Fire Magic 32871 Installation manual

SEARING STATION SLIDE-IN
3287-1(P)
INSTALLATION AND OPERATING
INSTRUCTIONS
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
SAFETY WARNINGS & CODES
DANGER
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid if equipped.
4. If odor continues, keep away from the
appliance and immediately call your gas supplier or fi re department.
CODE AND SUPPLY REQUIREMENTS: This unit must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with either the latest National Fuel Gas
Code (ANSI Z223.1/NFPA 54), or Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
This appliance and its individual shutoff valves must be disconnected from the gas-supply piping system when testing the system at pressures in
1
excess of This appliance must be isolated from the gas-
supply piping system by closing its individual manual shutoff valves during any pressure testing of the gas-supply system at pressures up to and including
/
psig (3.5 kPa).
2
1
/
psig (3.5 kPa).
2
WARNING
1. Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. A propane cylinder not connected for use
shall not be stored in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration,
service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualifi ed professional installer, service agency, or the gas supplier.
All electrical outlets in the vicinity of the unit must be properly grounded in accordance with local codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever
is applicable. Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
Certifi ed to: ANSI Z21.58-2007 CSA 1.6-2007
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Rev 7 - 0906241112
09-41
254-B-10-5
1
L-C2-20009
BRÛLEUR DESSÉCHANT
AVERTISSEMENTS ET CODES DE SÛRETÉ
INSTALLATION ET CONSIGNES
D’UTILISATION
SLIDE-IN
3287-1(P)
INSTALLATION ET CONSIGNES
D’UTILISATION
INSTALLATEUR : Laissez ces instructions avec le
consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
IMPORTANT: LISEZ CES INSTRUCTIONS SOIGNEUSEMENT AVANT DE COMMENCER L’INSTALLATION
AVERTISSEMENTS ET CODES DE SÛRETÉ
DANGER:
S’il y a une odeur de gaz:
1. Coupez l’admission de gaz de l’appareil.
2. Éteindre toute fl amme nue.
3. Ouvrir le couvercle.
4. Si l’odeur persiste, gardez loin de l’appareil,
et appelez immédiatement le fournisseur de gazou le service d’incendie.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce grill doit être installé selon des codes et des ordonnances locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre le plus défunt code national de gaz
de carburant (norme ANSI Z223.1/NFPA 54), et stockage de gaz naturel et de propane et manipulation du code
d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être démontés du système siffl ant d’offre de gaz en examinant le système aux pressions au-dessus du
psig (kPa 3.5).
Cet appareil doit être isolé dans le système siffl ant d’offre de gaz par fermeture ses différents robinets d’isolement manuels pendant tous les essais sous pression du circuit d’alimentation de gaz aux pressions jusques et y compris
1
le
/
psig (kPa 3.5).
2
Certifi é à la norme: ANSI Z21.58-2007 CSA 1.6-2007
1
/
2
AVERTISSEMENT:
1. Ne pas entreposer ni utiliser de l’essence ni
d’autres vapeurs ou liquides infl ammables dans le voisinage de l’appareil, ni de proximité de tout autre appareil.
2. Une bouteille de propane qui nest pas
raccordée en vue de son utilisation, ne doit pas être entreposée dans le voisinage de
cet appareil ou de tout autre appareil.
AVERTISSEMENT
L’installation inexacte, l’ajustement, le changement, le service ou l’entretien peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour l’aide ou l’information additionnelle consultez un installateur qualifi é et professionnel, l’agence
de service, ou le fournisseur de gaz.
Toutes les sorties électriques à proximité du grill doivent être correctement fondues selon des codes locaux ou, en l’absence des codes locaux, avec le code électrique
national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, qui est jamais applicable.
Gardez tout cordon d’alimentation électrique et tuyau d’alimentation en combustible a l’écart des surfaces chauffées.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Rev 7 - 0906241112
254-B-10-5
09-41
2
L-C2-20009
TABLE OF CONTENTS
SAFETY WARNINGS & CODES 1 TABLE OF CONTENTS 3 CAUTION 3 PRODUCT DATA TABLE 3 PARTS LIST 4 PLANNING FOR INSTALLATION OF THE SEARING STATION 4
WHERE TO INSTALL THE SEARING STATION 4 ENSURING PR
INSTALLATION 5
GAS-SUPPLY PLUMBING REQUIREMENTS 5 CHECKING FUEL AND ORIFICES CONVERTING THE SEARING STATION REGULATOR 6 CONNECTING THE GAS SUPPLY TO THE SEARING STATION 6 LEAK TESTING 6
GENERAL INFORMATION 6
SAFETY TIPS IN USING THE SEARING STATION 6 CARE AND CLEANING
FLAME PATTERN 7
SEARING STATION FLAME PATTERN 7
SAFE USE & MAINTENANCE OF PROPANE-GAS CYLINDERS 9 LIGHTING (IGNITION) INSTR
ELECTRONIC LIGHTING 11
MANU
AL LIGHTING 11
FIRE MAGIC® OUTDOOR GAS GRILL LIMITED WARRANTY 12
OPER COMBUSTION AIR AND COOLING AIRFLOW 4
UCTIONS 11
5
6
CAUTION
Do not strike or scrape the ceramic portion of the burner with hard tools, as the material may crack, chip, or break. Prevent any grease, water, or other foreign material from getting into the ceramic portion of the burner, especially when it is cold. Always wait for the burner to heat up to a well-distributed red glow before placing food on the cooking grid above it. When the burner is hot, it will vaporize small amounts of grease that drip on it. Always cover the burner when not in use. Keeping the ceramic portion of the burner free of foreign substances will allow the gas to circulate and burn over the entire heating surface, allowing for powerful and even cooking over the life of the burner.
PRODUCT DATA TABLE
Specifi cation Value
Height
Width
Depth
Counter opening height*
Counter opening width* 14" (39.4 cm) Counter opening depth* 22-
Main burner
BTU per burner Natural-gas orifi ce Propane-gas orifi ce
12" (30.5 cm)
3
/
" (59 cm)
4
24,400 (7.2 kw)
(2.083 mm)
#45 #55 (1.321 mm)
Rev 7 - 0906241112
Fig. 3-1
Table 1 - Product data table
*Note: If using an insulating liner,
consult liner instructions for counter cut-out dimensions.
3
L-C2-20009
OFF
HI LIGHT
LOW
PARTS LIST
ITEM
DESCRIPTION
NO.
1. Cover
2. Porcelain cast-iron grid or Stainless-steel grid
3. Burner assembly with ignitor
4. Stainless-steel control panel assembly
5. Valve manifold assembly
®
6. Knob, Fire Magic
7. Drip tray assembly with match holder
8. Regulator
9. Ignitor assembly
1
2
3
4
6
9
5
7
8
PLANNING FOR INSTALLATION OF THE SEARING STATION
WHERE TO INSTALL THE SEARING STATION
FOR OUTDOOR USE ONLY
WARNING: The unit must have a minimum of 18" right, left, and back clearance from unprotected combustible
construction such as wood, plastic, or stucco with wood framing. If installing this unit in a combustible surround, the correct R.H. Peterson insulating liner must be used.
Do not install this unit under unprotected fl ammable surfaces. Do not install or use this appliance inside a building, garage, or any other covered or enclosed area. It must not be used in or on recreational vehicles or boats.
This is a slide-in type unit designed to fi t into open-front enclosures. The control panel of the unit is removable for gas hookup, servicing, and conversion. The control panel must remain removable after the unit is installed.
Installer Note: This unit should be installed so that it can be removed at a later date if factory service is required.
Any protrusion into the searing station enclosure may prevent the unit from sliding into place (see GAS-SUPPLY PLUMBING REQUIREMENTS section).
ENSURING PROPER COMBUSTION AIR AND COOLING AIRFLOW
You must maintain proper airfl ow for the Fire-Magic® Searing Station to perform as it was designed (Fig. 4-1). If airfl ow is blocked, overheating and poor combustion will result. Make sure not to block the 1" front air inlet along the bottom of the control panel or more than 75% of the support grid surface with pans or griddles.
Note: The 1" front air space allows access to the drip tray.
Hanger
IMPORTANT
The hanger requires 2" of countertop on each side and back to support
the unit.
Fig. 4-1
Ventilation diagram
EXHAUST REMOVAL
If installed under a patio roof, the cooking grid area should be fully covered by a chimney and exhaust hood. An exhaust fan with a rating of up to 1,000 CFM (472 liters per second) may be necessary to effi ciently remove smoke and other cooking by-products from the covered area. Installation in fully enclosed patio areas is not recommended.