
Fire Magic
Spacer
Fig. 13-1 Install wall bracket to F.M. Spacer
C
align
Custom
Spacer
mark
center
A
2. Place the bracket over the two lines. Use the alignment
notches in the top, bottom, center, and sides of the bracket to properly locate and assist in leveling (see Fig. 13-2, C).
3. Using appropriate mounting hardware for the spacer
construction; secure the bracket onto the spacer (see Fig. 13-2, D).
Important: THE BRACKET MUST BE SECURED INTO
THE SPACER STUDS TO ENSURE PROPER SUPPORT. A MINIMUM OF 4 SCREWS WITH FENDER WASHERS MUST BE EVENLY DISTRIBUTED AND FASTENED INTO TWO STUDS. ADDITIONAL SCREWS WILL BE REQUIRED ACROSS THE BRACKET INTO THE SPACER WALL, FOR COMPLETE SUPPORT.
To ensure a proper ly installed bracket, fi rst hand­tighten all screws. Reposition the bracket as needed, then fully tighten.
7.125"
D
B
Fig. 13-2 Install wall bracket to custom spacer
REV 2 - 1502191555
13
L-C2-387
INSTALLATION (cont.)
VENT HOOD
1. Rest the vent hood onto the wall mount bracket, being
sure that the tabs on the bracket engage the slots on the rear of the hood for proper support. See Fig. 14-1.
2. Ensure the sides, top, and bottom of the vent hood sit
fl ush with the spacer (see Fig. 14-2). (The spacer will already be fi nished with any applicable substrate, to allow for the vent hood to rest fl ush.)
3. From the inside of the vent hood; fasten the hood to
the bracket using a medium Phillips screwdriver and the 1/4-20 screws supplied with the vent hood (that were originally removed at beginning of installation). See Fig.14-2, Detail A.
4. From the inside of the vent hood, using appropriate
mounting hardware for the spacer construction; secure the top portion of the hood directly into the spacer. Use the supplied support plates when fastening, see Fig. 14-2, Detail B.
Fire Magic spacers include these screws (#10 x 3/4").
Tabs must
engage slots on
rear of hood
Wall mount
bracket
Spacer
Hood
Fig. 14-1 Rest vent hood in place
REAR WALL
B
Fasten hood
directly into spacer (support plates supplied)
(transition not
Spacer
(Flush)
shown for clarity)
Hood
Countertop
(grill not shown
A
for clarity)
Fig. 14-2 Secure vent hood (42" shown)
Install
supplied
screws
through
hood
into wall
bracket
REV 2 - 1502191555
14
L-C2-387
INSTALLATION (cont.)
VENT PIPING
A cutout will need to be made in the roof to route the piping through; and must be sealed with silicone to prevent leaks.
1. Install 10" round galvanized rigid (single wall) vent
piping from the transition on, as required. All joints must be sealed using duct tape.
Important: Vent piping should be installed as straight
as possible to prevent back-pressure on the fans.
Important: If an offset is required for your installation, a
maximum of two 45˚ elbows may be used.
Do not use 90˚ elbows for this installation.
See Fig. 15-2.
2. Using duct tape and the appropriate hardware; install
a termination cap on top of the vent piping to prevent water and debris from entering the vent hood.
Important: A non-restrictive termination cap must be
used. Do not use a restrictive cap for this installation. See Fig. 15-2.
Installation will depend on roof construction and individual setup.
Cap
Install 10" round vent piping as needed
Transition
(vent hood)
Fig. 15-1 Common Installation
INCORRECT CORRECT
90˚
elbow
45˚
elbow
(ROOF)
45˚
elbow
Exceeding a 20 foot total vent piping length will reduce the effectiveness of your exhaust system.
NEVER use 90˚ elbows
Ok to use a max of two
45˚ elbows
Only use non-restrictive
termination caps
Fig. 15-2 Incorrect/Correct Piping Examples
REV 2 - 1502191555
15
L-C2-387
FAN ASSEMBLY
INSTALLATION (cont.)
1. Locate the (4) nuts pre-installed to the ceiling of the
vent hood, and using a 3/8" nut driver, loosen (but do not remove) to allow for the fan assembly to be inserted. See Fig. 16-1.
2. With the open ends of the fans facing the front of the
vent hood, carefully position the fan assembly, aligning the keyholes to the loosened nuts. See Fig. 16-1, A.
3. Mount the fan assembly fl ush against the vent hood
ceiling ensuring the nuts protrude through the keyholes, then slide the assembly to the left so that it to hangs from the nuts. See Fig. 16-1, A and B.
CAUTION: TO PREVENT INJURY OR DAMAGE TO
THE FAN ASSEMBLY, THE FAN MUST BE SUPPORTED UNTIL IT IS PROPERLY SECURED IN PLACE.
4. Fasten the (4) nuts to secure the fan assembly in place
(see Fig. 16-2, C).
WIRING CONNECTIONS
1. A wire connection exists toward the right rear of the fan
assembly. This is to be connected to the wire harness coming out the right rear of the vent hood. See Fig. 16-3, D.
B
A
Fig. 16-1 Insert fan assembly
C
Fig. 16-2 Fasten (4) nuts to secure
D
Fig. 16-3 Connect fan assembly wire
REV 2 - 1502191555
16
L-C2-387
INSTALLATION (cont.)
BAFFLE
1. Carefully raise the baffl e up into the vent hood. You will
fi rst need to slide one side in at a slight angle, until the baffl e edge aligns above the inner wall (see Fig. 17-1). Then raise the opposite side of the baffl e until it also aligns. Drop the baffl e into place.
2. Align the 4 screw holes (2 on each side), then secure
the baffl e in place using a medium Phillips screwdriver and the supplied 8-32 x 3/8" screws (that were originally removed at beginning of installation). See Fig. 17-2.
Align baffl e to
screw holes
Important: To prevent cross-threading the screws they
should be installed with a manual screwdriver and a small amount of household grease.
GREASE FILTERS
1. Install the fi lter spacer (if applicable, 42" models only).
See Fig. 17-3. Repeat for other side.
2. Install a fi lter into the vent hood by fi rst pressing in the
lever, then aligning the tabs found on the fi lter into the notches found in the interior of the hood. The fi lters will secure in place. Repeat for all fi lters. See Fig. 17-4.
Fig. 17-1 Align baffl e
Fasten screws
Fig. 17-2 Secure baffl e
(Front of
vent hood)
Filter spacer installed
REV 2 - 1502191555
17
(Baffl e)
42" models only
Fig. 17-3 Install fi lter spacer (if applicable)
Filter
installed
42"
model
shown
Fig. 17-4 Install fi lters
L-C2-387
INSTALLATION (cont.)
ELECTRICAL
A 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire receptacle (not included) is required within the vicinity of the
vent hood to provide power to the unit. The area above the vent hood that the soffi t / duct cover will enclose is an ideal location (reference Fig 18-1). Your individual installation may vary. Observe all local codes.
1. Wire the receptacle above the top right of the unit (see
Fig 18-1).
• Verify proper polarity of the receptacle.
• If an extension cord is used, ensure it is a 3-wire GROUNDED cord. DO NOT use 2-prong adapters.
• DO NOT TAMPER WITH THE EXTENSION CORD OR THE INSERT POWER-SUPPLY CORD.
2. Connect the power cord coming from the top right of the unit to the previously wired 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire receptacle (see
Fig. 18-1 and Fig. 18-2).
Receptacle
MUST be:
120VAC (15 AMP
minimum) GFCI
GROUNDED 3-wire
(vent piping
not shown for clarity)
Fig. 18-1 Install receptacle & connect power cord
120VAC (15 AMP minimum) GFCI
GROUNDED 3-wire receptacle
3-wire GROUNDED
cord from unit
Note: The power cord must be plugged in when operating
the vent hood.
WARNING: Electrical Grounding Instructions - This
appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Fig. 18-2 Electrical setup detail
REV 2 - 1502191555
18
L-C2-387
INSTALLATION (cont.)
DUCT COVER / CUSTOM SOFFIT
Note: Some installs may not require a duct cover / soffi t, as
island height & roof height may vary. Fire Magic offers a duct cover specifi cally designed for your vent hood. Contact your dealer for ordering information. Alternatively, a custom soffi t can be constructed for your setup. Follow the appropriate section for your spacer type.
Fire Magic Duct Cover:
The Fire Magic duct cover comes ready to be installed.
1. Carefully slide the duct cover into the area above the
already installed spacer and vent hood. Ensure the bottom perimeter of the duct cover rests fl ush with the spacer and vent hood. See Fig. 19-1.
2. From beneath the vent hood, use a medium Phillips
screwdriver and the 8-32 x 3/8" screws supplied with the duct co
ver to secure it to the vent hood. (The screws are to be fastened through the pilot holes found on top of the vent hood and into the duct cover above.) See Fig. 19-1
Important: To prevent cross-threading the screws they should
be installed with a manual screwdriver and a small amount of household grease.
Note: The rear of the duct cover does not need to be secured
to the rear wall.
Important: DO NOT apply sealant to the duct cover as it must
be removable for servicing and for access to the electrical connection.
Custom Soffi t:
Construct the soffi t frame according to your individual install preference, while following the guidelines found in the INSTALLATION REQUIREMENTS section.
When designing the soffi t; account for the thickness of your fi nishing substrate so that overall dimensions are fl ush with the vent hood and spacer below. The soffi t must allow permanent interior access (i.e. access panel/door).
(transition, vent piping, &
electrical not shown for
clarity)
(Flush)
Fig. 19-1 Install Fire Magic Duct Cover
ROOF
S
R E
O F F
I
T
• Soffi t must be properly secured into REAR WALL studs.
• Soffi t must have access panel/door.
A R
W
A
L L
Fig. 19-2 Custom soffi t orientation
(remove grill
if possible)
Duct cover
1. Locate and mark the REAR WALL studs.
2. Using appropriate mounting hardware for the soffi t and rear
wall construction; secure it into the rear wall. The soffi t will rest directly above the spacer and vent hood.
Important: THE SOFFIT MUST BE SECURED INTO
MULTIPLE WALL STUDS, USING THE APPROPRIATE HARDWARE, TO ENSURE PROPER SUPPORT. METAL FRAMEWORK WILL REQUIRE ADDITIONAL WALL STUDS AND SCREWS FOR PROPER SUPPORT. CONSULT A PROFESSIONAL CONTRACTOR
FOR YOUR INDIVIDUAL SETUP.
3. Install fi nishing substrate to left and right sides, and front
of soffi t as appropriate.
Important: The soffi t must allow permanent interior access
(i.e. access panel/door).
REV 2 - 1502191555
19
L-C2-387
OPÉRATION
VENTILATEUR DE CAPOT DE PASSAGE
Pour faire fonctionner les ventilateurs, il suffi t de tourner le bouton du ventilateur situé à l'avant droit de la hotte au réglage désiré. Le bouton du ventilateur est symbolisé par un logo fan gravé à côté de lui. Voir la Fig. 20-1.
Tournez le bouton à la position OFF pour allumer les ventilateurs éteints.
Mettez toujours les fans avant de cuisson afi n d'établir un fl ux d'air. Permettre aux ventilateurs de fonctionner pendant quelques minutes après que vous allumez le gril off, pour assainir l'air et d'en garder la zone sans fumée.
Note: La hotte d'aspiration est équipé d'un interrupteur
thermique interne. Lorsque la zone environnante atteint la température, l'interrupteur thermique se met automatiquement sur les ventilateurs de la hotte de ventilation. Lorsque la hotte est en fonctionnement sur le réglage LO, il passera automatiquement au réglage de HI pour maintenir une température de fonctionnement. Cette fonction est une commodité et évite d'endommager la hotte.
VENTILATEUR LUMIÈRES
Fig. 20-1 Control Panel Detail
ÉCLAIRAGE SUPÉRIEUR DE GRIL
Les lampes halogènes sont contrôlés en tournant le bouton de lumière situé sur le côté avant droit de la hotte au réglage désiré. Le bouton lumière est symbolisée par un logo d'ampoule gravé à côté de lui. Voir Fig. 20-1.
Tournez le bouton à la position OFF pour éteindre les lumières.
Nettoyer la hotte sur une base régulière pour assurer une performance optimale. Voir la section ENTRETIEN ET NETTOYAGE pour plus de détails.
REV 2 - 1502191555
20
L-C2-387
OPERATION
VENT HOOD FANS
To operate the fans, simply turn the fan knob located on the front right of the vent hood to your desired setting. The fan knob is symbolized with a fan logo etched beside it. See Fig. 21-1.
Turn the knob to OFF position to turn the fans off. Always turn the fans on before cooking to establish an air
fl ow. Allow the fans to operate for few minutes after you turn the grill off, to clear the air out and keep the area smoke free.
Note: The vent hood is equipped with an internal thermal
switch. When the surrounding area reaches temperature, the thermal switch will automatically turn on the vent hood fans. When the vent hood is operating on the LO setting, it will automatically switch to the HI setting to maintain a safe operating temperature. This feature is for convenience and prevents damage to the vent hood.
GRILL TOP LIGHTING
FANS
LIGHTS
Fig. 21-1 Control knobs
The halogen lights are controlled by turning the light knob located on the front right side of the vent hood to your desired setting. The light knob is symbolized with a light bulb logo etched beside it. See Fig. 21-1.
Turn the knob to OFF position to turn the lights off.
Clean the vent hood on a regular basis to ensure optimal performance. See the SERVICING AND CLEANING section for details.
REV 2 - 1502191555
21
L-C2-387
SERVICING AND CLEANING
The unit must be off and the power cord must be disconnected prior to beginning any service or cleaning. Any components removed during servicing/cleaning must be reinstalled, as previously instructed in this manual, prior to future operation. CONTACT YOUR DEALER FOR REPLACEMENT PARTS.
REMOVE FIRE MAGIC DUCT COVER (if applicable)
If a Fire Magic Duct Cover is installed, it must fi rst be removed in order to access and disconnect the power cord. To remove, use a medium Phillips screwdriver to unfasten the screws found along the interior top perimeter of the vent hood. Store the screws for later re-installation (after service is complete).
STAINLESS STEEL CARE
Clean your vent hood by fi rst using Fire Magic Barbecue and Grill Cleaner (part #3580-1) to remove grease and dirt. Always wipe with the grain (See Fig. 22-1). Next, use Fire Magic Stainless Steel Cleaner (3581-1) to restore the stainless steel color. Finish by wiping your vent hood down using Fire Magic Polish Wipes (3586-1).
Wipe with grain
Fig. 22-1 Clean vent hood
Press in
lever and
remove
Clean your vent hood at least once a month. If your vent hood is installed in a seaside (salt air) or pool side
(chlorine) location, it will be more susceptible to corrosion and must be maintained/cleaned more frequently. Do not store chemicals (such as chlorine or fertilizer) near your stainless steel appliance.
Due to the nature of stainless steel, surface iron oxide deposits may appear. Do not be alarmed – these deposits are removable with stainless-steel cleaner through prompt and periodic maintenance. If not attended to promptly, permanent pitting may occur.
GREASE FILTERS
Wash the fi lters frequently either in a detergent solution, or by placing them in your dishwasher. Cleaning the fi lters on a regular basis (depending on usage) will ensure optimal performance and longevity of the vent hood.
To remove a fi lter; simply press in the lever and pull it away from the vent hood (see Fig. 22-2).
Once the fi lters are clean, reinstall each into the vent hood by fi rst pressing in the lever, then aligning the tabs found on the fi lter into the notches found in the interior of the hood. The fi lters will secure in place.
Fig. 22-2 Clean grease fi lters
Important: If a fi lter becomes damaged or not cleanable;
it must be replaced.
FANS
Clean the fans on a regular basis (depending on usage) with a damp towel to ensure optimal performance. (The grease fi lters and baffl e will need to be removed to gain access.)
REV 2 - 1502191555
22
L-C2-387
SERVICING AND CLEANING (cont.)
REPLACING HALOGEN BULBS
Important: ONLY REPLACE WITH 120V / 50 WATT
HALOGEN BULB(S).
Important: Wear gloves during this procedure for safety
and to maintain bulb life.
1. Ensure the power cord has been disconnected.
2. With one hand directly below the light assembly, gently
pry the glass lens out using a thin fl at-head screwdriver. Slowly twist the screwdriver handle until the lens is removed.
Glass lens
Note: Replacement should only be done on a light
assembly that is completely cool.
3. Clean the lens with a standard household window
cleaner, dry completely, and set aside.
4. Gently remove the bulb from its socket.
5. Install a new 120V / 50 watt halogen bulb into the
socket, being sure that both pins are properly inserted.
Important: Bulb is halogen. DO NOT TOUCH with bare
hands. Oils from hands drastically reduce bulb life.
6. Place the lens back into the fi xture and snap it into place. Note: The curved cutout of the lens should align over the
bulb when replacing the lens.
7. Repeat as needed.
8. Reconnect the power cord and test.
Fig. 23-1 Light orientation
Bulb
Socket
Fig. 23-2 Replace bulb
REV 2 - 1502191555
23
L-C2-387
NOTES PAGE
REV 2 - 1502191555
Please use this page to record any information that you may want to have at hand.
24
L-C2-387
TROUBLESHOOTING
If you have trouble with this vent hood, please use this list to identify the problem. By trying one or more of the solutions to the possible cause, you should be able to solve the problem. If this list does not cover your present problem, or if you have other technical diffi culties with the vent hood, please contact your local Fire Magic dealer or visit our web site at www.rhpeterson.com.
PROBLEM POSSIBLE CAUSE CORRECTION
Unit does not
turn on
Loss of suction
Switch
malfunction
Fan malfunction
1. No power to hood
2. Switch malfunction
1. Grease fi lter(s) clogged
2. Fan(s) not operating
3. Fan(s) obstructed
1. Defective switch
2. Wire harness shorted/disconnected
1. Defective fan
2. Wire harness shorted/disconnected
3. Fan(s) obstructed
4. Defective switch
1a. Check if unit is plugged in. 1b. Check if GFCI receptacle is tripped.
2. Check or replace switch.
1. Clean or replace fi lter(s).
2. Check or replace fan(s).
3. Check fan(s) for possible obstructions.
1. Check or replace switch.
2. Check wire harness connection.
1. Check or replace fan.
2. Check wire harness connection.
3. Check fan(s) for possible obstructions.
4. Check or replace switch.
Lights do not
turn on
1. Bulb burned out
2. Defective switch
1. Replace bulb.
2. Check or replace switch.
REV 2 - 1502191555
25
L-C2-387
WARRANTY
PETERSON FIRE MAGIC GRILLS AND ACCESSORIES
LIMITED WARRANTY
Robert H. Peterson Co. ("RHP") warrants your Fire Magic® grill to be free from defects in material and workmanship. Fire Magic
your Fire Magic® grill -- LIFETIME. (Except as noted below.) Fire Magic Choice stainless steel tubular burners are warranted for TWENTY (20) YEARS. Fire Magic
warranted for FIFTEEN (15) YEARS. Fire Magic Fire Magic
charcoal pan, charcoal grid, wood pellet screen, thermometer, and ash tray; which are warranted for ONE (1) YEAR. Fire Magic
YEARS. Fire Magic
warranted for ONE (1) YEAR.
This warranty applies to the original purchaser for products which are installed in the United States or Canada and which are operated and maintained as intended for single family residential usage. This warranty is valid only with proof of purchase, shall commence on the date of purchase, and shall terminate (both as to original and any replacement products) on the anniversary date of the original purchase of the product stated on the above schedules.
This warranty covers defects in material and workmanship. This warranty does not cover parts which become defective as a result of negligence, misuse, use not in compliance with the Owner’s Manual/Installation Instructions, accidental damage, improper handling, improper storage, improper installation, lack of required routine maintenance (as specifi ed in the Owner’s Manual/Installation Instructions), electrical damage, local gas impurities or failure to protect against combustibles. Product must be installed (and gas must be connected) as specifi ed in the Owner’s Manual/Installation Instructions by a qualifi ed professional installer. Modifi cations to products which are not specifi cally authorized will void this warranty. Accessories, parts, valves, remotes, etc. when used must be Peterson products or this warranty is void. Warrantied items will be repaired or replaced at Peterson’s sole discretion. This warranty does not apply to rust, corrosion, oxidation, or discoloration unless the affected part becomes inoperable.
This warranty does not cover labor or labor related charges, except as provided by separate specifi c written programs from the Peterson Co. All repair work must be performed by a qualifi ed professional service person and requires prior approval of Peterson.
Peterson may require the defective product or part to be returned to the factory to determine the cause of failure. Peterson will pay freight charges if the product or part is determined to be defective. This warranty does not cover breakage in shipment from our (Independent) distributor to its customer if the damage is determined to have occurred during that shipment.
This warranty specifi cally excludes liability for indirect, incidental, or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specifi ed legal rights, and you may have other rights that vary from state to state or province.
For additional information regarding this warranty, or to place a warranty claim, contact the R. H. Peterson dealer where the product was purchased.
®
cast stainless-steel burners, stainless-steel rod cooking grids, and stainless-steel housings are warranted for as long as you own
®
cast brass burners, brass valves, inner liners, manifold assemblies, and backburner assemblies (except ignition parts) are
®
Electric Grills, including stainless steel grid, and housings are warranted for TEN (10) YEARS.
®
Infra-red burners, fl avor grids, Charcoal stainless steel grills, and Smokers are warranted for FIVE (5) YEARS; except for the
®
sideburners and all other Fire Magic® grill components (except ignition and electronic parts) are warranted for THREE (3)
®
ignition systems (excluding batteries), electronic components (including lights and thermometers), and grill accessories are
A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE IS REQUIRED
TO REGISTER YOUR PRODUCT ONLINE GO TO: WWW.RHPETERSON.COM,
AND CLICK ON PRODUCT REGISTRATION. THANK YOU FOR YOUR PURCHASE.
Quality Check Date:_________________
Electrical Leak Test: _____________________ Model#: ___________________ Operational Test: _____________________ Serial#: ___________________ Inspector: _____________________
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
26